962 resultados para laser interferometry-based guidance


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper a photogrammetric method is proposed for refining 3D building roof contours extracted from airborne laser scanning data. It is assumed that laser-derived planar faces of roofs are potentially accurate, while laser-derived building roof contours are not well defined. First, polygons representing building roof contours are extracted from a high-resolution aerial image. In the sequence, straight-line segments delimitating each building roof polygon are projected onto the corresponding laser-derived roof planes by using a new line-based photogrammetric model. Finally, refined 3D building roof contours are reconstructed by connecting every pair of photogrammetrically- projected adjacent straight lines. The obtained results showed that the proposed approach worked properly, meaning that the integration of image data and laser scanning data allows better results to be obtained, when compared to the results generated by using only laser scanning data. © 2013 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy. Method This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival). Results In total, 16 fetuses with congenital lung lesions underwent invasive percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p?=?0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p?<?0.01). Conclusion Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. (C) 2012 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Up-regulation of stress-activated proteins in cancer cells plays a protective role against photodynamic induced apoptosis. Post photodynamic therapy extracted normal rat liver tissue usually shows a fraction of surviving cells, the photodynamic resistant cells, residing in the necrotic region. To treat these photo-dynamic resistant cells a technique has been proposed based on fractionated drug administration of diluted photosensitizer, keeping the net concentration (5 mg/kg) constant, and subsequently varying drug light interval (DLI). Flourescence measurements were made for the presence of photosensitizer in a tissue. For qualitative analysis both histological and morphological studies were made. Although preliminary aim of this approach was not achieved but there were some interesting observation made i.e. for higher dilution of photosensitizer there was a sharp boundary between necrotic and normal portion of tissue. An increase in the absorption coefficient (alpha) from 2.7 -> 2.9 was observed as photosensitizer was diluted while the corresponding threshold dose (D (th)) persistently decreases from (0.10 -> 0.02) J/cm(2) when irradiated with a 635 nm laser fluence of 150 J/cm(2).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

During the last decades magnetic circular dichroism (MCD) has attracted much interest and evolved into various experimental methods for the investigation of magnetic thin films. For example, synchrotron-based X-ray magnetic circular dichroism (XMCD) displays the absolute values of spin and orbital magnetic moments. It thereby benefits from large asymmetry values of more than 30% due to the excitation of atomic core-levels. Similarly large values are also expected for threshold photoemission magnetic circular dichroism (TPMCD). Using lasers with photon energies in the range of the sample work function this method gives access to the occupied electronic structure close to the Fermi level. However, except for the case of Ni(001) there exist only few studies on TPMCD moreover revealing much smaller asymmetries than XMCD-measurements. Also the basic physical mechanisms of TPMCD are not satisfactorily understood. In this work we therefore investigate TPMCD in one- and two-photon photoemission (1PPE and 2PPE) for ferromagnetic Heusler alloys and ultrathin Co films using ultrashort pulsed laser light. The observed dichroism is explained by a non-conventional photoemission model using spin-resolved band-structure calculations and linear response theory. For the two Heusler alloys Ni2MnGa and Co2FeSi we give first evidence of TPMCD in the regime of two-photon photoemission. Systematic investigations concerning general properties of TPMCD in 1PPE and 2PPE are carried out at ultrathin Co films grown on Pt(111). Here, photon-energy dependent measurements reveal asymmetries of 1.9% in 1PPE and 11.7% in 2PPE. TPMCD measurements at decreased work function even yield larger asymmetries of 6.2% (1PPE) and 17% (2PPE), respectively. This demonstrates that enlarged asymmetries are also attainable for the TPMCD effect on Co(111). Furthermore, we find that the TPMCD asymmetry is bulk-sensitive for 1PPE and 2PPE. This means that the basic mechanism leading to the observed dichroism must be connected to Co bulk properties; surface effects do not play a crucial role. Finally, the enhanced TPMCD asymmetries in 2PPE compared to the 1PPE case are traced back to the dominant influence of the first excitation step and the existence of a real intermediate state. The observed TPMCD asymmetries cannot be interpreted by conventional photoemission theory which only considers direct interband transitions in the direction of observation (Γ-L). For Co(111), these transitions lead to evanescent final states. The excitation to such states, however, is incompatible with the measured bulk-sensitivity