984 resultados para STANDARD REFERENCE INTERVALS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dans le contexte du changement climatique, la chaleur est, depuis le début des années 2000, une préoccupation grandissante, d’abord en tant qu’enjeu sanitaire puis comme problématique affectant la qualité de vie des citoyens. Au Québec, le concept d’îlot de chaleur urbain, issu de la climatologie urbaine, a graduellement émergé dans le discours des autorités et de certains acteurs de l’aménagement. Or, on constate l’existence d’un certain décalage entre les connaissances scientifiques et l’interprétation qu’en font les urbanistes. Dans le cadre de ce mémoire, on a tenté d’identifier les facteurs explicatifs de ce décalage en s’intéressant au processus d’acquisition des connaissances des urbanistes québécois. Par le biais d’entretiens réalisés auprès des principaux acteurs ayant contribué à l’émergence de l’ICU au Québec, on a été en mesure d’identifier les éléments ayant entraîné certaines distorsions des connaissances. L’absence d’interdisciplinarité entre la climatologie urbaine et l’urbanisme tout au long du processus d’acquisition des connaissances ainsi qu’une interprétation tronquée de la carte des températures de surface expliquent principalement la nature du décalage observé.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La Fibrosis Quística es la enfermedad autosómica recesiva mas frecuente en caucásicos. En Colombia no se conoce la incidencia de la enfermedad, pero investigaciones del grupo de la Universidad del Rosario indican que podría ser relativamente alta. Objetivo: Determinar la incidencia de afectados por Fibrosis Quística en una muestra de recién nacidos de la ciudad de Bogotá. Metodología: Se analizan 8.297 muestras de sangre de cordón umbilical y se comparan tres protocolos de tamizaje neonatal: TIR/TIR, TIR/DNA y TIR/DNA/TIR. Resultados: El presente trabajo muestra una incidencia de 1 en 8.297 afectados en la muestra analizada. Conclusiones: Dada la relativamente alta incidencia demostrada en Bogotá, se justifica la implementación de Tamizaje Neonatal para Fibrosis Quística en Colombia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivo: Determinar la distribución por percentiles de la circunferencia de cintura en una población escolar de Bogotá, Colombia, pertenecientes al estudio FUPRECOL. Métodos: Estudio transversal, realizado en 3.005 niños y 2.916 adolescentes de entre 9 y 17,9 años de edad, de Bogotá, Colombia. Se tomaron medidas de peso, talla, circunferencia de cintura, circunferencia de cadera y estado de maduración sexual por auto-reporte. Se calcularon los percentiles (P3, P10, P25, P50, P75, P90 y P97) y curvas centiles según sexo y edad. Se realizó una comparación entre los valores de la circunferencia de cintura observados con estándares internacionales. Resultados: De la población general (n=5.921), el 57,0% eran chicas (promedio de edad 12,7±2,3 años). En la mayoría de los grupos etáreos la circunferencia de cintura de las chicas fue inferior a la de los chicos. El aumento entre el P50-P97 de la circunferencia de cintura , por edad, fue mínimo de 15,7 cm en chicos de 9-9.9 años y de 16,0 cm en las chicas de 11-11.9 años. Al comparar los resultados de este estudio, por grupos de edad y sexo, con trabajos internacionales de niños y adolescentes, el P50 fue inferior al reportado en Perú e Inglaterra a excepción de los trabajos de la India, Venezuela (Mérida), Estados Unidos y España. Conclusiones: Se presentan percentiles de la circunferencia de cintura según edad y sexo que podrán ser usados de referencia en la evaluación del estado nutricional y en la predicción del riesgo cardiovascular desde edades tempranas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Document design and typeface design: A typographic specification for a new Intermediate Greek-English Lexicon by CUP, accompanied by typefaces modified for the specific typographic requirements of the text. The Lexicon is a substantial (over 1400 pages) publication for HE students and academics intended to complement Liddell-Scott (the standard reference for classical Greek since the 1850s), and has been in preparation for over a decade. The typographic appearance of such works has changed very little since the original editions, largely to the lack of suitable typefaces: early digital proofs of the Lexicon utilised directly digitised versions of historical typefaces, making the entries difficult to navigate, and the document uneven in typographic texture. Close collaboration with the editors of the Lexicon, and discussion of the historical precedents for such documents informed the design at all typographic levels to achieve a highly reader-friendly results that propose a model for this kind of typography. Uniquely for a work of this kind, typeface design decisions were integrated into the wider document design specification. A rethinking of the complex typography for Greek and English based on historical editions as well as equivalent bilingual reference works at this level (from OUP, CUP, Brill, Mondadori, and other publishers) led a redefinition of multi-script typeface pairing for the specific context, taking into account recent developments in typeface design. Specifically, the relevant weighting of elements within each entry were redefined, as well as the typographic texture of type styles across the two scripts. In details, Greek typefaces were modified to emphasise clarity and readability, particularly of diacritics, at very small sizes. The relative weights of typefaces typeset side-by-side were fine-tuned so that the visual hierarchy of the entires was unambiguous despite the dense typesetting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of delta(66)Zn determinations in aerosols is around 0.05% per atomic mass unit. The method was tested on aerosols collected in Sin Paulo City, Brazil. The measurements reveal significant variations in delta(66)Zn(Imperial) ranging between -0.96 and -0.37% in coarse and between -1.04 and 0.02% in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source. We present further delta(66)Zn(Imperial) data for the standard reference material NIST SRM 2783 (delta 66Z(Imperial) = 0.26 +/- 0.10%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper reports a method for the direct and simultaneous determination of Cr and Mn in alumina by slurry sampling graphite furnace atomic absorption spectrometry (SiS-SIMAAS) using niobium carbide (NbC) as a graphite platform modifier and sodium fluoride (NaF) as a matrix modifier. 