872 resultados para dynamic and static qualities
Resumo:
Patients who went through a Stroke may require mechanical ventilation (MV) in the acute phase of the disease and, on MV, they may show alterations in the respiratory mechanic. Physiotherapy techniques are applied in patients on MV to improve their respiratory mechanic. Thus, the purpose of this study was to evaluate the effects of the Respiratory Physiotherapy into the dynamic compliance (Cdyn), static compliance (Cst) and airway resistance (Rwa) in Stroke patients on MV. In order to do that, patients with Stroke diagnostic on MV were evaluated, before and after the use of Physiotherapy techniques (manual rib-cage compression, thoracic decompression, zero end expiratory pressure and suctioning). Cdyn, Cst and Rwa were the researched variables. Statistical Analysis was made using Paired T-Test with statistical significance with p-values no greater than 5%. Eleven patients were part of the study, with an average of 64,6±12,5 years old. Cdyn increased after physiotherapy from 29,3±16,1 ml/cmH2O to 33,8±16,7 ml/cmH2O (p=0,03). Cst also increased from 44,4±20,7 ml/cmH2O to 54,0±26,6 ml/cmH2O (p=0,024). No significant difference was detected for Rwa between the before and after moments (Before – 8,0±3,2 cmH2O/l/s, After – 7,3±2,25 cmH2O/l/s; p=0,45). It was possible to conclude that both dynamic and static compliance increased after physiotherapy, but the airway resistance did not increase in patients with stroke on mechanical ventilation.
Resumo:
The potential of clear Ga2S3-GeS2-CsCl based sulfide glasses transparent up to 11.5 μm to be used as new optical material for multispectral applications has been investigated. The addition of large amount of chlorine ions – above 40 mol.% of CsCl – into the chalcogenide vitreous network in order to produce colorless glasses results in a drastic increase of their water contamination. We report for the first time, to the best of our knowledge, the purification of cesium chloride CsCl by dynamic distillations under vacuum in order to reduce water and hydroxyl group contamination before complete melting of the glass. Besides, sulfur purification by dynamic and static distillations was also performed in the implemented method. The obtained glasses were then characterized by UV-visible and infrared (FTIR) spectroscopies, by electron probe microanalysis (EPMA), thermal analysis (DSC), and their refractive indices in the visible and near infrared ranges were also measured. A large improvement of the glass transmission spectrum has been achieved with an estimated reduction of about 45 times of the OH and H2O content and 60 times of the SH content. The glass thermal molding ability and chemical durability with and without protective coating have been tested to probe their potential for fabrication of complex optics.
Quantitative end qualitative analysis of the electrical activity of rectus abdominis muscle portions
Resumo:
The purpose of this study was to investigate the electrical behavior pattern of the Rectus abdominis muscle by qualitative and quantitative analysis of the electromyographic signal obtained from its superior, medium and inferior portions during dynamic and static activities. Ten voluntaries (aged X = 17.8 years, SD = 1.6) athletic males were studied without history of muscle skeletal disfunction. For the quantitative analysis the RMS (Root Mean Square) values obtained in the electromyographic signal during the isometric exercises were normalized and expressed in maximum voluntary isometric contraction percentages. For the qualitative analysis of the dynamic activity the electromyographic signal was processed by full-wave rectification, linear envelope and normalization (amplitude and time), so that the resulting curve of the processed signal was submitted to descriptive graphic analysis. The results of the quantitative study show that there is not a statistically significant difference among the portions of the muscle. Qualitative analysis demonstrated two aspects: the presence of a common activation electric pattern in the portions of Rectus abdominis muscle and the absence of significant difference in the inclination angles in the electrical activity curve during the isotonic exercises.
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC
Resumo:
The research performed during the PhD and presented in this thesis, allowed to make judgments on pushover analysis method about its application in evaluating the correct structural seismic response. In this sense, the extensive critical review of existing pushover procedures (illustrated in chapter 1) outlined their major issues related to assumptions and to hypothesis made in the application of the method. Therefore, with the purpose of evaluate the effectiveness of pushover procedures, a wide numerical investigation have been performed. In particular the attention has been focused on the structural irregularity on elevation, on the choice of the load vector and on its updating criteria. In the study eight pushover procedures have been considered, of which four are conventional type, one is multi-modal, and three are adaptive. The evaluation of their effectiveness in the identification of the correct dynamic structural response, has been done by performing several dynamic and static non-linear analysis on eight RC frames, characterized by different proprieties in terms of regularity in elevation. The comparisons of static and dynamic results have then permitted to evaluate the examined pushover procedures and to identify the expected margin of error by using each of them. Both on base shear-top displacement curves and on considered storey parameters, the best agreement with the dynamic response has been noticed on Multi-Modal Pushover procedure. Therefore the attention has been focused on Displacement-based Adative Pushover, coming to define for it an improvement strategy, and on modal combination rules, advancing an innovative method based on a quadratic combination of the modal shapes (QMC). This latter has been implemented in a conventional pushover procedure, whose results have been compared with those obtained by other multi-modal procedures. The development of research on pushover analysis is very important because the objective is to come to the definition of a simple, effective and reliable analysis method, indispensable tool in the seismic evaluation of new or existing structures.
