969 resultados para TRACE validointi


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behavior of the nuclear power plants must be known in all operational situations. Thermal hydraulics computer applications are used to simulate the behavior of the plants. The computer applications must be validated before they can be used reliably. The simulation results are compared against the experimental results. In this thesis a model of the PWR PACTEL steam generator was prepared with the TRAC/RELAP Advanced Computational Engine computer application. The simulation results can be compared against the results of the Advanced Process Simulator analysis software in future. Development of the model of the PWR PACTEL vertical steam generator is introduced in this thesis. Loss of feedwater transient simulation examples were carried out with the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of organo nanoclay 5-(4-dimethylamino-benzylidene) rhodanine-immobilized as a new, easily prepared, and stable solid sorbent for preconcentration trace amounts of Au(III) ions in aqueous solution is presented. The sorption of Au(III) ions was quantitative in the pH range of 2-4, and quantitative desorption occurred instantaneously with 10.0 mL of a mixture containing 0.5 mol L-1 Na2S2O3 and KSCN. Various parameters, such as the effect of pH, breakthrough volume, extraction time, and interference of a large number of anions and cations have been studied. The proposed method has been applied for determination of trace amount of gold in water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene. The volume and the type of extractive and dispersive solvents, the extraction time and the pH of the aqueous solutions were optimized. The calibration curve was linear in the range of 0.6-500 ng mL-1 of rhodium. The limit of detection was 0.10 ng mL-1 in initial solution and preconcentration factor was 40. The proposed method was successfully applied to the extraction and determination of rhodium in road dust and water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new cloud point extraction (CPE) method was developed for the separation and preconcentration of copper (II) prior to spectrophotometric analysis. For this purpose, 1-(2,4-dimethylphenyl) azonapthalen-2-ol (Sudan II) was used as a chelating agent and the solution pH was adjusted to 10.0 with borate buffer. Polyethylene glycol tert-octylphenyl ether (Triton X-114) was used as an extracting agent in the presence of sodium dodecylsulphate (SDS). After phase separation, based on the cloud point of the mixture, the surfactant-rich phase was diluted with acetone, and the enriched analyte was spectrophotometrically determined at 537 nm. The variables affecting CPE efficiency were optimized. The calibration curve was linear within the range 0.285-20 µg L-1 with a detection limit of 0.085 µg L-1. The method was successfully applied to the quantification of copper in different beverage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a procedure is developed for cloud point extraction of Pd(II) and Rh(III) ions in aqueous solution using Span 80 (non-ionic surfactant) prior to their determination by flame atomic absorption spectroscopy. This method is based on the extraction of Pd(II) and Rh(III) ions at a pH of 10 using Span 80 with no chelating agent. We investigated the effect of various parameters on the recovery of the analyte ions, including pH, equilibration temperature and time, concentration of Span 80, and ionic strength. Under the best experimental conditions, the limits of detection based on 3Sb for Pd(II) and Rh(III) ions were 1.3 and 1.2 ng mL-1, respectively. Seven replicate determinations of a mixture of 0.5 µg mL-1 palladium and rhodium ions gave a mean absorbance of 0.058 and 0.053 with relative standard deviations of 1.8 and 1.6%, respectively. The developed method was successfully applied to the extraction and determination of the palladium and rhodium ions in road dust and standard samples and satisfactory results were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple preconcentration method of silicon based on coprecipitation with aluminum hydroxide prior to its flame atomic absorption (FAAS) determination was established. The recovery values of analyte ion was higher than 95%. The parameters including types of hydroxide ion source for precipitation, acid type for dissolution step, amount of aluminum ion as collector, pH, temperature, standing and centrifuge time, and sample volume were optimized for the quantitative recovery of the analyte. The influences of matrix ions were also examined. The relative standard deviation was found to be 3.2%. The limit of detection was calculated as (0.1 mg L-1). The preconcentration factor is 100 for (200 mL) solution. The proposed method was successfully applied for the determination of silicon in some water and alloy samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä kehitettiin mittaus- ja analyysimenetelmät suojavaatemateriaalien kemikaaliläpäisevyyden testaamiseksi sekä neste- että kaasumaisella metyylisalisylaatilla. Kehitystyö tehtiin standardin SFS-EN ISO 6529 pohjalta. Tämä standardi kuvaa kuitenkin varsin yleisellä tasolla suojavaatemateriaalien kemikaaliläpäisevyyden testimenetelmät, eikä se ole mikään tarkka työohje. Näytteenotto- ja analyysimenetelmät joudutaan siis valitsemaan sekä validoimaan jokaiselle kemikaalille erikseen, tässä tapauksessa metyylisalisylaatille. Työn tarkoituksena oli kehittää toimivat menetelmät ja laitteistot siten, että