959 resultados para Total analysis time


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diplomityön tarkoituksena oli selvittää miten lajinvaihtoaikoja voidaan vähentää ryhmittäin pakasteleipomossa. Työn osatavoitteina oli jakaa tuotteet ryhmiin sekä selvittää todellinen vaihtoaika kuuden kuukauden ajalta, jolloin saatiin työhön tarvittava vertailuaineisto. Työ rajattiin koskemaan vain yrityksen tehokkainta linjaa, koska siinä valmistetaan eniten tuotteita. Linjan tuotteet jaettiin ryhmiin erilaisten ominaisuuksien perusteella. Vaihtoaikojen lyhennyksessä sovellettiin eri teorioita. Tärkeimpinä teorioina voidaan mainita Shigeo Shingon kehittämä SMED-menetelmä, 5S-prosessi ja ryhmäanalyysi. SMED-menetelmän tavoitteena on jakaa asetukset sisäisiin ja ulkoisiin asetuksiin ja erottaa ne toisistaan. Tavoitteena on myös siirtää sisäisiä asetuksia ulkoisiksi. 5S-prosessi on visuaalista johtamista, jonka tavoitteena on pitää työympäristö siistinä. Ryhmäanalyysissä tuotteet jaetaan ensin ryhmiin j a sen jälkeen tuotteet laitetaan ryhmien sisällä parhaaseen mahdolliseen ajojärjestykseen. Tämän jälkeen ryhmät laitetaan keskenään parhaaseen ajojärjestykseen. Työn tavoitteena oli vähentää vaihtoaikaa viisi prosenttia tuotannon kokonaisajasta sekä tehdä kehityssuunnitelma, jonka avulla voidaan vähentää vaihtoaikoja kohdeyrityksen muilla linjoilla. Kokeilujen jälkeen kohdelinjan keskimääräinen viikoittainen vaihtoaika lyheni 1,1 % ja keskimääräisen vaihdon pituus lyheni 19 minuuttia. Tulosten perusteella kehitettiin kahdeksankohtainen kehityssuunnitelma.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this study was to evaluate if there is a significant effect of lunar phases on subjective and objective sleep variables in the general population. METHODS: A total of 2125 individuals (51.2% women, age 58.8 ± 11.2 years) participating in a population-based cohort study underwent a complete polysomnography (PSG) at home. Subjective sleep quality was evaluated by a self-rating scale. Sleep electroencephalography (EEG) spectral analysis was performed in 759 participants without significant sleep disorders. Salivary cortisol levels were assessed at awakening, 30 min after awakening, at 11 am, and at 8 pm. Lunar phases were grouped into full moon (FM), waxing/waning moon (WM), and new moon (NM). RESULTS: Overall, there was no significant difference between lunar phases with regard to subjective sleep quality. We found only a nonsignificant (p = 0.08) trend toward a better sleep quality during the NM phase. Objective sleep duration was not different between phases (FM: 398 ± 3 min, WM: 402 ± 3 min, NM: 403 ± 3 min; p = 0.31). No difference was found with regard to other PSG-derived parameters, EEG spectral analysis, or in diurnal cortisol levels. When considering only subjects with apnea/hypopnea index of <15/h and periodic leg movements index of <15/h, we found a trend toward shorter total sleep time during FM (FM: 402 ± 4, WM: 407 ± 4, NM: 415 ± 4 min; p = 0.06) and shorter-stage N2 duration (FM: 178 ± 3, WM: 182 ± 3, NM: 188 ± 3 min; p = 0.05). CONCLUSION: Our large population-based study provides no evidence of a significant effect of lunar phases on human sleep.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The amazing world of micro total analysis systems has provided a true revolution in analytical chemistry in recent years. The application of the microfluidic devices for chemical and biochemical processing has attracted considerable interest due to its advantages such as reduced sample and reagent consumption, processing time, energy, waste, cost, and portability. The aim of the present report is to disseminate the state of the art related to the miniaturization science in Analytical Chemistry. Historical progress, microfabrication technologies, required instrumentation and applications of the mTAS are presented in the current article, with special attention to the Brazilian contributions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We showed that guaraná (Paullinia cupana Mart var. sorbilis) had a chemopreventive effect on mouse hepatocarcinogenesis and reduced diethylnitrosamine-induced DNA damage. In the present experiment, we evaluated the effects of guaraná in an experimental metastasis model. Cultured B16/F10 melanoma cells (5 x 