350 mu g of Nb were thermally deposited on the platform surface allowing the formation of NbC (mp 3500 degrees C) to minimize the reaction between aluminium and carbon of the pyrolytic platform, improving the graphite tube lifetime up to 150 heating cycles. A solution of 0.2 mol L(-1) NaF was used as matrix modifier for alumina dissolution as cryolite-based melt, allowing volatilization during pyrolysis step. Masses (c.a. 50 mg) of sample were suspended in 30 ml of 2.0% (v/v) of HNO(3). Slurry was manually homogenized before sampling. Aliquots of 20 mu l of analytical solutions and slurry samples were co-injected into the graphite tube with 20 mu l of the matrix modifier. In the best conditions of the heating program, pyrolysis and atomization temperatures were 1300 degrees C and 2400 degrees C, respectively. A step of 1000 degrees C was optimized allowing the alumina dissolution to form cryolite. The accuracy of the proposed method has been evaluated by the analysis of standard reference materials. The found concentrations presented no statistical differences compared to the certified values at 95% of the confidence level. Limits of detection were 66 ng g(-1) for Cr and 102 ng g(-1) for Mn and the characteristic masses were 10 and 13 pg for Cr and Mn, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for the multi-elemental determination of metals (Al, Ba, Ca, Cu, Fe, K, Mg, Mn, Sr and Zn), metalloids (B and Si), and non-metals (Cl, P and 5) in the babassu nut and mesocarp, sapucaia nut, coconut pulp, cupuassu pulp and seed, and cashew nut by axially viewed inductively coupled plasma optical emission spectrometry is presented. A diluted oxidant mixture (2 ml HNO(3) + 1 ml H(2)O(2) + 3 ml H(2)O) was used to achieve the complete decomposition of the organic matrix in a closed-vessel microwave oven. The accuracy of the entire proposed method was confirmed by standard reference material analysis (peach leaves-NIST SRM1547). The certified values showed a good agreement at a 95% confidence limit (Student`s t-test). The average RSD for repeatability of calibration solutions measurements were in the range of 1.1-6.7%. Limits of quantification (LOQ = 10 x LOD) were in the level of 0.00072-0.0532 mg/l. The macro and micronutrient ranges in the different nuts and seeds did not exceed the dietary reference intake (DRI), except for Mn in the babassu nut. (C) 2010 Published by Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The lipid profile is a group of lab tests that include triglycerides, total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C) and low-density lipoprotein cholesterol (LDL-C). However, serum non-HDL-C, Apo A-I and Apo B levels, as well as the lipids ratios (TC/HDL-C, LDL-C/HDL-C and Apo B/Apo A-I), have been described as better predictors of cardiovascular diseases. Reference intervals are tools often used to help the evaluation of the people s health state. These days, Brazilian studies still use the reference intervals of lipids and lipoproteins from other countries, ignoring differences between the populations. Therefore, this study aimed to establish reference intervals for lipids, lipoproteins and apolipoproteins in adults of Rio Grande do Norte/Brazil. Healthy individuals (96 men and 283 women) between 18 and 59years old formed the reference sample group. The samples were collected after fasting 12 to 14 hours. Information on lifestyle and dietary habits of the participants were obtained through questionnaire. The serum glucose level and renal and liver activity were evaluated by laboratory testing. The results of lipid profile were analyzed according to sex, age and mesoregion of Rio Grande do Norte, with significance level of 5% (p < 0,05). The lower and upper reference limits were identified by the 2.5 percentile and 97.5 percentile, respectively, and assurance intervals of 90% was calculated for each of these limits. Among the determinants of lipid profile analyzed, only a few significant differences were observed according to sex, but in terms of age, the groups of smaller and older ages were most likely different. When evaluated by region, the means of West region shown the most significant variations. Not many studies were useful to compare the reference intervals determined in this study. Thus, it becomes necessary to carry out similar studies in other regions of Brazil and of the world given the clinical importance of reference intervals

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reference intervals for haematologic and total plasma proteins profiles were determined for 11 physically restrained adult grey-brocket deer. Erythrocytic alterations, as discrete to moderate poikilocytosis, were observed in all animals. Red and white blood cells counts were determined by manual methodology. Obtained erythron and leukon values were slightly higher than previous reports. Statistical difference was not demonstrated between stags and hinds. No previous studies reported blood values for captive grey-brocket deer obtained by manual methods. Also, the authors suggest that future studies on deer haematology should be focused on technique evaluation and improvement, considering the unusual erythrocytic morphology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)