947 resultados para peak performance
Resumo:
This paper assesses the impact of the location and configuration of Battery Energy Storage Systems (BESS) on Low-Voltage (LV) feeders. BESS are now being deployed on LV networks by Distribution Network Operators (DNOs) as an alternative to conventional reinforcement (e.g. upgrading cables and transformers) in response to increased electricity demand from new technologies such as electric vehicles. By storing energy during periods of low demand and then releasing that energy at times of high demand, the peak demand of a given LV substation on the grid can be reduced therefore mitigating or at least delaying the need for replacement and upgrade. However, existing research into this application of BESS tends to evaluate the aggregated impact of such systems at the substation level and does not systematically consider the impact of the location and configuration of BESS on the voltage profiles, losses and utilisation within a given feeder. In this paper, four configurations of BESS are considered: single-phase, unlinked three-phase, linked three-phase without storage for phase-balancing only, and linked three-phase with storage. These four configurations are then assessed based on models of two real LV networks. In each case, the impact of the BESS is systematically evaluated at every node in the LV network using Matlab linked with OpenDSS. The location and configuration of a BESS is shown to be critical when seeking the best overall network impact or when considering specific impacts on voltage, losses, or utilisation separately. Furthermore, the paper also demonstrates that phase-balancing without energy storage can provide much of the gains on unbalanced networks compared to systems with energy storage.
Resumo:
At the beginning of the Medieval Climate Anomaly, in the ninth and tenth century, the medieval eastern Roman empire, more usually known as Byzantium, was recovering from its early medieval crisis and experiencing favourable climatic conditions for the agricultural and demographic growth. Although in the Balkans and Anatolia such favourable climate conditions were prevalent during the eleventh century, parts of the imperial territories were facing significant challenges as a result of external political/military pressure. The apogee of medieval Byzantine socio-economic development, around AD 1150, coincides with a period of adverse climatic conditions for its economy, so it becomes obvious that the winter dryness and high climate variability at this time did not hinder Byzantine society and economy from achieving that level of expansion. Soon after this peak, towards the end of the twelfth century, the populations of the Byzantine world were experiencing unusual climatic conditions with marked dryness and cooler phases. The weakened Byzantine socio-political system must have contributed to the events leading to the fall of Constantinople in AD 1204 and the sack of the city. The final collapse of the Byzantine political control over western Anatolia took place half century later, thus contemporaneous with the strong cooling effect after a tropical volcanic eruption in AD 1257. We suggest that, regardless of a range of other influential factors, climate change was also an important contributing factor to the socio-economic changes that took place in Byzantium during the Medieval Climate Anomaly. Crucially, therefore, while the relatively sophisticated and complex Byzantine society was certainly influenced by climatic conditions, and while it nevertheless displayed a significant degree of resilience, external pressures as well as tensions within the Byzantine society more broadly contributed to an increasing vulnerability in respect of climate impacts. Our interdisciplinary analysis is based on all available sources of information on the climate and society of Byzantium, that is textual (documentary), archaeological, environmental, climate and climate model-based evidence about the nature and extent of climate variability in the eastern Mediterranean. The key challenge was, therefore, to assess the relative influence to be ascribed to climate variability and change on the one hand, and on the other to the anthropogenic factors in the evolution of Byzantine state and society (such as invasions, changes in international or regional market demand and patterns of production and consumption, etc.). The focus of this interdisciplinary
Resumo:
Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.