10(5) cells/animal) were injected into the tail vein of mice on the 7th day of guaraná treatment (2.0 mg P. cupana/g body weight, per gavage) and the animals were treated with guaraná daily up to 14 days until euthanasia (total treatment time: 21 days). Lung sections were obtained for morphometric analysis, apoptotic bodies were counted to calculate the apoptotic index and proliferating cell nuclear antigen-positive cells were counted to determine the proliferation index. Guaraná-treated (GUA) animals presented a 68.6% reduction in tumor burden area compared to control (CO) animals which were not treated with guaraná (CO: 0.84 ± 0.26, N = 6; GUA: 0.27 ± 0.24, N = 6; P = 0.0043), a 57.9% reduction in tumor proliferation index (CO: 23.75 ± 20.54, N = 6; GUA: 9.99 ± 3.93, N = 6; P = 0.026) and a 4.85-fold increase in apoptotic index (CO: 66.95 ± 22.95, N = 6; GUA: 324.37 ± 266.74 AB/mm², N = 6; P = 0.0152). In this mouse model, guaraná treatment decreased proliferation and increased apoptosis of tumor cells, consequently reducing the tumor burden area. We are currently investigating the molecular pathways of the effects of guaraná in cultured melanoma cells, regarding principally the cell cycle inhibitors and cyclins.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To evaluate the effect of smoking habits on sleep, data from 1492 adults referred to the Sleep Institute were accessed and divided into 3 categories of smoking status: current, former and non-smokers. Categories of pack-years (<15 and ≥15) defined smoking severity. The association of smoking status and smoking severity with sleep was analyzed for sleep parameters, especially apnea and hypopnea index (AHI) ≥5, more than 5% of total sleep time (TST) spent with oxyhemoglobin saturation (SaO2) <90%, and arousal index. The arousal index was higher among current (21 ± 17) and former smokers (20 ± 17) than non-smokers (17 ± 15; P < 0.04). Former smokers had a higher percent of TST at SaO2 <90% than non-smokers (9 ± 18 vs 6 ± 13; P < 0.04). Former smokers with pack-years ≥15 compared to <15 exhibited higher AHI (22 ± 24 vs 16 ± 21; P < 0.05) and arousal index (22 ± 19 vs 18 ± 15; P < 0.05). Current smokers with pack-years ≥15 compared to <15 exhibited higher arousal index (23 ± 18 vs 18 ± 16; P < 0.05) and percent of TST at SaO2 <90% (11 ± 17 vs 6 ± 13; P < 0.05). Smoking status and pack-years were not associated with AHI ≥5 on logistic regression analysis, but current smokers with pack-years ≥15 were 1.9 times more likely to spend more than 5% of TST at SaO2 <90% than non-smokers (95%CI = 1.21-2.97; P = 0.005). The variability of arousal index was influenced by gender, AHI and current smokers with pack-years ≥15 (all P < 0.01). Smoking habits seem to be associated with arousal and oxyhemoglobin desaturation during sleep, but not with AHI. The effect was more pronounced in current than former smokers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sleep is important for the recovery of a critically ill patient, as lack of sleep is known to influence negatively a person’s cardiovascular system, mood, orientation, and metabolic and immune function and thus, it may prolong patients’ intensive care unit (ICU) and hospital stay. Intubated and mechanically ventilated patients suffer from fragmented and light sleep. However, it is not known well how non-intubated patients sleep. The evaluation of the patients’ sleep may be compromised by their fatigue and still position with no indication if they are asleep or not. The purpose of this study was to evaluate ICU patients’ sleep evaluation methods, the quality of non-intubated patients’ sleep, and the sleep evaluations performed by ICU nurses. The aims were to develop recommendations of patients’ sleep evaluation for ICU nurses and to provide a description of the quality of non-intubated patients’ sleep. The literature review of ICU patients’ sleep evaluation methods was extended to the end of 2014. The evaluation of the quality of patients’ sleep was conducted with four data: A) the nurses’ narrative documentations of the quality of patients’ sleep (n=114), B) the nurses’ sleep evaluations (n=21) with a structured observation instrument C) the patients’ self-evaluations (n=114) with the Richards-Campbell Sleep Questionnaire, and D) polysomnographic evaluations