243 resultados para Moldagem (Fundição)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of composite materials and alternative is being increased every day, as it becomes more widespread awareness that the use of renewable and not harmful to the environment is part of a new environmentally friendly model. Since its waste (primarily fiberglass) can not be easily recycled by the difficulty that still exists in this process, since they have two phases mixed, a polymeric matrix thermoset difficult to recycle because it is infusible and phase of fiber reinforcements. Thermoset matrix composites like Polyester + fiberglass pose a threat due to excessive discharge. Aiming to minimize this problem, aimed to reuse the composite Polyester + fiber glass, through the wastes obtained by the grinding of knifes and balls. These residues were incorporated into the new composite Polyester/Fiberglass for hot compression mold and compared tribological to composites with filler CaCO3, generally used as filler, targeting a partial replacement of CaCO3 by such waste. The composites were characterized by thermal analysis (TGA, DSC and DMA), by the surface integrity (roughness determination, contact angle and surface energy), mechanical properties (hardness) and tribological tests (wear and coefficient of dynamic friction) in order to evaluate the effect of loads and characterize these materials for applications that can take, in the tribological point of view since waste Polyester + fiberglass has great potential for replacement of CaCO3

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the incorporation of an industrial polymeric waste into a petroleum asphalt cement with penetration grade 50-60 (CAP 50-60). The main goal of this research is the development of a polymer-modified asphalt, with improvements in its physical properties, in order to obtain a more resistant material to the traffic loads. Furthermore, the use of this polymeric waste will result in economic and environmental benefits. The CAP 50-60 used in this research was kindly supplied by LUBNOR Lubrificantes e Derivados de Petróleo do Nordeste (produced in Fazenda Belém Aracati - Ceará) and the industrial polymeric waste was provided by a button manufacturer industry, located in Rio Grande do Norte state. This polymeric waste represents an environmental problem due to its difficulty in recycling and disposal, being necessary the payment by the industry to a landfill. The difficulty in its reuse is for being this material a termofixed polymer, as a result, the button chips resulting from the molding process cannot be employed for the same purpose. The first step in this research was the characterization of the polymeric waste, using Differential Scanning Calorimetry (DSC) Infrared spectroscopy (IR spectroscopy), and Thermogravimetric analysis (TGA). Based on the results, the material was classified as unsaturated polyester. After, laboratory experiments were accomplished seeking to incorporate the polymeric waste into the asphalt binder according to a 23 experimental factorial design, using as main factors: the polymer content (2%, 7% and 14%), the temperature of the mixture (140 and 180 oC) and the reaction time (20 and 60 minutes). The characterization of the polymer-modified asphalt was accomplished by traditional tests, such as: penetration, ring and ball softening point, viscosity, ductility and flash point temperature. The obtained results demonstrated that the addition of the polymeric waste into the asphalt binder modified some of its physical properties. However, this addition can be considered as a feasible alternative for the use of the polymeric waste, which is a serious environmental and technological problem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work is the addition of a metallic ion, of the metal Manganese, in a clay of Rio Grande do Norte state for structural ceramics use, the objective this study was to assess the evolution of ceramic properties. The clay was characterized by Chemical and Thermal analysis and Xray difraction. The metallic ion was added in the clay as aqueous solutions at concentrations of 100, 150 and 200 mg / L. The molded by extrusion and the burned were temperatures at 850, 950, 1050 and 1150 º C. Was made Chemical Analysis and investigated the following parameters environmental and ceramic: Solubility, Colour, Linear Retraction (%), Water Absorption (%), Gresification Curves, Apparent Porosity (%), Apparent Specific Mass (g/cm3) and Flexion Rupture Module (kgf/cm2). The results showed that increasing the concentration of metallic ion, properties