911 resultados para high dynamic range phototransistor
Resumo:
Chronic recording of neural signals is indispensable in designing efficient brain machine interfaces and in elucidating human neurophysiology. The advent of multichannel microelectrode arrays has driven the need for electronics to record neural signals from many neurons. The dynamic range of the system is limited by background system noise which varies over time. We propose a neural amplifier in UMC 130 nm, 2P8M CMOS technology. It can be biased adaptively from 200 nA to 2 uA, modulating input referred noise from 9.92 uV to 3.9 uV. We also describe a low noise design technique which minimizes the noise contribution of the load circuitry. The amplifier can pass signal from 5 Hz to 7 kHz while rejecting input DC offsets at electrode-electrolyte interface. The bandwidth of the amplifier can be tuned by the pseudo-resistor for selectively recording low field potentials (LFP) or extra cellular action potentials (EAP). The amplifier achieves a mid-band voltage gain of 37 dB and minimizes the attenuation of the signal from neuron to the gate of the input transistor. It is used in fully differential configuration to reject noise of bias circuitry and to achieve high PSRR.
Resumo:
Surface energy processes has an essential role in urban weather, climate and hydrosphere cycles, as well in urban heat redistribution. The research was undertaken to analyze the potential of Landsat and MODIS data in retrieving biophysical parameters in estimating land surface temperature & heat fluxes diurnally in summer and winter seasons of years 2000 and 2010 and understanding its effect on anthropogenic heat disturbance over Delhi and surrounding region. Results show that during years 2000-2010, settlement and industrial area increased from 5.66 to 11.74% and 4.92 to 11.87% respectively which in turn has direct effect on land surface temperature (LST) and heat fluxes including anthropogenic heat flux. Based on the energy balance model for land surface, a method to estimate the increase in anthropogenic heat flux (Has) has been proposed. The settlement and industrial areas has higher amounts of energy consumed and has high values of Has in all seasons. The comparison of satellite derived LST with that of field measured values show that Landsat estimated values are in close agreement within error of 2 degrees C than MODIS with an error of 3 degrees C. It was observed that, during 2000 and 2010, the average change in surface temperature using Landsat over settlement & industrial areas of both seasons is 1.4 degrees C & for MODIS data is 3.7 degrees C. The seasonal average change in anthropogenic heat flux (Has) estimated using Landsat & MODIS is up by around 38 W/m(2) and 62 W/m(2) respectively while higher change is observed over settlement and concrete structures. The study reveals that the dynamic range of Has values has increased in the 10 year period due to the strong anthropogenic influence over the area. The study showed that anthropogenic heat flux is an indicator of the strength of urban heat island effect, and can be used to quantify the magnitude of the urban heat island effect. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
The influence of vibration on thermocapillary convection and critical Marangoni number in liquid bridge of half floating zone was discussed for the low frequency range 0.4-1.5 Hz and the intermediate frequency range 2.5-15 Hz in our previous papers. This paper extends the study to high frequency range 15-100Hz. This ground based experiment was completed on the deck of an electromagnetic vibration machine. The results of our experiment shows when the frequency of the applied acceleration is high enough, the amplitude of the time varying part of the temperature response is disappear and the shape of the free surface of the liquid bridge exhibits no fluctuations due to inertia. The critical Marangoni number which is defined to describe the transitions from a peroidical convection in response to vibration to an oscillatory convection due to internal instability is nearly the same as the critical Marangoni number for oscillatory flow in the absence of vibration.
Resumo:
Measuring electrical activity in large numbers of cells with high spatial and temporal resolution is a fundamental problem for the study of neural development and information processing. To address this problem, we have constructed FlaSh: a novel, genetically-encoded probe that can be used to measure trans-membrane voltage in single cells. We fused a modified green fluorescent protein (GFP) into a voltage-sensitive potassium channel so that voltage dependent rearrangements in the potassium channel induce changes in the fluorescence of GFP. A voltage sensor encoded into DNA has the advantage that it may be introduced into an organism non-invasively and targeted to specific developmental stages, brain regions, cell types, and sub-cellular compartments.
