935 resultados para precision irrigation
Resumo:
Purpose: To assess the diagnostic accuracy of the Heidelberg Retinal Tomograph 3 (HRT3) as a screening device in comparison with the reference standard of Octopus standard automated perimetry results (SAP) combined with clinical findings. Methods: All patients underwent screening examinations and investigations within a single day. Abnormal screening results were classified as follows: The HRT3: Either "borderline" or "outside normal limits" using the global Moorfields classification (MFC); SAP and clinical exam: A mean defect > 2.4 dB or "outside normal limits" clear text analysis of SAP; and one of the following i) IOP > 21 mmHg, ii) Van Herrick < ¼, iii) cup disc ratio > 0.55, iv) optic nerve head abnormality, v) narrow iridocorneal angle or vi) evidence of peripheral anterior synechiae on gonioscopy. Results: The mean age of the participants was 59.9 years (± 14.8 [21, 91]). Twenty-three subjects (16 %) were classified as abnormal on SAP and clinical exam. The HRT3 classification had a sensitivity of 30 % (95 % CI [16 %, 51 %]) with associated specificity of 58 % (95 % CI [49 %, 66 %]). Of the sixty subjects classified as borderline or outside normal limits with the HRT MFC global result, seven subjects were also abnormal according to SAP and clinical exam. Conclusion: The results suggest that the HRT3 may not be suitable as a sole screening device; however, further investigation is necessary.
Resumo:
Precision Viticulture (PV) is a concept that is beginning to have an impact on the wine-growing sector. Its practical implementation is dependant on various technological developments: crop sensors and yield monitors, local and remote sensors, Global Positioning Systems (GPS), VRA (Variable-Rate Application) equipment and machinery, Geographic Information Systems (GIS) and systems for data analysis and interpretation. This paper reviews a number of research lines related to PV. These areas of research have focused on four very specific fields: 1) quantification and evaluation of within-field variability, 2) delineation of zones of differential treatment at parcel level, based on the analysis and interpretation of this variability, 3) development of Variable-Rate Technologies (VRT) and, finally, 4) evaluation of the opportunities for site-specific vineyard management. Research in these fields should allow winegrowers and enologists to know and understand why yield variability exists within the same parcel, what the causes of this variability are, how the yield and its quality are interrelated and, if spatial variability exists, whether site-specific vineyard management is justifiable on a technical and economic basis.
Resumo:
In the ornamental plant production region of Girona (Spain), which is one of the largest of its kind in southern Europe, most of the surface is irrigated using wide blocked-end furrows. The objectives of this paper were: (1) to evaluate the irrigation scheduling methods used by ornamental plant producers; (2) to analyse different scenarios in order to assess how they affect irrigation performance; (3) to evaluate the risk of deep percolation; and (4) to calculate gross water productivity. A two-year study in a representative commercial field, planted with Prunus cerasifera ‘Nigra’, was carried out. The irrigation dose applied by the farmers was slightly smaller than the required water dose estimated by the use of two different methods: the first based on soil water content, and the second based on evapotranspiration. Distribution uniformity and application eff iciency were high, with mean values above 87%. Soil water content measurements revealed that even at the end of the furrow, where the infiltrated water depth was greatest, more than 90% of the infiltrated water was retained in the shallowest 40 cm of the soil; accordingly, the risk of water loss due to deep percolation was minimal. Gross water productivity for ornamental tree production was € 11.70 m–3, approximately 20 times higher than that obtained with maize in the same region.
