937 resultados para rotary disc filter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the modelling and experimental validation of a photopolymerizable hydrogel for a Nucleus Pulposus replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many empirical studies of business cycles have followed the practise ofapplying the Hodrick-Prescott filter for cross-country comparisons. Thestandard procedure is to set the weight \lambda, which determines the'smoothness' of the trend equal to 1600. We show that if this value isused for against common wisdom about business cycles. As an example, weshow that the long recession occurred inSpain between 1975 and 1985 goesunnotoced by the HP filter. We propose a method for adjusting \lambda byreinterpreting the HP-filter as the solution to a constrained minimizationproblem. We argue that the common practice of fixing \lambda across countriesamounts to chankging the constraints on trend variability across countries.Our proposed method is easy to apply, retains all the virtues of thestandard HP-filter and when applied to Spanish data the results are inthe line with economic historian's view. Applying the method to a numberof OECD countries we find that, with the exception of Spain, Italy andJapan, the standard choice of \lambda=1600 is sensible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: Studies involving factor analysis (FA) of the items in the North American Spine Society (NASS) outcome assessment instrument have revealed inconsistent factor structures for the individual items. PURPOSE: This study examined whether the factor structure of the NASS varied in relation to the severity of the back/neck problem and differed from that originally recommended by the developers of the questionnaire, by analyzing data before and after surgery in a large series of patients undergoing lumbar or cervical disc arthroplasty. STUDY DESIGN/SETTING: Prospective multicenter observational case series. PATIENT SAMPLE: Three hundred ninety-one patients with low back pain and 553 patients with neck pain completed questionnaires preoperatively and again at 3 to 6 and 12 months follow-ups (FUs), in connection with the SWISSspine disc arthroplasty registry. OUTCOME MEASURES: North American Spine Society outcome assessment instrument. METHODS: First, an exploratory FA without a priori assumptions and subsequently a confirmatory FA were performed on the 17 items of the NASS-lumbar and 19 items of the NASS-cervical collected at each assessment time point. The item-loading invariance was tested in the German version of the questionnaire for baseline and FU. RESULTS: Both NASS-lumbar and NASS-cervical factor structures differed between baseline and postoperative data sets. The confirmatory analysis and item-loading invariance showed better fit for a three-factor (3F) structure for NASS-lumbar, containing items on "disability," "back pain," and "radiating pain, numbness, and weakness (leg/foot)" and for a 5F structure for NASS-cervical including disability, "neck pain," "radiating pain and numbness (arm/hand)," "weakness (arm/hand)," and "motor deficit (legs)." CONCLUSIONS: The best-fitting factor structure at both baseline and FU was selected for both the lumbar- and cervical-NASS questionnaires. It differed from that proposed by the originators of the NASS instruments. Although the NASS questionnaire represents a valid outcome measure for degenerative spine diseases, it is able to distinguish among all major symptom domains (factors) in patients undergoing lumbar and cervical disc arthroplasty; overall, the item structure could be improved. Any potential revision of the NASS should consider its factorial structure; factorial invariance over time should be aimed for, to allow for more precise interpretations of treatment success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This note describes how the Kalman filter can be modified to allow for thevector of observables to be a function of lagged variables without increasing the dimensionof the state vector in the filter. This is useful in applications where it is desirable to keepthe dimension of the state vector low. The modified filter and accompanying code (whichnests the standard filter) can be used to compute (i) the steady state Kalman filter (ii) thelog likelihood of a parameterized state space model conditional on a history of observables(iii) a smoothed estimate of latent state variables and (iv) a draw from the distribution oflatent states conditional on a history of observables.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an open-source ITK implementation of a directFourier method for tomographic reconstruction, applicableto parallel-beam x-ray images. Direct Fourierreconstruction makes use of the central-slice theorem tobuild a polar 2D Fourier space from the 1D transformedprojections of the scanned object, that is resampled intoa Cartesian grid. Inverse 2D Fourier transform eventuallyyields the reconstructed image. Additionally, we providea complex wrapper to the BSplineInterpolateImageFunctionto overcome ITKâeuro?s current lack for image interpolatorsdealing with complex data types. A sample application ispresented and extensively illustrated on the Shepp-Loganhead phantom. We show that appropriate input zeropaddingand 2D-DFT oversampling rates together with radial cubicb-spline interpolation improve 2D-DFT interpolationquality and are efficient remedies to reducereconstruction artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to determine whether the filters used in microirrigation systems can remove potentially emitter-clogging