We also describe modifications to FlaSh that shift its color, kinetics, and dynamic range. We used multiple green fluorescent proteins to produce variants of the FlaSh sensor that generate ratiometric signal output via fluorescence resonance energy transfer (FRET). Finally, we describe initial work toward FlaSh variants that are sensitive to G-protein coupled receptor (GPCR) activation. These sensors can be used to design functional assays for receptor activation in living cells.
Resumo:
This thesis is concerned with spatial filtering. What is its utility in tone reproduction? Does it exist in vision, and if so, what constraints does it impose on the nervous system?
Tone reproduction is just the art and science of taking a picture and then displaying it. The sensors available to capture an image have a greater dynamic range than the media that may be used to display it. Conventionally, spatial filtering is used to boost contrast; it ameliorates the loss of contrast that results when the sensor signal range is scaled down to fit the display range. In this thesis, a type of nonlinear spatial filtering is discussed that results in direct range reduction without range scaling. This filtering process is instantiated in a real-time image processor built using analog CMOS VLSI.
Spatial filtering must be applied with care in both artificial and natural vision systems. It is argued that the nervous system does not simply filter linearly across an image. Rather, the way that we see things implies that the nervous system filters nonlinearly. Further, many models for color vision include a high-pass filtering step in which the DC information is lost. A real-time study of filtering in color space leads to the conclusion that the nervous system is not that simple, and that it maintains DC information by referencing to white.
Resumo:
The goal of this thesis is to develop a proper microelectromechanical systems (MEMS) process to manufacture piezoelectric Parylene-C (PA-C), which is famous for its chemical inertness, mechanical and thermal properties and electrical insulation. Furthermore, piezoelectric PA-C is used to build miniature, inexpensive, non-biased piezoelectric microphones.
These piezoelectric PA-C MEMS microphones are to be used in any application where a conventional piezoelectric and electret microphone can be used, such as in cell phones and hearing aids. However, they have the advantage of a simplified fabrication process compared with existing technology. In addition, as a piezoelectric polymer, PA-C has varieties of applications due to its low dielectric constant, low elastic stiffness, low density, high voltage sensitivity, high temperature stability and low acoustic and mechanical impedance. Furthermore, PA-C is an FDA approved biocompatible material and is able to maintain operate at a high temperature.
To accomplish piezoelectric PA-C, a MEMS-compatible poling technology has been developed. The PA-C film is poled by applying electrical field during heating. The piezoelectric coefficient, -3.75pC/N, is obtained without film stretching.
The millimeter-scale piezoelectric PA-C microphone is fabricated with an in-plane spiral arrangement of two electrodes. The dynamic range is from less than 30 dB to above 110 dB SPL (referenced 20 µPa) and the open-circuit sensitivities are from 0.001 – 0.11 mV/Pa over a frequency range of 1 - 10 kHz. The total harmonic distortion of the device is less than 20% at 110 dB SPL and 1 kHz.
Resumo:
High-background applications such as climate monitoring, biology and security applications demand a large dynamic range. Under such conditions ultra-high sensitivity is not required. The resonator bolometer is a novel detector which is well-suited for these conditions. This device takes advantage of the high-density frequency multiplexing capabilities of superconducting microresonators while allowing for the use of high-Tc superconductors in fabrication, which enables a modest (1-4 K) operating temperature and larger dynamic range than is possible with conventional microresonators. The moderate operating temperature and intrinsic multiplexability of this device reduce cost and allow for large pixel counts, making the resonator bolometer especially suitable for the aforementioned applications. A single pixel consists of a superconducting microresonator whose light-absorbing area is placed on a thermally isolated island. Here we present experimental results and theoretical calculations for a prototype resonator bolometer array. Intrinsic device noise and noise equivalent power (NEP) under both dark and illuminated conditions are presented. Under dark conditions the device sensitivity is limited by the thermal noise fluctuations from the bolometer legs. Under the experimental illuminated conditions the device was photon noise limited.