Resumo:
The high cost of feed ingredients, the use of non-renewable sources of phosphate and the dramatic increase in the environmental load resulting from the excessive land application of manure are major challenges for the livestock industry. Precision feeding is proposed as an essential approach to improve the utilization of dietary nitrogen, phosphorus and other nutrients and thus reduce feeding costs and nutrient excretion. Precision feeding requires accurate knowledge of the nutritional value of feedstuffs and animal nutrient requirements, the formulation of diets in accordance with environmental constraints, and the gradual adjustment of the dietary nutrient supply to match the requirements of the animals. After the nutritional potential of feed ingredients has been precisely determined and has been improved by the addition of enzymes (e.g. phytases) or feed treatments, the addition of environmental objectives to the traditional feed formulation algorithms can promote the sustainability of the swine industry by reducing nutrient excretion in swine operations with small increases in feeding costs. Increasing the number of feeding phases can also contribute to significant reductions in nutrient excretion and feeding costs. However, the use of precision feeding techniques in which pigs are fed individually with daily tailored diets can further improve the efficiency with which pigs utilize dietary nutrients. Precision feeding involves the use of feeding techniques that allow the provision of the right amount of feed with the right composition at the right time to each pig in the herd. Using this approach, it has been estimated that feeding costs can be reduced by more than 4.6%, and nitrogen and phosphorus excretion can both be reduced by more than 38%. Moreover, the integration of precision feeding techniques into large-group production systems can provide real-time off-farm monitoring of feed and animals for optimal slaughter and production strategies, thus improving the environmental sustainability of pork production, animal well-being and meat-product quality.
Resumo:
Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.
Resumo:
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.
Resumo:
Irrigated agriculture has come under close scrutiny in Europe recently because of its high share of total water consumption and its apparent inefficiency. Several water policies have been advocated, in particular the use of economic instruments such as water markets. This paper simulates the impact of a policy based upon water markets on agricultural production in the internal river basins of Catalonia (Spain). This zone presents certain particularities that make it very interesting to study: competition between sectors for the resource (agriculture-urban consumption-recreational uses), recent periods of resource insufficiency and conflicts between irrigators as a result of the measures taken by the hydraulic administration in drought situations. The results show that these markets would guarantee an optimal reassignment of the resource in situations of supply restrictions, and although compared to the situation without markets they would not mean higher economic profits for the irrigators, they could prevent conflicts between them. Nevertheless, doubts exist about their acceptance by irrigators
Resumo:
The velocity of dripline flushing in subsurface drip irrigation (SDI) systems affects system design, cost, management, performance, and longevity. A 30‐day field study was conducted at Kansas State University to analyze the effect of four targeted flushing velocities (0.23, 0.30, 0.46, and 0.61 m/s) for a fixed 15 min duration of flushing and three flushing frequencies (no flushing or flushing every 15 or 30 days) on SDI emitter discharge and sediments within the dripline and removed in the flushing water. At the end of the field experiment (371 h), the amount of solids carried away by the flushing water and retained in every lateral were determined as well as laboratory determination of emitter discharge for every single emitter within each dripline. Greater dripline flushing velocities, which also resulted in greater flushing volumes, tended to result in greater amounts of solids in the flushing water, but the differences were not always statistically significant. Neither the frequency of flushing nor the interaction of flushing frequency and velocity significantly affected the amount of solids in the flushing water. There was a greater concentration of solids in the beginning one‐third of the 90 m laterals, particularly for treatments with no flushing or with slower dripline flushing velocities. As flushing velocity and concurrently flushing volume increased, there was a tendency for greater solids removal and/or more equal distribution within the dripline. At the end of the field study, the average emitter discharge as measured in the laboratory for a total of 3970 emitters was 0.64 L/h. which was significantly less (approximately 2.5%) than the discharge for new and unused emitters. Only six emitters were nearly or fully clogged, with discharges between 0% and 5% of new and unused emitters. Flushing velocity and flushing frequency did not have consistent significant effects on emitter discharge, and those numerical differences that did exist were small (<3%). Emitter discharge was approximately 3% less for the distal ends of the driplines (last 20% of the dripline). Although not a specific factor in the study, the results of solids removals during flushing and solids retention within the different dripline sections suggest that duration of flushing may be a more cost‐effective management option than increasing the dripline flushing velocity through SDI system design. Finally, although microirrigation system components have been improved over the years, the need for flushing to remove solids and reduce clogging potential has not been eliminated