of the quality of patients’ sleep (n=21). The correspondence of data A with data C (collected 4–8/2011), and data B with data D (collected 5–8/2009) were analysed. Content analysis was used for the nurses’ documentations and statistical analyses for all the other data. The quality of non-intubated patients’ sleep varied between individuals. In many patients, sleep was light, awakenings were frequent, and the amount of sleep was insufficient as compared to sleep in healthy people. However, some patients were able to sleep well. The patients evaluated the quality of their sleep on average neither high nor low. Sleep depth was evaluated to be the worst and the speed of falling asleep the best aspect of sleep, on a scale 0 (poor sleep) to 100 (good sleep). Nursing care was mostly performed while the patients were awake, and thus the disturbing effect was low. The instruments available for nurses to evaluate the quality of patients’ sleep were limited and measured mainly the quantity of sleep. Nurses’ structured observatory evaluations of the quality of patients’ sleep were correct for approximately two thirds of the cases, and only regarding total sleep time. Nurses’ narrative documentations of the patients’ sleep corresponded with patients’ self-evaluations in just over half of the cases. However, nurses documented several dimensions of sleep that are not included in the present sleep evaluation instruments. They could be classified according to the components of the nursing process: needs assessment, sleep assessment, intervention, and effect of intervention. Valid, more comprehensive sleep evaluation methods for nurses are needed to evaluate, document, improve and study patients’ quality of sleep.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Les personnes atteintes de schizophrénie peuvent présenter un sommeil anormal même lorsqu’elles sont stables cliniquement sous traitements pharmacologiques. Les études présentées dans cette thèse ont pour but de mesurer le sommeil afin de mieux comprendre les dysfonctions des mécanismes cérébraux pouvant être impliqués dans la physiopathologie de la schizophrénie. Les trois études présentées dans cette thèse rapportent des résultats sur le sommeil dans la schizophrénie à trois niveaux d’analyse chez trois groupes différents de patients. Le premier niveau est subjectif et décrit le sommeil à l’aide d’un questionnaire administré chez des personnes atteintes de schizophrénie cliniquement stables sous traitements pharmacologiques. Le deuxième niveau est objectif et évalue le sommeil par une méta-analyse des études polysomnographiques chez des patients atteints de schizophrénie ne recevant pas de traitement pharmacologique. Le troisième niveau est micro-structurel et utilise l’analyse spectrale de l’électroencéphalogramme (EEG) afin de caractériser le sommeil paradoxal de patients en premier épisode aigu de schizophrénie avant le début du traitement pharmacologique. La première étude montre que, lorsqu’évaluées par un questionnaire de sommeil, les personnes atteintes de schizophrénie cliniquement stables sous traitements pharmacologiques rapportent prendre plus de temps à s’endormir, se coucher plus tôt et se lever plus tard, passer plus de temps au lit et faire plus de siestes comparativement aux participants sains. Aussi, tout comme les participants sains, les personnes atteintes de schizophrénie rapportent un nombre normal d’éveils nocturnes, se disent normalement satisfaites de leur sommeil et se sentent normalement reposées au réveil. La deuxième étude révèle qu’objectivement, lorsque les études polysomnographiques effectuées chez des patients non traités sont soumises à une méta-analyse, les personnes atteintes de schizophrénie montrent une augmentation du délai d’endormissement, une diminution du temps total en sommeil, une diminution de l’efficacité du sommeil et une augmentation de la durée des éveils nocturnes comparativement aux participants sains. Les patients en arrêt aigu de traitement ont des désordres plus sévères au niveau de ces variables que les patients jamais traités. Seulement les patients jamais traités ont une diminution du pourcentage de stade 2 comparativement aux participants sains. La méta-analyse ne révèle pas de différence significative entre les groupes en ce qui concerne le