968 resultados para operating room


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Learning surgical skills in the operating room may be a challenge for medical students. Therefore, more approaches using simulation to enable students to develop their practical skills are required. OBJECTIVES: We hypothesized that (1) there would be a need for additional surgical training for medical students in the pre-final year, and (2) our basic surgery skills training program using fresh human skin would improve medical students' surgical skills. DESIGN: We conducted a preliminary survey of medical students to clarify the need for further training in basic surgery procedures. A new approach using simulation to teach surgical skills on human skin was set up. The procedural skills of 15 randomly selected students were assessed in the operating room before and after participation in the simulation, using Objective Structured Assessment of Technical Skills. Furthermore, subjective assessment was performed based on students' self-evaluation. The data were analyzed using SPSS, version 21 (SPSS, Inc., Chicago, IL). SETTING: The study took place at the Inselspital, Bern University Hospital. PARTICIPANTS: A total of 186 pre-final-year medical students were enrolled into the preliminary survey; 15 randomly selected medical students participated in the basic surgical skills training course on the fresh human skin operating room. RESULTS: The preliminary survey revealed the need for a surgical skills curriculum. The simulation approach we developed showed significant (p < 0.001) improvement for all 12 surgical skills, with mean cumulative precourse and postcourse values of 31.25 ± 5.013 and 45.38 ± 3.557, respectively. The self-evaluation contained positive feedback as well. CONCLUSION: Simulation of surgery using human tissue samples could help medical students become more proficient in handling surgical instruments before stepping into a real surgical situation. We suggest further studies evaluating our proposed teaching method and the possibility of integrating this simulation approach into the medical school curriculum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Surgical site infections (SSI) are one of the most common nosocomial infections in the United States. This study was conducted following an increase in the rate of SSI following spinal procedures at the study hospital. ^ Methods. This study examined patient and hospital associated risk factors for SSI using existing data on patients who had spinal surgery performed at the study hospital between December 2003 and August 2005. There were 59 patients with SSI identified as cases; controls were randomly selected from patients who had spinal procedures performed at the study hospital during the study period, but did not develop infection. Of the 245 original records reviewed, 5% were missing more than half the variables and were eliminated from the data set. A total of 234 patients were included in the final analysis, representing 55 cases and 179 controls. Multivariable analysis was conducted using logistic regression to control for confounding variables. ^ Results. Three variables were found to be significant risk factors for SSI in the study population: presence of comorbidities (odds ratio 3.15, 95% confidence interval 1.20 to 8.26), cut time above the population median of 100 minutes (odds ratio 2.98, 95% confidence interval 1.12 to 5.49), and use of iodine only for preoperative skin antisepsis (odds ratio 0.16, 95% confidence interval 0.06 to 0.45). Several risk factors of specific concern to the study hospital, such as operating room, hospital staff involved in the procedures and workers' compensation status, were not shown to be statistically significant. In addition, multiple factors that have been identified in prior studies, such as method of hair removal, smoking status, or incontinence, were not shown to be statistically significant in this population. ^ Conclusions. This study confirms that increased cut time is a risk for post-operative infection. Use of iodine only was found to decrease risk of infection; further study is recommended in a population with higher usage of chlorhexadine gluconate. Presence of comorbidities at the time of surgery was also found to be a risk factor for infection; however, specific comorbidities were not studied. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Automatic analysis of minimally invasive surgical (MIS) video has the potential to drive new solutions that alleviate existing needs for safer surgeries: reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. As an unobtrusive, always available source of information in the operating room (OR), this research proposes the use of surgical video for extracting useful information during surgical operations. Methodology proposed includes tools' tracking algorithm and 3D reconstruction of the surgical field. The motivation for these solutions is the augmentation of the laparoscopic view in order to provide orientation aids, optimal surgical path visualization, or preoperative virtual models overlay