olisi mahdollista suorittaa metyylisalisylaatin määritys on-line mittauksena läpäisytestauksessa. Läpäisytestaustoiminnan nopeuttamiseksi työssä myös suunniteltiin ja rakennettiin laitteistot kolmen rinnakkaisen testikennon yhdenaikaista testausta varten sekä kaasumaisen että nestemäisen metyylisalisylaatin ollessa testikemikaalina. Havaittiin, että UV/VIS-spektrofotometri varustettuna läpivirtauskyvetillä ja näyteenottopumpulla on toimiva ja käyttökelpoinen analyysimenetelmä metyylisalisylaatin määrittämiseen nesteistä on-line mittauksena läpäisyn testauksessa. Kaasumaisen metyylisalisylaatin tapauksessa määritysmenetelmänä päädyttiin käyttämään kokonaishiilivetyanalysaattoria, joka on varustettu liekki-ionisaatiodetektorilla. Molemmissa tapauksissa saatiin aikaan toimivat ja on-line mittauksiin kykenevät näytteenotto- ja määritysmenetelmät, joilla loppukäyttäjä voi suorittaa laajempaa läpäisytestausta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parametric cost modeling is a technique, where cost estimating relationships are built to meet products’ parameters. Parameters are directly defined from product features, when it is possible to solve product cost exact before even a single product is manufactured and calculated with general cost accounting. The parametric model can be used in product design, sourcing and comparing product cost of similar products. The model reveals the cost origin more clear than general accounting. The purpose of this thesis was to find out parameters for modeling elevator doors and validate the parameters to meet actual costs. The other target was to simulate cost impact and changes in the cost structure. The results were compared to previous calculations and actual costs and model was tested in new product design. The results of the calculations revealed, that material consumption is the most significant issue in design effectiveness as well as the complexity of the components and structure. To develop the model more research is needed for other continents cost structure and waste calculation principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena on kehittää menetelmä, jolla voidaan seurata inhalaatiovalmisteen sisältämiä epäpuhtauksia. Menetelmä kehitetään erittäin korkean suorituskyvyn kromatografialaitteistolle (Ultra High Performance Liquid Chromatography, UHPLC) jo olemassa olevan HPLC-epäpuhtausmenetelmän pohjalta. Uusi menetelmä kehitetään analyysiajan lyhentämiseksi ja erotuksen resoluution parantamiseksi. Työn kirjallisuusosa esittelee lyhyesti inhalaatiovalmisteet sekä nestekromatografian perusteet. Korkean erotuskyvyn nestekromatografia ja analysoinnin apuna käytettävät parametrit selvitetään laskukaavoineen. Kirjallisuusosa keskittyy epäpuhtausmenetelmän kehittämisen kulkuun ja menetelmän validoinnissa suoritettaviin kokeisiin. Soveltavassa osassa Orion Oyj:n kehitteillä olevalle kahden vaikuttavan aineen inhalaatiovalmisteelle kehitetään UHPLC-epäpuhtausmenetelmä kirjallisuusosiossa esitellyn menetelmäkehitysrungon pohjalta. Menetelmäkehityksen kulku ja analyysin olosuhteiden valinta esitellään pääpiirteittäin, jonka jälkeen kehitetty menetelmä validoidaan sille tehdyn validointisuunnitelman mukaisesti. Kehitetystä UHPLC-epäpuhtausmenetelmästä saatiin 16 minuuttia lyhyempi kuin vastaava HPLC-epäpuhtausmenetelmä. Myös analyysin resoluutio parantui merkittävästi. Toistuvien injektioiden jälkeen kromatogrammissa esiintyi kuitenkin häntimistä, joka johti merkittävään resoluution heikkenemiseen. Häntimisen syyksi epäiltiin toisen vaikuttavan aineen kiinnittymistä kolonnimateriaaliin, mutta sen estämiseksi ehdotetut toimenpiteet eivät sopineet kehitettyyn menetelmään.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A small break loss-of-coolant accident (SBLOCA) is one of problems investigated in an NPP operation. Such accident can be analyzed using an experiment facility and TRACE thermal-hydraulic system code. A series of SBLOCA experiments was carried out on Parallel Channel Test Loop (PACTEL) facility, exploited together with Technical Research Centre of Finland VTT Energy and Lappeenranta University of Technology (LUT), in order to investigate two-phase phenomena related to a VVER-type reactor. The experiments and a TRACE model of the PACTEL facility are described in the paper. In addition, there is the TRACE code description with main field equations. At the work, calculations of a SBLOCA series are implemented and after the calculations, the thesis discusses the validation of TRACE and concludes with an assessment of the usefulness and accuracy of the code in calculating small breaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract In Turkey and several Middle East countries' people consume “leblebi” which is a traditional snack food made from chickpeas (Cicer arietinum L.). Chickpea products are highly nutritive and a cheap food for human consumption and have become an essential part of daily diets in the world. The present study aims to determine the chemical, nutritional and dietary composition of fifty leblebi samples marketed in Turkey. Protein values of the leblebi ranged from 19.4 to 23.9% dehulled and 20.3 to 20.8% for nondehulled leblebi while a value of 19.1% was recorded for chickpeas. Mineral results showed that Potassium (K) was the most abundant element in leblebi ranging from 6514 to 14431 mg/kg. The amount of dietary components neutral detergent fibre (NDF), acid detergent fibre (ADF), acid detergent lignin (ADL) and cellulose did not vary much between the samples analyzed.