This paper proposes the use of battery energy storage (BES) system for the grid-connected doubly fed induction generator (DFIG). The BES would help in storing/releasing additional power in case of higher/lower wind speed to maintain constant grid power. The DC link capacitor is replaced with the BES system in a DFIG-based wind turbine to achieve the above-mentioned goal. The control scheme is modified and the co-ordinated tuning of the associated controllers to enhance the damping of the oscillatory modes is presented using bacterial foraging technique. The results from eigenvalue analysis and the time domain simulation studies are presented to elucidate the effectiveness of the BES systems in maintaining the grid stability under normal operation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Vehicle-to-Grid (V2G) concept is based on the newly developed and marketed technologies of hybrid petrol-electric vehicles, most notably represented by the Toyota Prius, in combination with significant structural changes to the world's energy economy, and the growing strain on electricity networks. The work described in this presentation focuses on the market and economic impacts of grid connected vehicles. We investigate price reduction effects and transmission system expansion cost reduction. We modelled a large numbers of plug-in-hybrid vehicle batteries by aggregating them into a virtual pumped-storage power station at the Australian national electricity market's (NEM) region level. The virtual power station concept models a centralised control for dispatching (operating) the aggregated electricity supply/demand capabilities of a large number of vehicles and their batteries. The actual level of output could be controlled by human or automated agents to either charge or discharge from/into the power grid. As previously mentioned the impacts of widespread deployments of this technology are likely to be economic, environmental and physical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grid connected photovoltaic (PV) inverters fall into three broad categories - central, string and module integrated converters (MICs). MICs offer many advantages in performance and flexibility, but are at a cost disadvantage. Two alternative novel approaches proposed by the author - cascaded dc-dc MICs and bypass dc-dc MICs - integrate a simple non-isolated intelligent dc-dc converter with each PV module to provide the advantages of dc-ac MICs at a lower cost. A suitable universal 150 W 5 A dc-dc converter design is presented based on two interleaved MOSFET half bridges. Testing shows zero voltage switching (ZVS) keeps losses under 1 W for bi-directional power flows up to 15 W between two adjacent 12 V PV modules for the bypass application, and efficiencies over 94% for most of the operational power range for the cascaded converter application. Based on the experimental results, potential optimizations to further reduce losses are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a distributed communication based active power curtailment (APC) control scheme for grid connected photovoltaic (PV) systems to address voltage rise. A simple distribution feeder model is presented and simulated using MATLAB. The resource sharing based control scheme proposed is shown to be effective at reducing voltage rise during times of peak generation and low load. Simulations also show the even distribution of APC using simple communications. Simulations demonstrate the versatility of the proposed control method under major communication failure conditions. Further research may lead to possible applications in coordinated electric vehicle (EV) charging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A robust and reliable grid power interface system for wind turbines using a permanent-magnet synchronous generator (PMSG) is proposed in this paper, where an integration of a generator-side three-switch buck-type rectifier and a grid-side Z-source inverter is employed as a bridge between the generator and the grid. The modulation strategy for the proposed topology is developed from space-vector modulation and Z-source network operation principles. Two PMSG control methods, namely, unity-power-factor control and rotor-flux-orientation control (Id = 0), are studied to establish an optimized control scheme for the generator-side three-switch buck-type rectifier. The system control scheme decouples active- and reactive-power control through voltage-oriented control and optimizes PMSG control for the grid- and generator-side converters independently. Maximum power point tracking is implemented by adjusting the shoot-through duty cycles of the Z-source network. The design considerations of the passive components are also provided. The performances and practicalities of the designed architecture have been verified by simulations and experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Matrix converter (MC) based bi-directional inductive power transfer (BD-IPT) systems are gaining popularity as an efficient and reliable technique with single stage grid integration as opposed to two stage grid integration of conventional grid connected BD-IPT systems. However MCs are invariably rich in harmonics and thus affect both power quality and power factor on the grid side. This paper proposes a mathematical model through which the grid side