985 resultados para power lines


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nomadic Narratives, Visual Forces explores issues, questions, and problems emerging in the analysis of epistolary and visual narratives. This book focuses in particular on Gwen John's letters and paintings. It offers an innovative theoretical approach to narrative analysis by drawing on Foucault's theory of power, Deleuze and Guattari's analytics of desire, and Cavarero's concept of the narratable self. Furthermore, it examines the use of letters as documents of life in narrative research and highlights the dynamics of spatiality in the constitution of the female self in art. This study brings together theoretical insights that emerge from the analysis of life documents - some of them previously unpublished - combining innovative research with specific methodological suggestions on doing narrative analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer vision for realtime applications requires tremendous computational power because all images must be processed from the first to the last pixel. Ac tive vision by probing specific objects on the basis of already acquired context may lead to a significant reduction of processing. This idea is based on a few concepts from our visual cortex (Rensink, Visual Cogn. 7, 17-42, 2000): (1) our physical surround can be seen as memory, i.e. there is no need to construct detailed and complete maps, (2) the bandwidth of the what and where systems is limited, i.e. only one object can be probed at any time, and (3) bottom-up, low-level feature extraction is complemented by top-down hypothesis testing, i.e. there is a rapid convergence of activities in dendritic/axonal connections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Catastrophic events, such as wars and terrorist attacks, tornadoes and hurricanes, earthquakes, tsunamis, floods and landslides, are always accompanied by a large number of casualties. The size distribution of these casualties has separately been shown to follow approximate power law (PL) distributions. In this paper, we analyze the statistical distributions of the number of victims of catastrophic phenomena, in particular, terrorism, and find double PL behavior. This means that the data sets are better approximated by two PLs instead of a single one. We plot the PL parameters, corresponding to several events, and observe an interesting pattern in the charts, where the lines that connect each pair of points defining the double PLs are almost parallel to each other. A complementary data analysis is performed by means of the computation of the entropy. The results reveal relationships hidden in the data that may trigger a future comprehensive explanation of this type of phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Työn tilaajana toimi Visedo Oy. Työn tavoitteina oli tutkia Visedo Oy:n ohjelmistokehityksen nykytila, tunnistaa seuraavat parannuskohteet ja antaa ohjeita havaittujen parannuskohteiden korjaamiseksi. Visedo Oy:n tehonmuokkain ohjelmistokehityksen nykytilaa käsiteltiin neljän valitun osa-alueen näkökulmasta: ohjelmistoarkkitehtuurityyli, komponenttipohjainen ohjelmistokehitys, ohjelmistotuotelinjojen kehitysmenetelmät ja ohjelmistovariaatioiden hallinta. Valituilla osa-alueilla havaittujen parannuskohteiden perusteella annettiin korjausehdotuksia: ohjelmistoarkkitehtuurin rakenteeseen, komponenttien jakautumiselle, komponenttien koostamiselle ja komponenttien versioinnille. Lisäksi ehdotettiin uudenlaista ohjelmistotuotelinja rakennetta, joka yhdistää kerros- ja komponenttipohjaiset arkkitehtuurityylit mahdollistaen ominaisuuksiltaan eroavien tehonmuokkain ohjelmistojen hallinnan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work involves investigation of a type of wireless power system wherein its analysis will yield the construction of a prototype modeled as a singular technological artifact. It is through exploration of the artifact that forms the intellectual basis for not only its prototypical forms, but suggestive of variant forms not yet discovered. Through the process it is greatly clarified the role of the artifact, its most suitable application given the constraints on the delivery problem, and optimization strategies to improve it. In order to improve maturity and contribute to a body of knowledge, this document proposes research utilizing mid-field region, efficient inductive-transfer for the purposes of removing wired connections and electrical contacts. While the description seems enough to state the purpose of this work, it does not convey the compromises of having to redraw the lines of demarcation between near and far-field in the traditional method of broadcasting. Two striking scenarios are addressed in this thesis: Firstly, the mathematical explanation of wireless power is due to J.C. Maxwell's original equations, secondly, the behavior of wireless power in the circuit is due to Joseph Larmor's fundamental works on the dynamics of the field concept. A model of propagation will be presented which matches observations in experiments. A modified model of the dipole will be presented to address the phenomena observed in the theory and experiments. Two distinct sets of experiments will test the concept of single and two coupled-modes. In a more esoteric context of the zero and first-order magnetic field, the suggestion of a third coupled-mode is presented. Through the remaking of wireless power in this context, it is the intention of the author to show the reader that those things lost to history, bound to a path of complete obscurity, are once again innovative and useful ideas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Social networks are common in digital health. A new stream of research is beginning to investigate the mechanisms of digital health social networks (DHSNs), how they are structured, how they function, and how their growth can be nurtured and managed. DHSNs increase in value when additional content is added, and the structure of networks may resemble the characteristics of power laws. Power laws are contrary to traditional Gaussian averages in that they demonstrate correlated phenomena. OBJECTIVES: The objective of this study is to investigate whether the distribution frequency in four DHSNs can be characterized as following a power law. A second objective is to describe the method used to determine the comparison. METHODS: Data from four DHSNs—Alcohol Help Center (AHC), Depression Center (DC), Panic Center (PC), and Stop Smoking Center (SSC)—were compared to power law distributions. To assist future researchers and managers, the 5-step methodology used to analyze and compare datasets is described. RESULTS: All four DHSNs were found to have right-skewed distributions, indicating the data were not normally distributed. When power trend lines were added to each frequency distribution, R(2) values indicated that, to a very high degree, the variance in post frequencies can be explained by actor rank (AHC .962, DC .975, PC .969, SSC .95). Spearman correlations provided further indication of the strength and statistical significance of the relationship (AHC .987. DC .967, PC .983, SSC .993, P<.001). CONCLUSIONS: This is the first study to investigate power distributions across multiple DHSNs, each addressing a unique condition. Results indicate that despite vast differences in theme, content, and length of existence, DHSNs follow properties of power laws. The structure of DHSNs is important as it gives insight to researchers and managers into the nature and mechanisms of network functionality. The 5-step process undertaken to compare actor contribution patterns can be replicated in networks that are managed by other organizations, and we conjecture that patterns observed