Resumo:
Sowohl die Komplexierung von Polyelektrolyten mit anorganischen Salzen, als auch die mit entgegengesetzt geladenen Polymeren wurde von vielen Autoren bereits intensiv untersucht. Doch gerade mit Molekülen die zwischen diesen beiden Extremen liegen, sollte es möglich sein, durch elektrostatische Wechselwirkungen gezielt nanometergroße Teilchen definierter Struktur herzustellen. Ziel dieser Arbeit war es deshalb, die Strukturbildung doppelthydrophiler Blockcopolymere mit mehrwertigen organischen Gegenionen zu untersuchen und insbesondere Parameter für die Bildung supramolekularer Strukturen in wässriger Lösung zu finden. Als Blockcopolymer wurde dabei Polyethylenoxid-b-methacrylsäure mittels anionischer Polymerisation hergestellt und mittels Gelpermeationschromatographie (GPC) und Kernresonanzspektroskopie (NMR)charakterisiert. Die Strukturbildung des Polyelektrolyten mit mehrwertigen organischen Gegenionen wurde in pH = 6- und pH = 7-Pufferlösung mit dynamischer und statischer Lichtstreuung, Kleinwinkelneutronenstreuung und Ultrazentrifugation untersucht. Mit Diaminobenzidin als Gegenion wurden dabei sphärische Komplexe mit einem hydrodynamischen Radius um 100 nm erhalten und mit Ultrazentrifugation der Anteil des Gegenions im Komplex quantifiziert. Die schlechte Löslichkeit des Diaminobenzidins in wässrigem Medium erschwerte allerdings die Interpretation der Ergebnisse. Trotzdem deuten diese darauf hin, dass keine Kolloidbildung des Diaminobenzidins, sondern eine Komplexierung der Einzelmoleküle mit dem Copolymer vorliegt. Um Probleme mit der Löslichkeit zu vermeiden, wurden schliesslich Polyamidoamin-Dendrimere als Gegenionen verwendet. Dabei wurde in pH = 6- und pH = 7-Pufferlösung für Dendrimere der Generation 4 mit steigender Gegenionenkonzentration ein kontinuierlicher Anstieg des hydrodynamischen Radius bis zu einer Größe von 70 nm gefunden. Mit Kleinwinkelneutronenstreuung konnte eine ellipsoidale Struktur dieser Komplexe beobachtet werden. Auch die Größe der Gegenionen spielt für die Bildung supramolekularer Aggregate eine Rolle. So zeigte sich, dass für Polyamidoamin-Dendrimere der Generation 2, analog zu denen der Generation 4, ein Anstieg des hydrodynamischen Radius mit steigender Gegenionenkonzentration zu beobachten ist. Für Generation 0-Dendrimere hingegen wurde ein umgekehrter Verlauf beobachtet, welcher dem für Diaminobenzidin gleicht. Somit kann man annehmen, dass die Aggregation mit kleinen Molekülen zu einer anderen Struktur der Komplexe führt, als die mit größeren Molekülen.
Resumo:
Moose is a powerful reverse engineering platform, but its facilities and means to analyze software are separated from the tools developers typically use to develop and maintain their software systems: development environments such as Eclipse, VisualWorks, or Squeak. In practice, this requires developers to work with two distinct environments, one to actually develop the software, and another one (e.g., Moose) to analyze it. We worked on several different techniques, using both dynamic and static analyzes to provide software analysis capabilities to developers directly in the IDE. The immediate availability of analysis tools in an IDE significantly increases the likelihood that developers integrate software analysis in their daily work, as we discovered by conducting user studies with developers. Finally, we identified several important aspect of integrating software analysis in IDEs that need to be addressed in the future to increase the adoption of these techniques by developers.