such as Apparent Porosity (%), Water Absorption (%) decreases and the Flexion Rupture Module (kgf/cm2) increases with increasing temperature independent of the concentration of the ion. The gresification curves showed that the optimum firing temperatures were in the range between 950 and 1050 ° C. The evaluation of the properties showed that the ceramic material can be studied its use in solid brick and ceramic materials with structural function of filling. The results of solubility showed that the addition of ion offers no risk to the environment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A desinfecção de todo e qualquer molde obtido é medida de biossegurança obrigatória na atividade clínica. Tão importante quanto a desinfecção é a seleção do método e da solução desinfetante a ser utilizada para cada material de moldagem. É imperativo que a capacidade de reprodução de detalhes, a estabilidade dimensional e o grau de umedecimento (ou molhabilidade) não sejam criticamente afetados. O propósito deste trabalho foi avaliar o grau de umedecimento de uma marca comercial de poliéter (Impregum F) por três diferentes marcas comerciais de gesso tipo IV (Herostone, Durone e Polirock), após sua desinfecção por aerossóis de hipoclorito de sódio 1% (líquido de Milton) ou glutaraldeído 2% (Glutalabor II). Foram confeccionados 45 moldes de poliéter, os quais, em grupos de 15, receberam aerossóis de água (Grupo Controle), Líquido de Milton ou Glutalabor II. em seguida, sobre a superfície dos moldes foram confeccionados modelos de gesso tipo IV, em número de 5 para cada marca de gesso. Após seu seccionamento mediano e preparo da superfície de corte, os modelos foram levados ao microscópio Carl Zeiss para leitura do ângulo de contato. Os resultados obtidos permitiram concluir que: a) a capacidade de umedecimento do poliéter por diferentes marcas comerciais de gesso tipo IV variou para os gessos estudados; b) o gesso Durone adaptou-se melhor aos moldes de poliéter do que os gessos Herostone e Polirock; c) a desinfecção dos moldes com aerossóis de hipoclorito de sódio 1% (líquido de Milton) ou glutaraldeído 2% (Glutalabor) não afetou a adaptação entre os gessos e o poliéter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para o presente trabalho, 235 crianças pertencentes às creches da Prefeitura Municipal de Araraquara foram avaliadas e moldadas com um dispositivo confeccionado com cera utilidade e palito abaixador de língua na forma dos arcos dentários. No intervalo de um ano as mesmas crianças foram remoldadas afim de se verificar se houveram ou não mudanças nas dimensões do arco dentário decíduo. A partir da obtenção dos modelos em gesso, foram realizadas medições por meio de um dispositivo digitalizador tridimensional denominado MicroScribe-3DX nos instantes inicial (primeira moldagem) e final (moldagem após um ano). Foram avaliadas medidas referentes às distâncias inter-segundos molares, interprimeiros molares, intercaninos, perímetro, comprimento de arco e espaços primatas. Consideraram-se ainda dimorfismo sexual, tipo de arco e influência de hábitos. Concluiu-se que as dimensões transversais sofreram aumento significativo na dentadura decídua, enquanto que o perímetro, o comprimento e os espaços primatas permaneceram constantes. As distâncias intermolares apresentaram dimorfismo sexual, com dimensões maiores no gênero feminino. Com relação às medidas de perímetro, comprimento e espaços primatas não ocorreram diferenças significantes em relação ao gênero. As dimensões de comprimento nos arcos não diferem nos arcos decíduos Tipo I e Tipo II de Baume, enquanto que o diâmetro dos arcos Tipo I de Baume, são maiores do que os do Tipo II. Os hábitos de sucção de dedo e chupeta não provocaram alterações nas dimensões dos arcos decíduos no período observado, de um ano.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alginate or irreversible hydrocolloid is one the most accepted and frequently employed impression materials in dental practice. Substances like zinc, cadmium, lead silicate and fluorides, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern as regards their toxicity. Some brands of alginate have been reported to contain potentially toxic fluorides and metals such as cadmium, lead and zinc silicates, either singly or combined. Consequently, special care should be taken while preparing of these materials. It is necessary to monitor potentially toxic chemicals and metals in the alginates continually to avoid contamination of dental professionals and patients. In this review, alginates used in dentistry are analyzed for potential toxicity.