950 resultados para Test results


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Enterobacteriaceae bacteria harboring Klebsiella pneumoniae carbapenemase are a serious worldwide threat. The molecular identification of these pathogens is not routine in Brazilian hospitals, and a rapid phenotypic screening test is desirable. This study aims to evaluate the modified Hodge test as a phenotypic screening test for Klebsiella pneumoniae carbapenemase. METHOD: From April 2009 to July 2011, all Enterobacteriaceae bacteria that were not susceptible to ertapenem according to Vitek2 analysis were analyzed with the modified Hodge test. All positive isolates and a random subset of negative isolates were also assayed for the presence of blaKPC. Isolates that were positive in modified Hodge tests were sub-classified as true-positives (E. coli touched the ertapenem disk) or inconclusive (distortion of the inhibition zone of E. coli, but growth did not reach the ertapenem disk). Negative results were defined as samples with no distortion of the inhibition zone around the ertapenem disk. RESULTS: Among the 1521 isolates of Enterobacteriaceae bacteria that were not susceptible to ertapenem, 30% were positive for blaKPC, and 35% were positive according to the modified Hodge test (81% specificity). Under the proposed sub-classification, true positives showed a 98% agreement with the blaKPC results. The negative predictive value of the modified Hodge test for detection was 100%. KPC producers showed high antimicrobial resistance rates, but 90% and 77% of these isolates were susceptible to aminoglycoside and tigecycline, respectively. CONCLUSION: Standardizing the modified Hodge test interpretation may improve the specificity of KPC detection. In this study, negative test results ruled out 100% of the isolates harboring Klebsiella pneumoniae carbapenemase-2. The test may therefore be regarded as a good epidemiological tool.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Enterobacteriaceae bacteria harboring Klebsiella pneumoniae carbapenemase are a serious worldwide threat. The molecular identification of these pathogens is not routine in Brazilian hospitals, and a rapid phenotypic screening test is desirable. This study aims to evaluate the modified Hodge test as a phenotypic screening test for Klebsiella pneumoniae carbapenemase. METHOD: From April 2009 to July 2011, all Enterobacteriaceae bacteria that were not susceptible to ertapenem according to Vitek2 analysis were analyzed with the modified Hodge test. All positive isolates and a random subset of negative isolates were also assayed for the presence of blaKPC. Isolates that were positive in modified Hodge tests were sub-classified as true-positives (E. coli touched the ertapenem disk) or inconclusive (distortion of the inhibition zone of E. coli, but growth did not reach the ertapenem disk). Negative results were defined as samples with no distortion of the inhibition zone around the ertapenem disk. RESULTS: Among the 1521 isolates of Enterobacteriaceae bacteria that were not susceptible to ertapenem, 30% were positive for blaKPC, and 35% were positive according to the modified Hodge test (81% specificity). Under the proposed sub-classification, true positives showed a 98% agreement with the blaKPC results. The negative predictive value of the modified Hodge test for detection was 100%. KPC producers showed high antimicrobial resistance rates, but 90% and 77% of these isolates were susceptible to aminoglycoside and tigecycline, respectively. CONCLUSION: Standardizing the modified Hodge test interpretation may improve the specificity of KPC detection. In this study, negative test results ruled out 100% of the isolates harboring Klebsiella pneumoniae carbapenemase 2. The test may therefore be regarded as a good epidemiological tool.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Interferon-gamma release assays (IGRA) are more specific than the tuberculin skin test (TST) for the diagnosis of Mycobacterium tuberculosis infection. Data on sensitivity are controversial in HIV infection. Methods IGRA (T-SPOT.TB) was performed using lymphocytes stored within 6 months before culture-confirmed tuberculosis was diagnosed in HIV-infected individuals in the Swiss HIV Cohort Study. Results 64 individuals (69% males, 45% of non-white ethnicity, median age 35 years (interquartile range [IQR] 31-42), 28% with prior AIDS) were analysed. Median CD4 cell count was 223 cells/μl (IQR 103-339), HIV-RNA was 4.7 log10 copies/mL (IQR 4.3-5.2). T-SPOT.TB resulted positive in 25 patients (39%), negative in 18 (28%) and indeterminate in 21 (33%), corresponding