888 resultados para PFG-NMR spin echo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Systemic iron overload (IO) is considered a principal determinant in the clinical outcome of different forms of IO and in allogeneic hematopoietic stem cell transplantation (alloSCT). However, indirect markers for iron do not provide exact quantification of iron burden, and the evidence of iron-induced adverse effects in hematological diseases has not been established. Hepatic iron concentration (HIC) has been found to represent systemic IO, which can be quantified safely with magnetic resonance imaging (MRI), based on enhanced transverse relaxation. The iron measurement methods by MRI are evolving. The aims of this study were to implement and optimise the methodology of non-invasive iron measurement with MRI to assess the degree and the role of IO in the patients. An MRI-based HIC method (M-HIC) and a transverse relaxation rate (R2*) from M-HIC images were validated. Thereafter, a transverse relaxation rate (R2) from spin-echo imaging was calibrated for IO assessment. Two analysis methods, visual grading and rSI, for a rapid IO grading from in-phase and out-of-phase images were introduced. Additionally, clinical iron indicators were evaluated. The degree of hepatic and cardiac iron in our study patients and IO as a prognostic factor in patients undergoing alloSCT were explored. In vivo and in vitro validations indicated that M-HIC and R2* are both accurate in the quantification of liver iron. R2 was a reliable method for HIC quantification and covered a wider HIC range than M-HIC and R2*. The grading of IO was able to be performed rapidly with the visual grading and rSI methods. Transfusion load was more accurate than plasma ferritin in predicting transfusional IO. In patients with hematological disorders, the prevalence of hepatic IO was frequent, opposite to cardiac IO. Patients with myelodysplastic syndrome were found to be the most susceptible to IO. Pre-transplant IO predicted severe infections during the early post-transplant period, in contrast to the reduced risk of graft-versus-host disease. Iron-induced, poor transplantation results are most likely to be mediated by severe infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les hydrogels de polysaccharide sont des biomatériaux utilisés comme matrices à libération contrôlée de médicaments et comme structures modèles pour l’étude de nombreux systèmes biologiques dont les biofilms bactériens et les mucus. Dans tous les cas, le transport de médicaments ou de nutriments à l’intérieur d’une matrice d’hydrogel joue un rôle de premier plan. Ainsi, l’étude des propriétés de transport dans les hydrogels s’avère un enjeu très important au niveau de plusieurs applications. Dans cet ouvrage, le curdlan, un polysaccharide neutre d’origine bactérienne et formé d’unités répétitives β-D-(1→3) glucose, est utilisé comme hydrogel modèle. Le curdlan a la propriété de former des thermogels de différentes conformations selon la température à laquelle une suspension aqueuse est incubée. La caractérisation in situ de la formation des hydrogels de curdlan thermoréversibles et thermo-irréversibles a tout d’abord été réalisée par spectroscopie infrarouge à transformée de Fourier (FT-IR) en mode réflexion totale atténuée à température variable. Les résultats ont permis d’optimiser les conditions de gélation, menant ainsi à la formation reproductible des hydrogels. Les caractérisations structurales des hydrogels hydratés, réalisées par imagerie FT-IR, par microscopie électronique à balayage en mode environnemental (eSEM) et par microscopie à force atomique (AFM), ont permis de visualiser les différentes morphologies susceptibles d’influencer la diffusion d’analytes dans les gels. Nos résultats montrent que les deux types d’hydrogels de curdlan ont des architectures distinctes à l’échelle microscopique. La combinaison de la spectroscopie de résonance magnétique nucléaire (RMN) à gradients pulsés et de l’imagerie RMN a permis d’étudier l’autodiffusion et la diffusion mutuelle sur un même système dans des conditions expérimentales similaires. Nous avons observé que la diffusion des molécules dans les gels est ralentie par rapport à celle mesurée en solution aqueuse. Les mesures d’autodiffusion, effectuées sur une série d’analytes de diverses tailles dans les deux types d’hydrogels de curdlan, montrent que le coefficient d’autodiffusion relatif décroit en fonction de la taille de l’analyte. De plus, nos résultats suggèrent que l’équivalence entre les coefficients d’autodiffusion et de diffusion mutuelle dans les hydrogels de curdlan thermo-irréversibles est principalement due au fait que l’environnement sondé par les analytes durant une expérience d’autodiffusion