984 resultados para pressure measurements


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports the surface activity of phytase at the air-water interface, its interaction with lipid monolayers, and the construction of a new phytic acid biosensor on the basis of the Langmuir-Blodgett (LB) technique. Phytase was inserted in the subphase solution of dipalmitoylphosphatidylglycerol (DPPG) Langmuir monolayers, and its incorporation to the air-water interface was monitored with surface pressure measurements. Phytase was able to incorporate into DPPG monolayers even at high surface pressures, ca. 30 mN/m, under controlled ionic strength, pH, and temperature. Mixed Langmuir monolayers of phytase and DPPG were characterized by surface pressure-area and surface potential-area isotherms, and the presence of the enzyme provided an expansion in the monolayers ( when compared to the pure lipid at the interface). The enzyme incorporation also led to significant changes in the equilibrium surface compressibility (in-plane elasticity), especially in liquid-expanded and liquid-condensed regions. The dynamic surface elasticity for phytase-containing interfaces was investigated using harmonic oscillation and axisymmetric drop shape analysis. The insertion of the enzyme at DPPG monolayers caused an increase in the dynamic surface elasticity at 30 mN m(-1), indicating a strong interaction between the enzyme and lipid molecules at a high-surface packing. Langmuir-Blodgett (LB) films containing 35 layers of mixed phytase-DPPG were characterized by ultraviolet-visible and fluorescence spectroscopy and crystal quartz microbalance nanogravimetry. The ability in detecting phytic acid was studied with voltammetric measurements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES To test the hypothesis that glyco protein 91phox (gp91(phox)) subunit of nicotinamide adenine dinucleotide phosphate [NAD(P) H] oxidase is a fundamental target for physical activity to ameliorate erectile dysfunction (ED). Vascular risk factors are reported to contribute to ED. Regular physical exercise prevents cardiovascular diseases by increasing nitric oxide (NO) production and/or decreasing NO inactivation.METHODS Male Wistar rats received the NO synthesis inhibitor N(omega)-nitro-L-arginine methyl ester (L-NAME) for 4 weeks, after which animals were submitted to a run training program for another 4 weeks. Erectile functions were evaluated by in vitro cavernosal relaxations and intracavernous pressure measurements. Expressions of gp91(phox) subunit and neuronal nitric oxidase synthase in erectile tissue, as well as superoxide dismutase activity and nitrite/nitrate (NO(x)) levels were determined.RESULTS The in vitro acetylcholine-and electrical field stimulation-induced cavernosal relaxations, as well as the increases in intracavernous pressure were markedly reduced in sedentary rats treated with L-NAME. Run training significantly restored the impaired cavernosal relaxations. No alterations in the neuronal nitric oxidase synthase protein expression (and its variant penile neuronal nitric oxidase synthase) were detected. A reduction of NO(x) levels and superoxide dismutase activity was observed in L-NAME-treated animals, which was significantly reversed by physical training. Gene expression of subunit gp91(phox) was enhanced by approximately 2-fold in erectile tissue of L-NAME-treated rats, and that was restored to basal levels by run training.CONCLUSIONS Our study shows that ED seen after long-term L-NAME treatment is associated with gp91(phox) subunit upregulation and decreased NO bioavailability. Exercise training reverses the increased oxidative stress in NO-deficient rats, ameliorating the ED. UROLOGY 75: 961-967, 2010. (C) 2009 Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As arterial hypertension can be diagnosed by different methods, among which are the traditional auscultatory instrument and the automated oscillometric monitor, the aim of this study was to compare the performance of these instruments, to evaluate the reliability of the digital oscillometer. The sample consisted of 40 patients under dental treatment, whose blood pressure measurements were recorded. The measurements of systolic and diastolic blood pressures were evaluated in terms of their intraclass correlation coefficients (r). For systolic blood pressure, an excellent level of agreement was found between the instruments, with r=0.93, and for diastolic blood pressure, there was a good level of agreement (r=0.75). It was concluded, from the excellent agreement for systolic blood pressure, that the oscillometric monitor can be