to a sensitivity of 39% (95% CI 27-51%) if all test results were considered, and 58% (95% CI 43-74%) if indeterminate results were excluded. Sensitivity of IGRA was independent of CD4 cell count (p = 0.698). Among 44 individuals with available TST, 22 (50%) had a positive TST. Agreement between TST and IGRA was 57% (kappa = 0.14, p = 0.177), and in 34% (10/29) both tests were positive. Combining TST and IGRA (at least one test positive) resulted in an improved sensitivity of 67% (95% CI 52-81%). In multivariate analysis, older age was associated with negative results of TST and T-SPOT.TB (OR 3.07, 95% CI 1,22-7.74, p = 0.017, per 10 years older). Conclusions T-SPOT.TB and TST have similar sensitivity to detect latent TB in HIV-infected individuals. Combining TST and IGRA may help clinicians to better select HIV-infected individuals with latent tuberculosis who qualify for preventive treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Fever is one of the most commonly seen symptoms in the pediatric emergency department. The objective of this study was to observe how the rapid testing for influenza virus impacts on the management of children with fever. METHODS: We performed a review of our pediatric emergency department records during the 2008/2009 annual influenza season. The BinaxNow Influenza A+B test was performed on patients with the following criteria: age 1.0 to 16.0 years, fever greater than 38.5 °C, fever of less than 96 hours' duration after the onset of clinical illness, clinical signs compatible with acute influenza, and nontoxic appearance. Additional laboratory tests were performed at the treating physician's discretion. RESULTS: The influenza rapid antigen test was performed in 192 children. One hundred nine (57%) were influenza positive, with the largest fraction (101 patients) positive for influenza A. The age distribution did not differ between children with negative and positive test results (mean, 5.3 vs. 5.1 years, not statistically significant). A larger number of diagnostic tests were performed in the group of influenza-negative patients. Twice as many complete blood counts, C-reactive protein determinations, lumbar punctures, and urinalyses were ordered in the latter group. CONCLUSIONS: Rapid diagnosis of influenza in the pediatric emergency department affects the management of febrile children as the confirmation of influenza virus infection decreases additional diagnostic tests ordered.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Insect bite hypersensitivity (IBH) is an IgE-mediated allergic dermatitis caused by bites of Culicoides and Simulium species, and improved means of diagnosis are required. OBJECTIVES: The cellular antigen simulation test (CAST) with C. nubeculosus and S. vittatum extracts was assessed in a population of IBH-affected and healthy horses. Variations in test results over a one year period and possible cross-reactivity between different insect extracts was studied. METHODS: A total of 314 mature horses were studied using the CAST. Influence of severity of clinical signs, gender and age were evaluated, and 32 horses were tested repeatedly over one year. The kappa reliability test was used to assess agreement of the test results with different insect extracts. RESULTS: Horses with IBH had significantly higher sLT release than controls with C. nubeculosus and S. vittatum. The highest diagnostic sensitivity and specificity levels were attained when using adult C. nubeculosus extracts with the CAST (78% and 97%, respectively), suggesting that most horses with IBH are sensitised against Culicoides allergens. A proportion of IBH-affected horses was found to be sensitised to allergens of Simulium spp. in addition to those of C. nubeculosus. The CAST with C. nubeculosus had positive and negative predictive values > or = 80% for a true prevalence of IBH of 12-52%. In the follow-up study, the proportion of IBH-affected horses with a positive test result ranged from 90% in November to 68% in March. Severity of clinical signs or age did not influence test results significantly. However, IBH-affected males achieved significantly more positive test results than IBH-affected females. CONCLUSIONS: The CAST with adult C. nubeculosus has high specificity and good sensitivity for diagnosis of IBH. Horses with IBH are mainly sensitised to Culicoides allergens, and some horses are additionally also sensitised to allergens in Simulium spp. POTENTIAL RELEVANCE: The CAST is likely to be a useful test for diagnosis of IBH, even allowing the identification of IBH-affected but asymptomatic horses. This test may also help in further characterisation of allergens involved in this condition.