est représentatif de celui exploré durant une expérience de diffusion mutuelle. Dans de telles conditions, nos résultats montrent que la RMN à gradients pulsés peut s’avérer une approche très avantageuse afin de caractériser des systèmes à libération contrôlée de médicaments. D’autres expériences de diffusion mutuelle, menées sur une macromolécule de dextran, montrent un coefficient de diffusion mutuelle inférieur au coefficient d’autodiffusion sur un même gel de curdlan. L’écart mesuré entre les deux modes de transport est attribué au volume différent de l’environnement sondé durant les deux mesures. Les coefficients d’autodiffusion et de diffusion mutuelle similaires, mesurés dans les deux types de gels de curdlan pour les différents analytes étudiés, suggèrent une influence limitée de l’architecture microscopique de ces gels sur leurs propriétés de transport. Il est conclu que les interactions affectant la diffusion des analytes étudiés dans les hydrogels de curdlan se situent à l’échelle moléculaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present extensive molecular dynamics simulations of the dynamics of diluted long probe chains entangled with a matrix of shorter chains. The chain lengths of both components are above the entanglement strand length, and the ratio of their lengths is varied over a wide range to cover the crossover from the chain reptation regime to tube Rouse motion regime of the long probe chains. Reducing the matrix chain length results in a faster decay of the dynamic structure factor of the probe chains, in good agreement with recent neutron spin echo experiments. The diffusion of the long chains, measured by the mean square displacements of the monomers and the centers of mass of the chains, demonstrates a systematic speed-up relative to the pure reptation behavior expected for monodisperse melts of sufficiently long polymers. On the other hand, the diffusion of the matrix chains is only weakly perturbed by the diluted long probe chains. The simulation results are qualitatively consistent with the theoretical predictions based on constraint release Rouse model, but a detailed comparison reveals the existence of a broad distribution of the disentanglement rates, which is partly confirmed by an analysis of the packing and diffusion of the matrix chains in the tube region of the probe chains. A coarse-grained simulation model based on the tube Rouse motion model with incorporation of the probability distribution of the tube segment jump rates is developed and shows results qualitatively consistent with the fine scale molecular dynamics simulations. However, we observe a breakdown in the tube Rouse model when the short chain length is decreased to around N-S = 80, which is roughly 3.5 times the entanglement spacing N-e(P) = 23. The location of this transition may be sensitive to the chain bending potential used in our simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The crystallization of fluoroindate glasses doped with Gd3+, Mn2+ and Cu2+ heat treated at different temperatures, ranging from the glass transition temperature (Tg) to the crystallization temperature (Tc), are investigated by electron paramagnetic resonance (EPR) and 19F nuclear magnetic resonance (NMR). The EPR spectra indicate that the Cu2+ ions in the glass are located in axially distorted octahedral sites. In the crystallized glass, the g-values agreed with those reported for Ba2ZnF6, which correspond to Cu2+ in a tetragonal compressed F- octahedron and to Cu2+ on interstitial sites with a square-planar F- co-ordination. The EPR spectra of the Mn2+ doped glasses exhibit a sextet structure due to the Mn2+ hyperfine interaction. These spectra suggest a highly ordered environment for the Mn2+ ions (close to octahedral symmetry) in the glass. The EPR spectra of the recrystallized sample exhibit resonances at the same position, suggesting that the Mn2+ ions are located in sites of highly symmetric crystalline field. The increase of the line intensity of the sextet and the decrease of the background line in the thermal treated samples suggest that the Mn2+ ions move to the highly ordered sites which contribute to the sextet structure. The EPR spectra of the Gd3+ doped glasses exhibit the typical U-spectrum of a s-state ion in a low symmetry site in disordered systems. The EPR of the crystallized glasses, in contrast, have shown a strong resonance in g ≈ 2.0, suggesting Gd3+ ions in environment close to cubic symmetry. The 19F NMR spin-lattice relaxation rates were also strongly influenced by the crystallization process that takes over in samples annealed above Tc. For the glass samples (doped or undoped) the 19F magnetization recoveries were found to be adjusted by an exponential function