983 resultados para OCCLUSAL CONTACT AREA


Relevância:

80.00% 80.00%

Publicador:

Resumo:

With an increasing number of mature fields, heavy oil recovery has performed one of the great challenges of the oil industry. The Brazilian Northeast, for example, has numerous heavy oil reservoirs are explored with the use of thermal methods. Among the types of methods used for heavy oil, there is the method of in-situ combustion, a technique in which heat is produced within the container, unlike the injection of heated fluid when the heat is generated at the surface and transported to the reservoir. In this type of process, it is common to use vertical wells as injectors and producers. However, methods which use horizontal wells like oil producers are increasingly studied because of greater contact area between the formation and combustion front. Thus, the main objective of this work was to study the different configurations of wells (CIS THAITM and CAGD) in the process of in-situ combustion in oil recovery using a semi-synthetic tank with Brazilian Northeast features. The method "toe-to-heel air injection" (THAITM) is a process of enhanced oil recovery, which is the integration of in-situ combustion with technological advances in drilling horizontal wells. This method uses horizontal wells such as oil producers, keeping vertical injection wells for injecting air. The oil drain process by differential gravitational assisted with combustion (CAGD) is an integrated, in this configuration the horizontal injector well is drilled at the top formation with a horizontal production well in the lower section. The simulations were performed in a commercial program of thermal processes, called "STARS" (Steam, Thermal, and Advanced Processes Reservoir Simulator), the company CMG (Computer Modelling Group). An analysis of the air flow injection was performed and it was found that each method had a maximum injection to the base model, a show that through this air injection limit was reduced cumulative production of oil. Analyses of operating parameters were used: injection flow, configuration and completion of wells. In the sensitivity analysis we found that the air injection flow showed greater influence on THAI method, since the CIS method the completion of the wells was the most influential parameter and CAGD configuration wells showed the greatest influence in the recovered fraction. The economic results have shown that the best case obtained in CAGD method because, despite having higher initial cost showed the best financial return compared to the best cases the CIS and THAI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With an increasing number of mature fields, heavy oil recovery has performed one of the great challenges of the oil industry. The Brazilian Northeast, for example, has numerous heavy oil reservoirs are explored with the use of thermal methods. Among the types of methods used for heavy oil, there is the method of in-situ combustion, a technique in which heat is produced within the container, unlike the injection of heated fluid when the heat is generated at the surface and transported to the reservoir. In this type of process, it is common to use vertical wells as injectors and producers. However, methods which use horizontal wells like oil producers are increasingly studied because of greater contact area between the formation and combustion front. Thus, the main objective of this work was to study the different configurations of wells (CIS THAITM and CAGD) in the process of in-situ combustion in oil recovery using a semi-synthetic tank with Brazilian Northeast features. The method "toe-to-heel air injection" (THAITM) is a process of enhanced oil recovery, which is the integration of in-situ combustion with technological advances in drilling horizontal wells. This method uses horizontal wells such as oil producers, keeping vertical injection wells for injecting air. The oil drain process by differential gravitational assisted with combustion (CAGD) is an integrated, in this configuration the horizontal injector well is drilled at the top formation with a horizontal production well in the lower section. The simulations were performed in a commercial program of thermal processes, called "STARS" (Steam, Thermal, and Advanced Processes Reservoir Simulator), the company CMG (Computer Modelling Group). An analysis of the air flow injection was performed and it was found that each method had a maximum injection to the base model, a show that through this air injection limit was reduced cumulative production of oil. Analyses of operating parameters were used: injection flow, configuration and completion of wells. In the sensitivity analysis we found that the air injection flow showed greater influence on THAI method, since the CIS method the completion of the wells was the most influential parameter and CAGD configuration wells showed the greatest influence in the recovered fraction. The economic results have shown that the best case obtained in CAGD method because, despite having higher initial cost showed the best financial return compared to the best cases the CIS and THAI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A large series of laboratory ice crushing experiments was performed to investigate the effects of external boundary condition and indenter contact geometry on ice load magnitude under crushing conditions. Four boundary conditions were considered: dry cases, submerged cases, and cases with the presence of snow and granular ice material on the indenter surface. Indenter geometries were a flat plate, wedge shaped indenter, (reverse) conical indenter, and spherical indenter. These were impacted with artificially produced ice specimens of conical shape with 20° and 30° cone angles. All indenter – ice combinations were tested in dry and submerged