985 resultados para intensity modulated


Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: EORTC trial 22991 was designed to evaluate the addition of concomitant and adjuvant short-term hormonal treatments to curative radiotherapy in terms of disease-free survival for patients with intermediate risk localized prostate cancer. In order to assess the compliance to the 3D conformal radiotherapy protocol guidelines, all participating centres were requested to participate in a dummy run procedure. An individual case review was performed for the largest recruiting centres as well. MATERIALS AND METHODS: CT-data of an eligible prostate cancer patient were sent to 30 centres including a description of the clinical case. The investigator was requested to delineate the volumes of interest and to perform treatment planning according to the protocol. Thereafter, the investigators of the 12 most actively recruiting centres were requested to provide data on five randomly selected patients for an individual case review. RESULTS: Volume delineation varied significantly between investigators. Dose constraints for organs at risk (rectum, bladder, hips) were difficult to meet. In the individual case review, no major protocol deviations were observed, but a number of dose reporting problems were documented for centres using IMRT. CONCLUSIONS: Overall, results of this quality assurance program were satisfactory. The efficacy of the combination of a dummy run procedure with an individual case review is confirmed in this study, as none of the evaluated patient files harboured a major protocol deviation. Quality assurance remains a very important tool in radiotherapy to increase the reliability of the trial results. Special attention should be given when designing quality assurance programs for more complex irradiation techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Depuis quelques années, il y a un intérêt de la communauté en dosimétrie d'actualiser les protocoles de dosimétrie des faisceaux larges tels que le TG-51 (AAPM) et le TRS-398 (IAEA) aux champs non standard qui requièrent un facteur de correction additionnel. Or, ces facteurs de correction sont difficiles à déterminer précisément dans un temps acceptable. Pour les petits champs, ces facteurs augmentent rapidement avec la taille de champ tandis que pour les champs d'IMRT, les incertitudes de positionnement du détecteur rendent une correction cas par cas impraticable. Dans cette étude, un critère théorique basé sur la fonction de réponse dosimétrique des détecteurs est développé pour déterminer dans quelles situations les dosimètres peuvent être utilisés sans correction. Les réponses de quatre chambres à ionisation, d'une chambre liquide, d'un détecteur au diamant, d'une diode, d'un détecteur à l'alanine et d'un détecteur à scintillation sont caractérisées à 6 MV et 25 MV. Plusieurs stratégies sont également suggérées pour diminuer/éliminer les facteurs de correction telles que de rapporter la dose absorbée à un volume et de modifier les matériaux non sensibles du détecteur pour pallier l'effet de densité massique. Une nouvelle méthode de compensation de la densité basée sur une fonction de perturbation est présentée. Finalement, les résultats démontrent que le détecteur à scintillation peut mesurer les champs non standard utilisés en clinique avec une correction inférieure à 1%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among the large number of photothcrmal techniques available, photoacoustics assumes a very significant place because of its essential simplicity and the variety of applications it finds in science and technology. The photoacoustic (PA) effect is the generation of an acoustic signal when a sample, kept inside an enclosed volume, is irradiated by an intensity modulated beam of radiation. The radiation absorbed by the sample is converted into thermal waves by nonradiative de-excitation processes. The propagating thermal waves cause a corresponding expansion and contraction of the gas medium surrounding the sample, which in tum can be detected as sound waves by a sensitive microphone. These sound waves have the same frequency as the initial modulation frequency of light. Lock-in detection method enables one to have a sufficiently high signal to noise ratio for the detected signal. The PA signal amplitude depends on the optical absorption coefficient of the sample and its thermal properties. The PA signal phase is a function of the thermal diffusivity of the sample.Measurement of the PA amplitude and phase enables one to get valuable information about the thermal and optical properties of the sample. Since the PA signal depends on the optical and thennal properties of the sample, their variation will get reflected in the PA signal. Therefore, if the PA signal is collected from various points on a sample surface it will give a profile of the variations in the optical/thennal properties across the sample surface. Since the optical and thermal properties are affected by the presence of defects, interfaces, change of material etc. these will get reflected in the PA signal. By varying the modulation frequency, we can get information about the subsurface features also. This is the basic principle of PA imaging or PA depth profiling. It is a quickly expanding field with potential applications in thin film technology, chemical engineering, biology, medical diagnosis etc. Since it is a non-destructive method, PA imaging has added advantages over some of the other imaging techniques. A major part of the work presented in this thesis is concemed with the development of a PA imaging setup that can be used to detect the presence of surface and subsmface defects in solid samples.Determination of thermal transport properties such as thermal diffusivity, effusivity, conductivity and heat capacity of materials is another application of photothennal effect. There are various methods, depending on the nature of the sample, to determine these properties. However, there are only a few methods developed to determine all these properties simultaneously. Even though a few techniques to determine the above thermal properties individually for a coating can be found in literature, no technique is available for the simultaneous measurement of these parameters for a coating. We have developed a scanning photoacoustic technique that can be used to determine all the above thermal transport properties simultaneously in the case of opaque coatings such as paints. Another work that we have presented in this thesis is the determination of thermal effusivity of many bulk solids by a scanning photoacoustic technique. This is one of the very few methods developed to determine thermal effiisivity directly.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis work has mainly concentrated on the investigation of the ,optical and thermal properties of binary semiconducting chalcogenide glasses belonging to the AivB¥5x and AZBXEX families. The technique used for these studies is a relatively new one namely, the photoacoustic (PA) technique. This technique is based on the detection of acoustic signal produced in an enclosed volume when the sample is irradiated by an intensity modulated radiation. The signal produced depends upon the optical properties of the sample, and the thermal properties of the sample, backing material and the surrounding gas. For the present studies an efficient signal beam gas-microphone PA spectrometer, consisting of a high power Xenon lamp, monochromator, light beam chopper, PA cell with microphone and lock-in amplifier, has been set up. Two PA cells have been fabricated: one for room temperature measurements and another for measurements at high temperatures. With the high temperature PA cell measurements can be taken upto 250°C. Provisions are incorporated. in both the cells to change the volume and to use different backing materials for the sample. The cells have been calibrated by measuring the frequency response of the cells using carbon black as the sample

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the preset work is to develop optical fiber sensors for various physical and chemical parameters. As a part of this we initially investigated trace analysis of silica, ammonia, iron and phosphate in water. For this purpose the author has implemented a dual wavelength probing scheme which has many advantages over conventional evanescent wave sensors. Dual wavelength probing makes the design more reliable and repeatable and this design makes the sensor employable for concentration, chemical content, adulteration level, monitoring and control in industries or any such needy environments. Use of low cost components makes the system cost effective and simple. The Dual wavelength probing scheme is employed for the trace analysis of silica, iron, phosphate, and ammonia in water. Such sensors can be employed for the steam and water quality analysers in power plants. Few samples from a power plant are collected and checked the performance of developed system for practical applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Use of orthogonal space-time block codes (STBCs) with multiple transmitters and receivers can improve signal quality. However, in optical intensity modulated signals, output of the transmitter is non-negative and hence standard orthogonal STBC schemes need to be modified. A generalised framework for applying orthogonal STBCs for free-space IM/DD optical links is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Use of orthogonal space-time block codes (STBCs) with multiple transmitters and receivers can improve signal quality. However, in optical intensity modulated signals, output of the transmitter is non-negative and hence standard orthogonal STBC schemes need to be modified. A generalised framework for applying orthogonal STBCs for free-space IM/DD optical links is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Low-density polyethylene (LDPE) was characterised for its dielectric and electrical properties before and after chemical treatment. A reduction in the permittivity and dielectric loss was observed in the polymer after treatment with hexane. The intensity in the Raman Spectrum in the disordered longitudinal acoustic mode region (DLAM) also was reduced due to a hexane treatment. Using thermally stimulated discharge current (TSDC) and laser-intensity-modulated method (LIMM) techniques it was observed that charge injection can be enhanced in the polymer matrix in the empty sites, created by the removal of the low molecular weight impurities with chemical treatment. (C) 2002 Kluwer Academic Publishers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A performance comparison between a recently proposed novel technique known as fast orthogonal frequency-division multiplexing (FOFDM) and conventional orthogonal frequency-division multiplexing (OFDM) is undertaken over unamplified, intensity-modulated, and direct-detected directly modulated laser-based optical signals. Key transceiver parameters, such as the maximum achievable transmission capacity and the digital-to-analog/analog-to-digital converter (DAC/ADC) effects are explored thoroughly. It is shown that, similarly to conventional OFDM, the least complex and bandwidth efficient FOFDM can support up to similar to 20 Gb/s over 500 m worst-case multimode fiber (MMF) links having 3 dB effective bandwidths of similar to 200 MHz X km. For compensation of the DAC/ADC roll-off, a power-loading (PL) algorithm is adopted, leading to an FOFDM system improvement of similar to 4 dB. FOFDM and conventional OFDM give similar optimum DAC/ADC parameters over 500 m worst-case MMF, while over 50 km single-mode fiber a maximum deviation of only similar to 1 dB in clipping ratio is observed due to the imperfect chromatic dispersion compensation caused by one-tap equalizers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4704496]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Obiettivo: Il nostro obiettivo è stato quello di confrontare la tomoterapia (HT) e la protonterapia ad intensità modulata (IMPT) nel trattamento del tumore prostatico, seguendo un protocollo di boost simultaneo (SIB) e moderatamente ipofrazionato. Materiali e metodi: Abbiamo selezionato 8 pazienti, trattati con HT e abbiamo rielaborato i piani con 2 campi IMPT. La dose prescritta è stata di 74 Gy sul PTV1 (prostata e vescicole seminali prossimali), 65.8 Gy sul PTV2 (vescicole seminali distali) e 54 Gy sul PTV3 (linfonodi pelvici). Risultati: Sia con IMPT che con HT abbiamo ottenuto una copertura e una omogeneità di dose del target sovrapponibile. Oltre i 65 Gy, HT e IMPT erano equivalenti per il retto, mentre con l’IMPT c’era maggior risparmio della vescica e del bulbo penieno da 0 a 70 Gy. Da 0 fino a 60 Gy, i valori dosimetrici dell’IMPT erano molto più bassi per tutti gli organi a rischio (OARs), eccetto che per le teste femorali, dove la HT aveva un vantaggio dosimetrico rispetto all’IMPT nel range di dose 25-35 Gy. La dose media agli OARs era ridotta del 30-50% con l’IMPT. Conclusioni: Con le due tecniche di trattamento (HT e IMPT) si ottiene una simile distribuzione di dose nel target. Un chiaro vantaggio dosimetrico dell’IMPT sul HT è ottenuto dalle medie e basse dosi. Le attuali conoscenze sulle relazioni dose-effetto e sul risparmio delle madie e basse dosi con l’IMPT non sono ancora state quantificate dal punto di vista clinico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Obiettivo: valutare la tossicità ed il controllo di malattia di un trattamento radioterapico ipofrazionato ad alte dosi con tecnica ad intensità modulata (IMRT) guidata dalle immagini (IGRT) in pazienti affetti da carcinoma prostatico a rischio intermedio, alto ed altissimo di recidiva. Materiali e metodi: tutti i pazienti candidati al trattamento sono stati stadiati e sottoposti al posizionamento di tre “markers” fiduciali intraprostatici necessari per l’IGRT. Mediante tecnica SIB – IMRT sono stati erogati alla prostata 67,50 Gy in 25 frazioni (EQD2 = 81 Gy), alle vescichette 56,25 Gy in 25 frazioni (EQD2 = 60,35 Gy) e ai linfonodi pelvici, qualora irradiati, 50 Gy in 25 frazioni. La tossicità gastrointestinale (GI) e genitourinaria (GU) è stata valutata mediante i CTCAE v. 4.03. Per individuare una possibile correlazione tra i potenziali fattori di rischio e la tossicità registrata è stato utilizzato il test esatto di Fisher e la sopravvivenza libera da malattia è stata calcolata mediante il metodo di Kaplan-Meier. Risultati: sono stati arruolati 71 pazienti. Il follow up medio è di 19 mesi (3-35 mesi). Nessun paziente ha dovuto interrompere il trattamento per la tossicità acuta. Il 14% dei pazienti (10 casi) ha presentato una tossicità acuta GI G ≥ 2 e il 15% (11 pazienti) ha riportato una tossicità acuta GU G2. Per quanto riguarda la tossicità tardiva GI e GU G ≥ 2, essa è stata documentata, rispettivamente, nel 14% dei casi (9 pazienti) e nell’11% (7 pazienti). Non è stata riscontrata nessuna tossicità, acuta o cronica, G4. Nessun fattore di rischio correlava con la tossicità. La sopravvivenza libera da malattia a 2 anni è del 94%. Conclusioni: il trattamento radioterapico ipofrazionato ad alte dosi con IMRT-IGRT appare essere sicuro ed efficace. Sono comunque necessari ulteriori studi per confermare questi dati ed i presupposti radiobiologici dell’ipofrazionamento del carcinoma prostatico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La radioterapia è una tecnica molto impiegata per la cura del cancro. Attualmente la somministrazione avviene principalmente attraverso la intensity modulated radiotherapy (IMRT, sovrapposizione di campi ad intensità modulata), un cui sviluppo recente è la volumetric modulated arc therapy (VMAT, irradiazione continua lungo un arco ininterrotto). La generazione di piani richiede esperienza ed abilità: un dosimetrista seleziona cost functions ed obiettivi ed un TPS ottimizza la disposizione dei segmenti ad intensità modulata. Se il medico giudica il risultato non soddisfacente, il processo riparte da capo (trial-and-error). Una alternativa è la generazione automatica di piani. Erasmus-iCycle, software prodotto presso ErasmusMC (Rotterdam, The Netherlands), è un algoritmo di ottimizzazione multicriteriale di piani radioterapici per ottimizzazione di intensità basato su una wish list. L'output consiste di piani Pareto-ottimali ad intensità modulata. La generazione automatica garantisce maggiore coerenza e qualità più elevata con tempi di lavoro ridotti. Nello studio, una procedura di generazione automatica di piani con modalità VMAT è stata sviluppata e valutata per carcinoma polmonare. Una wish list è stata generata attraverso una procedura iterativa su un gruppo ristretto di pazienti con la collaborazione di fisici medici ed oncologi e poi validata su un gruppo più ampio di pazienti. Nella grande maggioranza dei casi, i piani automatici sono stati giudicati dagli oncologi migliori rispetto ai rispettivi piani IMRT clinici generati manualmente. Solo in pochi casi una rapida calibrazione manuale specifica per il paziente si è resa necessaria per soddisfare tutti i requisiti clinici. Per un sottogruppo di pazienti si è mostrato che la qualità dei piani VMAT automatici era equivalente o superiore rispetto ai piani VMAT generati manualmente da un dosimetrista esperto. Complessivamente, si è dimostrata la possibilità di generare piani radioterapici VMAT ad alta qualità automaticamente, con interazione umana minima. L'introduzione clinica della procedura automatica presso ErasmusMC è iniziata (ottobre 2015).