994 resultados para Microwave Imaging Breast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a new approach to model and classify breast parenchymal tissue. Given a mammogram, first, we will discover the distribution of the different tissue densities in an unsupervised manner, and second, we will use this tissue distribution to perform the classification. We achieve this using a classifier based on local descriptors and probabilistic Latent Semantic Analysis (pLSA), a generative model from the statistical text literature. We studied the influence of different descriptors like texture and SIFT features at the classification stage showing that textons outperform SIFT in all cases. Moreover we demonstrate that pLSA automatically extracts meaningful latent aspects generating a compact tissue representation based on their densities, useful for discriminating on mammogram classification. We show the results of tissue classification over the MIAS and DDSM datasets. We compare our method with approaches that classified these same datasets showing a better performance of our proposal

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been shown that the accuracy of mammographic abnormality detection methods is strongly dependent on the breast tissue characteristics, where a dense breast drastically reduces detection sensitivity. In addition, breast tissue density is widely accepted to be an important risk indicator for the development of breast cancer. Here, we describe the development of an automatic breast tissue classification methodology, which can be summarized in a number of distinct steps: 1) the segmentation of the breast area into fatty versus dense mammographic tissue; 2) the extraction of morphological and texture features from the segmented breast areas; and 3) the use of a Bayesian combination of a number of classifiers. The evaluation, based on a large number of cases from two different mammographic data sets, shows a strong correlation ( and 0.67 for the two data sets) between automatic and expert-based Breast Imaging Reporting and Data System mammographic density assessment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A recent trend in digital mammography is computer-aided diagnosis systems, which are computerised tools designed to assist radiologists. Most of these systems are used for the automatic detection of abnormalities. However, recent studies have shown that their sensitivity is significantly decreased as the density of the breast increases. This dependence is method specific. In this paper we propose a new approach to the classification of mammographic images according to their breast parenchymal density. Our classification uses information extracted from segmentation results and is based on the underlying breast tissue texture. Classification performance was based on a large set of digitised mammograms. Evaluation involves different classifiers and uses a leave-one-out methodology. Results demonstrate the feasibility of estimating breast density using image processing and analysis techniques

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new approach to mammographic mass detection is presented in this paper. Although different algorithms have been proposed for such a task, most of them are application dependent. In contrast, our approach makes use of a kindred topic in computer vision adapted to our particular problem. In this sense, we translate the eigenfaces approach for face detection/classification problems to a mass detection. Two different databases were used to show the robustness of the approach. The first one consisted on a set of 160 regions of interest (RoIs) extracted from the MIAS database, being 40 of them with confirmed masses and the rest normal tissue. The second set of RoIs was extracted from the DDSM database, and contained 196 RoIs containing masses and 392 with normal, but suspicious regions. Initial results demonstrate the feasibility of using such approach with performances comparable to other algorithms, with the advantage of being a more general, simple and cost-effective approach

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ozone profiles from the Microwave Limb Sounder (MLS) onboard the Aura satellite of the NASA's Earth Observing System (EOS) were experimentally added to the European Centre for Medium-range Weather Forecasts (ECMWF) four-dimensional variational (4D-var) data assimilation system of version CY30R1, in which total ozone columns from Scanning Imaging Absorption Spectrometer for Atmospheric CHartographY (SCIAMACHY) onboard the Envisat satellite and partial profiles from the Solar Backscatter Ultraviolet (SBUV/2) instrument onboard the NOAA-16 satellite have been operationally assimilated. As shown by results for the autumn of 2005, additional constraints from MLS data significantly improved the agreement of the analyzed ozone fields with independent observations throughout most of the stratosphere, owing to the daily near-global coverage and good vertical resolution of MLS observations. The largest impacts were seen in the middle and lower stratosphere, where model deficiencies could not be effectively corrected by the operational observations without the additional information on the ozone vertical distribution provided by MLS. Even in the upper stratosphere, where ozone concentrations are mainly determined by rapid chemical processes, dense and vertically resolved MLS data helped reduce the biases related to model deficiencies. These improvements resulted in a more realistic and consistent description of spatial and temporal variations in stratospheric ozone, as demonstrated by cases in the dynamically and chemically active regions. However, combined assimilation of the often discrepant ozone observations might lead to underestimation of tropospheric ozone. In addition, model deficiencies induced large biases in the upper stratosphere in the medium-range (5-day) ozone forecasts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aluminium (Al) has been measured in human breast tissue, nipple aspirate fluid and breast cyst fluid, and recent studies have shown that at tissue concentrations, aluminium can induce DNA damage and suspension growth in human breast epithelial cells. This paper demonstrates for the first time that exposure to aluminium can also increase migratory and invasive properties of MCF-7 human breast cancer cells. Long-term (32 weeks) but not short-term (1 week) exposure of MCF-7 cells to 10-4M aluminium chloride or 10-4M aluminium chlorohydrate increased motility of the cells as measured by live cell imaging (cumulative length moved by individual cells), by a wound healing assay and by migration in real time through 8m pores of a membrane using xCELLigence technology. Long-term exposure (37weeks) to 10-4M aluminium chloride or 10-4M aluminium chlorohydrate also increased the ability of MCF-7 cells to invade through a matrigel layer as measured in real time using the xCELLigence system. Although molecular mechanisms remain to be characterized, the ability of aluminium salts to increase migratory and invasive properties of MCF-7 cells suggests that the presence of aluminium in the human breast could influence metastatic processes. This is important because mortality from breast cancer arises mainly from tumour spread rather than from the presence of a primary tumour in the breast.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aetiology of breast cancer is multifactorial. While there are known genetic predispositions to the disease it is probable that environmental factors are also involved. Recent research has demonstrated a regionally specific distribution of aluminium in breast tissue mastectomies while other work has suggested mechanisms whereby breast tissue aluminium might contribute towards the aetiology of breast cancer. We have looked to develop microwave digestion combined with a new form of graphite furnace atomic absorption spectrometry as a precise, accurate and reproducible method for the measurement of aluminium in breast tissue biopsies. We have used this method to test the thesis that there is a regional distribution of aluminium across the breast in women with breast cancer. Microwave digestion of whole breast tissue samples resulted in clear homogenous digests perfectly suitable for the determination of aluminium by graphite furnace atomic absorption spectrometry. The instrument detection limit for the method was 0.48 μg/L. Method blanks were used to estimate background levels of contamination of 14.80 μg/L. The mean concentration of aluminium across all tissues was 0.39 μg Al/g tissue dry wt. There were no statistically significant regionally specific differences in the content of aluminium. We have developed a robust method for the precise and accurate measurement of aluminium in human breast tissue. There are very few such data currently available in the scientific literature and they will add substantially to our understanding of any putative role of aluminium in breast cancer. While we did not observe any statistically significant differences in aluminium content across the breast it has to be emphasised that herein we measured whole breast tissue and not defatted tissue where such a distribution was previously noted. We are very confident that the method developed herein could now be used to provide accurate and reproducible data on the aluminium content in defatted tissue and oil from such tissues and thereby contribute towards our knowledge on aluminium and any role in breast cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In medical processes where ionizing radiation is used, dose planning and dose delivery are the key elements to patient safety and treatment success, particularly, when the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Therefore, the radiation dose should be well defined and precisely delivered to the target while minimizing radiation exposure to surrounding normal tissues [1]. Several methods have been proposed to obtain three-dimensional (3-D) dose distribution [2, 3]. In this paper, we propose an alternative method, which can be easily implemented in any stereotactic radiosurgery center with a magnetic resonance imaging (MRI) facility. A phantom with or without scattering centers filled with Fricke gel solution is irradiated with Gamma Knife(A (R)) system at a chosen spot. The phantom can be a replica of a human organ such as head, breast or any other organ. It can even be constructed from a real 3-D MR image of an organ of a patient using a computer-aided construction and irradiated at a specific region corresponding to the tumor position determined by MRI. The spin-lattice relaxation time T (1) of different parts of the irradiated phantom is determined by localized spectroscopy. The T (1)-weighted phantom images are used to correlate the image pixels intensity to the absorbed dose and consequently a 3-D dose distribution with a high resolution is obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scintimammography using Tc-99m-sestamibi is a noninvasive and painless diagnostic imaging method that is used to detect breast cancer when mammography is inconclusive Because of the advantages of labeling v '7,ith Tc-99m-sestamibi and its high efficiency in detecting carcinomas, it is the most widespread agent for this purpose Its accumulation in the tumor has multifactorial causes and does not depend on the presence of architectural distortion or local or diffuse density variation in the breast The objective of tfiis study was to evaluate the accuracy of scintimammography 1 for detecting breast cancer One hundred and fifty-seven patients presenting 158 palpable and non-palpable breast nodules were evaluated Three patients were male and 154 were female, aged between 14 and 81 years All patients underwent scintimammography, and the nodule was subjected i to cytological or histological study, i e, the gold standard for diagnosing cancer One hundred and eleven malignant and 47 benign nodules were detected, with predominance of ductal carcinomas (n=94) and fibroadenoma/fibrocysiic condition (n=11/n=11), respectively The mean size was 3 11 cm (7-10 cm) among the malignant nodules and 2 07 cm among the benign nodules (0 5-10 cm) The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 89, 89, 95, 78 and 89%, respectively Analysis on the histological types showed that the technique was more effective on tumors that were more aggressive, such as ductal carcinoma In this study, Tc-99m-sestamibi scintim immography was shown to be an important tool for diagnosing breast cancer when mammography was inconclusive