Resumo:
A phase and amplitude, off-axis hologram has been synthesized from three computer-generated transmission masks, using a multiple-exposure holographic recording method. Each of the masks controls one fixed-phase component of the complex hologram transmittance. The basic grating is generated optically, relieving the computer of the burden of drawing details the size of each fringe. The maximum information capacity of the computer plotting device can then be applied to the generation of the grating modulation function. By this method large digital holograms (25 mm by 25 mm) have been synthesized in dichromated gelatin. The recording method is applicable to virtually any holographic medium.
The modulated grating hologram was designed primarily for the application of spatial filtering, in which the requirement is a hologram with large dynamic range and large free spectral range. Choice of a low-noise, high-efficiency medium such as dichromated gelatin will allow exceptionally large dynamic range. Independence of the optically-generated carrier grating from the computer-generated modulation functions allows arbitrarily large free spectral range.
The performance of a holographic spatial filter will be limited ultimately by noise originating from imperfections in the holographic medium. The characteristics of this noise are analyzed, and in the case of a high diffraction efficiency hologram are shown to differ significantly from previous analyses. The dominant noise source in holograms of high diffraction efficiency will be scattering of the first order or imaging wave by deformations in the hologram surface or other effects of low spatial frequency. Experimental measurements in various low-noise holographic media verify these predictions.
Resumo:
提出了一种能够测量高温的光纤布拉格光栅(FBG)传感器结构。利用线膨胀系数和长度均不同的两种金属细杆和光纤布拉格光栅设计而成的传感头,能够将被测温度转化为光栅的应变,解调由应变引起的光栅波长漂移,即可得知待测的温度。目前在实验室实现了500℃的动态范围和1℃的温度分辨率,实验结果与理论分析一致。
Resumo:
Based on the well known sea ice phase diagram, equations are derived for determining the brine and gas content of sea Ice for high temperatures (range 0 to -2 °C) and low salinities. The presently widely used equations of Cox and Weeks (1982) are valid only for temperatures below -2°C. Fresh-water ice is used as a boundary condition for the equations. The relative salt concentrations in brine are_assumed to be the same as in normal (or standard) seawater. Two sets of equations are presented: 1) accurate formulae based on UNESCO standard sea water equations, and 2) approximate formulae based on general properties of weak solutions. The approximate formulae are not essentially different from the classical system which basically assumes the freezing point to be a linear function of fractional salt content. The agreement between the two approaches is excellent and the approximate system is good enough for most applications.
Resumo:
Ensaio não destrutivo é uma ferramenta essencial quando um equipamento, dispositivo ou componente não pode ser submetido a procedimentos destrutivos ou invasivos devido a razões de segurança, alto custo ou outras restrições físicas ou logísticas. Dentro deste quadro radiografias por transmissão com raios gama e nêutrons térmicos são técnicas singulares para inspecionar um objeto e desvendar sua estrutura interna devido à capacidade de atravessar uma vasta gama de materiais utilizados na indústria. Grosso modo, raios gama são mais atenuados por materiais pesados enquanto nêutrons térmicos são mais atenuados por materiais mais leves, tornando-as ferramentas complementares. Este trabalho apresenta os resultados obtidos na inspeção de vários componentes mecânicos, através da radiografia por transmissão com nêutrons térmicos e raios gama. O fluxo de nêutrons térmicos de 4,46x105 n.cm-2.s-1 disponível no canal principal do reator de pesquisa Argonauta do Instituto de Engenharia Nuclear foi usado como fonte para as imagens radiográficas com nêutrons. Raios dekeV emitidos pelo 198Au, também produzido no reator, foram usados como fonte de radiação para radiografias . Imaging Plates, especificamente produzidos para operar com nêutrons térmicos ou com raios X, foram empregados como detectores e dispositivos de armazenamento e captação de imagens para cada uma dessas radiações. Esses dispositivos exibem varias vantagens