recommended for the monitoring of the variations of that pressure in the same individual, while the good agreement obtained in the determination of the diastolic blood pressure indicates that the oscillometric method is reliable. However, new studies need to be carried out for a better understanding of the disagreements that can occur in the diastolic pressure results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Model: Prevalence study. Objectives: To evaluate the presence of self-reported hypertension to compare with blood pressure measurements. Besides, this work investigated health information level of workers and if the job position has any influence on blood pressure (BP). Methods: This study evaluated 349 health workers (44±10 years old) from Bauru and Jau cities, who answered some questions about history of health condition, use of medicines, past surgeries as well as social, scholar and physical conditions and had their blood pressure measured. Each subject selfreported as normotensive or hypertensive. Values of systolic ≥ 140 mmHg and/or diastolic PA ≥ 90 mmHg were considered elevated. Among the health workers evaluated, 198 were submitted to anthropometric and biochemical evaluations. Values are presented as means ± SD and frequency of distribution. It was used T-student test (p<0.05). Results: From all workers evaluated only 16% self-reported as hypertensive, which 56% presented high BP, however 91% used to take antihypertensive medicines. Among the 84% who self-reported as normotensive, 24% presented high BP and 8% used to take medicines. Although most of the employees of each section self-reported as normotensive, more than a half presented high BP and which was more common in the health's section (76.3%). Conclusion: These results suggest that besides the majority of the employees self-reported as normotensive, an elevated number of health workers presented high blood pressure and used to take medicines inappropriately, which indicates that they did not have enough knowledge about their health. Furthermore, it was observed that Health Section presented the higher blood pressure values.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This quasi-experimental study describes the effects of a yoga sequence following hemodynamic and biochemical parameters in patients with hypertension. Thirty-three volunteers participated in the study (control = 16 and yoga = 17) for four months. Blood pressure measurements, cardiac and respiratory rate were collected monthly, while the biochemical profile was taken at the beginning and end of the program. To analyze the data, Student's t test and repeated measures analyses were performed. The yoga group showed a significant reduction of systolic blood pressure, heart and respiratory rate (p < 0.05). As for the biochemical profile, the yoga group showed correlation coefficients between initial values and final responses greater than the control of fasting glucose, total cholesterol, LDL-cholesterol and triglycerides. The elaborated sequence practice promoted significant cardiovascular and metabolic benefits. The yoga exercises performed in the proposed sequence constitute complementary non-pharmacological control of blood pressure in patients with hypertension. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The practice of regular physical activity has been considered a protective factor against the degenerative processes of the body, acting as a promoter of health, especially for risk groups such as obese and resistant groups exercise adherence as among the intellectually disabled (ID) . This study involved the administration of a training protocol and the physical parameters of longitudinal health in a subject about 43 years, intellectually deficient, hypertensive, obese and with a strong predisposition to develop diabetes and heart disease. The main objective of long-term program was to reduce body weight and normalize blood pressure (BP) after the student's physical activity and preferentially interfere with BP values at rest (ie before the daily schedule). The other objective was to improve general physical fitness. The protocol involved four meetings per week lasting one hour, in addition to participation in the program PROEFA (twice a week with sessions of one hour each), totaling 57 sessions spread over five months. The evaluation protocol included in each session the following tests: blood pressure measurements and heart rate, and amount of physical activity recorded via pedometer. Tests applied before and after the training included: anthropometric assessment, agility test, flexibility test, test drive through vertical and horizontal jumps and endurance to the test bench. The mass (kg) and BMI corresponded to the initial values of 127.7 kg and 42.05 kg m-2, and 5 months after 113.2 kg and 37.48 kg m-2, respectively. The waist-hip ratio was close to 1 after the intervention and this value corresponded to 0.98. For the test of agility (shuttle run) was not found improvement in performance. To test the values of the horizontal jump in pre-test were 52 cm and 56 cm post-test, vertical jump has been improved and...(Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate cardiovascular autonomic function in a rodent obesity model induced by monosodium glutamate injections during the first seven days of life. METHOD: The animals were assigned to control (control, n = 10) and monosodium glutamate (monosodium glutamate, n = 13) groups. Thirty-three weeks after birth, arterial and venous catheters were implanted for arterial pressure measurements, drug administration, and blood sampling. Baroreflex sensitivity was evaluated according to the tachycardic and bradycardic responses induced by sodium nitroprusside and phenylephrine infusion, respectively. Sympathetic and vagal effects were determined by administering methylatropine and propranolol. RESULTS: Body weight, Lee index, and epididymal white adipose tissue values were higher in the monosodium glutamate group in comparison to the control group. The monosodium glutamate-treated rats displayed insulin resistance, as shown by a reduced glucose/insulin index (-62.5%), an increased area under the curve of total insulin secretion during glucose overload (39.3%), and basal hyperinsulinemia. The mean arterial pressure values were higher in the monosodium glutamate rats, whereas heart rate variability (>7 times), bradycardic responses (>4 times), and vagal (similar to 38%) and sympathetic effects (similar to 36%) were reduced as compared to the control group. CONCLUSION: Our results suggest that obesity induced by neonatal monosodium glutamate treatment impairs cardiac autonomic function and most likely contributes to increased arterial pressure and insulin resistance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The reduction of the pelvic floor muscles (PFM) strength is a major cause of stress urinary incontinence (SUI). Objective: To compare active and passive forces, and vaginal cavity aperture in continent and stress urinary incontinent women. Method: The study included a total of thirty-two women, sixteen continent women (group 1 - G1) and sixteen women with SUI (group 2 - G2). To evaluate PFM passive and active forces in anteroposterior (sagittal plane) and left-right directions (frontal plane) a stainless steel specular dynamometer was used. Results: The anteroposterior active strength for the continent women (mean +/- standard deviation) (0.3 +/- 0.2 N) was greater compared to the values found in the evaluation of incontinent women (0.1 +/- 0.1 N). The left-right active strength (G1=0.43 +/- 0.1 N; G2=0.40 +/- 0.1 N), the passive force (G1=1.1 +/- 0.2 N; G2=1.1 +/- 0.3 N) and the vaginal cavity aperture (G1=21 +/- 3 mm; G2=24 +/- 4 mm) did not differ between groups 1 and 2. Conclusion: The function evaluation of PFM showed that women with SUI had a lower anteroposterior active strength compared to continent women.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A template-based lamination technique for the manufacture of ferroelectrets from uniform electret films was recently reported. In the present work, this technique is used to prepare similar ferroelectret structures from low-density polyethylene (LDPE) films and from fluoro-ethylene-propylene (FEP) copolymer films. A comparative analysis of the pressure-, temperature-, and frequency-dependent piezoelectric properties has been performed on the two ferroelectret systems. It is observed that the FEP ferroelectrets exhibit better piezoelectric responses and are thermally more stable. The difference between the piezoelectric d(33) coefficients of the two ferroelectret systems is partially explained here by their different elastic moduli. The anti-resonance peaks of both structures have been investigated by means of dielectric resonance spectroscopy and electroacoustic sound-pressure measurements. A difference of more than 10 kHz is observed between the anti-resonance frequencies of the two ferroelectret systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Metabolic Syndrome (MetS) is associated with increased risk of morbi-mortality, thus the characterization of the population magnitude of this syndrome is critical for allocating health care. However, prevalence estimates