and the spin-lattice relaxation was characterized by a single relaxation time. In contrast, for the samples treated above Tc, the 19F magnetization-recovery becomes non-exponential. A remarkable feature of our results is that the changes in the Cu2+, Mn2+, Gd3+ EPR spectra and NMR relaxation, are always observed for the samples annealed above Tc. © 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Estabelecer um padrão de crescimento tumoral (volume) em ratos Wistar submetidos ao modelo C6 de glioblastoma multiforme por meio de imagens de ressonância magnética para posterior verificação de redução de volume tumoral com a terapia de magnetohipertermia. Métodos: Para o modelo C6, utilizamos ratos Wistar, machos, jovens, pesando entre 250 e 300 g. Após anestesiados (cetamina 55 mg/kg e xilazina 11 mg/kg) foram injetadas estereotaxicamente células tumorigênicas linhagem C6 suspensas em meio de cultura (105 células em 10 µL) no córtex frontal direito (coordenadas a partir do bregma: anteroposterior = 2,0 mm; látero-lateral = 3,0 mm; profundidade = 2,5 mm) com uma seringa Hamilton. No Grupo Controle, houve a injeção do meio de cultura sem as células. Posteriormente, foram feitas imagens mediante a técnica de imagem por ressonância magnética em 14, 21 e 28 dias após a injeção em um escâner de imagem por ressonância magnética 2.0 T (Bruker BioSpec, Germany). Para o exame, os animais foram anestesiados com cetamina 55 mg/kg e xilazina 11 mg/kg. Multifatias coronais foram adquiridas utilizando uma sequência spin-echo padrão com os seguintes parâmetros: TR/TE = 4,000 ms/67,1 ms, FOV = 3,50, Matrix 192, slice thickness = 0,4 mm e slice separation = 0 mm. Resultados: A análise das imagens de ressonância magnética do tumor possibilitou a clara visualização da massa tumoral, sendo possível ainda estabelecer parâmetros de volume tumoral nos diferentes dias analisados. O volume de 14 dias após a indução do foi de 13,7 ± 2,5 mm3 . Aos 21 dias, o volume alcançado foi de 31,7 ± 6,5 mm3 e, aos 28 dias, a massa tumoral atingiu 122,1 ± 11,8 mm3 . Conclusão: Estes resultados mostraram a possiblidade de avaliação do volume tumoral no modelo C6 em ratos, o que possibilitará, no futuro, a aplicação da terapia de magnetohipertermia bem como verificação de seus resultados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Structure and folding of membrane proteins are important issues in molecular and cell biology. In this work new approaches are developed to characterize the structure of folded, unfolded and partially folded membrane proteins. These approaches combine site-directed spin labeling and pulse EPR techniques. The major plant light harvesting complex LHCIIb was used as a model system. Measurements of longitudinal and transversal relaxation times of electron spins and of hyperfine couplings to neighboring nuclei by electron spin echo envelope modulation(ESEEM) provide complementary information about the local environment of a single spin label. By double electron electron resonance (DEER) distances in the nanometer range between two spin labels can be determined. The results are analyzed in terms of relative water accessibilities of different sites in LHCIIb and its geometry. They reveal conformational changes as a function of micelle composition. This arsenal of methods is used to study protein folding during the LHCIIb self assembly and a spatially and temporally resolved folding model is proposed. The approaches developed here are potentially applicable for studying structure and folding of any protein or other self-assembling structure if site-directed spin labeling is feasible and the time scale of folding is accessible to freeze-quench techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Der Haupt-Lichtsammelkomplex (LHCII) des Photosyntheseapparates höherer Pflanzen gehört zu den häufigsten Membranproteinen der Erde. Seine Kristallstruktur ist bekannt. Das Apoprotein kann rekombinant in Escherichia coli überexprimiert und somit molekularbiologisch vielfältig verändert werden. In Detergenzlösung besitzt das denaturierte Protein die erstaunliche Fähigkeit, sich spontan zu funktionalen Protein-Pigment-Komplexen zu organisieren, welche strukturell nahezu identisch sind mit nativem LHCII. Der Faltungsprozess findet in vitro im Zeitbereich von Sekunden bis Minuten statt und ist abhängig von der Bindung der Cofaktoren Chlorophyll a und b sowie verschiedenen Carotinoiden.rn Diese Eigenschaften machen LHCII besonders geeignet für Strukturuntersuchungen mittels der elektronenparamagnetischen Resonanz (EPR)-Spektrokopie. Diese setzt eine punktspezifische Spinmarkierung des LHCII voraus, die in dieser Arbeit zunächst optimiert wurde. Einschließlich der Beiträge Anderer stand eine breite Auswahl von über 