980 resultados para Modular electronics
Resumo:
Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.
Resumo:
This line of research of my group intends to establish a Silicon technological platform in the field of photonics allowing the development of a wide set of applications. Particularly, what is still lacking in Silicon Photonics is an efficient and integrable light source such an LED or laser. Nanocrystals in silicon oxide or nitride matrices have been recently demonstrated as competitive materials for both active components (electrically and optically driven light emitters and optical amplifiers) and passive ones (waveguides and modulators). The final goal is the achievement of a complete integration of electronic and optical functions in the same CMOS chip. The first part of this paper will introduce the structural and optical properties of LEDs fabricated from silicon nanostructures. The second will treat the interaction of such nanocrystals with rare-earth elements (Er), which lead to an efficient hybrid system emitting in the third window of optical fibers. I will present the fabrication and assessment of optical waveguide amplifiers at 1.54 ¿m for which we have been able to demonstrate recently optical gain in waveguides made from sputtered silicon suboxide materials.
Resumo:
Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.
Resumo:
O gerenciamento de informação pode ser identificado como desafio crucial, sobretudo no tocante aos conteúdos de websites e sistemas de informação em ambiente web. Assim, o desenvolvimento de meios e métodos para gerenciamento de conteúdos é tema deste artigo, o qual objetiva, através de um relato de aplicação de pesquisa participativa, apresentar a descrição funcional de um sistema modular para gerenciamento de conteúdos em ambiente web. São discutidos aspectos relacionados com o desenvolvimento do sistema e sua aplicação em 28 websites. Adicionalmente, é apresentada uma avaliação quantitativa com base na satisfação, facilidade de uso percebida, freqüência de uso e importância dos módulos que o compõem. Entre os principais resultados, aponta-se a evidência da flexibilidade da proposta modular e a constatação de que os gestores se mostraram satisfeitos com o sistema, não apresentando dificuldade de uso e obtendo resultados positivos com o uso da ferramenta.
Resumo:
This research, initiated in October 1992, was located at the intersection of Blairs Ferry Road and Lindale Drive in the City of Marion. The wall is located on the southeast corner of the intersection. Reinforced retaining wall construction started with a five inch base of roadstone with one inch of sand for leveling purposes. One and one-half to two feet of one inch clean stone was placed behind the blocks. A four inch perforated plastic pipe was placed approximately nine inches from the bottom of the one inch clean stone. The Tenswal, tensar geogrid was placed at every third layer. Openings in the Tenswal are hooked over plastic dowels in the blocks. The tenswal reaches from the face of the wall back 5' to 8'. The cost for constructing this wall was $124,400. The wall has performed well for the past five years. The wall improves the aesthetics of a high traffic volume intersection of an urban area. Many positive comments have been received by the city regarding its appearance. The City of Marion has been pleased with the wall and has used this type of wall on subsequent projects.
Resumo:
The focus of my PhD research was the concept of modularity. In the last 15 years, modularity has become a classic term in different fields of biology. On the conceptual level, a module is a set of interacting elements that remain mostly independent from the elements outside of the module. I used modular analysis techniques to study gene expression evolution in vertebrates. In particular, I identified ``natural'' modules of gene expression in mouse and human, and I showed that expression of organ-specific and system-specific genes tends to be conserved between such distance vertebrates as mammals and fishes. Also with a modular approach, I studied patterns of developmental constraints on transcriptome evolution. I showed that none of the two commonly accepted models of the evolution of embryonic development (``evo-devo'') are exclusively valid. In particular, I found that the conservation of the sequences of regulatory regions is highest during mid-development of zebrafish, and thus it supports the ``hourglass model''. In contrast, events of gene duplication and new gene introduction are most rare in early development, which supports the ``early conservation model''. In addition to the biological insights on transcriptome evolution, I have also discussed in detail the advantages of modular approaches in large-scale data analysis. Moreover, I re-analyzed several studies (published in high-ranking journals), and showed that their conclusions do not hold out under a detailed analysis. This demonstrates that complex analysis of high-throughput data requires a co-operation between biologists, bioinformaticians, and statisticians.
Resumo:
El proyecto consiste en la realización de una agenda web modular, utilizando para ello las tecnologías de la plataforma J2EE mediante frameworks (Hibernate y Spring) y un patrón de arquitectura (MVC). La agenda se ha realizado para ser gestionada por un servidor Apache Tomcat y sus datos almacenados en MySQL.