harmonics of MC based BD-IPT systems can accurately be estimated. The validity of the proposed mathematical model is verified using simulated results of a 3 kW BD-IPT system and results suggest that the MC based BD-IPT systems have a better power factor with higher power quality over conventional grid connected rectifier based systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A probabilistic method is proposed to evaluate voltage quality of grid-connected photovoltaic (PV) power systems. The random behavior of solar irradiation is described in statistical terms and the resulting voltage fluctuation probability distribution is then derived. Reactive power capabilities of the PV generators are then analyzed and their operation under constant power factor mode is examined. By utilizing the reactive power capability of the PV-generators to the full, it is shown that network voltage quality can be greatly enhanced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integrating Photovoltaic (PV) systems with battery energy storage in the distribution network will be essential to allow for continued uptake of domestic PV system installations. With increasing concerns regarding environmental and climate change issues, incorporating sources of renewable energy into power networks across the world will be key for a sustainable future. Australia is well placed to utilise solar energy as a significant component of its future energy generation and within the last 5 years there has been a rapid growth in the penetration levels seen by the grid. This growth of PV systems is causing a number of issues including intermittency of supply, negative power flow and voltage rises. Using the simulator tool GridLAB-D with a model of a typical South-East Queensland (SEQ) 11 kV distribution feeder, the effect of various configurations of PV systems have been offset with Battery Energy Storage Systems (BESS). From this, combinations of PV and storage that are most effective at mitigating the issues were explored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reviews the use of multi-agent systems to model the impacts of high levels of photovoltaic (PV) system penetration in distribution networks and presents some preliminary data obtained from the Perth Solar City high penetration PV trial. The Perth Solar City trial consists of a low voltage distribution feeder supplying 75 customers where 29 consumers have roof top photovoltaic systems. Data is collected from smart meters at each consumer premises, from data loggers at the transformer low voltage (LV) side and from a nearby distribution network SCADA measurement point on the high voltage side (HV) side of the transformer. The data will be used to progressively develop MAS models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Identical parallel-connected converters with unequal load sharing have unequal terminal voltages. The difference in terminal voltages is more pronounced in case of back-to-back connected converters, operated in power-circulation mode for the purpose of endurance tests. In this paper, a synchronous reference frame based analysis is presented to estimate the grid current distortion in interleaved, grid-connected converters with unequal terminal voltages. Influence of carrier interleaving angle on rms grid current ripple is studied theoretically as well as experimentally. Optimum interleaving angle to minimize the rms grid current ripple is investigated for different applications of parallel converters. The applications include unity power factor rectifiers, inverters for renewable energy sources, reactive power compensators, and circulating-power test set-up used for thermal testing of high-power converters. Optimum interleaving angle is shown to be a strong function of the average of the modulation indices of the two converters, irrespective of the application. The findings are verified experimentally on two parallel-connected converters, circulating reactive power of up to 150 kVA between them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nos últimos anos, o consumo de energia vem crescendo mundialmente nos grandes centros urbanos, e esforços na área de eficiência energética estão sendo implantados, a fim de reduzir o consumo no horário da ponta e interrupções da rede. O aproveitamento das fontes renováveis, como o fotovoltaico em uma edificação se torna um atrativo a mais para a matriz energética num momento em que o país prima pela universalização dos serviços de energia e a classificação de edifícios comerciais, de serviço e públicos, além dos residenciais quanto à eficiência energética através do Procel Edifica (RTQ-C e RTQ-R). Os sistemas fotovoltaicos podem configurar perfis de uso nas edificações de modo a gerar energia para consumo próprio ou ligado à rede e ainda ter influência na arquitetura do prédio com revestimento: os perfis podem está em telhados, fachadas ou janelas, amenizando em alguns casos a carga térmica no prédio com sombreamento arquitetônico. Hoje, com o avanço da tecnologia no setor de armazenagem é possível, o atendimento com segurança e eficiência a uma edificação ou direcionar esta armazenagem a uma demanda específica como o atendimento à demanda de ciclo profundo, tais como, iluminação externa e recarga de veículos elétricos. Partindo da premissa de sistemas interruptos de energia, UPS, uso de fonte