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las técnicas de cirugía de mínima invasión (CMI) se están consolidando hoy en día como alternativa a la cirugía tradicional, debido a sus numerosos beneficios para los pacientes. Este cambio de paradigma implica que los cirujanos deben aprender una serie de habilidades distintas de aquellas requeridas en cirugía abierta. El entrenamiento y evaluación de estas habilidades se ha convertido en una de las mayores preocupaciones en los programas de formación de cirujanos, debido en gran parte a la presión de una sociedad que exige cirujanos bien preparados y una reducción en el número de errores médicos. Por tanto, se está prestando especial atención a la definición de nuevos programas que permitan el entrenamiento y la evaluación de las habilidades psicomotoras en entornos seguros antes de que los nuevos cirujanos puedan operar sobre pacientes reales. Para tal fin, hospitales y centros de formación están gradualmente incorporando instalaciones de entrenamiento donde los residentes puedan practicar y aprender sin riesgos. Es cada vez más común que estos laboratorios dispongan de simuladores virtuales o simuladores físicos capaces de registrar los movimientos del instrumental de cada residente. Estos simuladores ofrecen una gran variedad de tareas de entrenamiento y evaluación, así como la posibilidad de obtener información objetiva de los ejercicios. Los diferentes estudios de validación llevados a cabo dan muestra de su utilidad; pese a todo, los niveles de evidencia presentados son en muchas ocasiones insuficientes. Lo que es más importante, no existe un consenso claro a la hora de definir qué métricas son más útiles para caracterizar la pericia quirúrgica. El objetivo de esta tesis doctoral es diseñar y validar un marco de trabajo conceptual para la definición y validación de entornos para la evaluación de habilidades en CMI, en base a un modelo en tres fases: pedagógica (tareas y métricas a emplear), tecnológica (tecnologías de adquisición de métricas) y analítica (interpretación de la competencia en base a las métricas). Para tal fin, se describe la implementación práctica de un entorno basado en (1) un sistema de seguimiento de instrumental fundamentado en el análisis del vídeo laparoscópico; y (2) la determinación de la pericia en base a métricas de movimiento del instrumental. Para la fase pedagógica se diseñó e implementó un conjunto de tareas para la evaluación de habilidades psicomotoras básicas, así como una serie de métricas de movimiento. La validación de construcción llevada a cabo sobre ellas mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. Adicionalmente, los resultados obtenidos en la validación de apariencia fueron en general positivos en todos los grupos considerados (noveles, residentes, expertos). Para la fase tecnológica, se introdujo el EVA Tracking System, una solución para el seguimiento del instrumental quirúrgico basado en el análisis del vídeo endoscópico. La precisión del sistema se evaluó a 16,33ppRMS para el seguimiento 2D de la herramienta en la imagen; y a 13mmRMS para el seguimiento espacial de la misma. La validación de construcción con una de las tareas de evaluación mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. La validación concurrente con el TrEndo® Tracking System por su parte presentó valores altos de correlación para 8 de las 9 métricas analizadas. Finalmente, para la fase analítica se comparó el comportamiento de tres clasificadores supervisados a la hora de determinar automáticamente la pericia quirúrgica en base a la información de movimiento del instrumental, basados en aproximaciones lineales (análisis lineal discriminante, LDA), no lineales (máquinas de soporte vectorial, SVM) y difusas (sistemas adaptativos de inferencia neurodifusa, ANFIS). Los resultados muestran que en media SVM presenta un comportamiento ligeramente superior: 78,2% frente a los 71% y 71,7% obtenidos por ANFIS y LDA respectivamente. Sin embargo las diferencias estadísticas medidas entre los tres no fueron demostradas significativas. En general, esta tesis doctoral corrobora las hipótesis de investigación postuladas relativas a la definición de sistemas de evaluación de habilidades para cirugía de mínima invasión, a la utilidad del análisis de vídeo como fuente de información y a la importancia de la información de movimiento de instrumental a la hora de caracterizar la pericia quirúrgica. Basándose en estos cimientos, se han de abrir nuevos campos de investigación que contribuyan a la definición de programas de formación estructurados y objetivos, que puedan garantizar la acreditación de cirujanos sobradamente preparados y promocionen la seguridad del paciente en el quirófano. Abstract Minimally invasive surgery (MIS) techniques have become a standard in many surgical sub-specialties, due to their many benefits for patients. However, this shift in paradigm implies that surgeons must acquire a complete different set of skills than those normally attributed to open surgery. Training and assessment of these skills has become a major concern in surgical learning programmes, especially considering the social demand for better-prepared professionals and for the decrease of medical errors. Therefore, much effort is being put in the definition of structured MIS learning programmes, where practice with real patients in the operating room (OR) can be delayed until the resident can attest for a minimum level of psychomotor competence. To this end, skills’ laboratory settings are being introduced in hospitals and training centres where residents may practice and be assessed on their psychomotor skills. Technological advances in the field of tracking technologies and virtual reality (VR) have enabled the creation of new learning systems such as VR simulators or enhanced box trainers. These systems offer a wide range of tasks, as well as the capability of registering objective data on the trainees’ performance. Validation studies give proof of their usefulness; however, levels of evidence reported are in many cases low. More importantly, there is still no clear consensus on topics such as the optimal metrics that must be used to assess competence, the validity of VR simulation, the portability of tracking technologies into real surgeries (for advanced assessment) or the degree to which the skills measured and obtained in laboratory environments transfer to the OR. The purpose of this PhD is to design and validate a conceptual framework