of the asymmetry. Therefore, we generalize this model by proposing the TPMCD signal to arise mostly from direct interband transitions in crystallographic directions other than (Γ-L). The necessary additional momentum transfer to the excited electrons is most probably provided by electron-phonon or -magnon scattering processes. Corresponding calculations on the basis of this model are in reasonable agreement with the experimental results so that this approach represents a promising tool for a quantitative description of the TPMCD effect. The present findings encourage an implementation of our experimental technique to time- and spatially-resolved photoemission electron microscopy, thereby enabling a real time imaging of magnetization dynamics of single excited states in a ferromagnetic material on a femtosecond timescale.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Laser Shock Peening (LSP) is a surface enhancement treatment which induces a significant layer of beneficial compressive residual stresses of up to several mm underneath the surface of metal components in order to improve the detrimental effects of the crack growth behavior rate in it. The aim of this thesis is to predict the crack growth behavior in metallic specimens with one or more stripes which define the compressive residual stress area induced by the Laser Shock Peening treatment. The process was applied as crack retardation stripes perpendicular to the crack propagation direction with the object of slowing down the crack when approaching the peened stripes. The finite element method has been applied to simulate the redistribution of stresses in a cracked model when it is subjected to a tension load and to a compressive residual stress field, and to evaluate the Stress Intensity Factor (SIF) in this condition. Finally, the Afgrow software is used to predict the crack growth behavior of the component following the Laser Shock Peening treatment and to detect the improvement in the fatigue life comparing it to the baseline specimen. An educational internship at the “Research & Technologies Germany – Hamburg” department of AIRBUS helped to achieve knowledge and experience to write this thesis. The main tasks of the thesis are the following: •To up to date Literature Survey related to “Laser Shock Peening in Metallic Structures” •To validate the FE model developed against experimental measurements at coupon level •To develop design of crack growth slowdown in Centered Cracked Tension specimens based on residual stress engineering approach using laser peened strip transversal to the crack path •To evaluate the Stress Intensity Factor values for Centered Cracked Tension specimens after the Laser Shock Peening treatment via Finite Element Analysis •To predict the crack growth behavior in Centered Cracked Tension specimens using as input the SIF values evaluated with the FE simulations •To validate the results by means of experimental tests

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coastal sand dunes represent a richness first of all in terms of defense from the sea storms waves and the saltwater ingression; moreover these morphological elements constitute an unique ecosystem of transition between the sea and the land environment. The research about dune system is a strong part of the coastal sciences, since the last century. Nowadays this branch have assumed even more importance for two reasons: on one side the born of brand new technologies, especially related to the Remote Sensing, have increased the researcher possibilities; on the other side the intense urbanization of these days have strongly limited the dune possibilities of development and fragmented what was remaining from the last century. This is particularly true in the Ravenna area, where the industrialization united to the touristic economy and an intense subsidence, have left only few dune ridges residual still active. In this work three different foredune ridges, along the Ravenna coast, have been studied with Laser Scanner technology. This research didn’t limit to analyze volume or spatial difference, but try also to find new ways and new features to monitor this environment. Moreover the author planned a series of test to validate data from Terrestrial Laser Scanner (TLS), with the additional aim of finalize a methodology to test 3D survey accuracy. Data acquired by TLS were then applied on one hand to test some brand new applications, such as Digital Shore Line Analysis System (DSAS) and Computational Fluid Dynamics (CFD), to prove their efficacy in this field; on the other hand the author used TLS data to find any correlation with meteorological indexes (Forcing Factors), linked to sea and wind (Fryberger's method) applying statistical tools, such as the Principal Component Analysis (PCA).