secundária como FV, baterias e Flywheel é apresentado uma forma de melhor gerenciar a energia armazenada, podendo estender a vida útil da bateria e conseqüentemente de todo o sistema fotovoltaico na edificação. Esta forma de armazenar energia proporciona um serviço de uso contínuo sem percepção das interrupções da rede com garantia de 20 anos, tal qual o módulo fotovoltaico, com esta proposta as perdas de energia elétrica na edificação serão atenuadas, pois a eletricidade será utilizada de forma eficiente e inteligente. O ponto de partida do estudo de caso no prédio do IBAM são os sistemas fotovoltaicos com geração distribuída (mini-redes) conectados à rede que são instalados para fornecer energia ao consumidor, complementando a quantidade de energia demandada, caso haja algum aumento do consumo de energia na edificação, ou ainda utilizar o sistema fotovoltaico na hora da ponta e interrupções do sistema da rede no período fora da ponta. A estocagem inercial por meio do Flywheel tem um papel fundamental nesta mini-rede (Flywheel, bateria VRLA, UPS, inversor e STS), pois a sua utilização pode ser apontada como uma inovação tecnológica quanto à regulação de tensão no sistema de energia elétrica, além de preparar a edificação para o smart-grid. Esta configuração de acumulação de energia permitiu a analise do deslocamento desta energia armazenada para o consumo no horário de ponta, mudando o conceito de sistemas fotovoltaicos autônomos no meio urbano e rural no país. Este conceito de armazenagem se confirma então como um aporte na eficiência de energia na edificação, podendo carrear economia de energia substancial, além de proporcionar uma confiabilidade no serviço de energia, com um baixo retorno do investimento e com uma garantia de funcionamento com pequena ou nenhuma manutenção durante o período de vida de 20 anos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a new thermography-based maximum power point tracking (MPPT) scheme to address photovoltaic (PV) partial shading faults. Solar power generation utilizes a large number of PV cells connected in series and in parallel in an array, and that are physically distributed across a large field. When a PV module is faulted or partial shading occurs, the PV system sees a nonuniform distribution of generated electrical power and thermal profile, and the generation of multiple maximum power points (MPPs). If left untreated, this reduces the overall power generation and severe faults may propagate, resulting in damage to the system. In this paper, a thermal camera is employed for fault detection and a new MPPT scheme is developed to alter the operating point to match an optimized MPP. Extensive data mining is conducted on the images from the thermal camera in order to locate global MPPs. Based on this, a virtual MPPT is set out to find the global MPP. This can reduce MPPT time and be used to calculate the MPP reference voltage. Finally, the proposed methodology is experimentally implemented and validated by tests on a 600-W PV array. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the recent years, there has been a widespread trend in the use of the transformerless inverters in the single-phase grid-connected photovoltaic systems. This has been motivated by the low price, minor size, light mass, and great efficiency associated with them. However, when no transformer is used, common-mode voltage appears and leads to ground leakage current through the Photovoltaic parasitic capacitance to the ground due to the non-galvanic isolation configuration. This has lead to a main research focus on ways of minimizing or eliminating these leakage currents without influencing the efficiency of the system. Different topologies have been suggested to eliminate the leakage current in the transformerless grid-connected photovoltaic (PV) systems. In this paper, a review of these transformerless topologies is carried out, in regard to the leakage current for single phase. The benefits, in regard to each scheme, are outlined and their disadvantages explained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variable nature of the irradiance can produce significant fluctuations in the power generated by large grid-connected photovoltaic (PV) plants. Experimental 1 s data were collected throughout a year from six PV plants, 18 MWp in total. Then, the dependence of short (below 10 min) power fluctuation on PV plant size has been investigated. The analysis focuses on the study of fluctuation frequency as well as the maximum fluctuation value registered. An analytic model able to describe the frequency of a given fluctuation for a certain day is proposed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The power generated by large grid-connected photovoltaic (PV) plants depends greatly on the solar irradiance. This paper studies the effects of the solar irradiance variability analyzing experimental 1-s data collected throughout a year at six PV plants, totaling 18 MWp. Each PV plant was modeled as a first order filter function based on an analysis in the frequency domain of the irradiance data and the output power signals. An empiric expression which relates the filter parameters and the PV plant size has been proposed. This simple model has been successfully validated precisely determining the daily maximum output power fluctuation from incident irradiance measurements.