961 resultados para Mirror scanner


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single photon Sagnac interferometry as a probe to macroscopic quantum mechanics is considered at the theoretical level. For a freely moving macroscopic quantum mirror susceptible to radiation pressure force inside a Sagnac interferometer, a careful analysis of the input-output relation reveals that the particle spectrum readout at the bright and dark ports encode information concerning the noncommutativity of position and momentum of the macroscopic mirror. A feasible experimental scheme to probe the commutation relation of a macroscopic quantum mirror is outlined to explore the possible frontier between classical and quantum regimes. In the Appendix, the case of Michelson interferometry as a feasible probe is also sketched.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With a latest developed electric-sweep scanner system, we have done a lot of experiments for studying this scanner system and ion beam emittance of electron cyclotron resonance (ECR) ion source. The electric-sweep scanner system was installed on the beam line of Lanzhou electron resonance ion source No. 3 experimental platform of Institute of Modem Physics. The repetition experiments have proven that the system is a relatively dependable and reliable emittance scanner, and its experiment error is about 10%. We have studied the influences of the major parameters of ECR ion source on the extracted ion beam emittance. The typical results of the experiments and the conclusions are presented in this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent experimental data have revealed large mirror energy differences (MED) between high-spin states in the mirror nuclei Se-67 and As-67, the heaviest pair where MED have been determined so far. The MED are generally attributed to the isospin symmetry breaking caused by the Coulomb force and by the isospin-nonconserving part of the nucleon-nucleon residual interaction. The different contributions of the various terms have been extensively studied in the fp shell. By employing large-scale shell-model calculations, we show that the inclusion of the g(9/2) orbit causes interference between the electromagnetic spin-orbit and the Coulomb monopole radial terms at high spin. The large MED are attributed to the aligned proton pair excitations from the p(3/2) and f(5/2) orbits to the g(9/2) orbit. The relation of the MED to deformation is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mirror nuclei N-12 and B-12 are separated by the Radioactive Ion Beam Line in Lanzhou (RIBLL) at HIRFL from the breakup of 78.6 MeV/u N-14 on a Be target. The total reaction cross-sections of N-12 at 34.9 MeV/u and B-12 at 54.4 MeV/u on a Si target have been measured by using the transmission method. Assuming N-12 consists of a C-11 core plus one halo proton, the excitation function of N-12 and B-12 on a Si target and a C target were calculated with the Glauber model. It can fit the experimental data very well. The characteristic halo structure for N-12 was found with a large diffusion of the protons density distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic definition of a cabaret is a café that offers live entertainment performed by singers, musicians and dancers and serves food and drink. It is generally housed in small, intimate spaces. Starting in the middle of the nineteenth century, artists, composers and writers met at Parisian cafés and salons to share their works. The cabaret was a suitable place for social activities. Artists could meet, discuss their opinions, and share their art in a relaxed setting. Even though cabaret music was often based on popular idioms, social and political commentary coupled with satirical settings represented the true soul of the genre. This trend flourished in the late nineteenth and early twentieth centuries. The first cabaret in Paris, Le Chat Noir inspired the growth of similar places in major cities throughout Europe besides Paris. The three recitals that comprise this dissertation project were performed at University of Maryland venues: the Robert & Arlene Kogod Theatre on 11 May 2011, Ulrich Recital Hall on 4 December 2011, and Gildenhorn Recital Hall on 4 March 2012. The repertoire for the first recital included works by Erik Satie with mezzo-soprano Monica Soto-Gil, Friedrich Hollaender with soprano Gabrielle DeMers, William Bolcom with baritone Ethan Watermeier and mezzo-soprano Stepanie Sadownik, and Poulenc with baritone Andrew McLaughlin. André Previn‘s Tango Song and Dance with violinist Jennifer Kim served as the instrumental interlude. The second recital included songs by Friedrich Hollaender with mezzo-soprano Monica Soto-Gil, Hanns Eisler and Viktor Ullmann with mezzo-soprano Stephanie Sadownik, and Mischa Spoliansky with soprano CarrieAnne Winter. Victor Hollaender‘s Romance and Albumblatt were the instrumental interludes with violinist Jennifer Kim. The last recital featured works for piano and violin, the Graceful Ghost Rag by William Bolcom with violinist Jenny Wu, Four Souvenirs by Paul Schoenfield with violinist Jennifer Kim, Cabaret Songs by Benjamin Britten with soprano Linda Mabbs, and Souvenirs for piano four-hands by Samuel Barber with pianist Rita Sloan. The recitals were recorded on compact discs and are archived within the Digital Repository at the University of Maryland (DRUM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the dynamics of a movable mirror in a Fabry-Perot cavity coupled through radiation pressure to the cavity field and in contact with a thermal bath at finite temperature. In contrast to previous approaches, we consider arbitrary values of the effective detuning between the cavity and an external input field. We analyse the radiation-pressure effect on the Brownian motion of the mirror and its significance in the density noise spectrum of the output cavity field. Important properties of the mirror dynamics can be gathered directly from this noise spectrum. The presented reconstruction provides an experimentally useful tool in the characterization of the energy and rigidity of the mirror as modified by the coupling with light. We also give a quantitative analysis of the recent experimental observation of self-cooling of a micromechanical oscillator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooling of mechanical resonators is currently a popular topic in many fields of physics including ultra-high precision measurements, detection of gravitational waves and the study of the transition between classical and quantum behaviour of a mechanical system. Here we report the observation of self-cooling of a micromirror by radiation pressure inside a high-finesse optical cavity. In essence, changes in intensity in a detuned cavity, as caused by the thermal vibration of the mirror, provide the mechanism for entropy flow from the mirror's oscillatory motion to the low-entropy cavity field. The crucial coupling between radiation and mechanical motion was made possible by producing free-standing micromirrors of low mass (m approximately 400 ng), high reflectance (more than 99.6%) and high mechanical quality (Q approximately 10,000). We observe cooling of the mechanical oscillator by a factor of more than 30; that is, from room temperature to below 10 K. In addition to purely photothermal effects we identify radiation pressure as a relevant mechanism responsible for the cooling. In contrast with earlier experiments, our technique does not need any active feedback. We expect that improvements of our method will permit cooling ratios beyond 1,000 and will thus possibly enable cooling all the way down to the quantum mechanical ground state of the micromirror.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acquisition of radiotherapy planning scans on positron emission tomography (PET)-CT scanners requires the involvement of radiotherapy radiographers. This study assessed the radiation dose received by these radiographers during this process. Radiotherapy planning F- fluorodeoxyglucose (F-FDG) PET-CT scans were acquired for 28 non-small cell lung cancer patients. In order to minimise the radiation dose received, a two-stage process was used in which the most time-consuming part of the set-up was performed before the patient received their F-FDG injection. Throughout this process, the radiographers wore electronic personal dosemeters and recorded the doses received at different stages of the process. The mean total radiation dose received by a radiotherapy radiographer was 5.1±2.6 mSv per patient. The use of the two-stage process reduced the time spent in close proximity to the patient by approximately a factor of four. The two-stage process was effective in keeping radiation dose to a minimum. The use of a pre-injection set-up session reduces the radiation dose to the radiotherapy radiographers because of their involvement in PET-CT radiotherapy treatment planning scans by approximately a factor of three.