Resumo:
The potential of integrating multiagent systems and virtual environments has not been exploited to its whole extent. This paper proposes a model based on grammars, called Minerva, to construct complex virtual environments that integrate the features of agents. A virtual world is described as a set of dynamic and static elements. The static part is represented by a sequence of primitives and transformations and the dynamic elements by a series of agents. Agent activation and communication is achieved using events, created by the so-called event generators. The grammar defines a descriptive language with a simple syntax and a semantics, defined by functions. The semantics functions allow the scene to be displayed in a graphics device, and the description of the activities of the agents, including artificial intelligence algorithms and reactions to physical phenomena. To illustrate the use of Minerva, a practical example is presented: a simple robot simulator that considers the basic features of a typical robot. The result is a functional simple simulator. Minerva is a reusable, integral, and generic system, which can be easily scaled, adapted, and improved. The description of the virtual scene is independent from its representation and the elements that it interacts with.
Resumo:
This thesis described the research carried out on the development of a novel hardwired tactile sensing system tailored for the application of a next generation of surgical robotic and clinical devices, namely a steerable endoscope with tactile feedback, and a surface plate for patient posture and balance. Two case studies are examined. The first is a one-dimensional sensor for the steerable endoscope retrieving shape and ‘touch’ information. The second is a two-dimensional surface which interprets the three-dimensional motion of a contacting moving load. This research can be used to retrieve information from a distributive tactile sensing surface of a different configuration, and can interpret dynamic and static disturbances. This novel approach to sensing has the potential to discriminate contact and palpation in minimal invasive surgery (MIS) tools, and posture and balance in patients. The hardwired technology uses an embedded system based on Field Programmable Gate Arrays (FPGA) as the platform to perform the sensory signal processing part in real time. High speed robust operation is an advantage from this system leading to versatile application involving dynamic real time interpretation as described in this research. In this research the sensory signal processing uses neural networks to derive information from input pattern from the contacting surface. Three neural network architectures namely single, multiple and cascaded were introduced in an attempt to find the optimum solution for discrimination of the contacting outputs. These architectures were modelled and implemented into the FPGA. With the recent introduction of modern digital design flows and synthesis tools that essentially take a high-level sensory processing behaviour specification for a design, fast prototyping of the neural network function can be achieved easily. This thesis outlines the challenge of the implementations and verifications of the performances.
Resumo:
Objectives and Methods: Contact angle, as a representative measure of surface wettability, is often employed to interpret contact lens surface properties. The literature is often contradictory and can lead to confusion. This literature review is part of a series regarding the analysis of hydrogel contact lenses using contact angle techniques. Here we present an overview of contact angle terminology, methodology, and analysis. Having discussed this background material, subsequent parts of the series will discuss the analysis of contact lens contact angles and evaluate differences in published laboratory results. Results: The concepts of contact angle, wettability and wetting are presented as an introduction. Contact angle hysteresis is outlined and highlights the advantages in using dynamic analytical techniques over static methods. The surface free energy of a material illustrates how contact angle analysis is capable of providing supplementary surface characterization. Although single values are able to distinguish individual material differences, surface free energy and dynamic methods provide an improved understanding of material behavior. The frequently used sessile drop, captive bubble, and Wilhelmy plate techniques are discussed. Their use as both dynamic and static methods, along with the advantages and disadvantages of each technique, is explained. Conclusions: No single contact angle technique fully characterizes the wettability of a material surface, and the application of complimenting methods allows increased characterization. At present, there is not an ISO standard method designed for soft materials. It is important that each contact angle technique has a standard protocol, as small protocol differences between laboratories often contribute to a variety of published data that are not easily comparable. © 2013 Contact Lens Association of Ophthalmologists.
Resumo:
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015.
