997 resultados para spectrophotometry.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present paper is reported the method for the isolation and extraction of total flavonoids of Epimedium Koreanum Nakai by means of supercritical fluid extraction (SFE). By examining pressure, temperature. amounts of modifier and extraction time, the optimized condition of SFE is confirmed as 30 MPa and 60 degreesC. with 70% ethanol as the modifier. The samples were statically extracted for 30 min, followed by dynamic extraction for 120 min at a flow rate of 6 mL/min. The quantitative analysis of total flavonoids was performed by UV-Vis spectrophotometry. Compared with the conventional method, the SFE method is more efficient. more rapid and more friendly environmentally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using electrospray tandem mass spectrometry (ESI-MSn), the flavonoids obtained from leaves in Acanthopanax Senticosus Harms were analyzed. The typical colorimetric method and the ultroviolet spectrophotometry were also utilized for the determination of the content of total flavonoids. The analytical results showed that there was quercetin as well as its derivatives in leaves of acanthopanax senticosus harms and their content was as high as 37.25%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cytochrome c and hydrogen peroxide-dependent oxidation of m-aminophenol was investigated by electrochemistry and spectrophotometry. The results indicated that the hydroxylated species of m-aminophenol have at least two conjugated substituted groups on the ring system (most possibly, its oxidized form 2-hydroxy-4-iminoquinone), and that the degradation of cytochrome c by hydrogen peroxide can also be prevented in the presence of m-aminophenol. The hydroxyl radical scavengers, mannitol and sodium benzoate, almost completely eliminate the hydroxylation of m-aminophenol. But oxo-heme species scavenger, uric acid, does not inhibit the hydroxylation. Combining the results of mass spectrum, nuclear magnetic resonance and element analysis with that of spectrophotometry, electrochemistry and chemical scavengers, it is suggested that cytochrome c may act as a peroxidase, which facilitates the hydroxylation and subsequent dimerization of m-aminophenol. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hydrogen peroxide (H2O2) and cytochrome c-dependent oxidation of o-phenylenediamine (o-PD) was investigated by spectrophotometry and electrochemistry. The results indicated that o-PD underwent facile catalytic oxidation in the presence of cytochrome c, and that the degradation of cytochrome c by hydrogen peroxide can also be partly prevented in the presence of o-PD. The hydroxyl radical scavengers (mannitol and sodium benzoate) and oxo-heme species scavenger (uric acid) do not inhibit the oxidation, which implies that the hydroxylation of o-PD may not be involved in its oxidation. Combining with the results of the mass spectrum, elemental analysis, nuclear magnetic resonance and Fourier transform infrared spectrum of the isolated product, a conceivable structure of the product was suggested. (C) 1998 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxidation-reduction properties of horseradish peroxidase (HRP) have been investigated by using direct electrochemical methods. Two successive separated distinct one-electron processes of HRP were obtained and the related physiological processes were described. The monolayer coverage of HRP at the electrode surface is about 50 pmol/cm(2). UV-Vis spectrophotometry and stable amperometry prove that the enzyme electrode possesses catalytic activity for H2O2 in the absence of a mediator and it might offer an opportunity to build the third generation of biosensors for analytes, such as H2O2, glucose and cholesterol etc. (C) 1997 Elsevier Science S.A.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grattan, J.P., Al-Saad, Z., Gilbertson, D.D., Karaki, L.O., Pyatt, F.B 2005 Analyses of patterns of copper and lead mineralisation in human skeletons excavated from an ancient mining and smelting centre in the Jordanian desert Mineralogical Magazine. 69(5) 653-666.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bifunctional complex [Ru(TAP)(2)POQ-Nmet](2+), 1, formed with a [Ru(TAP)(2)Phen](2+) metallic unit linked to a quinoline moiety, and [Ru(TAP)(2)Phen](2+), 2, as reference, have been tested as photoprobes of DNA. Interestingly, 1 exhibits an emission enhancement of a factor of 16-17 upon binding to calf thymus DNA. Moreover, this emission is modulated by the nucleic base content of the polynucleotide. It varies by almost an order of magnitude from a polynucleotide containing 100% of G-C to a guanine-free nucleic acid where the excited-state lifetime reaches about 2 micros. The origins of these interesting properties are analyzed by comparing 1 with reference 2 in the presence of different polynucleotides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Push-pull" chromophores based on extended pi-electron systems have been designed to exhibit exceptionally large molecular hyperpolarizabilities. We have engineered an amphiphilic four-helix bundle peptide to vectorially incorporate such hyperpolarizable chromophores having a metalloporphyrin moiety, with high specificity into the interior core of the bundle. The amphiphilic exterior of the bundle facilitates the formation of densely packed monolayer ensembles of the vectorially oriented peptide-chromophore complexes at the liquid-gas interface. Chemical specificity designed into the ends of the bundle facilitates the subsequent covalent attachment of these monolayer ensembles onto the surface of an inorganic substrate. In this article, we describe the structural characterization of these monolayer ensembles at each stage of their fabrication for one such peptide-chromophore complex designated as AP0-RuPZn. In the accompanying article, we describe the characterization of their macroscopic nonlinear optical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrafast UV-vibrational spectroscopy was used to investigate how vibrational excitation of the bridge changes photoinduced electron transfer between donor (dimethylaniline) and acceptor (anthracene) moieties bridged by a guanosine-cytidine base pair (GC). The charge-separated (CS) state yield is found to be lowered by high-frequency bridge mode excitation. The effect is linked to a dynamic modulation of the donor-acceptor coupling interaction by weakening of H-bonding and/or by disruption of the bridging base-pair planarity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultraviolet-visible spectroscopy readily discerns the two types of melanin pigments (eumelanin and pheomelanin), although fundamental details regarding the optical properties and pigment heterogeneity are more difficult to disentangle via analysis of the broad featureless absorption spectrum alone. We employed nonlinear transient absorption spectroscopy to study different melanin pigments at near-infrared wavelengths. Excited-state absorption, ground-state depletion, and stimulated emission signal contributions were distinguished for natural and synthetic eumelanins and pheomelanins. A starker contrast among the pigments is observed in the nonlinear excitation regime because they all exhibit distinct transient absorptive amplitudes, phase shifts, and nonexponential population dynamics spanning the femtosecond-nanosecond range. In this manner, different pigments within the pheomelanin subclass were distinguished in synthetic and human hair samples. These results highlight the potential of nonlinear spectroscopies to deliver an in situ analysis of natural melanins in tissue that are otherwise difficult to extract and purify.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The difference in electrostatics and reduction potentials between manganese ortho-tetrakis(N-ethylpyridinium-2-yl)porphyrin (MnTE-2-PyP) and manganese meta-tetrakis(N-ethylpyridinium-3-yl)porphyrin (MnTE-3-PyP) is a challenging topic, particularly because of the high likelihood for their clinical development. Hence, a detailed study of the protolytic and electrochemical speciation of Mn(II-IV)TE-2-PyP and Mn(II-IV)TE-3-PyP in a broad pH range has been performed using the combined spectrophotometric and potentiometric methods. The results reveal that in aqueous solutions within the pH range ∼2-13 the following species exist: (H(2)O)Mn(II)TE-m-PyP(4+), (HO)Mn(II)TE-m-PyP(3+), (H(2)O)(2)Mn(III)TE-m-PyP(5+), (HO)(H(2)O)Mn(III)TE-m-PyP(4+), (O)(H(2)O)Mn(III)TE-m-PyP(3+), (O)(H(2)O)Mn(IV)TE-m-PyP(4+) and (O)(HO)Mn(IV)TE-m-PyP(3+) (m = 2, 3). All the protolytic equilibrium constants that include the accessible species as well as the thermodynamic parameters for each particular protolytic equilibrium have been determined. The corresponding formal reduction potentials related to the reduction of the above species and the thermodynamic parameters describing the accessible reduction couples were calculated as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present measurements of morphological features in a thick turbid sample using light-scattering spectroscopy (LSS) and Fourier-domain low-coherence interferometry (fLCI) by processing with the dual-window (DW) method. A parallel frequency domain optical coherence tomography (OCT) system with a white-light source is used to image a two-layer phantom containing polystyrene beads of diameters 4.00 and 6.98 mum on the top and bottom layers, respectively. The DW method decomposes each OCT A-scan into a time-frequency distribution with simultaneously high spectral and spatial resolution. The spectral information from localized regions in the sample is used to determine scatterer structure. The results show that the two scatterer populations can be differentiated using LSS and fLCI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative tissue characterization and disease diagnosis. Significant systematic errors can arise in the measured reflectance spectra and thus in the derived tissue physiological and morphological parameters due to real-time instrument fluctuations. We demonstrate a novel fiber optic probe with real-time, self-calibration capability that can be used for UV-visible diffuse reflectance spectroscopy in biological tissue in clinical settings. The probe is tested in a number of synthetic liquid phantoms over a wide range of tissue optical properties for significant variations in source intensity fluctuations caused by instrument warm up and day-to-day drift. While the accuracy for extraction of absorber concentrations is comparable to that achieved with the traditional calibration (with a reflectance standard), the accuracy for extraction of reduced scattering coefficients is significantly improved with the self-calibration probe compared to traditional calibration. This technology could be used to achieve instrument-independent diffuse reflectance spectroscopy in vivo and obviate the need for instrument warm up and post∕premeasurement calibration, thus saving up to an hour of precious clinical time.