Resumo:
In this study we assessed the mechanical function of isolated left ventricular papillary muscles from 60 day-old male Wistar-Kyoto rats (WKY) subjected to different periods of food restriction (FR). The food-restricted animals (R) were fed 50% of the amount of diet consumed by the ad Libitum-fed rats (C). The cardiac muscles were studied after 30, 60, and 90 days (R-30, R-60 and R-90) of FR. The effect of FR on myocardial collagen concentration was also evaluated. The parameters from the three control groups that were statistically identical were combined and the control pool group (CP) was formed. The left ventricular weight-to-body weight ratio was lower in the R-30 and higher in the R-60 and R-90 in relation to their control groups. Hydroxyproline concentration was higher only in R-90 compared to CP and R-30. Myocardial mechanical function was the same in the C groups. The comparisons between CP and FR groups showed that: the muscles of R-30 presented increased resting tension and maximum rate of tension decline, and decreased velocity of shortening; the muscles of R-60 and R-90 groups showed a prolongation of the time to peak tension (TPT) and the time to peak shortening (TPS); and R-30 had an increased time from peak tension to 50% relaxation (RT1/2). Increases in TPT, TPS, and RT1/2 in groups R-60 and R-90 were significant in relation to R-30. In conclusion, while FR for 30 days produces disparate effects on myocardial performance, FR for 60 and 90 days prolongs the contraction period. The change of relaxation time in R-90 might be related to the increased myocardial collagen content. (C) 2001 Elsevier B.V. All rights reserved.
Resumo:
Three experiments were carried out to analyze the performance and egg quality of Japanese quails throughout the day when submitted to different lighting programs. In each experiment, birds were submitted to a period of 28 days for adaptation to the lighting program. During the following three days, each day - from 7 am to 7 pm or 9 pm - was divided into six or seven periods of two hours each, and the remaining hours corresponded to another single period. All birds were submitted to the same management practices, and received water and feed ad libitum. The experimental diet was formulated according to NRC (1994) standards. It was observed lower feed intake in the period of 9 pm to 7 am, and a higher incidence of lay from 3 pm to 7 pm, as opposite to hens, which peak of egg laying occurs during the morning. Some controversial results were found among experiments as to eggshell quality during the different periods of the day. Variation on the lighting program had little influence on the other performance and egg quality parameters.
Resumo:
This study aimed at evaluating performance and egg quality of Japanese quails fed feeds containing different corn and limestone particle sizes. A total number of 648 birds in the peak of production was distributed in a random complete block experimental design, using a 2x3 factorial arrangement (2 corn particle sizes and 3 limestone particle sizes). Birds were designated to one of two blocks, with six replicates of 18 birds each. Mean geometric diameter (MGD) values used were 0.617mm and 0.723mm (corn fine and coarse particle sizes, respectively), and 0.361mm, 0.721mm, and 0.947mm (limestone fine, intermediate and coarse particle sizes, respectively). The following treatments were applied: T1: fine corn feed, with 100% fine limestone; T2: fine corn feed, with 50% fine limestone and 50% intermediate limestone; T3: fine corn feed, with 50% fine limestone and 50% coarse limestone; T4: coarse corn feed, with 100% fine limestone; T5: coarse corn feed, with 50% fine limestone and 50% intermediate limestone; T6: coarse corn feed, with 50% fine limestone and 50% coarse limestone. The experiment lasted 112 days, consisting of 4 cycles of 28 days. No significant interaction was observed among corn and limestone particle sizes for any of the analyzed parameters. There were no significant effects (p>0.05) of the tested corn particle sizes on quail performance or egg quality. There were significant (p<0.05) isolated effects of limestone particle size only on the percentage of cracked eggs, which was reduced when birds fed 50% coarse limestone (0.947mm) and 50% fine limestone (0.361mm) as compared to those fed 100% fine limestone. Therefore, the inclusion of 50% coarse limestone (0.947mm) is recommended for quail egg production.
