903 resultados para FEMORAL-SHAFT FRACTURES


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In postmenopausal women, yearly intravenous zoledronate (ZOL) compared to placebo (PLB) significantly increased bone mineral density (BMD) at lumbar spine (LS), femoral neck (FN), and total hip (TH) and decreased fracture risk. The effects of ZOL on BMD at the tibial epiphysis (T-EPI) and diaphysis (T-DIA) are unknown. METHODS A randomized controlled ancillary study of the HORIZON trial was conducted at the Department of Osteoporosis of the University Hospital of Berne, Switzerland. Women with ≥1 follow-up DXA measurement who had received ≥1 dose of either ZOL (n=55) or PLB (n=55) were included. BMD was measured at LS, FN, TH, T-EPI, and T-DIA at baseline, 6, 12, 24, and 36 months. Morphometric vertebral fractures were assessed. Incident clinical fractures were recorded as adverse events. RESULTS Baseline characteristics were comparable with those in HORIZON and between groups. After 36 months, BMD was significantly higher in women treated with ZOL vs. PLB at LS, FN, TH, and T-EPI (+7.6%, +3.7%, +5.6%, and +5.5%, respectively, p<0.01 for all) but not T-DIA (+1.1%). The number of patients with ≥1 incident non-vertebral or morphometric fracture did not differ between groups (9 ZOL/11 PLB). Mean changes in BMD did not differ between groups with and without incident fracture, except that women with an incident non-vertebral fracture had significantly higher bone loss at predominantly cortical T-DIA (p=0.005). CONCLUSION ZOL was significantly superior to PLB at T-EPI but not at T-DIA. Women with an incident non-vertebral fracture experienced bone loss at T-DIA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fractures of the growing bone require fixation techniques, which preclude any injury to the growth plate regions. This requirement is met by Elastic Stable Intramedullary Nails (ESIN) which are positioned between both metaphyseal regions. Pronounced malposition and/or shortening, open fractures and fractures with impending skin perforation are indications for clavicle nailing in adolescents. Retrograde nailing with two elastic nails, inserted from lateral, is the method of choice for stabilization of humerus fractures. In radial neck fractures with severe tilting of the radial head, a retrograde nail may reduce and fix the head. In Monteggia lesions, the ulna fracture is reduced and fixed with an antegrade nail. Forearm fractures with unacceptable axial deviation are reduced and fixed with one antegrade nail in the ulna and a retrograde nail in the radius. Ascending elastic nailing is done for femur shaft and proximal femur fractures. The medial and lateral entry sites are located above the distal physis. End caps are used to prevent shortening in spiral and multiple segment fractures. Fractures of the distal third of the femur are nailed in a descending technique. The entry sites of two nails are located on the lateral cortex below the greater trochanter. Combined tibia and fibula fractures, open fractures and unstable fracture types such as spiral and multifragmental tibia fractures are good indications for ESIN. Descending nailing is the method of choice. The nail entry points are medially and laterally distal to the apophysis of the proximal tibia. Thorough knowledge of each fracture type, fracture location and age specific healing pattern is necessary for safe and effective treatment of pediatric fractures

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The majority of people who sustain hip fractures after a fall to the side would not have been identified using current screening techniques such as areal bone mineral density. Identifying them, however, is essential so that appropriate pharmacological or lifestyle interventions can be implemented. A protocol, demonstrated on a single specimen, is introduced, comprising the following components; in vitro biofidelic drop tower testing of a proximal femur; high-speed image analysis through digital image correlation; detailed accounting of the energy present during the drop tower test; organ level finite element simulations of the drop tower test; micro level finite element simulations of critical volumes of interest in the trabecular bone. Fracture in the femoral specimen initiated in the superior part of the neck. Measured fracture load was 3760 N, compared to 4871 N predicted based on the finite element analysis. Digital image correlation showed compressive surface strains as high as 7.1% prior to fracture. Voxel level results were consistent with high-speed video data and helped identify hidden local structural weaknesses. We found using a drop tower test protocol that a femoral neck fracture can be created with a fall velocity and energy representative of a sideways fall from standing. Additionally, we found that the nested explicit finite element method used allowed us to identify local structural weaknesses associated with femur fracture initiation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabecular bone plays an important mechanical role in bone fractures and implant stability. Homogenized nonlinear finite element (FE) analysis of whole bones can deliver improved fracture risk and implant loosening assessment. Such simulations require the knowledge of mechanical properties such as an appropriate yield behavior and criterion for trabecular bone. Identification of a complete yield surface is extremely difficult experimentally but can be achieved in silico by using micro-FE analysis on cubical trabecular volume elements. Nevertheless, the influence of the boundary conditions (BCs), which are applied to such volume elements, on the obtained yield properties remains unknown. Therefore, this study compared homogenized yield properties along 17 load cases of 126 human femoral trabecular cubic specimens computed with classical kinematic uniform BCs (KUBCs) and a new set of mixed uniform BCs, namely periodicity-compatible mixed uniform BCs (PMUBCs). In stress space, PMUBCs lead to 7–72 % lower yield stresses compared to KUBCs. The yield surfaces obtained with both KUBCs and PMUBCs demonstrate a pressure-sensitive ellipsoidal shape. A volume fraction and fabric-based quadric yield function successfully fitted the yield surfaces of both BCs with a correlation coefficient R2≥0.93. As expected, yield strains show only a weak dependency on bone volume fraction and fabric. The role of the two BCs in homogenized FE