867 resultados para RAY-LINKING
Resumo:
The pentadentate chelating agent, 2,6-diacetylpyridinebis(S-benzyldithiocarbazate) (H2SNNNS) reacts with zinc(II) and cadmium(II) ions forming stable complexes of empirical formula, [M(SNNNS)] (M=Zn2+, Cd2+; SNNNS2 =doubly deprotonated anionic form of the Schiff base). These complexes have been characterized by a variety of physico-chemical techniques. IR and H-1 NMR spectral evidence indicate that the Schiff base coordinates to the zinc(II) and cadmium(II) ions via the pyridine nitrogen atoms, the azomethine nitrogen atoms and the mercaptide sulfur atoms. The crystal and molecular structure of the zinc(II) complex has been determined by X-ray diffraction. The complex is a dimer in which the pyridine nitrogen atom,the azomethine nitrogen atom and the thiolate sulfur atom from one ligand coordinate to one of the zinc(II) ions whereas the azomethine and thiolate sulfur atoms from another ligand complete pentacoordination around the zinc(II) ion, the ligands being coordinated in their deprotonated forms. The coordination geometry about each zinc(II) can be considered as intermediate between a square-pyramid and trigonal-bipyramid. The cadmium(II) complex is also assigned with a dimeric structure. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Regiospecific bromination of 2,4,4-trimethyl-cyclohex-2-enone was achieved and the X-ray crystal structure of 6-bromo-2,4,4-trimethyl-cyclohex-2-enone is presented.
Resumo:
9-Carboxyhexahydro-7-methoxy-4a,7-ethano-benzopyran-5-en-1-one (1) was prepared and examined by X-ray crystallography to probe its potential as a new peptide scaffold/template. The crystal structure of the anhydride precursor 7-(2-acetoxyethyl)-4-methoxy-3a,4,7,7a-tetrahydro-4,7-ethanoisobenzofuran-1,3-dione (6) is also reported.
Resumo:
The effect of electron beam radiation on a perfluoroalkoxy (PFA) resin was examined using solid-state high-speed magic angle spinning F-19 NMR spectroscopy and FT-IR spectroscopy. Samples were prepared for analysis by subjecting them to electron beam radiation in the dose range 0.5-2.0 MGy at 633 K, which is above the crystalline melting temperature. The new structures were identified and include new saturated chain ends, short and long branches, unsaturated groups, and cross-links. The radiation chemical yield (G value) of new long branch points was greater than the G value of new chain ends, suggesting that cross-linking is the net radiolytic process. This conclusion was supported by an observed decrease in the crystallinity and an increase in the optical clarity of the polymer.
Resumo:
Development of suitable membranes is a fundamental requisite for tissue and biomedical engineering applications. This work presents fish gelatin random and aligned electrospun membranes cross-linked with glutaraldehyde (GA). It was observed that the fiber average diameter and the morphology is not influenced by the GA exposure time and presents fibers with an average diameter around 250 nm. Moreover, when the gelatin mats are immersed in a phosphate buffered saline solution (PBS), they can retain as much as 12 times its initial weight of solution almost instantaneously, but the material microstructure of the fiber mats changes from the characteristic fibrous to an almost spherical porous structure. Cross-linked gelatin electrospun fiber mats and films showed a water vapor permeability of 1.37 ± 0.02 and 0.13 ± 0.10 (g.mm)/(m2.h.kPa), respectively. Finally, the processing technique and cross-linking process does not inhibit MC-3T3-E1 cell adhesion. Preliminary cell culture results showed good cell adhesion and proliferation in the cross-linked random and aligned gelatin fiber mats.
Resumo:
Thermal degradation of as electrospun chitosan membranes and samples subsequently treated with ethanol and cross-linked with glutaraldehyde (GA) have been studied by thermogravimetry (TG) coupled with an infrared spectrometer (FTIR). The influence of the electrospinning process and cross-linking in the electrospun chitosan thermal stability was evaluated. Up to three degradation steps were observed in the TG data, corresponding to water dehydration reaction at temperatures below 100 ºC, loss of side groups formed between the amine groups of chitosan and trifluoroacetic acid between 150 – 270 ºC and chitosan thermal degradation that starts around 250 ºC and goes up to 400 ºC. The Kissinger model was employed to evaluate the activation energies of the electrospun membranes during isothermal experiments and revealed that thermal degradation activation energy increases for the samples processed by electrospinning and subsequent neutralization and cross-linking treatments with respect to the neat chitosan powder.
Resumo:
Dental implant recognition in patients without available records is a time-consuming and not straightforward task. The traditional method is a complete user-dependent process, where the expert compares a 2D X-ray image of the dental implant with a generic database. Due to the high number of implants available and the similarity between them, automatic/semi-automatic frameworks to aide implant model detection are essential. In this study, a novel computer-aided framework for dental implant recognition is suggested. The proposed method relies on image processing concepts, namely: (i) a segmentation strategy for semi-automatic implant delineation; and (ii) a machine learning approach for implant model recognition. Although the segmentation technique is the main focus of the current study, preliminary details of the machine learning approach are also reported. Two different scenarios are used to validate the framework: (1) comparison of the semi-automatic contours against implant’s manual contours of 125 X-ray images; and (2) classification of 11 known implants using a large reference database of 601 implants. Regarding experiment 1, 0.97±0.01, 2.24±0.85 pixels and 11.12±6 pixels of dice metric, mean absolute distance and Hausdorff distance were obtained, respectively. In experiment 2, 91% of the implants were successfully recognized while reducing the reference database to 5% of its original size. Overall, the segmentation technique achieved accurate implant contours. Although the preliminary classification results prove the concept of the current work, more features and an extended database should be used in a future work.