Resumo:
Aiming at evaluating the influence of cyclic temperatures on the performance and egg quality of Japanese quails an experiment was carried out with 480 birds after egg production peak. Birds were housed in a bioclimatic chamber with automatic temperature control that contained two rooms, one maintained at thermoneutral temperature (21 ºC) and the other adjusted for the tested cyclic temperatures (24, 27, 30, 33 and 36 ºC at a time). Each room had a battery of five floors and ten cages, with a capacity of 24 birds per cage, totaling 240 birds per battery. Birds were fed iso-nutritious and iso-caloric diets. Data obtained under the tested cyclic temperatures were compared with those obtained under thermoneutral temperature. At the end of each experimental period (14 days) performance and egg quality parameters were evaluated. A completely randomized experimental design with two treatments (thermoneutral temperature and tested temperature) and ten replicates of 24 birds each. Cyclic increases of 27 ºC and higher in environmental temperature negatively affected bird performance, with reduced feed intake and consequent reductions in egg weight and mass. A cyclic increase of the environmental temperature to 36 ºC reduced the percentage of saleable eggs and egg production.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Papoti, M., L.E.B. Martins, S.A. Cunha, A.M. Zagatto, and C.A. Gobatto. Effects of taper on swimming force and swimmer performance after an experimental ten-week training program. J. Strength Cond. Res. 21(2):538-542. 2007.- The purpose of this research was to examine how an 11-day taper after an 8.5-week experimental training cycle affected lactate levels during maximal exercise, mean force, and performance in training swimmers, independent of shaving, psychological changes, and postcompetition effects. Fourteen competition swimmers with shaved legs and torsos were recruited from the São Paulo Aquatic Federation. The training cycle consisted of a basic training period (endurance and quality phases) of 8.5 weeks, with 5,800 m·d -1 mean training volume and 6 d·wk -1 frequency; and a taper period (TP) of 1.5 weeks' duration that incorporated a 48% reduction in weekly volume without altering intensity. Attained swimming force (SF) and maximal performance over 200m maximal swim (Pmax) before and after taper were measured. After taper, SF and Pmax improved 3.6 and 1.6%, respectively (p < 0.05). There were positive correlations (p < 0.05) between SF and Pmax before (r = 0.86) and after (r = 0.83) the taper phase. Peak lactate concentrations after SF were unaltered before (6.79 ± 1.2 mM) and after (7.15 ± 1.8 mM) TP. Results showed that TP improved mean swimming velocity, but not in the same proportion as force after taper, suggesting that there are other factors influencing performance in faster swimming. © 2007 National Strength & Conditioning Association.
Resumo:
This study aimed to determine the influence of flexibility of the chair seat surface on the pressure peak and on the contact area during the execution of a task of handling an object on the seated position by individuals with spastic cerebral palsy. Ten individuals of both genders with diagnosis of spastic cerebral palsy, who had some control to voluntarily move the body and the upper limbs, participated in this study. Quantification of data was carried out in two experimental situations: (1) execution of a task of fitting with upper limbs, and with the individual placed on an adapted canvas seat; (2) execution of a task of fitting with the participant positioned on an adapted wooden seat. Data obtained were submitted to a non-parametric and descriptive statistical analysis using the Wilcoxon test. Results indicated that the use of canvas seat increased the contact area and decreased the pressure peak and the medio-lateral displacement of centre pressure on the seated posture. © 2011 Informa UK, Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim: The aim of this study was to evaluate the knee flexor and extensor torques in isometric contractions, comparing the H:Q ratios, flexibility and maximal kick between dominant (DL) and non-dominant (NDL) limb of soccer players (SG) and active people (AG)Methods: Subjects performed maximal instep kicks with each limb, flexibility tests and maximal isometric voluntary contractions of the knee flexion and extension at 45° and 90° to determine peak torque of the DL and NDLKnee flexion torque was divided by the knee extension torque to calculate torque ratios (H:Q ratio)Results: The flexibility and maximal kick in SG was significantly higher than in AG for both the DL and NDL (P<0.05)The maximal kick of DL was significantly higher than in NDL in SG (P<0.01)Knee flexion torque in SG was significantly higher than in AG in the DL (P<0.05), and the H:Q ratio was similar between AG and SGConclusion: Dominance related differences were evident in the flexor torque and maximal kick for SG, probably related to the asymmetric demand in trainings, which present no effect on the flexibility© 2013 Elsevier Masson SAS.
Resumo:
Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)