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Continual surveillance based on patch test results has proved useful for the identification of contact allergy. OBJECTIVES: To provide a current view on the spectrum of contact allergy to important sensitizers across Europe. PATIENTS/METHODS: Clinical and patch test data of 19 793 patients patch tested in 2005/2006 in the 31 participating departments from 10 European countries (the European Surveillance System on Contact Allergies' (ESSCA) www.essca-dc.org) were descriptively analysed, aggregated to four European regions. RESULTS: Nickel sulfate remains the most common allergen with standardized prevalences ranging from 19.7% (central Europe) to 24.4% (southern Europe). While a number of allergens shows limited variation across the four regions, such as Myroxylon pereirae (5.3-6.8%), cobalt chloride (6.2-8.8%) or thiuram mix (1.7-2.4%), the differences observed with other allergens may hint on underlying differences in exposures, for example: dichromate 2.4% in the UK (west) versus 4.5-5.9% in the remaining EU regions, methylchloroisothiazolinone/methylisothiazolinone 4.1% in the South versus 2.1-2.7% in the remaining regions. CONCLUSIONS: Notwithstanding residual methodological variation (affecting at least some 'difficult' allergens) tackled by ongoing efforts for standardization, a comparative analysis as presented provides (i) a broad overview on contact allergy frequencies and (ii) interesting starting points for further, in-depth investigation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making. OBJECTIVES: To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes). PATIENTS/METHODS: The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test. RESULTS: Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P < 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P < 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients. CONCLUSION: Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In market research, the adoption of interactive virtual reality-techniques could be expected to contain many advantages: artificial lab environments could be designed in a more realistic manner and the consideration of “time to the market”-factors could be improved. On the other hand, with an increasing degree of presence and the notional attendance in a simulated test environment, the market research task could fall prey to the tensing virtual reality adventure. In the following study a 3D-technique is empirically tested for its usability in market research. It will be shown that the interactive 3D-simulation is not biased by the immersion it generates and provides considerably better test results than 2D-stimuli do.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cryptococcus spp. commonly causes infection in immunocompromised hosts. Clinical presentation of cryptococcal meningoencephalitis (CM) is variable, but headache, fever and a high intracranial pressure should suggest the diagnosis. The cryptococcal antigen test is a specific and sensitive rapid test that can be performed on blood or cerebrospinal fluid. We report a case of CM in a patient with previously undetected lymphocytopenia. Because cryptococcal antigen test results were negative, diagnosis and treatment were delayed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. METHODS This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. RESULTS In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11 %) were demented. If SST or PMR were abnormal, sensitivity was 71 % (95 % CI 44-90 %), and specificity 64 % (95 % CI 55-72 %) for detecting dementia. If both tests were abnormal, sensitivity was 24 % (95 % CI 7-50 %), but specificity increased to 93 % (95 % CI 88-97 %). CONCLUSION Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose. To evaluate the use of the Legionella Urine Antigen Test as a cost effective method for diagnosing Legionnaires’ disease in five San Antonio Hospitals from January 2007 to December 2009. ^ Methods. The data reported by five San Antonio hospitals to the San Antonio Metropolitan Health District during a 3-year retrospective study (January 2007 to December 2009) were evaluated for the frequency of non-specific pneumonia infections, the number of Legionella Urine Antigen Tests performed, and the percentage of positive cases of Legionnaires’ disease diagnosed by the Legionella Urine Antigen Test.