836 resultados para Interactive Device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

On assistive technology targeted for people with activity limitations and participation, usability issues becomes an essential tool to ensure that the product has the appropriate ergonomics characteristics, in other words, ensure that it fits the specific user´s needs. The aim of this study was to analyze the usability of an adaptive seating device for children with neuromotor impairments, by using kinematic indicators of the reaching movement. The study sample consisted of 13 children with associated neurologic conditions. The tests were developed by using a wooden bench height adjustable, integrated with the adaptive seating device under study, and a system to capture three-dimensional image, called Qualisys Track Manager. The following reaching kinematics variables were measured: maximum reaching velocity, movement duration, index of curvature, and unit movements. It was found that the use of the adaptive seating device had a positive impact on upper limb function in children with neuromotor impairments. It was also noticed an improvement in the reaching movement kinematics, which was statistical significant for the index of curvature and unit movements. As main conclusions, it is possible to point out some positive effects that the product under study seems to have on users' movements, such as the improved movement quality of the upper limb, which could mean a better postural adjustments and higher trunk postural control. By identifying new measures of usability in terms of effectiveness and efficiency for the analyzeddevice, the results obtained may serve also as performance indicators, providing new data that may help to improve the product and eventually modifying it, in order to turn it more compatible with the needs of the considered target population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing interest in thin and flexible energy storage devices to meet modern society needs for applications such as, radio frequency sensing, interactive packaging and other consumer products. Printed batteries comply these requirements and are an excellent alternative to conventional batteries for many applications. Flexible and micro-batteries are also included in the area of printed batteries whenever fabricated by printing technologies. The main characteristics, advantages, disadvantages, developments, and printing techniques of printed batteries are presented and discussed in this review. The state-of-art takes into account both the research and industrial levels. In the academic one, the research progress of printed batteries is summarized divided in lithium-ion battery (Li-ion), zinc-manganese dioxide (Zn-MnO2), and other battery types with emphasis on the different materials for anode, cathode and separator as well as in the battery design. With respect to the industrial state-of-art, materials, device formulations and manufacturing techniques are presented. Finally, the prospects and challenges of printed batteries are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flexible and low cost energy harvester device based on the magnetoelectric (ME) effect has been designed using Fe64Co17Si7B12 as amorphous magnetostrictive ribbons and PVDF as the piezoelectric element. Sandwich-type laminated composite of 3 cm long has been fabricated by gluing these ribbons to the PVDF with the Devcon 5 minute epoxy. Good power output and power density of 6.4 μW and 1.5 mW/cm3, respectively, have been obtained through a multiplier circuit. All values have been measured at the magnetomechanical resonance of the laminate. The effect of the length of the ME laminate on the power output has been also studied, exhibiting a decay as the length of the ME laminate does. Nevertheless, good performance of such device has been obtained for a 0.5 cm long device, working already at 337 KHz, within the low radio frequency (LRF) range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the problem of estimation maintenance costs for the case of the pitch controls system of wind farms turbines. Previous investigations have estimated these costs as (traditional) “crisp” values, simply ignoring the uncertainty nature of data and information available. This paper purposes an extended version of the estimation model by making use of the Fuzzy Set Theory. The results alert decision-makers to consequent uncertainty of the estimations along with their overall level, thus improving the information given to the mainte-nance support system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we present a 3D web-based interactive tool for numerical modeling and simulation approach to breast reduction surgery simulation, to assist surgeons in planning all aspects related to breast reduction surgery before the actual procedure takes place, thereby avoiding unnecessary risks. In particular, it allows the modeling of the initial breast geometry, the definition of all aspects related to the surgery and the visualization of the post-surgery breast shape in a realistic environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biopolymer-based materials have been of particular interest and they are alternatives to synthetic polymers based on the decreasing oil resources. The polymer electrolytes were doped with choline-based IL N,N,Ntrimethyl- N-(2-hydroxyethyl)ammonium bis(trifluoromethylsulfonyl)imide ([N1 1 1 2(OH)][NTf2]), or Er (CF3SO3)3 or both. The polymer electrolytes were employed in the production of glass/ITO/WO3/electrolyte/ CeO2–TiO2/ITO/glass electrochromic devices (ECDs). The lowest onset temperature for the degradation of all the SPEs is at ~130 °C for the Gellan Er (CF3SO3)3 (10:1) this temperature range of stability is wide enough for a material to be applied as an electrolyte/separator component in electrochemical devices. The three ECDs displayed fast switching speed (ca. 15 s). Gellan [N1 1 1 2(OH)][NTf2] Er (CF3SO3)3 (5:1:10) exhibited an electrochromic contrast of 4.2% in the visible region, the coloration efficiency attained at 555 nm was 3.5 and 0.90 cm-2 C-1 in the “colored” and “bleached” states, respectively, and the open circuit memorywas 48 h. Preliminary tests performed with a prototype electrochromic device (ECD) incorporating WO3 as cathodic electrochromic layer, are extremely encouraging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood typing is a crucial step before any blood transfusion. However, sometimes in emergency situations there is no time to determine the blood of the patient beforehand. In this cases, O negative blood type is administered, which has a lesser incompatibility risk to the patient. Nowadays, the “gold standard” blood typing devices cannot be used in emergency situations due to their high response time (about 30 minutes). This paper reports a blood typing device that determines the ABO and Rh human phenotypes. This device is fast (response time – 5 min), low-cost, and portable. Characteristics that make it suitable to be used in emergency situations, contributing to a higher efficiency and quality in healthcare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors acknowledge to Sofia Neves from ICVS for her help in the antibodies selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctoral Dissertation for PhD degree in Chemical and Biological Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In our work we have chosen to integrate formalism for knowledge representation with formalism for process representation as a way to specify and regulate the overall activity of a multi-cellular agent. The result of this approach is XP,N, another formalism, wherein a distributed system can be modeled as a collection of interrelated sub-nets sharing a common explicit control structure. Each sub-net represents a system of asynchronous concurrent threads modeled by a set of transitions. XP,N combines local state and control with interaction and hierarchy to achieve a high-level abstraction and to model the complex relationships between all the components of a distributed system. Viewed as a tool XP,N provides a carefully devised conflict resolution strategy that intentionally mimics the genetic regulatory mechanism used in an organic cell to select the next genes to process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device embolized to the distal pulmonary bed and, after being rescued with a Bitome, it was appropriately repositioned with no complications and with total occlusion of the vessel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the employment relationship on the basis of the notion of access. We argue that the degree of access provided by a job is an incentive to activate the employee’s self-actualization needs. We investigate the effect of access on the workers’ performance through an agency model and provide a number of propositions with practical implications for personnel policies. Our results are consistent with the intuition emerged from the real business practice as well as with many of the arguments on the substitutive role between monetary and non-monetary incentives frequently reported in the literature.