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to confirm the effectiveness of early physiotherapeutic stimulation for lymphatic flaw progression in patients with breast cancer undergoing axillary dissection This was a randomized experimental study oil 22 patients who underwent lymphoscintigraphy in their arms on two different occasions, firstly without stimulation and secondly after randomization into two groups without physiotherapeutic stimulation (WOPS, n=10) and with physiotherapeutic stimulation (WPS, n=12) The lymphoscintigraphy scan was performed with (99m)Tc-phytate administered into the second interdigital space of the hand, ipsilaterally to the dissected axilla, in three phases dynamic, static, and delayed whole body imaging Physiotherapeutic stimulation was earned out using Foldi's technique In both groups, images from the two examinations of each patient were compared Flow progression was considered positive when, on the second damnation, the radiopharmaceutical reached areas more distant from the injection site Statistical analysis was used to evaluate frequencies, percentages and central trend measurements, and non-parametric tests were conducted Descriptive analysis showed that the WPS and WOPS groups were similar M terms of mean age, weight, height, body mass index and number of lymph nodes removed There were statistically significant associations between physiotherapeutic stimulation and radiopharmaceutical progression at all three phases of the study (p < 0 0001) Early physiotherapeutic stimulation in beast cancer patients undergoing radical axillary dissection is effective, and can therefore be indicated as a preventive measure against lymphedema

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To describe the preoperative upper limb lymphoscintigraphic pattern in women with breast cancer. Methods: Thirty-seven patients undergoing lymphoscintigraphy within 30 days of surgery were investigated. Lymphoscintigraphic studies of 37 upper limbs ipsilateral to surgery and 32 contralateral upper limbs were performed. The examination protocol consisted in obtaining static images of the upper limb in semi-flexion after 10 minutes, and 1 and 2 hours after subcutaneous injection of 1 mCi (37 MBq) of Tc-99m-dextran in the dorsum of the hand. The velocity of axillary lymph node visualization (I, visible at 10 minutes; II, 1 hour; III, 2 hours; and IV, invisible) and degree (intensity) of nodal uptake (a, marked; b, moderate; c,mild; and d, absent) were analyzed. Results: Optimal lymphatic functional pattern (Ia) was observed in four (11%) patients, in the ipsilateral upper limb, and six (19%), in the contralateral upper limb. Worse condition was observed in three (8%) patients (IVd) in the ipsilateral upper limb and two (6%) patients in the contralateral upper limb. The remaining patients showed intermediate states of velocity and uptake intensity. Conclusion: This study found relevant changes in preoperative lymphoscintigraphy, demonstrating preexisting functional differences in the lymphatic system. © 2011 Elsevier Editora Ltda.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a mono-chromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we measured X-ray scatter spectra from normal and neoplastic breast tissues using photon energy of 17.44 key and a scattering angle of 90 degrees, in order to study the shape (FWHM) of the Compton peaks. The obtained results for FWHM were discussed in terms of composition and histological characteristics of each tissue type. The statistical analysis shows that the distribution of FWHM of normal adipose breast tissue clearly differs from all other investigated tissues. Comparison between experimental values of FWHM and effective atomic number revealed a strong correlation between them, showing that the FWHM values can be used to provide information about elemental composition of the tissues. (C) 2012 Elsevier Ltd. All rights reserved.