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis reports on the experimental realization of nanofiber-based spectroscopy of organic molecules. The light guided by subwavelength diameter optical nanfibers exhibits a pronounced evanescent field surrounding the fiber which yields high excitation and emission collection efficiencies for molecules on or near the fiber surface.rnThe optical nanofibers used for the experiments presented in this thesis are realized as thernsub-wavelength diameter waist of a tapered optical fiber (TOF). The efficient transfer of thernlight from the nanofiber waist to the unprocessed part of the TOF depends critically on therngeometric shape of the TOF transitions which represent a nonuniformity of the TOF. Thisrnnonuniformity can cause losses due to coupling of the fundamental guided mode to otherrnmodes which are not guided by the taper over its whole length. In order to quantify the lossrnfrom the fundamental mode due to tapering, I have solved the coupled local mode equationsrnin the approximation of weak guidance for the three layer system consisting of fiber core andrncladding as well as the surrounding vacuum or air, assuming the taper shape of the TOFsrnused for the experiments presented in this thesis. Moreover, I have empirically studied therninfluence of the TOF geometry on its transmission spectra and, based on the results, I haverndesigned a nanofiber-waist TOF with broadband transmission for experiments with organicrnmolecules.rnAs an experimental demonstration of the high sensitivity of nanofiber-based surface spectroscopy, I have performed various absorption and fluorescence spectroscopy measurements on the model system 3,4,9,10-perylene-tetracarboxylic dianhydride (PTCDA). The measured homogeneous and inhomogeneous broadening of the spectra due to the interaction of the dielectric surface of the nanofiber with the surface-adsorbed molecules agrees well with the values theoretically expected and typical for molecules on surfaces. Furthermore, the self-absorption effects due to reasorption of the emitted fluorescence light by circumjacent surface-adsorbed molecules distributed along the fiber waist have been analyzed and quantified. With time-resolved measurements, the reorganization of PTCDA molecules to crystalline films and excimers can be observed and shown to be strongly catalyzed by the presence of water on the nanofiber surface. Moreover, the formation of charge-transfer complexes due to the interaction with localized surface defects has been studied. The collection efficiency of the molecular emission by the guided fiber mode has been determined by interlaced measurements of absorption and fluorescence spectra to be about 10% in one direction of the fiber.rnThe high emission collection efficiency makes optical nanofibers a well-suited tool for experiments with dye molecules embedded in small organic crystals. As a first experimental realization of this approach, terrylene-doped para-terphenyl crystals attached to the nanofiber-waist of a TOF have been studied at cryogenic temperatures via fluorescence and fluorescence excitation spectroscopy. The statistical fine structure of the fluorescence excitation spectrum for a specific sample has been observed and used to give an estimate of down to 9 molecules with center frequencies within one homogeneous width of the laser wavelength on average for large detunings from resonance. The homogeneous linewidth of the transition could be estimated to be about 190MHz at 4.5K.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The authors describe a modification of the medial branch kryorhizotomy technique for the treatment of lumbar facet joint syndrome using a fluoroscopy-based laser-guided method. A total of 32 patients suffering from lumbar facet joint syndrome confirmed by positive medial nerve block underwent conventional or laser-guided kryorhizotomy. The procedural time (20.6 +/- 1.0 vs 16.3 +/- 0.9 minutes, p < 0.01), fluoroscopy time (54.1 +/- 3.5 vs 28.2 +/- 2.4 seconds, p < 0.01), radiation dose (407.5 +/- 32.0 vs 224.1 +/- 20.3 cGy/cm(2), p < 0.01), and patient discomfort during the procedure (7.1 +/- 0.4 vs 5.2 +/- 0.4 on the visual analog scale, p < 0.01) were significantly reduced in the laser-guided group. There was a tendency for a better positioning accuracy when the laser guidance method was used (3.0 +/- 0.3 vs 2.2 +/- 0.3 mm of deviation from the target points, p > 0.05). No difference in the outcome was observed between the 2 groups of patients (visual analog scale score 3.5 +/- 0.2 vs 3.3 +/- 0.3, p > 0.05). This improved minimally invasive surgical technique offers advantages to conventional fluoroscopy-based kryorhizotomy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To master changing performance demands, autonomous transport vehicles are deployed to make inhouse material flow applications more flexible. The socalled cellular transport system consists of a multitude of small scale transport vehicles which shall be able to form a swarm. Therefore the vehicles need to detect each other, exchange information amongst each other and sense their environment. By provision of peripherally acquired information of other transport entities, more convenient decisions can be made in terms of navigation and collision avoidance. This paper is a contribution to collective utilization of sensor data in the swarm of cellular transport vehicles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a case of successful interventional laser-assisted extraction of an endovascularly trapped long-term implanted ventriculoatrial shunt in a patient with shunt-associated septicemia. This approach is based on modified techniques for explantation of pacemaker leads and might be considered an additional option for extraction of otherwise nonremovable trapped endovascular catheters in experienced centers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.