Resumo:
Dissertação de mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2014
Resumo:
Au cours des vingt dernières années, l’anesthésie régionale est devenue, autant en médecine vétérinaire qu’humaine, un outil essentiel à l’élaboration de protocoles analgésiques péri-opératoires. Parmi l’éventail de techniques mises au point en anesthésie canine, le bloc paravertébral du plexus vertébral (PBPB) et sa version modifiée sont d’un grand intérêt pour toute procédure du membre thoracique, dans sa portion proximale. Toutefois, l’essentiel des données publiées à ce jour provient d’études colorimétriques, sans évaluation clinique, et peu d’information est disponible sur les techniques de localisation nerveuse envisageables à ce site. Notre étude visait à décrire une approche échoguidée du PBPB modifié, puis à caractériser ses paramètres pharmacocinétiques et pharmacodynamiques après administration de lidocaïne (LI) ou lidocaïne adrénalinée (LA). Huit chiens ont été inclus dans un protocole prospectif, randomisé, en aveugle et croisé, réparti sur trois périodes. L’impact pharmacodynamique du bloc effectué avec LI ou LA a été évalué régulièrement pour 180 min suivant son exécution. Le traitement à l’adrénaline n’a pas démontré d’impact significatif (P = 0,845) sur la durée du bloc sensitif, tel qu’évalué par un stimulus douloureux mécanique appliqué aux dermatomes ciblés. À l’opposé, l’atteinte proprioceptive évaluée par la démarche a été trouvée prolongée (P = 0,027) et le bloc moteur mesuré par le pic de force verticale (PVF) au trot sur la plaque de force s’est avéré plus marqué (PVF réduit; P = 0,007) sous LA. À l’arrêt comme au trot, le nadir de la courbe PVF-temps a été trouvé retardé (P < 0,005) et la pente ascendante de retour aux valeurs normales adoucie (P = 0,005). Parallèlement aux évaluations cliniques, des échantillons plasmatiques ont été collectés régulièrement afin de quantifier et décrire le devenir pharmacocinétique de la lidocaïne. Parmi les trois élaborés, un modèle bi-compartimental doté d’une double absorption asynchrone d’ordre zéro a finalement été sélectionné et appliqué aux données expérimentales. Sous LA, la Cmax a été trouvée significativement diminuée (P < 0,001), les phases d’absorption prolongées [P < 0,020 (Dur1) et P < 0,001 (Dur2)] et leurs constantes réduites [P = 0,046(k01) et P < 0,001 (k02)], le tout en concordance avec les effets proprioceptifs et moteurs rapportés. Bien que l’extrapolation du dosage soit maintenant théoriquement envisageable à partir du modèle mis en lumière ici, des études supplémentaires sont encore nécessaires afin d’établir un protocole de PBPB d’intérêt clinique. L’analyse sur plaque de force pourrait alors devenir un outil de choix pour évaluer l’efficacité du bloc dans un cadre expérimental.
Resumo:
Au cours des vingt dernières années, l’anesthésie régionale est devenue, autant en médecine vétérinaire qu’humaine, un outil essentiel à l’élaboration de protocoles analgésiques péri-opératoires. Parmi l’éventail de techniques mises au point en anesthésie canine, le bloc paravertébral du plexus vertébral (PBPB) et sa version modifiée sont d’un grand intérêt pour toute procédure du membre thoracique, dans sa portion proximale. Toutefois, l’essentiel des données publiées à ce jour provient d’études colorimétriques, sans évaluation clinique, et peu d’information est disponible sur les techniques de localisation nerveuse envisageables à ce site. Notre étude visait à décrire une approche échoguidée du PBPB modifié, puis à caractériser ses paramètres pharmacocinétiques et pharmacodynamiques après administration de lidocaïne (LI) ou lidocaïne adrénalinée (LA). Huit chiens ont été inclus dans un protocole prospectif, randomisé, en aveugle et croisé, réparti sur trois périodes. L’impact pharmacodynamique du bloc effectué avec LI ou LA a été évalué régulièrement pour 180 min suivant son exécution. Le traitement à l’adrénaline n’a pas démontré d’impact significatif (P = 0,845) sur la durée du bloc sensitif, tel qu’évalué par un stimulus douloureux mécanique appliqué aux dermatomes ciblés. À l’opposé, l’atteinte proprioceptive évaluée par la démarche a été trouvée prolongée (P = 0,027) et le bloc moteur mesuré par le pic de force verticale (PVF) au trot sur la plaque de force s’est avéré plus marqué (PVF réduit; P = 0,007) sous LA. À l’arrêt comme au trot, le nadir de la courbe PVF-temps a été trouvé retardé (P < 0,005) et la pente ascendante de retour aux valeurs normales adoucie (P = 0,005). Parallèlement aux évaluations cliniques, des échantillons plasmatiques ont été collectés régulièrement afin de quantifier et décrire le devenir pharmacocinétique de la lidocaïne. Parmi les trois élaborés, un modèle bi-compartimental doté d’une double absorption asynchrone d’ordre zéro a finalement été sélectionné et appliqué aux données expérimentales. Sous LA, la Cmax a été trouvée significativement diminuée (P < 0,001), les phases d’absorption prolongées [P < 0,020 (Dur1) et P < 0,001 (Dur2)] et leurs constantes réduites [P = 0,046(k01) et P < 0,001 (k02)], le tout en concordance avec les effets proprioceptifs et moteurs rapportés. Bien que l’extrapolation du dosage soit maintenant théoriquement envisageable à partir du modèle mis en lumière ici, des études supplémentaires sont encore nécessaires afin d’établir un protocole de PBPB d’intérêt clinique. L’analyse sur plaque de force pourrait alors devenir un outil de choix pour évaluer l’efficacité du bloc dans un cadre expérimental.
Resumo:
Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciada em Fisioterapia