Resumo:
There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.
Resumo:
L'objectiu principal del TFC consisteix en la creació d'una complexa estructura modular J2EE basada i mantinguda per Maven, amb la utilització com frameworks Spring, Hibernate i Flex principalment. Aquesta estructura permet reprendre el desenvolupament inicial, nous desenvolupaments i manteniments d'una aplicació, amb un cost temporal mínim per la part de l'equip de desenvolupament.
Resumo:
En aquest treball presentem una proposta d’avaluació per competències en una estructura modular que és fruit de la nostra experiència com a professors universitaris. Volem oferir un instrument d’avaluació conjunta per a tot l’equip de professors de mòdul que sigui vàlid, àgil i operatiu i que permeti donar feedback a cada estudiant del seu procés d’aprenentatge. Després de presentar els trets més singulars de la nostra institució i exposar alguns referents teòrics en relació a l’avaluació de competències, indiquem quines són les competències que hem seleccionat i aprofundim en la metodologia de treball i avaluació de les mateixes. Aquesta metodologia varia segons els espais acadèmics: gran grup, grup mig i seminari. A cadascun d’aquests espais es treballen i s’avaluen unes competències determinades, tot i que d’una forma més genèrica totes es desenvolupen conjuntament ens els tres àmbits. Considerem que és fonamental assenyalar que no es tracta d’avaluar “per assignatures” ni “per activitats”, sinó d’avaluar les competències que es desenvolupen a través de les matèries i de les propostes de treball que s’especifiquen en el pla docent.. L’ instrument d’avaluació que presentem possibilita la participació de tot el professorat implicat en el mateix mòdul i alhora permet que cada professor utilitzi els seus propis indicadors d’avaluació, aconseguint harmonitzar les dinàmiques de treball individuals i de grup.
Resumo:
Tutkimuksen päätavoite on arvioida, ovatko neljä ohjelmistovaihtoehtoa riittäviä tuotannon aikataulutuksen työkaluja ja mikä työkaluista sopii toimeksiantajayritykselle. Alatavoitteena on kuvata tuotannon aikataulutuksen nyky- ja tahtotila prosessimallinnuksen avulla, selvittää työkalun käyttäjätarpeet ja määritellä priorisoidut valintakriteerit työkalulle.Tutkimuksen teoriaosuudessa tutkitaan tuotannon aikataulutuksen logiikkaa ja haasteita. Työssä tarkastellaan aikataulutusohjelmiston valintaa rinnakkain prosessinmallinnuksen kanssa. Aikataulutusohjelmistovaihtoehdot ja metodit käyttäjätarpeiden selvittämiseksi käydään läpi. Empiriaosuudessa selvitetään tutkimuksen suhde toimeksiantajayrityksen strategiaan. Käyttäjätarpeet selvitetään haastattelujen avulla jaanalysoidaan QFD matriisin avulla. Toimeksiantajayrityksen tuotannon aikataulutuksen nyky- ja tahtotilaprosessit mallinnetaan, jotta ohjelmistojen sopivuutta, aikataulutusprosessia tukevana työkaluna voidaan arvioida.Tutkimustuloksena ovatpriorisoidut valintakriteerit aikataulutustyökalulle eli käyttäjätarpeista johdetut tärkeimmät toiminnalliset ominaisuudet, järjestelmätoimittaja-arvio sekä suositukset jatkotoimenpiteistä ja lisätutkimuksesta.
Resumo:
Elektroniikka alalla tuotteet sisältävät yhä enemmän ja enemmän komponentteja joiden käyttöä yrityksen tulee hallita. Viime-aikaiset ympäristömääräykset ja lainsäädännöt ovat lisänneet yritysten painetta hallita käyttämiään komponentteja ja niiden tietoa tehokkaasti. Tässä työssä on tutkittu kolmen palveluntarjoajan tarjoamaa komponentinhallinta palvelua verrattunamahdolliseen talon omaan komponentti-insinööriin. Jotta tutkittuja vaihtoehtoja pystyisi vertailemaan, selvitettiin asiantuntija haastatteluja käyttäen komponenttien hallinnan erityispiirteet. Erityispiirteet yhdessä yrityksen vaatimuksien kanssa muodostivat kriteristön johon tutkittuja palveluja vertaillaan. Kriteeristö koostuu kahdeksasta osasta jotka puolestaan voidaan jaotella kolmeen ryhmään niiden keston ja luonteen mukaan. Neljän kriteerin katsottiin olevan tärkeämpiä kuin toiset, joten niille annettiin suurempi painoarvo palveluja vertailtaessa. Kaikki tutkitut palvelut täyttävät osan kriteereistä mutta mikään ei yksistään tarjoa riittävän kattavaa ratkaisua kohdeyrityksen ongelmiin. Suurimmat ongelmat yrityksellä ovat sisäisessä tiedonkulussa ja tietokantojen ja järjestelmien ylläpidossa ja hallinnassa. Jotta nämä ongelmat saataisiin ratkaistua on yrityksen saatava komponenttiprosessit toimimaan sekä tietokanta ajantasalle. Nämä tavoitteet saavutetaan vain jos yrityksessä on joku hoitamassa asiaa sisältä päin. Tutkitut kolme palvelua eivät tällaista sisäistä resurssia tarjoa vaan keskittyvät vain ulkoapäin tapahtuvaan tiedon välitykseen ja hallinnointiin.
