999 resultados para sistema de controle interno
Resumo:
This dissertation deals with the possibility of build an effective social control of the judiciary Brazilians. The theme was bounded by a cut geographic and secular: the experience of the Center of Justice and Citizenship in the state of Rio Grande do Norte (OJC/RN), which begins formally in august 2003. The research approach and leave of experience in judicial practice and policy specific substrates to theorize about the subject. We collected documents about cases, the judicial diagnoses, reports, news material, in addition to lifting bibliographic. Therefore, it is working with about notions of a democratic state of right in the light of the Brazilian Constitution of 1988, in order to contextualize the insertion of the judicial system, by the prospect of legitimacy, which is considered by a look formal and material. It is a brief analysis of the system of official control of the judiciary (internal and external), is emphasizing its shortcomings functional and its corporate character, which suffers from poor conformation democratic. Then there is a discussion about the need to establish the social control of the judiciary, through the prism of relations of power that are locked in the judiciary, the lack of formal criteria for the guarantee of obtaining the correct judgment (laws, precedents and conscience of the judge), the problems of impunity and justice class, and from the examination of some cases, as the body of search. From this conjuncture, prepares to be an outline of shapes and the limits of social control, consonant the proposal erected in certain sectors of organized civil society, represented by the movement s social OJC. In the end, considerations are made on the legitimacy and constitutionality of OJC
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
With the technological progress the people are more and more looking for convenience, comfort and safety to your homes. The residential automation is winning space on the market not only by the status and modernity that provide, but also to allow a better use of natural resources, reducing the expense to keep up a residence. This work shows the development of a control system and supervision to be destined to the residential automation. The developed software will be working together with a controller (PLC), acting in the administration, control and supervision all the linked devices, and offering to the user an environment simple and practical for the control residence
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
Traditional irrigation projects do not locally determine the water availability in the soil. Then, irregular irrigation cycles may occur: some with insufficient amount that leads to water deficit, other with excessive watering that causes lack of oxygen in plants. Due to the nonlinear nature of this problem and the multivariable context of irrigation processes, fuzzy logic is suggested to replace commercial ON-OFF irrigation system with predefined timing. Other limitation of commercial solutions is that irrigation processes either consider the different watering needs throughout plant growth cycles or the climate changes. In order to fulfill location based agricultural needs, it is indicated to monitor environmental data using wireless sensors connected to an intelligent control system. This is more evident in applications as precision agriculture. This work presents the theoretical and experimental development of a fuzzy system to implement a spatially differentiated control of an irrigation system, based on soil moisture measurement with wireless sensor nodes. The control system architecture is modular: a fuzzy supervisor determines the soil moisture set point of each sensor node area (according to the soil-plant set) and another fuzzy system, embedded in the sensor node, does the local control and actuates in the irrigation system. The fuzzy control system was simulated with SIMULINK® programming tool and was experimentally built embedded in mobile device SunSPOTTM operating in ZigBee. Controller models were designed and evaluated in different combinations of input variables and inference rules base
Resumo:
Atualmente há uma grande preocupação em relação a substituição das fontes não renováveis pelas fontes renováveis na geração de energia elétrica. Isto ocorre devido a limitação do modelo tradicional e da crescente demanda. Com o desenvolvimento dos conversores de potência e a eficácia dos esquemas de controle, as fontes renováveis têm sido interligadas na rede elétrica, em um modelo de geração distribuída. Neste sentido, este trabalho apresenta uma estratégia de controle não convencional, com a utilização de um controlador robusto, para a interconexão de sistemas fotovoltaicos com à rede elétrica trifásica. A compensação da qualidade de energia no ponto de acoplamento comum (PAC) é realizada pela estratégia proposta. As técnicas tradicionais utilizam detecção de harmônicos, já neste trabalho o controle das correntes é feita de uma