40 spinmarkierten Mutanten des LHCII bereit, einen N-terminalen „Cys walk“ eingeschlossen. Weder der hierfür notwendige Austausch einzelner Aminosäuren noch die Anknüpfung des Spinmarkers beeinträchtigten die Funktion des LHCII. Zudem konnte ein Protokoll zur Präparation heterogen spinmarkierter LHCII-Trimere entwickelt werden, also von Trimeren, die jeweils nur ein Monomer mit einer Spinmarkierung enthalten.rn Spinmarkierte Proben des Detergenz-solubilisierten LHCII wurden unter Verwendung verschiedener EPR-Techniken strukturell analysiert. Als besonders aussagekräftig erwies sich die Messung der Wasserzugänglichkeit einzelner Aminosäurepositionen anhand der Electron Spin Echo Envelope Modulation (ESEEM). In Kombination mit der etablierten Double Electron-Electron Resonance (DEER)-Technik zur Detektion von Abständen zwischen zwei Spinmarkern wurde der membranständige Kernbereich des LHCII in Lösung eingehend untersucht und strukturell der Kristallstruktur für sehr ähnlich befunden. Die Vermessung kristallographisch nicht erfasster Bereiche nahe dem N-Terminus offenbarte die schon früher detektierte Strukturdynamik der Domäne in Abhängigkeit des Oligomerisierungsgrades. Der neue, noch zu vervollständigende Datensatz aus Abstandsverteilungen und ESEEM-Wasserzugänglichkeiten monomerer wie trimerer Proben sollte in naher Zukunft die sehr genaue Modellierung der N-terminalen Domäne des LHCII ermöglichen.rn In einem weiteren Abschnitt der Arbeit wurde die Faltung des LHCII-Apoproteins bei der LHCII-Assemblierung in vitro untersucht. Vorausgegangene fluoreszenzspektroskopi-sche Arbeiten hatten gezeigt, dass die Bindung von Chlorophyll a und b in aufeinanderfolgenden Schritten im Zeitbereich von weniger als einer Minute bzw. mehreren Minuten erfolgten. Sowohl die Wasserzugänglichkeit einzelner Aminosäurepositionen als auch Spin-Spin-Abstände änderten sich in ähnlichen Zeitbereichen. Die Daten deuten darauf hin, dass die Ausbildung der mittleren Transmembran-Helix mit der schnelleren Chlorophyll-a-Bindung einhergeht, während sich die Superhelix aus den beiden anderen Transmembranhelices erst im langsameren Schritt, zusammen mit der Chlorophyll-b-Bindung, ausbildet.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To prospectively determine on T2 cartilage maps the effect of unloading during a clinical magnetic resonance (MR) examination in the postoperative follow-up of patients after matrix-associated autologous chondrocyte transplantation (MACT) of the knee joint. Materials and Methods: Ethical approval for this study was provided by the local ethics commission, and written informed consent was obtained. Thirty patients (mean age, 35.4 years +/- 10.5) with a mean postoperative follow-up period of 29.1 months +/- 24.4 were enrolled. A multiecho spin-echo T2-weighted sequence was performed at the beginning (early unloading) and end (late unloading) of the MR examination, with an interval of 45 minutes. Mean and zonal region of interest T2 measurements were obtained in control cartilage and cartilage repair tissue. Statistical analysis of variance was performed. Results: The change in T2 values of control cartilage (early unloading, 50.2 msec +/- 8.4; late unloading, 51.3 msec +/- 8.5) was less pronounced than the change in T2 values of cartilage repair tissue (early unloading, 51.8 msec +/- 11.7; late unloading, 56.1 msec +/- 14.4) (P = .024). The difference between control cartilage and cartilage repair tissue was not significant for early unloading (P = .314) but was significant for late unloading (P = .036). Zonal T2 measurements revealed a higher dependency on unloading for the superficial cartilage layer. Conclusion: Our results suggest that T2 relaxation can be used to assess early and late unloading values of articular cartilage in a clinical setting and that the time point of the quantitative T2 measurement affects the differentiation between native and abnormal articular cartilage. (c) RSNA, 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fast quantitative MRI has become an important tool for biochemical characterization of tissue beyond conventional T1, T2, and T2*-weighted imaging. As a result, steady-state free precession (SSFP) techniques have attracted increased interest, and several methods have been developed for rapid quantification of relaxation times using steady-state free precession. In this work, a new and fast approach for T2 mapping is introduced based on partial RF spoiling of nonbalanced steady-state free precession. The new T2 mapping technique is evaluated and optimized from simulations, and in vivo results are presented for human brain at 1.5 T and for human articular cartilage at 3.0 T. The range of T2 for gray and white matter was from 60 msec (for the corpus callosum) to 100 msec (for cortical gray matter). For cartilage, spatial variation in T2 was observed between deep (34 msec) and superficial (48 msec) layers, as well as between tibial (33 msec), femoral, (54 msec) and patellar (43 msec) cartilage. Excellent correspondence between T2 values derived from partially spoiled SSFP scans and the ones found with a reference multicontrast spin-echo technique is observed, corroborating the accuracy of the new method for proper T2 mapping. Finally, the feasibility of a fast high-resolution quantitative partially spoiled SSFP T2 scan is demonstrated at 7.0 T for human patellar cartilage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To perform baseline T(2) mapping of the hips of healthy volunteers, focusing on topographic variation, because no detailed study has involved hips. T(2) mapping is a quantitative magnetic resonance imaging (MRI) technique that evaluates cartilage matrix components. MATERIALS AND METHODS: Hips of 12 healthy adults (six men and six women; mean age = 29.5 +/- 4.9 years) were studied with a 3.0-Tesla MRI system. T(2) measurement in the oblique-coronal plane used a multi-spin-echo (MSE) sequence. Femoral cartilage was divided into 12 radial sections; acetabular cartilage was divided into six radial sections, and each section was divided into two layers representing the superficial and deep halves of the cartilage. T(2) of these sections and layers were measured. RESULTS: Femoral cartilage T(2) was the shortest (-20 degrees to 20 degrees and -10 degrees to 10 degrees , superficial and deep layers), with an increase near the magic angle (54.7 degrees ). Acetabular cartilage T(2) in both layers was shorter in the periphery than the other parts, especially at 20 degrees to 30 degrees . There were no significant differences in T(2) between right and left hips or between men and women. CONCLUSION: Topographic variation exists in hip cartilage T(2) in young, healthy adults. These findings should be taken into account when T(2) mapping is applied to patients with degenerative cartilage. J. Magn. Reson. Imaging 2007;26:165-171. (c) 2007 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to investigate the effect of magnetization transfer on multislice T(1) and T(2) measurements of articular cartilage. MATERIALS AND METHODS: A set of phantoms with different concentrations of collagen and contrast agent (Gd-DTPA(2-)) were used for the in vitro study. A total of 20 healthy knees were used for the in vivo study. T(1) and T(2) measurements were performed using fast-spin-echo inversion-recovery (FSE-IR) sequence and multi-spin-echo (MSE) sequence, respectively, in both in vitro and in vivo studies. We investigated the difference in T(1) and T(2) values between that measured by single-slice acquisition and that measured by multislice acquisition. RESULTS: Regarding T(1) measurement, a large drop of T(1) in all slices and also a large interslice variation in T(1) were observed when multislice acquisition was used. Regarding T(2) measurement, a substantial drop of T(2) in all slices was observed; however, there was no apparent interslice variation when multislice acquisition was used. CONCLUSION: This study demonstrated that the adaptation of multislice acquisition technique for T(1) measurement using FSE-IR methodology is difficult and its use for clinical evaluation is problematic. In contrast, multislice acquisition for T(2) measurement using MSE was clinically applicable if inaccuracies caused by multislice acquisition were taken into account. J. Magn. Reson. Imaging 2007;26:109-117. (c) 2007 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: An optimized, longitudinal in vivo magnetic resonance vessel wall-imaging protocol was evaluated regarding its capability of detecting differences in the time-dependent atherosclerotic lesion progression in the aortic arch between ApoE(-/-) and double-deficient ApoE(-/-)/TNF(-/-) mice at comparatively early plaque development stages. MATERIALS AND METHODS: Seven ApoE(-/-) and seven ApoE(-/-)/TNF(-/-) female mice underwent MRI at 11.75 teslas at four stages up to 26 weeks of age. A double-gated spin-echo MRI sequence was used with careful perpendicular slice positioning to visualize the vessel wall of the ascending aortic arch. RESULTS: Wall-thickness progression measured with MRI was significant at 11 weeks of age in ApoE(-/-) mice, but only at 26 weeks in ApoE(-/-)/TNF(-/-) mice. A significant correlation was found between MRI wall-thickness and lesion area determined on histology. CONCLUSION: MRI was shown to be sensitive enough to reveal subtle genetically-induced differences in lesion progression at ages earlier than 25 weeks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.