of MetS in the same population could differ depending on the definition used. Therefore, we compared the prevalence of the MetS using definitions proposed by: National Cholesterol Education Panel Revised (NCEP) and International Diabetes Federation (IDF) 2009 in a Japanese-Brazilians community (131 individuals, age 57 ± 16 years, 1st and 2nd generation). All individuals went through a clinical and laboratorial evaluation for assessment of weigh, height, waist circumference, blood pressure, triglycerides, HDL-cholesterol and fasting plasma glucose. The prevalence of MetS was 26.7% (n = 35) and 37.4% (n = 49) under the NCEP and IDF definitions, respectively. Despite higher blood pressure measurements, waist circumference and serum triglyceride levels and lower HDL cholesterol levels (p < 0.01), individuals identified with MetS did not show increased blood glucose levels. IDF definition classified 14 individuals (10.7%) with MetS that were not classified under the NCEP and 35 individuals were identified with MetS by both criteria. We observed, in this group, more severe lipid disorders, compared to individuals identified only under the IDF definition, and the BMI and waist circumference (p = 0.01; p = 0.006, respectively) were lower. In conclusion, the IDF revised criteria, probably because of the ethnic specific values of waist circumference, was able to identify a larger number of individuals with MetS. However, our data suggesting that additional studies are necessary to define best MetS diagnostic criteria in this population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

FUNDAMENTO: A hipertensão arterial é importante fator de risco para Doença Arterial Obstrutiva Periférica dos Membros Inferiores (DAOMI). Entretanto, a correlação entre pressão arterial e Pressão de Pulso (PP) com a gravidade da DAOMI e o prejuízo funcional decorrente dessa doença ainda não está bem estabelecida na população brasileira. OBJETIVO: Verificar se há correlação entre pressão arterial, PP, gravidade da DAOMI e capacidade funcional de pacientes com DAOMI sintomática. MÉTODOS: FORAM avaliados 65 pacientes (62,2 ± 8,1 anos; 56,9% do sexo masculino), divididos em dois grupos: pressão arterial normal (A) e elevada (B). A gravidade da DAOMI foi avaliada por meio do Índice Tornozelo-Braquial (ITB) e a capacidade funcional, pelas distâncias total e livre de dor percorridas em teste de marcha. RESULTADOS: O grupo A foi constituído por 17 (26,1%) pacientes. A Pressão Arterial Sistólica (PAS), diastólica e a PP foram, respectivamente, 125,4 ± 11,7; 74,5 ± 9,1 e 50,9 ±10,0 mmHg, para o grupo A, e 160,7 ± 19,6; 90,0 ± 12,2 e 70,7 ± 20,2 mmHg, para o grupo B. O ITB foi significativamente menor no grupo B (0,66 ± 0,12 vs 0,57 ± 0,13, p < 0,05). PAS e PP correlacionaram-se com a gravidade da DAOMI e com as distâncias percorridas em teste de marcha. Pacientes com PP > 40 mmHg percorreram menores distâncias. CONCLUSÃO: A PAS e a PP correlacionaram-se de forma significativa com as distâncias percorridas em teste de marcha, sugerindo que sejam marcardores clínicos da limitação da capacidade funcional em pacientes com DAOMI sintomática.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In fluid dynamics research, pressure measurements are of great importance to define the flow field acting on aerodynamic surfaces. In fact the experimental approach is fundamental to avoid the complexity of the mathematical models for predicting the fluid phenomena. It’s important to note that, using in-situ sensor to monitor pressure on large domains with highly unsteady flows, several problems are encountered working with the classical techniques due to the transducer cost, the intrusiveness, the time response and the operating range. An interesting approach for satisfying the previously reported sensor requirements is to implement a sensor network capable of acquiring pressure data on aerodynamic surface using a wireless communication system able to collect the pressure data with the lowest environmental–invasion level possible. In this thesis a wireless sensor network for fluid fields pressure has been designed, built and tested. To develop the system, a capacitive pressure sensor, based on polymeric membrane, and read out circuitry, based on microcontroller, have been designed, built and tested. The wireless communication has been performed using the Zensys Z-WAVE platform, and network and data management have been implemented. Finally, the full embedded system with antenna has been created. As a proof of concept, the monitoring of pressure on the top of the mainsail in a sailboat has been chosen as working example.