forma indireta sem a necessidade desta detecção. Na estratégia indireta é de grande importância que o controle da tensão do barramento CC seja efetuado de uma forma que não haja grandes flutuações, e que a banda passante do controlador em regime permanente seja baixa para que as correntes da rede não tenham um alto THD. Por este motivo é utilizado um controlador em modo dual DSM-PI, que durante o transitório se comporta como um controlador em modo deslizante SM-PI, e em regime se comporta como um PI convencional. A corrente é alinhada ao ângulo de fase do vetor tensão da rede elétrica, obtido a partir do uso de um PLL. Esta aproximação permite regular o fluxo de potência ativa, juntamente com a compensação dos harmônicos e também promover a correção do fator de potência no ponto de acoplamento comum. Para o controle das correntes é usado um controlador dupla sequencia, que utiliza o princípio do modelo interno. Resultados de simulação são apresentados para demonstrar a eficácia do sistema de controle proposto
Resumo:
The aim of this study is to assess the usability of the Integrated Management System for Academic Activities (SIGAA) for the sensu stricto postgraduate programs at Universidade Federal do Rio Grande do Norte. The study was based on ergonomic criteria proposed by Bastien and Scapin (1993) and the Federal Government s Handbook of Usability (2010). The methodology used was a descriptive data survey involving an online questionnaire, and a sample of 46 system users, composed of coordinators and secretaries from the sensu stricto postgraduate programs. In addition to this procedure, open interviews were held with the users as well as a documental analysis of calls registered by them at the SIGAA between May 2012 and June 2013. Data analysis showed that a number of additional usability criteria need to be implemented, primarily related to ergonomic problems of orientation, error management and workload. Based on the analyses, several changes were proposed that may streamline secretarial activities, as well as provide greater satisfaction and interaction between the SIGAA and its users
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Zootecnia - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O controle da mistura ar/combustível é muito importante para o correto funcionamento dos motores à combustão interna ciclo Otto. A relação entre o ar e o combustível influencia diretamente no funcionamento do motor, na emissão de poluentes e no consumo de combustível. Este trabalho apresenta o desenvolvimento de um controle da mistura ar/combustível a partir do estudo de modelos de malha fechada deste sistema. Esse controle tem por objetivo manter a mistura o mais próxima possível do ponto estequiométrico, a fim de otimizar a taxa de conversão de gases poluentes pelo catalisador, e utiliza um sensor de oxigênio, conhecido como sonda lambda, para realizar a realimentação do sistema, indicando se a mistura está no ponto estequiométrico. Este trabalho também apresenta o desenvolvimento de um compensador em malha fechada para controlar a mistura a/c (ar/combustível) em outros pontos, além do estequiométrico, através do uso de uma sonda lambda de banda larga.
Resumo:
O Centro Gestor e Operacional do Sistema de Prote????o da Amaz??nia (Censipam) desenvolveu, com o apoio t??cnico do Departamento de Programas de Gest??o da Secretaria de Gest??o do Minist??rio do Planejamento Or??amento e Gest??o, o seu alinhamento estrat??gico. Essa atividade abrangeu desde a auto-avalia????o da gest??o e a an??lise dos ambientes interno e externo at?? a defini????o e an??lise de consist??ncia dos componentes estrat??gicos e finalizou-se com a defini????o, a implementa????o e o monitoramento do Plano de Melhoria da Gest??o, denominado de Plano de A????o do Censipam ??? PAS 2005/2006. Para a implementa????o e monitoramento do plano, a equipe do Censipam desenvolveu planilhas eletr??nicas, em software comercial largamente utilizado, que permitem o cadastro, o envio das informa????es e a gera????o autom??tica de relat??rios sobre o desenvolvimento das a????es e do plano. Esta experi??ncia mostra que podem ser desenvolvidas e implementadas solu????es simples, com o apoio t??cnico especializado de ??rg??os do pr??prio governo, utilizando-se tecnologias e recursos dispon??veis, para melhorar a efic??cia e efici??ncia da gest??o dos ??rg??os p??blicos, bastando, para tanto, decis??o e apoio institucionais
Resumo:
A Delegacia Federal de Agricultura/MS- DFA/MS elaborou um manual de procedimento padr??o no processo de fiscaliza????o e criou um in??dito sistema de controle e registro de "n??o conformidades" nos processos de fiscaliza????o, que al??m de n??o trazer nenhum custo extra ?? reparti????o, motiva o trabalho em equipe e ?? melhoria cont??nua nos processos de trabalho. Esta a????o inova, tamb??m, por constituir-se numa ferramenta de trabalho que permite a avalia????o do desempenho institucional e do desempenho individual do servidor, e induz por, conseq????ncia, ao aumento da efici??ncia organizacional