quando comparados ao filme radiográfico convencional. Com efeito, além de maior sensibilidade e serem reutilizáveis não são necessários câmaras escuras e processamento químico para a revelação. Em vez disso, ele é lido por um feixe de laser que libera elétrons armadilhados na rede cristalina durante a exposição à radiação, fornecendo uma imagem final digital. O desempenho de ambos os sistemas de aquisição de imagens, assim constituído, foi avaliado com respeito à sensibilidade, resolução espacial, linearidade e range dinâmico, incluído uma comparação com sistemas radiográficos com nêutrons empregando filmes e folhas de gadolínio como conversor de nêutrons em partículas carregadas. Além desta caracterização, diversos equipamentos e componentes foram radiografados com ambos os sistemas visando-se avaliar suas capacidades de desvendar a estrutura interna desses objetos e detectar estruturas e estados anormais. Dentro desta abordagem, uma neutrongrafia detectou a presença de material cerâmico remanescente empregado como molde no processo de fabricação nos canais de refrigeração de uma aleta do estator de uma turbina tipo turbo-fan, que deveria estar livre desse material. O reostato danificado de um sensor de pressão automotivo, foi identificado por neutrongrafia, embora nesse caso a radiografia também conseguiu realizar essa tarefa com melhor resolução, corroborando assim as curvas de resolução espacial obtidas na caracterização dos dois sistemas. A homogeneidade da distribuição do material encapsulado em uma gaxeta explosiva de chumbo utilizada na indústria aeroespacial foi igualmente verificada por neutrongrafia porque esse metal é relativamente transparente para nêutrons, mas suficientemente opaco para o explosivo rico em hidrogênio. Diversos outros instrumentos e componentes tais como variômetro, altímetro, bússola aeronáutica, injetor automotivo de combustível, foto-camera, disco rígido de computador, motor de passo, conectores eletrônicos e projéteis foram radiografados com ambos os sistemas visando avaliar suas habilidades em desvendar diferentes peculiaridades em função do agente interrogador.
Resumo:
An integrated EOM VCSELs is shown to offer high linearity (92dB/Hz 2/3 at 6GHz) and by extrapolation ∼90dB/Hz2/3 up to 20GHz. Successful modulation with IEEE 802.11g signals is demonstrated at 6GHz with a 12dB dynamic range. © 2011 Optical Society of America.
Resumo:
An integrated EOM VCSELs is shown to offer high linearity (92dB/Hz2/3 at 6GHz) and by extrapolation ~90dB/Hz2/3 up to 20GHz. Successful modulation with IEEE 802.11g signals is demonstrated at 6GHz with a 12dB dynamic range. © OSA/OFC/NFOEC 2011.
Resumo:
A fully-differential switched-capacitor sample-and-hold (S/H) circuit used in a 10-bit 50-MS/s pipeline analog-to-digital converter (ADC) was designed and fabricated using a 0.35-μm CMOS process. Capacitor fliparound architecture was used in the S/H circuit to lower the power consumption. In addition, a gain-boosted operational transconductance amplifier (OTA) was designed with a DC gain of 94 dB and a unit gain bandwidth of 460 MHz at a phase margin of 63 degree, which matches the S/H circuit. A novel double-side bootstrapped switch was used, improving the precision of the whole circuit. The measured results have shown that the S/H circuit reaches a spurious free dynamic range (SFDR) of 67 dB and a signal-to-noise ratio (SNR) of 62.1 dB for a 2.5 MHz input signal with 50 MS/s sampling rate. The 0.12 mm~2 S/H circuit operates from a 3.3 V supply and consumes 13.6 mW.
Resumo:
A compact direct digital frequency synthesizer (DDFS) for system-on-chip implementation of the high precision rubidium atomic frequency standard is developed. For small chip size and low power consumption, the phase to sine mapping data is compressed using sine symmetry technique, sine-phase difference technique, quad line approximation technique,and quantization and error read only memory (QE-ROM) technique. The ROM size is reduced by 98% using these techniques. A compact DDFS chip with 32bit phase storage depth and a 10bit on-chip digital to analog converter has been successfully implemented using a standard 0.35μm CMOS process. The core area of the DDFS is 1.6mm^2. It consumes 167mW at 3.3V,and its spurious free dynamic range is 61dB.