Resumo:
Discovering the ways through which firms develop and maintain competitive advantage is a central research stream in management theory. The objective of this paper is to present a contribution to the discussion of the knowledge of the firm as a source of competitive advantage. The paper states that a firm's success is a consequence of its ability in the continuous development of core competencies that will sustain its competitiveness over time. Core competencies are understood as the sets of knowledge that differentiate a company strategically. The firm must discover, develop, share and update the knowledge that sustains the present and future core competencies. Knowledge management, through processes of knowledge creation and integration, is one way of doing this.
Resumo:
By acknowledging and dissecting the interconnected roles of customer satisfaction, quality, and strategic planning, this paper provides an analytical framework for creating a customer-driven organization and culture. It shows how quality starts and ends with the customer. Companies that are achieving long-term continuous improvement in quality tailored to customer satisfaction possess lasting characteristics such as customer orientation, customer consciousness, and customer responsiveness. In doing so, they liberate the quality concept from the narrow product or service focus to encompass total conformance to customer requirements in spite of the existing functionalization and departmentalization of modern complex structures. In addition to these key components, a customer-driven organization demands building and nurturing a customer satisfaction culture and value system that makes quality improvement and heightened concern for customer satisfaction a permanent aspect of organizational life.
Resumo:
This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.
Resumo:
Novel [Ru(L)(Tpms)]Cl and [Ru(L)(Tpms(Ph))]Cl complexes (L = p-cymene, benzene, or hexamethylbenzene, Tpms = tris(pyrazolyl)-methanesulfonate, Tpms(Ph) = tris(3-phenylpyrazoly)methanesulfonate) have been prepared by reaction of [Ru(L)(mu-Cl)(2)](2) with Li[Tpms] and Li[Tpms(Ph)], respectively. [Ru(p-cymene)(Tpms)]BF4 has been synthesized through a metathetic reaction of [Ru(p-cymene)(Tpms)]Cl with AgBF4. [RuCl(cod)(Tpms)] (cod = 1,5-cyclooctadiene) and [RuCl(cod)(Tpms(Ph))] are also reported, being obtained by reaction of [RuCl2(cod)(MeCN)(2)] with Li[Tpms] and Li[Tpms(Ph)], respectively. The structures of the complexes and the coordination modes of the ligands have been established by IR, NMR, and single-crystal X-ray diffraction (for [RuL(Tpms)]X (L = p-cymene or HMB, X = Cl; L = p-cymene, X = BF4)) studies. Electrochemical studies showed that each complex undergoes a single-electron R-II -> R-III oxidation at a potential measured by cyclic voltammetry, allowing to compare the electron-donor characters of the tris(pyrazolyl)methanesulfonate and arene ligands, and to estimate, for the first time, the values of the Lever E-L ligand parameter for Tmps(Ph), HMB, and cod.
Resumo:
OBJECTIVE: Various support measures useful for promoting joint change approaches to the improvement of both shiftworking arrangements and safety and health management systems were reviewed. A particular focus was placed on enterprise-level risk reduction measures linking working hours and management systems. METHODS: Voluntary industry-based guidelines on night and shift work for department stores and the chemical, automobile and electrical equipment industries were examined. Survey results that had led to the compilation of practicable measures to be included in these guidelines were also examined. The common support measures were then compared with ergonomic checkpoints for plant maintenance work involving irregular nightshifts. On the basis of this analysis, a new night and shift work checklist was designed. RESULTS: Both the guidelines and the plant maintenance work checkpoints were found to commonly cover multiple issues including work schedules and various job-related risks. This close link between shiftwork arrangements and risk management was important as shiftworkers in these industries considered teamwork and welfare services to be essential for managing risks associated with night and shift work. Four areas found suitable for participatory improvement by managers and workers were work schedules, ergonomic work tasks, work environment and training. The checklist designed to facilitate participatory change processes covered all these areas. CONCLUSIONS: The checklist developed to describe feasible workplace actions was suitable for integration with comprehensive safety and health management systems and offered valuable opportunities for improving working time arrangements and job content together.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Understanding the determinants of international performance, and in particular, export performance is key for the success of international companies. Research in this area focuses mainly on how resources and capabilities allow companies to gain competitive advantage and superior performance in external markets. Building on the Resource-Based View (RBV) and the Dynamic Capabilities Approach (DCA), this study aims at analysing the effect of intangible resources and capabilities on export performance. Specifically, this study focuses on the proposition that entrepreneurial orientation potentiates the attraction of intangible resources, namely relational and informational resources. Moreover, we propose that these resources impact export performance both directly and indirectly through dynamic capabilities.
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.