Performance evaluation of the Roche Elecsys (R) CMV IgG and IgM on the modular analytics E170 : PX-5
Resumo:
Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.
Resumo:
L'expérience LHCb sera installée sur le futur accélérateur LHC du CERN. LHCb est un spectromètre à un bras consacré aux mesures de précision de la violation CP et à l'étude des désintégrations rares des particules qui contiennent un quark b. Actuellement LHCb se trouve dans la phase finale de recherche et développement et de conception. La construction a déjà commencé pour l'aimant et les calorimètres. Dans le Modèle Standard, la violation CP est causée par une phase complexe dans la matrice 3x3 CKM (Cabibbo-Kobayashi-Maskawa) de mélange des quarks. L'expérience LHCb compte utiliser les mesons B pour tester l'unitarité de cette matrice, en mesurant de diverses manières indépendantes tous les angles et côtés du "triangle d'unitarité". Cela permettra de surdéterminer le modèle et, peut-être, de mettre en évidence des incohérences qui seraient le signal de l'existence d'une physique au-delà du Modèle Standard. La reconstruction du vertex de désintégration des particules est une condition fondamentale pour l'expérience LHCb. La présence d'un vertex secondaire déplacé est une signature de la désintégration de particules avec un quark b. Cette signature est utilisée dans le trigger topologique du LHCb. Le Vertex Locator (VeLo) doit fournir des mesures précises de coordonnées de passage des traces près de la région d'interaction. Ces points sont ensuite utilisés pour reconstruire les trajectoires des particules et l'identification des vertices secondaires et la mesure des temps de vie des hadrons avec quark b. L'électronique du VeLo est une partie essentielle du système d'acquisition de données et doit se conformer aux spécifications de l'électronique de LHCb. La conception des circuits doit maximiser le rapport signal/bruit pour obtenir la meilleure performance de reconstruction des traces dans le détecteur. L'électronique, conçue en parallèle avec le développement du détecteur de silicium, a parcouru plusieurs phases de "prototyping" décrites dans cette thèse.<br/><br/>The LHCb experiment is being built at the future LHC accelerator at CERN. It is a forward single-arm spectrometer dedicated to precision measurements of CP violation and rare decays in the b quark sector. Presently it is finishing its R&D and final design stage. The construction already started for the magnet and calorimeters. In the Standard Model, CP violation arises via the complex phase of the 3 x 3 CKM (Cabibbo-Kobayashi-Maskawa) quark mixing matrix. The LHCb experiment will test the unitarity of this matrix by measuring in several theoretically unrelated ways all angles and sides of the so-called "unitary triangle". This will allow to over-constrain the model and - hopefully - to exhibit inconsistencies which will be a signal of physics beyond the Standard Model. The Vertex reconstruction is a fundamental requirement for the LHCb experiment. Displaced secondary vertices are a distinctive feature of b-hadron decays. This signature is used in the LHCb topology trigger. The Vertex Locator (VeLo) has to provide precise measurements of track coordinates close to the interaction region. These are used to reconstruct production and decay vertices of beauty-hadrons and to provide accurate measurements of their decay lifetimes. The Vertex Locator electronics is an essential part of the data acquisition system and must conform to the overall LHCb electronics specification. The design of the electronics must maximise the signal to noise ratio in order to achieve the best tracking reconstruction performance in the detector. The electronics is being designed in parallel with the silicon detector development and went trough several prototyping phases, which are described in this thesis.