analysis of whole bones will need to be investigated and validated with experimental results at the whole bone level in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rebound-associated vertebral fractures may follow treatment discontinuation of highly potent reversible bone antiresorptives, resulting from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone. INTRODUCTION The purposes of this study are to characterize rebound-associated vertebral fractures following the discontinuation of a highly potent reversible antiresorptive therapy based on clinical observation and propose a pathophysiological rationale. METHODS This study is a case report of multiple vertebral fractures early after discontinuation of denosumab therapy in a patient with hormone receptor-positive non-metastatic breast cancer treated with an aromatase inhibitor. RESULTS Discontinuation of highly potent reversible bone antiresorptives such as denosumab may expose patients to an increased fracture risk due to the joined effects of absent microdamage repair during therapy followed by synchronous excess activation of multiple bone remodelling units at the time of loss-of-effect. We suggest the term rebound-associated vertebral fractures (RVF) for this phenomenon characterized by the presence of multiple new clinical vertebral fractures, associated with either no or low trauma, in a context consistent with the presence of high bone turnover and rapid loss of lumbar spine bone mineral density (BMD) occurring within 3 to 12 months after discontinuation (loss-of-effect) of a reversible antiresorptive therapy in the absence of secondary causes of bone loss or fractures. Unlike atypical femoral fractures that emerge from failure of microdamage repair in cortical bone with long-term antiresorptive treatment, RVF originate from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone triggered by the discontinuation of highly potent reversible antiresorptives. CONCLUSIONS Studies are urgently needed to i) prove the underlying pathophysiological processes suggested above, ii) establish the predictive criteria exposing patients to an increased risk of RVF, and iii) determine appropriate treatment regimens to be applied in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with other fixation methods in mandibular symphysis fractures. Ten polyurethane mandibles were allocated to each group and fixed as follows: group PRP, 2 perpendicular miniplates; group PLL, 1 miniplate and 1 plate, parallel; and group CS, 2 cannulated screws. Vertical linear loading tests were performed. The differences between mean values were analyzed with the Tukey test. The photoelastic test was carried out using a polariscope. The results revealed differences between the CS and PRP groups at 1, 3, 5, and 10 millimeters of displacement. The photoelastic test confirmed higher stress concentration in all groups close to the mandibular base, whereas the CS group showed it throughout the region assessed. Conical cannulated screws performed well in mechanical and photoelastic tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to compare four methods of fixation in mandibular body fractures. Mechanical and photoelastic tests were performed using polyurethane and photoelastic resin mandibles, respectively. The study groups contained the following: (I), two miniplates of 2.0 mm; (II) one 2.0 mm plate and an Erich arch bar; (III) one 2.4 mm plate and an Erich arch bar, and (IV) one 2.0 mm plate and one 2.4 mm plate. The differences between the mean values were analyzed using Tukey's test, the Mann-Whitney test and the Bonferroni correction. Group II recorded the lowest resistance, followed by groups I, IV and III. The photoelastic test confirmed the increase of tension in group II. The 2.4 mm system board in linear mandibular body fractures provided more resistance and the use of only one 2.0 mm plate in the central area of the mandible created higher tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Evaluate the bone tissue recovery following transplantation of ovine mesenchymal stem cells (MSC) from bone marrow and human immature dental-pulp stem cells (hIDPSC) in ovine model of induced osteonecrosis of femoral head (ONFH). METHODS: Eight sheep were divided in three experimental groups. First group was composed by four animals with ONFH induced by ethanol through central decompression (CD), for control group without any treatment. The second and third group were compose by two animals, six weeks after ONFH induction received transplantation of heterologous ovine MSC (CD + oMSC), and hIDPSC (CD + hIDPSC), respectively. In both experiments the cells were transplanted without application of any type of immunosupression protocol. RESULTS: Our data indicate that both cell types used in experiments were able to proliferate within injured site providing bone tissue recovery. The histological results obtained from CD+hIDPSC suggested that the bone regeneration in such animals was better than that observed in CD animals. CONCLUSION: Mesenchymal stem cell transplant in induced ovine osteonecrosis of femoral head by central decompression technique is safe, and apparently favors bone regeneration of damaged tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na tentativa de evitar algumas das dificuldades associadas à osteotomia pélvica tripla (OPT), foi desenvolvido experimentalmente o método de aplicação de cunha na junção sacroilíaca para aumentar a ventroversão acetabular. O objetivo deste estudo foi aplicar as técnicas de cunha sacroilíaca e OPT em cadáveres e avaliar radiograficamente a eficácia da ventroversão acetabular. Para tal, foram utilizados 10 cadáveres de cães, adultos, com 15-25 kg. Em cada hemipelve direita foi realizada OPT com placas de 20° e 40°. Na hemipelve esquerda foram aplicadas cunhas nas articulações sacroilíacas de 20° e 40°. Avaliações radiográficas em projeções ventrodorsais foram realizadas para mensuração da cobertura acetabular à cabeça femoral nas duas técnicas. De acordo com os dados obtidos pode-se observar que não houve diferença entre a técnica de OPT e o uso de cunha sacroilíaca utilizando implantes de 20° e 40°, mas ocorreu diferença significativa (p<0,05) entre os cães antes e após a aplicação dos implantes de 20° e 40°, e também entre os que receberam implantes de 20° e os de 40°. A aplicação de cunha sacroilíaca produziu resultados semelhantes à OPT, e também se mostrou como de mais fácil aplicação.