in this study could be found in other DHSNs. Future research should analyze network growth over time and examine the characteristics and survival rates of superusers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The evolution of integrated circuits technologies demands the development of new CAD tools. The traditional development of digital circuits at physical level is based in library of cells. These libraries of cells offer certain predictability of the electrical behavior of the design due to the previous characterization of the cells. Besides, different versions of each cell are required in such a way that delay and power consumption characteristics are taken into account, increasing the number of cells in a library. The automatic full custom layout generation is an alternative each time more important to cell based generation approaches. This strategy implements transistors and connections according patterns defined by algorithms. So, it is possible to implement any logic function avoiding the limitations of the library of cells. Tools of analysis and estimate must offer the predictability in automatic full custom layouts. These tools must be able to work with layout estimates and to generate information related to delay, power consumption and area occupation. This work includes the research of new methods of physical synthesis and the implementation of an automatic layout generation in which the cells are generated at the moment of the layout synthesis. The research investigates different strategies of elements disposition (transistors, contacts and connections) in a layout and their effects in the area occupation and circuit delay. The presented layout strategy applies delay optimization by the integration with a gate sizing technique. This is performed in such a way the folding method allows individual discrete sizing to transistors. The main characteristics of the proposed strategy are: power supply lines between rows, over the layout routing (channel routing is not used), circuit routing performed before layout generation and layout generation targeting delay reduction by the application of the sizing technique. The possibility to implement any logic function, without restrictions imposed by a library of cells, allows the circuit synthesis with optimization in the number of the transistors. This reduction in the number of transistors decreases the delay and power consumption, mainly the static power consumption in submicrometer circuits. Comparisons between the proposed strategy and other well-known methods are presented in such a way the proposed method is validated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eigenvector and eigenvalue analyses are carried out for double three-phase transmission lines, studying the application of a constant and real phase-mode transformation matrix and the errors of this application to mode line models. Employing some line transposition types, exact results are obtained with a single real transformation matrix based on Clarke's matrix and line geometrical characteristics. It is shown that the proposed technique leads to insignificant errors when a nontransposed case is considered. For both cases, transposed and nontransposed, the access to the electrical values (voltage and current, for example) is provided through a simple matrix multiplication without convolution methods. Using this facility, an interesting model for transmission line analysis is obtained even though the nontransposed case errors are not eliminated. The main advantages of the model are related to the transformation matrix: single, real, frequency independent, and identical for voltage and current.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional Newton's method has been considered inadequate to obtain the maximum loading point (MLP) of power systems. It is due to the Jacobian matrix singularity at this point. However, the MLP can be efficiently computed through parameterization techniques of continuation methods. This paper presents and tests new parameterization schemes, namely the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, the reactive power at shunts (capacitor or reactor), the transmission lines power losses (real and reactive), and transmission lines power (real and reactive). Besides their clear physical meaning, which makes easier the development and application of continuation methods for power systems analysis, the main advantage of some of the proposed parameters is that its not necessary to change the parameter in the vicinity of the MLP. Studies on the new parameterization schemes performed on the IEEE 118 buses system show that the ill-conditioning problems at and near the MLP are eliminated. So, the characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a methodology to analyze electric power systems transient stability for first swing using a neural network based on adaptive resonance theory (ART) architecture, called Euclidean ARTMAP neural network. The ART architectures present plasticity and stability characteristics, which are very important for the training and to execute the analysis in a fast way. The Euclidean ARTMAP version provides more accurate and faster solutions, when compared to the fuzzy ARTMAP configuration. Three steps are necessary for the network working, training, analysis and continuous training. The training step requires much effort (processing) while the analysis is effectuated almost without computational effort. The proposed network allows approaching several topologies of the electric system at the same time; therefore it is an alternative for real time transient stability of electric power systems. To illustrate the proposed neural network an application is presented for a multi-machine electric power systems composed of 10 synchronous machines, 45 buses and 73 transmission lines. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the application of the Decentralized Modal Control method for pole placement in multimachine power systems utilizing FACTS (Flexible AC Transmission Systems), STATCOM (Static Synchronous Compensator) and UPFC (Unified Power Flow Controller) devices. For this, these devices are equipped with supplementary damping controllers, denominated POD ( Power Oscillation Damping), achieving a coordinated project with local controllers (Power System Stabilizers - PSS). Comparative analysis on the function of damping of the FACTS, STATCOM and UPFC is performed using the New England System that has 10 generators, 39 buses and 46 transmission lines. (c) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single real transformation matrices are tested as phase-mode transformation matrices of typical symmetrical systems with double three-phase and two parallel double three-phase transmission lines. These single real transformation matrices are achieved from eigenvector matrices of the mentioned systems and they are based on Clarke's matrix. Using linear combinations of the Clarke's matrix elements, the techniques applied to the single three-phase lines are extended to systems with 6 or 12 phase conductors. For transposed double three-phase lines, phase Z and Y matrices are changed into diagonal matrices in mode domain. Considering non-transposed cases of double three-phase lines, the results are not exact and the error analyses are performed using the exact eigenvalues. In case of two parallel double three-phase lines, the exact single real transformation matrix has not been obtained yet. Searching for this exact matrix, the analyses are based on a single homopolar reference. For all analyses in this paper, the homopolar mode is used as the only homopolar reference for all phase conductors of the studied system. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)