^ Results. There were a total of 7,087 cases of non-specific pneumonias reported across the five San Antonio hospitals studied from 2007 to 2009. A total of 5,371 Legionella Urine Antigen Tests were performed from January, 2007 to December, 2009 across the five San Antonio hospitals in the study. A total of 38 positive cases of Legionnaires’ disease were identified by the use of Legionella Urinary Antigen Test from 2007-2009.^ Conclusions. In spite of the limitations of this study in obtaining sufficient relevant data to evaluate the cost effectiveness of Legionella Urinary Antigen Test in diagnosing Legionnaires’ disease, the Legionella Urinary Antigen Test is simple, accurate, faster, as results can be obtained within minutes to hours; and convenient because it can be performed in emergency room department to any patient who presents with the clinical signs or symptoms of pneumonia. Over the long run, it remains to be shown if this test may decrease mortality, lower total medical costs by decreasing the number of broad-spectrum antibiotics prescribed, shorten patient wait time/hospital stay, and decrease the need for unnecessary ancillary testing, and improve overall patient outcomes.^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The use of modular or ‘micro’ maximum power point tracking (MPPT) converters at module level in series association, commercially known as “power optimizers”, allows the individual adaptation of each panel to the load, solving part of the problems related to partial shadows and different tilt and/or orientation angles of the photovoltaic (PV) modules. This is particularly relevant in building integrated PV systems. This paper presents useful behavioural analytical studies of cascade MPPT converters and evaluation test results of a prototype developed under a Spanish national research project. On the one hand, this work focuses on the development of new useful expressions which can be used to identify the behaviour of individual MPPT converters applied to each module and connected in series, in a typical grid-connected PV system. On the other hand, a novel characterization method of MPPT converters is developed, and experimental results of the prototype are obtained: when individual partial shading is applied, and they are connected in a typical grid connected PV array

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Consolidation tests were performed on 19 samples of calcareous ooze from the Ontong Java Plateau, obtained during Ocean Drilling Program Leg 130. Rebound curves from consolidation tests on Ontong Java Plateau samples yield porosity rebounds of 1%-4% for these sediments at equivalent depths up to 1200 mbsf. The exception is a radiolarian-rich sample that has 6% rebound. A rebound correction derived from the porosity rebound vs. depth data has been combined with a correction for pore-water expansion to correct the shipboard laboratory porosity data to in-situ values. Comparison of the laboratory porosity data corrected in this manner with the downhole log data shows good agreement.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Statistics on employees returned to duty and results of return-to-duty tests and follow-up tests are presented separately from results of the other four test types because return-to-duty tests and follow-up tests represent a different segment of the test population and not all employers offer rehabilitation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aims: The objective of this study was to evaluate the accuracy, ease of use and reproducibility of chromogenic in situ hybridisation (CISH) for HER2 testing by studying its inter-laboratory concordance in five Australian pathology laboratories. Methods: The HER2 status of 49 breast cancers was determined by CISH twice in two different laboratories. Each sample had previously been tested by immunohistochemistry (IHC; 2+ and 3+ cases selected) and fluorescence in situ hybridisation ( FISH). Participating laboratories were blinded to these test results. Oestrogen receptor ( ER) status was also evaluated for each cancer. Results: High correlation was observed between FISH and CISH results. No cases showing high gene amplification by FISH were scored as non-amplified by CISH ( kappa coefficient=1). High correlation was observed between IHC and CISH, all IHC 3+ samples showing amplification by CISH. Inter-laboratory CISH concordance was also good ( kappa coefficient=0.67). Fifty-six per cent of HER2-amplified samples tested ER positive, while 42% of ER-positive cases showed HER2 gene amplification, confirming that HER2 testing should not be confined to ER-negative breast cancers. Conclusions: These findings demonstrate that CISH is a robust test to assess HER2 status in breast cancer and therefore is an important addition to the HER2 testing algorithm.