for the definition and validation of MIS assessment environments based on a three-pillared model defining three main stages: pedagogical (tasks and metrics to employ), technological (metric acquisition technologies) and analytical (interpretation of competence based on metrics). To this end, a practical implementation of the framework is presented, focused on (1) a video-based tracking system and (2) the determination of surgical competence based on the laparoscopic instruments’ motionrelated data. The pedagogical stage’s results led to the design and implementation of a set of basic tasks for MIS psychomotor skills’ assessment, as well as the definition of motion analysis parameters (MAPs) to measure performance on said tasks. Validation yielded good construct results for parameters such as time, path length, depth, average speed, average acceleration, economy of area and economy of volume. Additionally, face validation results showed positive acceptance on behalf of the experts, residents and novices. For the technological stage the EVA Tracking System is introduced. EVA provides a solution for tracking laparoscopic instruments from the analysis of the monoscopic video image. Accuracy tests for the system are presented, which yielded an average RMSE of 16.33pp for 2D tracking of the instrument on the image and of 13mm for 3D spatial tracking. A validation experiment was conducted using one of the tasks and the most relevant MAPs. Construct validation showed significant differences for time, path length, depth, average speed, average acceleration, economy of area and economy of volume; especially between novices and residents/experts. More importantly, concurrent validation with the TrEndo® Tracking System presented high correlation values (>0.7) for 8 of the 9 MAPs proposed. Finally, the analytical stage allowed comparing the performance of three different supervised classification strategies in the determination of surgical competence based on motion-related information. The three classifiers were based on linear (linear discriminant analysis, LDA), non-linear (support vector machines, SVM) and fuzzy (adaptive neuro fuzzy inference systems, ANFIS) approaches. Results for SVM show slightly better performance than the other two classifiers: on average, accuracy for LDA, SVM and ANFIS was of 71.7%, 78.2% and 71% respectively. However, when confronted, no statistical significance was found between any of the three. Overall, this PhD corroborates the investigated research hypotheses regarding the definition of MIS assessment systems, the use of endoscopic video analysis as the main source of information and the relevance of motion analysis in the determination of surgical competence. New research fields in the training and assessment of MIS surgeons can be proposed based on these foundations, in order to contribute to the definition of structured and objective learning programmes that guarantee the accreditation of well-prepared professionals and the promotion of patient safety in the OR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivos: Evaluar las percepciones, opiniones y conductas que tienen enfermeros y auxiliares de enfermería sobre seguridad del paciente en el servicio quirúrgico de un hospital público del Sistema Nacional de Salud español. Describir fortalezas y debilidades/oportunidades de mejora según criterios de la Agency for Healthcare Research and Quality y conocer el número de incidentes de seguridad notificados. Método: Estudio observacional, transversal, llevado a cabo utilizando la versión española del cuestionario Hospital Survey on Patient Safety Culture. La muestra estuvo constituida por profesionales de enfermería que aceptaron participar en el estudio voluntariamente y cumplían los criterios de selección. Se realizó un análisis descriptivo e inferencial en función de la naturaleza de las variables y las condiciones de aplicación de los test estadísticos. Significación p < 0,05. Resultados: Respondieron 74 profesionales de enfermería (63,2%). No se encontró ninguna fortaleza en el servicio quirúrgico, y las áreas principales que necesitan mejora corresponden a «Dotación de personal» (64,0%) y «Apoyo de la gerencia del hospital en materia de seguridad del paciente» (52,9%). El 52,3% (n = 65) califica el grado de seguridad del paciente entre 7 y 8,99 (en una escala de 10); el 79,7% (n = 72) no notificó ningún incidente durante el último año. La varianza total explicada por el modelo de regresión fue 0,56 para «Frecuencia de eventos notificados» y 0,26 para «Percepción de seguridad». Conclusiones: Percepción más positiva sobre cultura de seguridad del paciente a nivel de unidad/servicio. Las debilidades identificadas pueden servir para diseñar actividades concretas de intervención para mejorar la cultura de seguridad del paciente en otros servicios quirúrgicos del entorno.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El objetivo del presente estudio es describir y comparar los porcentajes de no cumplimentación de dos instrumentos de registro: hoja circulante (HC) y lista de verificación quirúrgica (LVQ), en un mismo entorno quirúrgico para una muestra de pacientes de características similares. Metodología: Estudio descriptivo realizado sobre registros intraquirúrgicos de 3024 pacientes de Cirugía de Ortopedia y Traumatología. 