311 resultados para Scintillation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

S100 beta is a soluble protein released by glial cells mainly under the activation of the 5-HT1A receptor. It has been reported as a neuro-trophic and -tropic factor that promotes neurite maturation and outgrowth during development. This protein also plays a role in axonal stability and the plasticity underlying long-term potentiation in adult brains. The ability of S100 beta to rapidly regulate neuronal morphology raises the interesting point of whether there are daily rhythm or gender differences in S100 beta level in the brain. To answer this question, the S100 beta expression in adult female and male rats, as well as in adult female CD-21 and S100 beta -/- female mice, were investigated. Scintillation counting and morphometric analysis of the immunoreactivity of S100 beta, showed rhythmic daily expression. The female and male rats showed opposite cycles. Females presented the highest value at the beginning of the rest phase (5:00 h), while in males the maximum value appeared in the beginning of the motor activity period (21:00 h). These results confirm previous S100 beta evaluations in human serum and cerebrospinal fluid reporting the protein`s function as a biomarker for brain damage (Gazzolo et al. in Clin Chem 49:967-970, 2003; Clin Chim Acta 330:131-133, 2003; Pediatr Res 58:1170-1174, 2005), similar behavior was also observed for GFAP in relation to Alzheimer Disease (Fukuyama et al. in Eur Neurol 46:35-38, 2001). The data should be taken into account when considering S100 beta as a biomarker of health condition. In addition, the results raise questions on which structure or condition imposes these rhythms as well as on the physiological meaning of the observed gender differences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Satellites signals present disturbances (scintillations), due to presence of irregularities in the ionospheric plasma. In the present work, we dedicate to the study of the attenuation of these scintillations that is, an improvement in the signal, during the main magnetic storm phase during the period of October 2006 to February 2007. Using amplitude of scintillation 1.5GHz (L1) data of the net of satellites GPS, in the ionospheric station of Natal (5.84o S, 35.20o O, -20o dip) and geomagnetic indices, during the minimum solar cycle (referred to as cycle 23), demonstrating its anti-correlation between magnetic activity (Kp) and index of scintillation () (Bonelli2005 method, that works for solar maximum, Bonelli(2005)). These results show that these storms correspond to category I of Aarons (1991). The magnetic storms can generate irregularities when the electric feld of penetration eastward on the pre-reversal hour intensificating that and can too generate irregularities on midnight and sunlight period. The limitation of the method applied here is that it is not considering some storms that had also occurred during equinox and summer in the Brazilian region. For this reason, we will use additional data of the stations of São João de Cariri (Imager and Photometer) and of the station at Fortaleza (Digissonde data), as aid to analyze these storms. The storms that had been left out by the applied method, fit in the other two categories of Aarons, with one only exception (storm of January, 02). We show that in the day of the main phase of the magnetic storm, and with presence of bubbles (according to data of the Imager and Photometer), the speed of vertical drift ~E ~B (hF=t) is below 20m/s, that is the threshold found for Anderson al., (2004) (>20m/s as condition favorable to the formation of irregularities and increase in the scintillation index). This reduction of the speed is due to solar minimum

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vivo determination of the incorporated activity of Tc-99(m)-MDP (methylene diphosphonate) in bone tissue by means of a scintillation camera requires calibration of the device. This can be carried out by using an anthropomorphic physical phantom. In this work, a new human tibia and fibula phantom is presented to estimate incorporated activity to bone tissue. A tibia and a fibula, taken from a real skeleton, were used to develop the phantom. Images were acquired of the legs of 65 volunteers at different times of incorporation (minimum of 120 and maximum of 2500 min after injection) and count rates of such a region were obtained by means of a computer program. The calibration factor obtained was then used to assess the activity in the two bents. The final result is 0.4995 kBq per cpm for technetium. The proposed method can be used both for radiation protection purposes and for metabolism studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A combined method for evaluating radon (Rn-222) and progeny (Pb-214 and Bi-214) in water was developed by using inexpensive alpha scintillation Counting and gamma ray spectrometry through NaI(Tl) scintillation detectors. A groundwater sample collected at the Pocos de Caldas alkaline massif in Brazil was submitted to the technique in order to assure its applicability by comparing the volumetric activities by different methods. Similar volumetric activity was determined for Pb-214 and Bi-214 in the sample analyzed that is compatible with the expected condition of radioactive equilibrium between these nuclides. The combined method was successfully used to analyze groundwater samples from Guarani aquifer in S (a) over tildeo Paulo State, Brazil, and the results of the measurements indicated that Pb-214 and Bi-214 provide useful information concerning the evaluation of the drinking water quality in terms of radiological aspects. This is because they are directly identified in the water samples, without the need of requiring the assumption of the establishment of the transient equilibrium condition with its parent Rn-222. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, GdAlO3:Pr3+ was successfully prepared by the Pechini method at lower temperatures when compared to others methods such as solid-state synthesis and sol-gel process. In accordance to the XRD data, the fully crystalline single-phase GdAlO3 could be obtained at 900 degrees C. Luminescence measurements indicate Gd -> Pr3+ energy transfer. In the emission spectra, the P-3(0) ->(3) H-4 (blue emission) and D-1(2) ->(3) H-4 (red emission) transitions of Pr3+ ions can be observed and the ratio between their intensities depends on the Pr3+ content due to the cross-relaxation phenomenon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A comparative study of nine assay methods for dextransucrase and related enzymes has been made. A relatively widespread method for the reaction of dextransucrase with sucrose is the measurement of the reducing value of D-fructose by alkaline 3,5-dinitrosalicylate (DNS) and thereby the amount of D-glucose incorporated into dextran. Another method is the reaction with C-14-sucrose with the addition of an aliquot to Whatman 3MM paper squares that are washed three times with methanol to remove C-14-D-fructose and unreacted C-14-sucrose, followed by counting of C-14-dextran on the paper by liquid scintillation counting (LSC). It is shown that both methods give erroneous results. The DNS reducing value method gives extremely high values due to over-oxidation of both D-fructose and dextran, and the C-14-paper square method gives significantly low values due to the removal of some of the C-14-dextran from the paper by methanol washes. In the present study, we have examined nine methods and find two that give values that are identical and are an accurate measurement of the dextransucrase reaction. They are (1) a C-14-sucrose/dextransucrase digest in which dextran is precipitated three times with three volumes of ethanol, dissolved in water, and added to paper and counted in a toluene cocktail by LSC: and (2) precipitation of dextran three times with three volumes of ethanol from a sucrose/dextransucrase digest, dried, and weighed. Four reducing value methods were examined to measure the amount of D-fructose. Three of the four (two DNS methods, one with both dextran and D-fructose and the other with only D-fructose, and the ferricyanide/arsenomolybdate method with is-fructose) gave extremely high values due to over-oxidation of D-fructose, D-glucose, leucrose, and dextran. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gd2SiO5 is among the interesting and suitable hosts for Er3+ which find extensive applications in the infrared, visible and ultraviolet spectral regions. In order to investigate its potentialities, a prior study of the spectroscopic behaviour of Er3+ substituting for Gd3+ ions in the two crystallographic sites of the host was performed. Absorption, excitation, site-selective emission and time-resolved spectroscopies were employed in the visible spectral region to study transitions between excited 4S3/2 and ground 4I15/2 states. These levels multiplets were attributed to each site separately, and their corresponding 4S3/2 lifetimes (1.8 ± 0.1 μs for site 1 and 3.2 ± 0.1 μs for site 2) were determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Equatorial F region vertical plasma drifts, spread F and anomaly responses, in the south American longitude sector during the superstorm of 30 October 2003, are analyzed using data from an array of instruments consisting of Digisondes, a VHF radar, GPS TEC and scintillation receivers in Brazil, and a Digisonde and a magnetometer in Jicamarca, Peru. Prompt penetrating eastward electric field of abnormally large intensity drove the F layer plasma up at a velocity ∼1200 ms -1 during post dusk hours in the eastern sector over Brazil. The equatorial anomaly was intensified and expanded poleward while the development of spread F/plasma bubble irregularities and GPS signal scintillations were weaker than their quiet time intensity. Significantly weaker F region response over Jicamarca presented a striking difference in the intensity of prompt penetration electric field between Peru and eastern longitudes of Brazil. The enhanced post dusk sector vertical drift over Brazil is attributed to electro-dynamics effects arising energetic particle precipitation in the South Atlantic Magnetic Anomaly (SAMA). These extraordinary results and their longitudinal differences are presented and discussed in this paper. Copyright 2008 by the American Geophysical Union.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work is presented a versatile system for X-ray excited optical luminescence (XEOL) measurements. The apparatus was assembled from a sample holder connected to an optical fiber responsibly for the acquisition of the scintillation signal. The spectrum is registered with a CCD coupled in a spectrograph provided with diffraction gratings. The system performance was analyzed by exciting GdAlO3:Eu3+ 3.0 at.% with X-rays from a diffractometer and measuring the emission spectra. The system can be used to obtain precise and reliable spectroscopic properties of samples with various conformations without the loss of the required safety when dealing with ionizing radiations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ionospheric scintillations can seriously jeopardize the reliability of the GNSS signals and consequently can cause significant error or outage on precise positioning applications. The threat is most acute at low latitudes where ionospheric irregularities are more likely to occur resulting in L-band signal scintillations. This paper describes the effort made to model the ionospheric scintillations over the Latin American region in the frame of the CIGALA project funded by the European GNSS Supervisory Authority within the 7th Framework Programme of the European Commission. Comparisons between the low-latitude model of scintillations and observations are here presented and discussed within the project perspectives. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The upcoming solar maximum, which is expected to reach its peak around May 2013, occurs at a time when our reliance on high-precision GNSS has reached unprecedented proportions. The perturbations of the ionosphere caused by increased solar activity pose a major threat to these applications. This is particularly true in equatorial regions where high exposure to solar-induced disturbances is coupled with explosive growth of precise GNSS applications. Along with the various types of solar-induced ionospheric disturbances, strong scintillations are amongst the most challenging, causing phase measurement errors up to full losses of lock for several satellites. Brazil, which heavily relies on high-precision GNSS, is one of the most affected regions due notably to the proximity to the southern crest of the ionospheric equatorial anomaly and to the South Atlantic Magnetic Anomaly. In the framework of the CIGALA project, we developed the PolaRxS™, a GNSS receiver dedicated to the monitoring of ionospheric scintillation indices not only in the GPS L1 band but for all operational and upcoming constellations and frequency bands. A network of these receivers was deployed across the whole Brazilian territory in order to first investigate and secondly to mitigate the impact of scintillation on the different signals, ensuring high precision GNSS availability and integrity in the area. This paper reports on the validation of the PolaRxS™ receiver as an ionospheric scintillation monitor and the first results of the analysis of the data collected with the CIGALA network.