sommeil lent profond et le sommeil paradoxal. La troisième étude, portant sur l’analyse spectrale de l’EEG en sommeil paradoxal, montre une diminution de l’amplitude relative de la bande de fréquence alpha dans les régions frontales, centrales et temporales et montre une augmentation de l’amplitude relative de la bande de fréquence bêta2 dans la région occipitale chez les personnes en premier épisode de schizophrénie jamais traitées comparativement aux participants sains. L’activité alpha absolue est positivement corrélée aux symptômes négatifs dans les régions frontales, centrales et temporales et négativement corrélée aux symptômes positifs dans la région occipitale. L’activité beta2 absolue ne montre pas de corrélation significative avec les symptômes positifs et négatifs de la schizophrénie. Ces résultats sont discutés suivant la possibilité que des dysfonctions au niveau des mécanismes de la vigilance seraient impliquées dans la physiopathologie de la schizophrénie.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the present work, Indigenous polymer coated Tin Free Steel cans were analyzed fortheir suitability for thermal processing and storage of fish and fish products following standard methods. The raw materials used for the development of ready to eat thermally processed fish products were found to be of fresh condition. The values for various biochemical and microbiological parameters of the raw materials were well within the limits. Based on the analysis of commercial sterility, instrumental colour, texture, WB-shear force and sensory parameters, squid masala processed to F0 value of 8 min with a total process time of 38.5 min and cook value of 92 min was chosen as the optimum for squid masala in tin free steel cans while shrimp curry processed to F0 7 min with total process time of 44.0 min and cook value of 91.1 min was found to be ideal and was selected for storage study. Squid masala and shrimp curry thermally processed in indigenous polymer coated TFS cans were found to be acceptable even after one year of storage at room temperaturebased on the analysis of various sensory and biochemical parameters. Analysis of the Commission Internationale d’ Eclirage L*, a* and b* color values showed that the duration of exposure to heat treatment influenced the color parameters: the lightness (L*) and yellowness (b*)decreased, and the redness (a*) significantly increased with the increase in processing time or reduction in processing temperature.Instrumental analysis of texture showed that hardness-1 & 2 decreased with reduction in retort temperature while cohesiveness value did not show any appreciable change with decrease in temperature of processing. Other texture profile parameters like gumminess, springiness and chewiness decreased significantly with increase of processing time. W-B shear force values of mackerel meat processed at 130 °C were significantly higher than those processed at 121.1 and 115 °C. HTST processing of mackerel in brine helped in reducing the process time and improving the quality.The study also indicated that indigenous polymer coated TFS cans with easy openends can be a viable alternative to the conventional tin and aluminium cans. The industry can utilize these cans for processing ready to eat fish and shell fish products for both domestic and export markets. This will help in reviving the canning industry in India.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Die Miniaturisierung von konventioneller Labor- und Analysetechnik nimmt eine zentrale Rolle im Bereich der allgemeinen Lebenswissenschaften und medizinischen Diagnostik ein. Neuartige und preiswerte Technologieplattformen wie Lab-on-a-Chip (LOC) oder Mikrototalanalysesysteme (µTAS) versprechen insbesondere im Bereich der Individualmedizin einen hohen gesellschaftlichen Nutzen zur frühzeitigen und nichtinvasiven Diagnose krankheitsspezifischer Indikatoren. Durch den patientennahen Einsatz preiswerter und verlässlicher Mikrochips auf Basis hoher Qualitätsstandards entfallen kostspielige und zeitintensive Zentrallaboranalysen, was gleichzeitig Chancen für den globalen Einsatz - speziell in Schwellen- und Entwicklungsländern - bietet. Die technischen Herausforderungen bei der Realisierung moderner LOC-Systeme sind in der kontrollierten und verlässlichen