1732 pacientes intervenidos en 2009 con modelo de hoja circulante, cumplimentada al finalizar la intervención y 1292 en 2010 intervenidos con modelo de registro lista de verificación quirúrgica (checklist) cumplimentado durante la intervención en tres tiempos. Se han calculado características descriptivas (media, desviación típica, mínimo y máximo) del porcentaje de no cumplimentación global en ambos registros y el porcentaje de no cumplimentación (intervalo de confianza al 95%) de cada ítem de los registros estudiados. Resultados: Se observa mayor porcentaje de cumplimentación global y, en general, también individual, en la hoja circulante que en la lista de verificación quirúrgica. Conclusiones: El registro intraquirúrgico que mayor porcentaje de cumplimentación ha tenido de manera global ha sido la hoja de circulante y se evidencia la necesidad de implantar estrategias para mejorar el grado de cumplimentación de la LVQ por su relación con la seguridad de pacientes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction : The acute care surgery (ACS) units are dedicated to the prompt management of surgical emergencies. It is a systemic way of organizing on-call services to diminish conflict between urgent care and elective obligations. The aim of this study was to define the characteristics of an ACS unit and to find common criteria in units with reported good functioning. Methods : As of July 1st 2014, 22 Canadian hospitals reported having an ACS unit. A survey with questions about the organization of the ACS units, the population it serves, the number of emergencies and trauma cases treated per year, and the satisfaction about the implementation of this ACS unit was sent to those hospitals. Results : The survey’s response rate was 73%. The majority of hospitals were tertiary or quaternary centers, served a population of more than 200 000 and had their ACS unit for more than three years. The median number of surgeons participating in an ACS unit was 8.5 and the majority were doing seven day rotations. The median number of operating room days was 2.5 per week. Most ACS units (85%) had an estimated annual volume of more than 2500 emergency consultations (including both trauma and non-trauma) and 80% operated over 1000 cases per year. Nearly all the respondents (94%) were satisfied with the implementation of the ACS unit in their hospital. Conclusion : Most surgeons felt that the implementation of an ACS unit resulted in positive outcomes. However, there should be a sizeable catchment population and number of surgical emergencies to justify the resulting financial and human resources.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In questa tesi è stato analizzato e tradotto nel linguaggio di alto livello AMPL un modello di ILP relativo alla pianificazione tattica del blocco operatorio. L'obiettivo è quello di permettere l'interfacciamento con numerosi solver -commerciali e non- al fine di analizzarne le prestazioni. In seguito a un'introduzione in merito al problema dell'Operating Room Management e a una descrizione del contesto sanitario regionale dell'Emilia-Romagna, si è proceduto alla descrizione formale del modello. Infine sono state eseguite numerose risoluzioni con i solver cplex e gurobi al variare di alcuni parametri in ingresso, tra cui il numero di sale operatorie, di infermieri e operatori sanitari, e di pazienti in lista d'attesa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Agency partners: Illinois State Board of Education, Illinois Community College Board, Illinois Board of Higher Education, Illinois Dept. of Commerce and Community Affairs, Illinois Dept. of Employment Security.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Regional anesthesia is an established method to provide analgesia for patients in the operating room and during the postoperative phase. While regional anesthesia offers unique advantages, as shown by the recent military experience, it is not commonly utilized in the prehospital or emergency department setting. Most often, regional anesthesia techniques for traumatized patients are first utilized in the operating room for procedural anesthesia or for postoperative pain control. While infiltration or single nerve block procedures are often used by surgeons or emergency medicine physicians in the preoperative phase, more advanced techniques such as plexus block procedures or regional catheter placements are more commonly performed by anesthesiologists for surgery or postoperative pain control. These regional techniques offer advantages over intravenous anesthesia, not just in the perioperative phase but also in the acute phase of traumatized patients and during the initial transport of injured patients. Anesthesiologists have extensive experience with regional techniques and are able to introduce regional anesthesia into settings outside the operating room and in the early treatment phases of trauma patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We reviewed the use of advanced display technologies for monitoring in anesthesia. Researchers are investigating displays that integrate information and that, in some cases, also deliver the results continuously to the anesthesiologist. Integrated visual displays reveal higher-order properties of patient state and speed in responding to events, but their benefits under an intensely timeshared load is unknown. Head-mounted displays seem to shorten the time to respond to changes, but their impact on peripheral awareness and attention is unknown. Continuous auditory displays extending pulse oximetry seem to shorten response times and improve the ability to time-share other tasks, but their integration into the already noisy operative environment still needs to be tested. We reviewed the advantages and disadvantages of the three approaches, drawing on findings from other fields, such as aviation, to suggest outcomes where there are still no results for the anesthesia context. Proving that advanced patient monitoring displays improve patient outcomes is difficult, and a more realistic goal is probably to prove that such displays lead to better situational awareness, earlier responding, and less workload, all of which keep anesthesia practice away from the outer boundaries of safe operation.