Resumo:
Emitter spacings of 0.3 to 0.6 m are commonly used for subsurface drip irrigation (SDI) of corn on the deep, silt loam soils of the U.S. Great Plains. Subsurface drip irrigation emitter spacings of 0.3, 0.6, 0.9 and 1.2 m were examined for the resulting differences in soil water redistribution, corn grain yield, yield components, seasonal water use, and water productivity in a 4‐year field study (2005 through 2008) at the Kansas State University Northwest Research‐Extension Center, Colby, Kansas. The results indicate that there is increased preferential water movement along the dripline (parallel) as compared to perpendicular to the dripline and that this phenomenon partially compensates for wider emitter spacings in terms of soil water redistribution. Corn yield and water productivity (WP) were not significantly affected by the emitter spacing with application of a full irrigation regime
Resumo:
Chromogenic immunohistochemistry (IHC) is omnipresent in cancer diagnosis, but has also been criticized for its technical limit in quantifying the level of protein expression on tissue sections, thus potentially masking clinically relevant data. Shifting from qualitative to quantitative, immunofluorescence (IF) has recently gained attention, yet the question of how precisely IF can quantify antigen expression remains unanswered, regarding in particular its technical limitations and applicability to multiple markers. Here we introduce microfluidic precision IF, which accurately quantifies the target expression level in a continuous scale based on microfluidic IF staining of standard tissue sections and low-complexity automated image analysis. We show that the level of HER2 protein expression, as continuously quantified using microfluidic precision IF in 25 breast cancer cases, including several cases with equivocal IHC result, can predict the number of HER2 gene copies as assessed by fluorescence in situ hybridization (FISH). Finally, we demonstrate that the working principle of this technology is not restricted to HER2 but can be extended to other biomarkers. We anticipate that our method has the potential of providing automated, fast and high-quality quantitative in situ biomarker data using low-cost immunofluorescence assays, as increasingly required in the era of individually tailored cancer therapy.
Resumo:
Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.
Resumo:
[cat] Mentre que una creixent literatura que ha examinat la relació entre la renda i la despesa sanitària suggereix que els serveis sanitaris són un be de luxe (elasticitat renda superior a la unitat), aquesta conclusió es contínuament debatuda atesa l'heterogeneïtat dels resultats. Aquest article testa la hipòtesis dels serveis sanitaris com bens de luxe fent server anàlisi de meta- regressió, particularment analitzant l'existència de biaixos de selecció de publicació, precisió així com biaixos d'agregació. Els resultats apunten l'existència d'un biaix de publicació, robust independentment dels controls analitzats. Els biaixos de precisió i agregació semblen tenir un paper en la generació de les estimacions de l'elasticitat renda. Els nostres resultat suggereixen que l'elasticitat renda dels serveis sanitaris un cop corregir pels biaixos esmentat varien entre 0.26 i 0.84, però no podem rebutjar que la elasticitat renda es igual a la unitat en algunes estimacions de l'elasticitat corregides.
Resumo:
[cat] Mentre que una creixent literatura que ha examinat la relació entre la renda i la despesa sanitària suggereix que els serveis sanitaris són un be de luxe (elasticitat renda superior a la unitat), aquesta conclusió es contínuament debatuda atesa l'heterogeneïtat dels resultats. Aquest article testa la hipòtesis dels serveis sanitaris com bens de luxe fent server anàlisi de meta- regressió, particularment analitzant l'existència de biaixos de selecció de publicació, precisió així com biaixos d'agregació. Els resultats apunten l'existència d'un biaix de publicació, robust independentment dels controls analitzats. Els biaixos de precisió i agregació semblen tenir un paper en la generació de les estimacions de l'elasticitat renda. Els nostres resultat suggereixen que l'elasticitat renda dels serveis sanitaris un cop corregir pels biaixos esmentat varien entre 0.26 i 0.84, però no podem rebutjar que la elasticitat renda es igual a la unitat en algunes estimacions de l'elasticitat corregides.