Handhabung kleinster Flüssigkeitsmengen sowie deren diagnostischem Nachweis begründet. In diesem Kontext wird der erfolgreichen Integration eines fernsteuerbaren Transports von biokompatiblen, magnetischen Mikro- und Nanopartikeln eine Schlüsselrolle zugesprochen. Die Ursache hierfür liegt in der vielfältigen Einsetzbarkeit, die durch die einzigartigen Materialeigenschaften begründet sind. Diese reichen von der beschleunigten, aktiven Durchmischung mikrofluidischer Substanzvolumina über die Steigerung der molekularen Interaktionsrate in Biosensoren bis hin zur Isolation und Aufreinigung von krankheitsspezifischen Indikatoren. In der Literatur beschriebene Ansätze basieren auf der dynamischen Transformation eines makroskopischen, zeitabhängigen externen Magnetfelds in eine mikroskopisch veränderliche potentielle Energielandschaft oberhalb magnetisch strukturierter Substrate, woraus eine gerichtete und fernsteuerbare Partikelbewegung resultiert. Zentrale Kriterien, wie die theoretische Modellierung und experimentelle Charakterisierung der magnetischen Feldlandschaft in räumlicher Nähe zur Oberfläche der strukturierten Substrate sowie die theoretische Beschreibung der Durchmischungseffekte, wurden jedoch bislang nicht näher beleuchtet, obwohl diese essentiell für ein detailliertes Verständnis der zu Grunde liegenden Mechanismen und folglich für einen Markteintritt zukünftiger Geräte sind. Im Rahmen der vorgestellten Arbeit wurde daher ein neuartiger Ansatz zur erfolgreichen Integration eines Konzepts zum fernsteuerbaren Transport magnetischer Partikel zur Anwendung in modernen LOC-Systemen unter Verwendung von magnetisch strukturierten Exchange-Bias (EB) Dünnschichtsystemen verfolgt. Die Ergebnisse zeigen, dass sich das Verfahren der ionenbe-schussinduzierten magnetischen Strukturierung (IBMP) von EB-Systemen zur Herstellung von maßgeschneiderten magnetischen Feldlandschaften (MFL) oberhalb der Substratoberfläche, deren Stärke und räumlicher Verlauf auf Nano- und Mikrometerlängenskalen gezielt über die Veränderung der Materialparameter des EB-Systems via IBMP eingestellt werden kann, eignet. Im Zuge dessen wurden erstmals moderne, experimentelle Verfahrenstechniken (Raster-Hall-Sonden-Mikroskopie und rastermagnetoresistive Mikroskopie) in Kombination mit einem eigens entwickelten theoretischen Modell eingesetzt, um eine Abbildung der MFL in unterschiedlichen Abstandsbereichen zur Substratoberfläche zu realisieren. Basierend auf der quantitativen Kenntnis der MFL wurde ein neuartiges Konzept zum fernsteuerbaren Transport magnetischer Partikel entwickelt, bei dem Partikelgeschwindigkeiten im Bereich von 100 µm/s unter Verwendung von externen Magnetfeldstärken im Bereich weniger Millitesla erzielt werden können, ohne den magnetischen Zustand des Substrats zu modifizieren. Wie aus den Untersuchungen hervorgeht, können zudem die Stärke des externen Magnetfelds, die Stärke und der Gradient der MFL, das magnetfeldinduzierte magnetische Moment der Partikel sowie die Größe und der künstlich veränderliche Abstand der Partikel zur Substratoberfläche als zentrale Einflussgrößen zur quantitativen Modifikation der Partikelgeschwindigkeit genutzt werden. Abschließend wurde erfolgreich ein numerisches Simulationsmodell entwickelt, das die quantitative Studie der aktiven Durchmischung auf Basis des vorgestellten Partikeltransportkonzepts von theoretischer Seite ermöglicht, um so gezielt die geometrischen Gegebenheiten der mikrofluidischen Kanalstrukturen auf einem LOC-System für spezifische Anwendungen anzupassen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La optimización y armonización son factores clave para tener un buen desempeño en la industria química. BASF ha desarrollado un proyecto llamada acelerador. El objetivo de este proyecto ha sido la armonización y la integración de los procesos de la cadena de suministro a nivel mundial. El proceso básico de manejo de inventarios se quedó fuera del proyecto y debía ser analizado. El departamento de manejo de inventarios en BASF SE ha estado desarrollando su propia estrategia para la definición de procesos globales de manufactura. En este trabajo se presentará un informe de las fases de la formulación de la estrategia y establecer algunas pautas para la fase de implementación que está teniendo lugar en 2012 y 2013.