991 resultados para Manual labeling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate effects of different manual techniques on cervical ranges of 17 motion and pressure pain sensitivity in subjects with latent trigger point of the upper trapezius muscle. 18 Methods: One hundred seventeen volunteers, with a unilateral latent trigger point on upper trapezius due to computer 19 work, were randomly divided into 5 groups: ischemic compression (IC) group (n = 24); passive stretching group (n = 20 23); muscle energy technique group (n = 23); and 2 control groups, wait-and-see group (n = 25) and placebo group 21 (n = 22). Cervical spine range of movement was measured using a cervical range of motion instrument as well as 22 pressure pain sensitivity by means of an algometer and a visual analog scale. Outcomes were assessed pretreatment, 23 immediately, and 24 hours after the intervention and 1 week later by a blind researcher. A 4 × 5 mixed repeated- 24 measures analysis of variance was used to examine the effects of the intervention and Cohen d coefficient was used. 25 Results: A group-by-time interaction was detected in all variables (P b .01), except contralateral rotation. The 26 immediate effect sizes of the contralateral flexion, ipsilateral rotation, and pressure pain threshold were large for 3 27 experimental groups. Nevertheless, after 24 hours and 1 week, only IC group maintained the effect size. 28 Conclusions: Manual techniques on upper trapezius with latent trigger point seemed to improve the cervical range of 29 motion and the pressure pain sensitivity. These effects persist after 1 week in the IC group. (J Manipulative Physiol 301 Ther 2013;xx:1-10)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aquisição de competências ao nível da compreensão na leitura apresenta-se, cada vez mais, como o caminho para chegar ao conhecimento. O tipo de texto que se assume como o meio privilegiado de acesso ao conhecimento é o texto expositivo. Como tal, é importante que os textos a que os alunos têm acesso diariamente na sala de aula (nomeadamente, os textos dos manuais) sejam adequados ao desenvolvimento dessas competências. Neste estudo,analisaram-se os textos expositivos do manual de Estudo do Meio do 4.º ano mais adotado em Portugal no ano letivo 2010/2011. Em concreto, apurou-se a percentagem de textos expositivos existentes no manual, analisou-se a sua estrutura (Meyer, 1985), o tipo de questões que os acompanham, bem como as relações entre as perguntas e as respostas (Raphael, 1986, cit. em Giasson, 2000). O manual foi ainda analisado à luz do que é preconizado pelos documentos oficiais do Ministério da Educação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a possible design for a passive RFID tag antenna on paper substrate to be integrated into bottle labels. Considering the application scenario, we verified and determined the permittivity and dissipation factor of the materials in order to simulate all the possible sources that would influence the antenna performance. The measured results reported a maximum reading range of 1.45 m even though the efficiency obtained with the antenna integrated into the bottle was only of 3%. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A melhoria progressiva na prestação de cuidados de saúde que se verifica nos dias de hoje, deve-se maioritariamente ao desenvolvimento de novas tecnologias médicas, que se traduzem na criação de inovadores dispositivos médicos, cujo fim é auxiliar no diagnóstico, prevenção e tratamento de doenças, melhorando assim as condições de trabalho e os cuidados oferecidos aos pacientes. No entanto estas melhorias apenas são vantajosas quando as novas tecnologias são utilizadas de forma segura, o que leva a uma preocupação crescente com a segurança dos profissionais de saúde e dos pacientes em ambiente hospitalar. Como forma de reduzir e controlar os riscos existentes, as unidades de saúde introduziram mecanismos de gestão que permitem o conhecimento das fontes de risco e respetivos mecanismos de ação. A presente dissertação de mestrado apresenta uma proposta de modelo de Manual de Procedimentos para Gestão de Risco de Dispositivos Médicos, aplicável a todos os dispositivos médicos existentes nas Unidades de Saúde. Para a criação deste manual, foram utilizados por meio de