environments at 1 mm/s and 100 mm/s indentation rates. Additional tests with the flat indentation plate were conducted at 10 mm/s impact velocity and a subset of scenarios with snow and granular ice material was evaluated. The tests were performed using a material testing system (MTS) machine located inside a cold room at an ambient temperature of - 7°C. Data acquisition comprised time, vertical force, and displacement. In several tests with the flat plate and wedge shaped indenter, supplementary information on local pressure patterns and contact area were obtained using tactile pressure sensors. All tests were recorded with a high speed video camera and still photos were taken before and after each test. Thin sections were taken of some specimens as well. Ice loads were found to strongly depend on contact condition, interrelated with pre-existing confinement and indentation rate. Submergence yielded higher forces, especially at the high indentation rate. This was very evident for the flat indentation plate and spherical indenter, and with restrictions for the wedge shaped indenter. No indication was found for the conical indenter. For the conical indenter it was concluded that the structural restriction due to the indenter geometry was dominating. The working surface for the water to act was not sufficient to influence the failure processes and associated ice loads. The presence of snow and granular ice significantly increased the forces at the low indentation rate (with the flat indentation plate) that were higher compared to submerged cases and far above the dry contact condition. Contact area measurements revealed a correlation of higher forces with a concurrent increase in actual contact area that depended on the respective boundary condition. In submergence, ice debris constitution was changed; ice extrusion, as well as crack development and propagation were impeded. Snow and granular ice seemed to provide additional material sources for establishing larger contact areas. The dry contact condition generally had the smallest real contact area, as well as the lowest forces. The comparison of nominal and measured contact areas revealed distinct deviations. The incorporation of those differences in contact process pressures-area relationships indicated that the overall process pressure was not substantially affected by the increased loads.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A perda de dentes além de afectar a mastigação e a estética, altera também o equilíbrio do sistema estomatognático, observando-se de imediato alterações na posição dos dentes adjacentes e dos dentes oponentes. Torna-se, portanto, imprescindível para a reposição da saúde oral do paciente a reabilitação com recurso a próteses fixas ou removíveis. No que diz respeito às próteses parciais removíveis (PPR´s) estas visam a substituição dos dentes perdidos, sendo facilmente removidas e inseridas pelo paciente, sem qualquer intervenção do médico dentista e, apoiam-se directamente na mucosa e nos dentes. Enquanto as PPR´s acrílicas são suportadas pela mucosa, mediante uma ampla área de contacto, as próteses esqueléticas são suportadas pelos dentes pilares através da colocação de retentores. No caso específico das PPR´s, é fundamental que o profissional de saúde tenha em consideração a importância do planeamento correcto e adequado da reabilitação oral. Para isso, pode e deve utilizar o paralelómetro, determinando assim correctamente a localização dos planos-guia, dos apoios e retentores necessários. Guiando-se por estes princípios fundamentais, qualquer reabilitação com recurso às PPR´s pode ser bem sucedida quer a nível estético quer a nível funcional.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stromules are motile extensions of the plastid envelope membrane, whose roles are not fully understood. They are present on all plastid types but are more common and extensive on non-green plastids that are sparsely distributed within the cell. During tomato fruit ripening, chloroplasts in the mesocarp tissue differentiate into chromoplasts and undergo major shifts in morphology. In order to understand what factors regulate stromule formation, we analysed stromule biogenesis in tobacco hypocotyls and in two distinct plastid populations in tomato mesocarp. We show that increases in stromule length and frequency are correlated with chromoplast differentiation, but only in one plastid population where the plastids are larger and less numerous. We used tobacco hypocotyls to confirm that stromule length increases as plastids become further apart, suggesting that stromules optimise the plastid-cytoplasm contact area. Furthermore, we demonstrate that ectopic chloroplast components decrease stromule formation on tomato fruit chromoplasts, whereas preventing chloroplast development leads to increased numbers of stromules. Inhibition of fruit ripening has a dramatic impact on plastid and stromule morphology, underlining that plastid differentiation status, and not cell type, is a significant factor in determining the extent of plastid stromules. By modifying the plastid surface area, we propose that stromules enhance the specific metabolic activities of plastids. This is an electronic version of an Article published in The Plant Journal, August 2004, Volume 39, pp. 655-667. Copyright 2004 Blackwell Publishing Ltd and The Society for Experimental Biology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Liquid-solid interactions become important as dimensions approach mciro/nano-scale. This dissertation focuses on liquid-solid interactions in two distinct applications: capillary driven self-assembly of thin foils into 3D structures, and droplet wetting of hydrophobic micropatterned surfaces. The phenomenon of self-assembly of complex structures is common in biological systems. Examples include self-assembly