particles. The particle size and volume distributions of different effluents and their filtrates were established, and the efficiency of the removal of these particles and total suspended solids by screen, disc and sand filters determined. In most of the effluents and filtrates, the number of particles with a diameter > 20 μm was minimal. By analysing the particle volume distribution it was found that particles larger than the disc and screen filter pores appeared in the filtrates. However, the sand filter was able to retain particles larger than the pore size. The filtration efficiency depended more on the type of effluent than on the filter. It was also found that the particle size distribution followed a potential law. Analysis of the β exponents showed that the filters did not significantly modify the particle size distribution of the effluents

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the differences between Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: 105 eyes of 56 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter/500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter/695nm barrier filter) before and after FFA. The quality of the FAF images was compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo-and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior resolution in 18, while Topcon images were estimated superior in 29 eyes. No difference was found in 58 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found associated with better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (72%), but showed mild autofluorescence on Topcon (85%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 53% Iso-FAF, in 43% mild Hypo-FAF, and in 4% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to serous exudation showed better on HRA. Cystic edema was visible only on HRA in a petaloid hyper-FAF pattern in 83%, while only two eyes (17%) showed similar behavior in both HRA- and Topcon images. Hard exudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blockage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract and poor fixation respectively. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behavior, there are differences between the 2 systems which need to be taken into account when interpreting the images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of making a multiple matched filter which allows the recognition of different characters in successive planes in simple conditions is proposed. The generation of the filter is based on recording on the same plate the Fourier transforms of the different patterns to be recognized, each of which is affected by different spherical phase factors because the patterns have been placed at different distances from the lens. This is proved by means of experiments with a triple filter which allows satisfactory recognition of three characters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wing of the fruit fly, Drosophila melanogaster, with its simple, two-dimensional structure, is a model organ well suited for a systems biology approach. The wing arises from an epithelial sac referred to as the wing imaginal disc, which undergoes a phase of massive growth and concomitant patterning during larval stages. The Decapentaplegic (Dpp) morphogen plays a central role in wing formation with its ability to co-coordinately regulate patterning and growth. Here, we asked whether the Dpp signaling activity scales, i.e. expands proportionally, with the growing wing imaginal disc. Using new methods for spatial and temporal quantification of Dpp activity and its scaling properties, we found that the Dpp response scales with the size of the growing tissue. Notably, scaling is not perfect at all positions in the field and the scaling of target gene domains is ensured specifically where they define vein positions. We also found that the target gene domains are not defined at constant concentration thresholds of the downstream Dpp activity gradients P-Mad and Brinker. Most interestingly, Pentagone, an important secreted feedback regulator of the pathway, plays a central role in scaling and acts as an expander of the Dpp gradient during disc growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The response of sugarcane to application of micronutrients is still not very well known. In view of the need for this information, the aim of this study was to evaluate the application of the micronutrients Zn, Cu, Mn, Fe, B, and Mo to plant cane in three soils, with and without application of filter cake. This study consisted of three experiments performed in the State of São Paulo, Brazil, (in Igaraçu do Tiete, on an Oxisol; in Santa Maria da Serra, on an Entisol, both in the 2008/2009 growing season; and in Mirassol, on an Ultisol, in the 2009/2010 growing season) in a randomized block design with four replications with a 8 x 2 factorial combination of micronutrients (1 - no application/control, 2 - addition of Zn, 3 - addition of Cu, 4 - addition of Mn 5 - addition of Fe, 6 - addition of B, 7 - addition of Mo, 8 - Addition of Zn, Cu, Mn, Fe, B, and Mo) and filter cake (0 and 30 t ha-1 of filter cake) in the furrow at planting. The application of filter cake was more efficient than of Borax in raising leaf B concentration to sufficiency levels for sugarcane in the Entisol, and it increased mean stalk yield in the Oxisol. In areas without filter cake application, leaf concentrations were not affected by the application of Zn, Cu, Mn, Fe, B, and Mo in the furrow at planting; however, Zn and B induced an increase in stalk and sugar yield in micronutrient-poor sandy soil.