adaptação, as etapas da gestão de risco definidas na Norma ISO 14971:2007 em conjunto com o método de gestão de risco utilizado pela Unidade Local de Saúde de Matosinhos O desenvolvimento deste manual de procedimentos permitirá a esta unidade de saúde, a aquisição e fornecimento de informações úteis na tomada de decisão sobre os procedimentos de controlo de risco de dispositivos médicos, com o objetivo de manter o risco destes dispositivos dentro dos níveis previamente estabelecidos e auxiliar a tomada de decisão de programas de manutenção preventiva e de aquisição de dispositivos médicos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. INTRODUÇÃO; 2. PROCEDIMENTOS DE ENTREGA DA DISSERTAÇÃO; 3. ESTRUTURA DA DISSERTAÇÃO; 4. FORMATAÇÃO; 5. CITAÇÕES; 6. CONCLUSÃO; BIBLIOGRAFIA; APÊNDICES

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compreender a funcionalidade de uma criança é um desafio persistente em contextos de saúde e educação. Na tentativa de superar esse desafio, em 2007, a Organização Mundial de Saúde desenvolveu a Classificação Internacional de Funcionalidade, Incapacidade e Saúde para Crianças e Jovens (CIF-CJ) como o primeiro sistema de classificação universal para documentar a saúde e funcionalidade da criança. Apesar de a CIF-CJ não ser um instrumento de avaliação e intervenção, tem, no entanto, a capacidade de servir de enquadramento para o desenvolvimento de ferramentas adaptadas às necessidades dos seus utilizadores. Considerando que no contexto escolar, a escrita manual encontra-se entre as atividades mais requeridas para a participação plena de uma criança, parece ser pertinente a definição de um conjunto de códigos destinados a caracterizar o perfil de funcionalidade de uma criança, no que se refere à escrita manual. O objetivo deste estudo foi, pois, o desenvolvimento de um conjunto preliminar de códigos baseado na CIF-CJ que possa vir a constituir um code set para a escrita manual. Dada a complexidade do tema e atendendo a que se pretende alcançar consenso entre os especialistas sobre quais as categorias da CIF-CJ que devem ser consideradas, optou-se pela utilização da técnica de Delphi. A escolha da metodologia seguiu a orientação dos procedimentos adotados pelo projeto Core Set CIF. De dezoito profissionais contactados, obtiveram-se respostas de sete terapeutas ocupacionais com experiência em pediatria, que participaram em todas as rondas. No total, três rondas de questionários foram realizadas para atingir um consenso, com um nível de concordância, previamente definido, de 70%. Deste estudo resultou um conjunto preliminar de códigos com 54 categorias da CIF-CJ (16 categorias de segundo nível, 14 categorias de terceiro nível e uma categoria de quarto nível), das quais 31 são categorias das funções do corpo, uma categoria das estruturas do corpo, 12 categorias de atividades e participação e 10 categorias de fatores ambientais. Este estudo é um primeiro passo para o desenvolvimento de um code set para a escrita manual baseado na CIF-CJ , sendo claramente necessário a realização de mais pesquisas no contexto do desenvolvimento e da validação deste code set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study describes a method for labeling Salmonella typhymurium with iodine-131 to evaluate both the morphological and the functional characteristics of the reticulo-endothelial system. A suspension containing 2 x 10(9) bacteria per ml was labeled with carrier-free Na131I without reductor, with a labeling yield of 46.5 ± 3% and 3.5 ± 1.3% of free Iodine-131. The biodistribution of the labeled bacteria in rats was studied with a large field-of-view scintillation camera equiped with a pinhole collimator. Whole body images were obtained 15 and 30 minutes after intravenous injection of the labeled microorganisms. Images showed accumulation of bacteria in the liver and both normal and transplanted spleens of the animals. Autoradiographs of liver and spleen demonstrated labeled bacteria within the cells of the reticulo-endothelial system. The method described is easy to perform, has a good labeling yield and allows the functional evaluation of the reticulo-monophagocytic system, including transplanted spleens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Ensino da Música.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: