997 resultados para Joints - Rangeof motion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: This study determined whether the visibility benefits of positioning retroreflective strips in biological motion configurations were evident at real world road worker sites. Methods: 20 visually normal drivers (M=40.3 years) participated in this study that was conducted at two road work sites (one suburban and one freeway) on two separate nights. At each site, four road workers walked in place wearing one of four different clothing options: a) standard road worker night vest, b) standard night vest plus retroreflective strips on thighs, c) standard night vest plus retroreflective strips on ankles and knees, d) standard night vest plus retroreflective strips on eight moveable joints (full biomotion). Participants seated in stationary vehicles at three different distances (80m, 160m, 240m) rated the relative conspicuity of the four road workers using a series of a standardized visibility and ranking scales. Results: Adding retroreflective strips in the full biomotion configuration to the standard night vest significantly (p<0.001) enhanced perceptions of road worker visibility compared to the standard vest alone, or in combination with thigh retroreflective markings. These visibility benefits were evident at all distances and at both sites. Retroreflective markings at the ankles and knees also provided visibility benefits compared to the standard vest, however, the full biomotion configuration was significantly better than all of the other configurations. Conclusions: These data provide the first evidence that the benefits of biomotion retroreflective markings that have been previously demonstrated under laboratory and closed- and open-road conditions are also evident at real work sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subtalar joint has been presumed to account for most of the pathologic motion in the foot and ankle, but research has shown that motion at other foot joints is greater than traditionally expected. Although recent research demonstrates the complexity of the kinematic variables in the foot and ankle, it still fails to expand our knowledge of the role of the musculotendinous structures in the biomechanics of the foot and ankle and how this is affected by in-shoe orthoses. The aim of this study was to simulate the effect of in-shoe foot orthoses by manipulation of the ground reaction force (GRF) components and centre of pressure (CoP) to demonstrate the resultant effect on muscle force in selected muscles during both the rearfoot loading response and stance phase of the gait cycle. We found that any medial wedge increases ankle joint load during gait cycle, while a lateral wedge decreases the joint load during the stance phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early-stage treatments for osteoarthritis are attracting considerable interest as a means to delay, or avoid altogether, the pain and lack of mobility associated with late-stage disease, and the considerable burden that it places on the community. With the development of these treatments comes a need to assess the tissue to which they are applied, both in trialling of new treatments and as an aid to clinical decision making. Here, we measure a range of mechanical indentation, ultrasound and near-infrared spectroscopy parameters in normal and osteoarthritic bovine joints in vitro to describe the role of different physical phenomena in disease progression, using this as a basis to investigate the potential value of the techniques as clinical tools. Based on 72 samples we found that mechanical and ultrasound parameters showed differences between fibrillated tissue, macroscopically normal tissue in osteoarthritic joints, and normal tissue, yet did were unable to differentiate degradation beyond that which was visible to the naked eye. Near-infrared spectroscopy showed a clear progression of degradation across the visibly normal osteoarthritic joint surface and as such, was the only technique considered useful for clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A priority when designing control strategies for autonomous underwater vehicles is to emphasize their cost of implementation on a real vehicle. Indeed, due to the vehicles' design and the actuation modes usually under consideration for underwater plateforms the number of actuator switchings must be kept to a small value to insure feasibility and precision. This is the main objective of the algorithm presented in this paper. The theory is illustrated on two examples, one is a fully actuated underwater vehicle capable of motion in six-degrees-of freedom and one is minimally actuated with control motions in the vertical plane only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A priority when designing control strategies for autonomous underwater vehicles is to emphasize their cost of implementation on a real vehicle and at the same time to minimize a prescribed criterion such as time, energy, payload or combination of those. Indeed, the major issue is that due to the vehicles' design and the actuation modes usually under consideration for underwater platforms the number of actuator switchings must be kept to a small value to ensure feasibility and precision. This constraint is typically not verified by optimal trajectories which might not even be piecewise constants. Our goal is to provide a feasible trajectory that minimizes the number of switchings while maintaining some qualities of the desired trajectory, such as optimality with respect to a given criterion. The one-sided Lipschitz constant is used to derive theoretical estimates. The theory is illustrated on two examples, one is a fully actuated underwater vehicle capable of motion in six degrees-of-freedom and one is minimally actuated with control motions constrained to the vertical plane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ratchetting failure of railhead material adjacent to endpost which is placed in the air gap between the two rail ends at insulated rail joints causes significant economic problems to the railway operators who rely on the proper functioning of these joints for train control using the signalling track circuitry. The ratchetting failure is a localised problem and is very difficult to predict even when complex analytical methods are employed. This paper presents a novel experimental technique that enables measurement of the progressive ratchetting. A special purpose test rig was developed for this purpose and commissioned by the Centre for Railway Engineering at Central Queensland University. The rig also provides the capability of testing of the wheel/rail rolling contract conditions. The results provide confidence that accurate measurement of the localised failure of railhead material can be achieved using the test rig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise offers the potential to improve circulation, wound healing outcomes, and functional and emotional wellbeing for adults experiencing venous leg ulceration. Individuals with chronic leg ulcers typically have multiple comorbidities such as arthritis, asthma, chronic obstructive airways disease, cardiac disease or neuromuscular disorders, which would also benefit from regular exercise. The aim of this review is to highlight the relationships between the calf muscle pump and venous return and range of ankle motion for adults with venous leg ulcers. The effect of exercise will also be considered in relation to the healing rates for adults experiencing venous leg ulceration. The findings suggest there is evidence that exercises which engage the calf muscle pump improve venous return. Ankle range of motion, which is crucial for complete activation of the calf muscle pump, can also be improved with simple, home-based exercise programs. However, observational studies still report that venous leg ulcer patients are less physically active than age-matched controls. Therefore, the behavioural reasons for not exercising must be considered. Only two studies, both underpowered, have assessed the effect of exercise on the healing rates of venous leg ulcers. In conclusion, exercise is feasible with this patient population. However, future studies with larger sample sizes are needed to provide stronger evidence to support the therapeutic benefit of exercise as an adjunct therapy in wound care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the basis of previous findings of an association between indices of driving safety and visual motion sensitivity and to examine whether this association could be explained by low-level changes in visual function. METHODS: 36 visually normal participants (aged 19 – 80 years), completed a battery of standard vision tests including visual acuity, contrast sensitivity and automated visual fields. and two tests of motion perception including sensitivity for movement of a drifting Gabor stimulus, and sensitivity for displacement in a random-dot kinematogram (Dmin). Participants also completed a hazard perception test (HPT) which measured participants’ response times to hazards embedded in video recordings of real world driving which has been shown to be linked to crash risk. RESULTS: Dmin for the random-dot stimulus ranged from -0.88 to -0.12 log minutes of arc, and the minimum drift rate for the Gabor stimulus ranged from 0.01 to 0.35 cycles per second. Both measures of motion sensitivity significantly predicted response times on the HPT. In addition, while the relationship involving the HPT and motion sensitivity for the random-dot kinematogram was partially explained by the other visual function measures, the relationship with sensitivity for detection of the drifting Gabor stimulus remained significant even after controlling for these variables. CONCLUSION: These findings suggest that motion perception plays an important role in the visual perception of driving-relevant hazards independent of other areas of visual function and should be further explored as a predictive test of driving safety. Future research should explore the causes of reduced motion perception in order to develop better interventions to improve road safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there is a paucity of scientific support for the benefits of warm-up, athletes commonly warm up prior to activity with the intention of improving performance and reducing the incidence of injuries. The purpose of this study was to examine the role of warm-up intensity on both range of motion (ROM) and anaerobic performance. Nine males (age = 21.7 +/- 1.6 years, height = 1.77 +/- 0.04 m, weight = 80.2 +/- 6.8 kg, and VO2max = 60.4 +/- 5.4 ml/kg/min) completed four trials. Each trial consisted of hip, knee, and ankle ROM evaluation using an electronic inclinometer and an anaerobic capacity test on the treadmill (time to fatigue at 13 km/hr and 20% grade). Subjects underwent no warm-up or a warm-up of 15 minutes running at 60, 70 or 80% VO2max followed by a series of lower limb stretches. Intensity of warm-up had little effect on ROM, since ankle dorsiflexion and hip extension significantly increased in all warm-up conditions, hip flexion significantly increased only after the 80% VO2max warm-up, and knee flexion did not change after any warm-up. Heart rate and body temperature were significantly increased (p < 0.05) prior to anaerobic performance for each of the warm-up conditions, but anaerobic performance improved significantly only after warm-up at 60% VO2max (10%) and 70% VO2max (13%). A 15-minute warm-up at an intensity of 60-70% VO2max is therefore recommended to improve ROM and enhance subsequent anaerobic performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In most visual mapping applications suited to Autonomous Underwater Vehicles (AUVs), stereo visual odometry (VO) is rarely utilised as a pose estimator as imagery is typically of very low framerate due to energy conservation and data storage requirements. This adversely affects the robustness of a vision-based pose estimator and its ability to generate a smooth trajectory. This paper presents a novel VO pipeline for low-overlap imagery from an AUV that utilises constrained motion and integrates magnetometer data in a bi-objective bundle adjustment stage to achieve low-drift pose estimates over large trajectories. We analyse the performance of a standard stereo VO algorithm and compare the results to the modified vo algorithm. Results are demonstrated in a virtual environment in addition to low-overlap imagery gathered from an AUV. The modified VO algorithm shows significantly improved pose accuracy and performance over trajectories of more than 300m. In addition, dense 3D meshes generated from the visual odometry pipeline are presented as a qualitative output of the solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The micro-circulation of blood plays an important role in human body by providing oxygen and nutrients to the cells and removing carbon dioxide and wastes from the cells. This process is greatly affected by the rheological properties of the Red Blood Cells (RBCs). Changes in the rheological properties of the RBCs are caused by certain human diseases such as malaria and sickle cell diseases. Therefore it is important to understand the motion and deformation mechanism of RBCs in order to diagnose and treat this kind of diseases. Although, many methods have been developed to explore the behavior of the RBCs in micro-channels, they could not explain the deformation mechanism of the RBCs properly. Recently developed Particle Methods are employed to explain the RBCs’ behavior in micro-channels more comprehensively. The main objective of this study is to critically analyze the present methods, used to model the RBC behavior in micro-channels, in order to develop a computationally efficient particle based model to describe the complete behavior of the RBCs in micro-channels accurately and comprehensively

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. For interactive systems, recognition, reproduction, and generalization of observed motion data are crucial for successful interaction. In this paper, we present a novel method for analysis of motion data that we refer to as K-OMM-trees. K-OMM-trees combine Ordered Means Models (OMMs) a model-based machine learning approach for time series with an hierarchical analysis technique for very large data sets, the K-tree algorithm. The proposed K-OMM-trees enable unsupervised prototype extraction of motion time series data with hierarchical data representation. After introducing the algorithmic details, we apply the proposed method to a gesture data set that includes substantial inter-class variations. Results from our studies show that K-OMM-trees are able to substantially increase the recognition performance and to learn an inherent data hierarchy with meaningful gesture abstractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This creative work is the outcome of preliminary experiments through practice aiming to explore the collaboration of a Dancer/choreographer with an Animator, along with enquiry into the intergeneration of motion capture technologies within the work-flow. The animated visuals derived from the motion capture data is not aimed at just re-targeting of movement from one source to another but looks at describing the thought and emotions of the choreographed dance through visual aesthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different types of HTS joints of Bi-2212/Ag tapes and laminates, which are fabricated by dip-coating and partial-melt processes, have been investigated. All joints are prepared using green single and laminated tapes and according to the scheme: coating-joining-processing. The heat treated tapes have critical current (Ic) between 7 and 27 A, depending on tape thickness and the number of Bi-2212 ceramic layers in laminated tapes. It is found that the current transport properties of joints depend on the type of laminate, joint configuration and joint treatment, Ic losses in joints of Bi-2212 tapes and laminates are attributed to defects in their structure, such as pores, secondary phases and misalignment of Bi-2212 grains near the Ag edges. By optimizing joint configuration, current transmission up to 100% is achieved for both single tapes and laminated tapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conspicuity limitations make bicycling at night dangerous. This experiment quantified bicyclists’ estimates of the distance at which approaching drivers would first recognize them. Twenty five participants (including 13 bicyclists who rode at least once per week, and 12 who rode once per month or less) cycled in place on a closed-road circuit at night-time and indicated when they were confident that an approaching driver would first recognize that a bicyclist was present. Participants wore black clothing alone or together with a fluorescent bicycling vest, a fluorescent bicycling vest with additional retroreflective tape, or the fluorescent retroreflective vest plus ankle and knee reflectors in a modified ‘biomotion’ configuration. The bicycle had a light mounted on the handlebars which was either static, flashing or off. Participants judged that black clothing made them least visible, retroreflective strips on the legs in addition to a retroreflective vest made them most visible and that adding retroreflective materials to a fluorescent vest provides no conspicuity benefits. Flashing bicycle lights were associated with higher conspicuity than static lights. Additionally, occasional bicyclists judged themselves to be more visible than did frequent bicyclists. Overall, bicyclists overestimated their conspicuity compared to previously collected recognition distances and underestimated the conspicuity benefits of retroreflective markings on their ankles and knees. Participants mistakenly judged that a fluorescent vest that did not include retroreflective material would enhance their night-time conspicuity. These findings suggest that bicyclists have dangerous misconceptions concerning the magnitude of the night-time conspicuity problem and the potential value of conspicuity treatments.