of proteins into macromolecular structures and self-assembly of lipid bilayer membranes. The principles governing this phenomenon have been applied to induce self-assembly of millimeter scale Si thin films into spherical and other 3D structures, which are then integrated into light-trapping photovoltaic (PV) devices. Motivated by this application, we present a generalized analytical study of the self-folding of thin plates into deterministic 3D shapes, through fluid-solid interactions, to be used as PV devices. This study consists of developing a model using beam theory, which incorporates the two competing components — a capillary force that promotes folding and the bending rigidity of the foil that resists folding into a 3D structure. Through an equivalence argument of thin foils of different geometry, an effective folding parameter, which uniquely characterizes the driving force for folding, has been identified. A criterion for spontaneous folding of an arbitrarily shaped 2D foil, based on the effective folding parameter, is thus established. Measurements from experiments using different materials and predictions from the model match well, validating the assumptions used in the analysis. As an alternative to the mechanics model approach, the minimization of the total free energy is employed to investigate the interactions between a fluid droplet and a flexible thin film. A 2D energy functional is proposed, comprising the surface energy of the fluid, bending energy of the thin film and gravitational energy of the fluid. Through simulations with Surface Evolver, the shapes of the droplet and the thin film at equilibrium are obtained. A critical thin film length necessary for complete enclosure of the fluid droplet, and hence successful self-assembly into a PV device, is determined and compared with the experimental results and mechanics model predictions. The results from the modeling and energy approaches and the experiments are all consistent. Superhydrophobic surfaces, which have unique properties including self-cleaning and water repelling are desired in many applications. One excellent example in nature is the lotus leaf. To fabricate these surfaces, well designed micro/nano- surface structures are often employed. In this research, we fabricate superhydrophobic micropatterned Polydimethylsiloxane (PDMS) surfaces composed of micropillars of various sizes and arrangements by means of soft lithography. Both anisotropic surfaces, consisting of parallel grooves and cylindrical pillars in rectangular lattices, and isotropic surfaces, consisting of cylindrical pillars in square and hexagonal lattices, are considered. A novel technique is proposed to image the contact line (CL) of the droplet on the hydrophobic surface. This technique provides a new approach to distinguish between partial and complete wetting. The contact area between droplet and microtextured surface is then measured for a droplet in the Cassie state, which is a state of partial wetting. The results show that although the droplet is in the Cassie state, the contact area does not necessarily follow Cassie model predictions. Moreover, the CL is not circular, and is affected by the micropatterns, in both isotropic and anisotropic cases. Thus, it is suggested that along with the contact angle — the typical parameter reported in literature quantifying wetting, the size and shape of the contact area should also be presented. This technique is employed to investigate the evolution of the CL on a hydrophobic micropatterned surface in the cases of: a single droplet impacting the micropatterned surface, two droplets coalescing on micropillars, and a receding droplet resting on the micropatterned surface. Another parameter which quantifies hydrophobicity is the contact angle hysteresis (CAH), which indicates the resistance of the surface to the sliding of a droplet with a given volume. The conventional methods of using advancing and receding angles or tilting stage to measure the resistance of the micropatterned surface are indirect, without mentioning the inaccuracy due to the discrete and stepwise motion of the CL on micropillars. A micronewton force sensor is utilized to directly measure the resisting force by dragging a droplet on a microtextured surface. Together with the proposed imaging technique, the evolution of the CL during sliding is also explored. It is found that, at the onset of sliding, the CL behaves as a linear elastic solid with a constant stiffness. Afterwards, the force first increases and then decreases and reaches a steady state, accompanied with periodic oscillations due to regular pinning and depinning of the CL. Both the maximum and steady state forces are primarily dependent on area fractions of the micropatterned surfaces in our experiment. The resisting force is found to be proportional to the number of pillars which pin the CL at the trailing edge, validating the assumption that the resistance mainly arises from the CL pinning at the trailing edge. In each pinning-and-depinning cycle during the steady state, the CL also shows linear elastic behavior but with a lower stiffness. The force variation and energy dissipation involved can also be determined. This novel method of measuring the resistance of the micropatterned surface elucidates the dependence on CL pinning and provides more insight into the mechanisms of CAH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The metalceramic crowns are usually used in dentistry because they provide a resistant structure due to its metallic base and its aesthetics from the porcelain that recovers this structure. To manufacture these crowns, a series of stages should be accomplished in the prosthetic laboratories, and many variables can influence its success. Changes in these variables cause alterations in the metallic alloy and in the porcelain, so, as consequence, in the adhesion between them. The composition of the metal alloy can be modified by recasting alloys, a common practice in some prosthetic laboratories. The aim of this paper is to make a systematic study investigating metalceramic crowns as well as analyzing the effect of recasting Ni-Cr alloys. Another variable which can influence the mechanism of metalceramic union is the temperature used in firing porcelain procedure. Each porcelain has to be fired in a fixed temperature which is determined by the manufacturer and its change can cause serious damages. This research simulate situations that may occur on laboratory procedures and observe their consequences in the quality of the metalceramic union. A scanning eletron microscopy and an optic microscopy were accomplish to analyse the metal-ceramic interface. No differences have been found when remelting alloys were used. The microhardness were similar in Ni-Cr alloys casted once, twice and three times. A wettability test was accomplished using a software developed at the Laboratório de Processamento de Materiais por Plasma, on the Universidade Federal do Rio Grande do Norte. No differences were found in the contact angle between the solid surface (metallic substratum) and the tangencial plane to the liquid surface (opaque). To analyse if the temperature of porcelain firing procedure could influence the contact area between metal and porcelain, a variation in its final temperature was achieve from 980° to 955°C. Once more, no differences have been found

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente estudo teve como principal objetivo a descrição, a análise e a comparação de parâmetros relacionados com o apoio plantar em idosos, através do método da baropodometria eletrónica, que oferece a avaliação das variáveis temporais e espaciais na postura estática e na marcha. Ademais, teve a finalidade de medir e comparar a distribuição da pressão plantar num grupo de idosos, institucionalizados e não institucionalizados, com e sem historial de quedas nos últimos 12 meses, para verificar se há um padrão comum ou divergente de apoio plantar, aspetos biomecânicos e diferenças significativas na marcha entre estes dois grupos e sua relação com a ocorrência de quedas. A amostra foi composta por 160 idosos, 80 institucionalizados e 80 não institucionalizados, onde foi realizado um levantamento das variáveis sociodemográficas como: idade, género, o índice de massa corporal (IMC), a ocorrência de quedas nos últimos 12 meses, a existência de patologias e a prática de atividade física. Foram analisadas, através da plataforma de pressão, a distribuição das pressões plantares, os picos de pressão plantar média e máxima, área de superfície plantar e a largura da base de sustentação na postura estática e, relativamente às variáveis temporais na postura dinâmica, foram avaliadas a duração do passo e o tempo de contato plantar, no momento da fase de apoio e propulsão da marcha. Foi analisada a correlação destas variáveis com a ocorrência de quedas. Foram identificados maiores valores de pressão média e máxima, na postura estática e dinâmica, nos idosos não institucionalizados. Na comparação entre os grupos, foram encontradas diferenças estatisticamente significativas em grande parte das variáveis na postura estática, especialmente aumento da largura da base (p=0,048) e, na postura dinâmica, a duração do passo e do tempo de contato do pé no solo (p=0,000) foram maiores nos idosos institucionalizados. O avançar da idade, o aumento na duração do passo e do tempo de contato do pé no solo, bem como a diminuição dos valores das pressões plantares apresentaram correlação com a ocorrência de quedas na amostra total de idosos, especialmente nos idosos institucionalizados. Entretanto, as variáveis índice de massa corporal e largura da base de sustentação não influenciaram na ocorrência de quedas na amostra total de idosos. Estes resultados demonstram a importância da análise do apoio plantar em idosos, pois alterações na distribuição das pressões plantares podem constituir um fator de risco para quedas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigated the effect of plasma treatment on changes of surface wettability of wood flooring from two Brazilian tropical species, Hymenaea spp. (rode locus) and Tabebuia spp. (lapacho). Wood flooring samples were plasma treated at low pressure in a helium atmosphere. Energy level was set at 100 W and four glow discharge times (5, 15, 30 and 45 s) were tested. Changes in wettability were investigated by measuring apparent contact angle, droplet volume and spreading contact area. The results showed less susceptibility of lapacho wood to the plasma treatments, while reduction of apparent contact angle in rode locus wood reached up to 76% for longer discharge times. In general, discharge time of 15 s produced the same effect as discharge of 45 s on wettability, which is important for industrial applications. Visual analyses revealed increase of water droplet spreading on lapacho wood surface, even though the variation of spreading contact area was not significant. Plasma treatment is feasible to improve wettability of tropical woods. Nevertheless, these findings should be investigated further due to the intrinsic characteristics of woods from tropical species.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Associations between socio-demographic factors, water contact patterns and Schistosoma mansoni infection were investigated in 506 individuals (87% of inhabitants over 1 year of age) in an endemic area in Brazil (Divino), aiming at determining priorities for public health measures to prevent the infection. Those who eliminated S. mansoni eggs (n = 198) were compared to those without eggs in the stools (n = 308). The following explanatory variables were considered: age, sex, color, previous treatment with schistosomicide, place of birth, quality of the houses, water supply for the household, distance from houses to stream, and frequency and reasons for water contact. Factors found to be independently associated with the infection were age (10-19 and > 20 yrs old), and water contact for agricultural activities, fishing, and swimming or bathing (Adjusted relative odds = 5.0, 2.4, 3.2, 2.1 and 2.0, respectively). This suggests the need for public health measures to prevent the infection, emphasizing water contact for leisure and agricultural activities in this endemic area.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A total of 256 sites in 11 habitats were surveyed for Biomphalaria in Melquiades rural area (State of Minas Gerais) in August and November 1999 and in March 2000. Of the 1,780 Biomphalaria collected, 1,721 (96.7%) were B. glabrata and 59 (3.3%) B. straminea. Snails were found in all habitats except in wells, with the largest mean numbers in tanks, seepage ponds and canals, and the smallest numbers in springs, rice fields and fishponds. People's knowledge of the occurrence of Biomphalaria at the collection sites and the presence of Biomphalaria ova were strongly correlated with the occurrence of snails, and distance between houses and collection sites, as well as water velocity were inversely correlated with Biomphalaria occurrence (p < 0.001). The strongest predictor o f Biomphalaria occurrence was the presence of tilapia fish in fishponds. Fourteen Biomphalaria (0.8% of all snails) found at 6 sites were infected with Schistosoma mansoni. Suggestions are made for the utilization of local people's knowledge in snail surveys and further studies are recommended on the possible use of tilapia for biological control of Biomphalaria in fishponds, as well as modeling of S. mansoni transmission and reinfection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of an e-learning program on the validity and reproducibility of the International Caries Detection and Assessment System (ICDAS) in detecting occlusal caries. For the study, 170 permanent molars were selected. Four dentists in Switzerland who had no previous contact with ICDAS examined the teeth before and after the e-learning program and scored the sites according to ICDAS. Teeth were histologically prepared and assessed for caries extension. The significance level was set at 0.05. Sensitivity before and after the e-learning program was 0.80 and 0.77 (D1), 0.72 and 0.63 (D2), and 0.74 and 0.67 (D3,4), respectively. Specificity was 0.64 and 0.69 (D1), 0.70 and 0.81 (D2), and 0.81 and 0.87 (D3,4). A McNemar test did not show any difference between the values of sensitivity, specificity, accuracy, and area under the ROC curve (AUC) before and after the e-learning program. The averages of wK values for interexaminer reproducibility were 0.61 (before) and 0.66 (after). Correlation with histology presented wK values of 0.62 (before) and 0.63 (after). A Wilcoxon test showed a statistically significant difference between before and after the e-learning program. In conclusion, even though ICDAS performed well in detecting occlusal caries, the e-learning program did not have any statistically significant effect on its performance by these experienced dentists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study proposed to evaluate the mandibular biomechanics in the posterior dentition based on experimental and computational analyses. The analyses were performed on a model of human mandible, which was modeled by epoxy resin for photoelastic analysis and by computer-aided design for finite element analysis. To standardize the evaluation, specific areas were determined at the lateral surface of mandibular body. The photoelastic analysis was configured through a vertical load on the first upper molar and fixed support at the ramus of mandible. The same configuration was used in the computer simulation. Force magnitudes of 50, 100, 150, and 200 N were applied to evaluate the bone stress. The stress results presented similar distribution in both analyses, with the more intense stress being at retromolar area and oblique line and alveolar process at molar level. This study presented the similarity of results in the experimental and computational analyses and, thus, showed the high importance of morphology biomechanical characterization at posterior dentition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate four different approaches to the decision of changing or not defective amalgam restorations in first primary molar teeth concerning the loss of dental structure. Ditched amalgam restorations (n = 11) were submitted to four different treatments, as follows: Control group - polishing and finishing of the restorations were carried out; Amalgam group - the ditched amalgam restorations were replaced by new amalgam restorations; Composite resin group - the initial amalgam restorations were replaced by composite resin restorations; Flowable resin group - the ditching around the amalgam restorations was filled with flowable resin. Images of the sectioned teeth were made and the area of the cavities before and after the procedures was determined by image analysis software to assess structural loss. The data were submitted to ANOVA complemented by the Student Newman Keuls test (p < 0.05). The cavities in all the groups presented significantly greater areas after the procedures. However, the amalgam group showed more substantial dental loss. The other three groups presented no statistically significant difference in dental structure loss after the re-treatments. Thus, replacing ditched amalgam restorations by other similar restorations resulted in a significant dental structure loss while maintaining them or replacing them by resin restorations did not result in significant loss.