788 resultados para Endoprothèse (stent)
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
Drug eluting stent (DES) restenosis has emerged as a significant clinical entity owing to the increasing use of DES in complex lesions and patients. However, to date, there is a paucity of studies that have addressed the management of DES restenosis and the resulting outcome, leaving the interventional cardiologist with a therapeutic dilemma. The purpose of this paper is therefore to provide a concise review of available data's dealing with the treatment of DES restenosis, including the outcome of patients treated for DES restenosis, the prognostic importance of the angiographic pattern and the available therapeutic modalities.
Resumo:
This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n = 7), pancreatic adenocarcinoma (n = 4), or another cancer (n = 3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n = 9), ascites (n = 7), and/or thrombocytopenia (n = 2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean +/- standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2 mmHg +/- 4.6 to 1.1 mmHg +/- 1.0 (P < 0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean +/- SD follow-up of 134.4 +/- 123.3 days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97 +/- 71.2 days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7 +/- 153.5 days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single session.
Resumo:
BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
AIM: To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). METHODS AND RESULTS: Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). CONCLUSION: A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957).
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
Rapport de synthèse : But: la resténose intra-stent au sirolimus (SAS) reste un problème clinique. Parmi tes diverses approches thérapeutiques disponibles aujourd'hui aucune n'a la primauté car tes résultats à moyen terme restent relativement médiocres. Méthodologie: les patients souffrant d'une resténose intra-SAS chez lesquels un second SAS a été implanté comme traitement de cette resténose ont été inclus dans ce registre. Lors d'ischémie clinique ou électrique après implantation d'un SAS les malades chez lesquels l'angioplastie au ballon seul ne donnait pas un résultat satisfaisant ont bénéficié de l'implantation d'un stent actif dans un stent actif. Résultats: vingt-sept patients sont inclus dans ce registre. La resténose était de type focale dans 34% des cas, diffuse dans 59% des cas et proliférative dans 7% des cas. La procédure a été un succès chez tous les patients sans complications aiguës durant l'hospitalisation. A 14±7 mois, on dénombre 8 (30%) événements cardiaques majeurs (1 mort, 1 infarctus du myocarde, 4 revascularisations additionnelles de la lésion, 1 revascularisation additionnelle du vaisseau cible). Un patient a subi un pontage aorto-coronarien. Dix-neuf patients (70%) ont évolué sans aucun problème. Conclusion: en conclusion, l'implantation d'un SAS pour traiter une resténose intra-SAS est réalisable avec un très bon résultat immédiat. Cependant, l'incidence d'un événement cardiaque majeur reste élevée à long terme.
Resumo:
Aim: The aim of this study was to assess the effect of iStent (trabecular micro-bypass stent) implantation in combination with phacoemulsification on IOP and glaucoma medications and to compare this to the outcome of phacoemulsification alone. Patients and Methods: A retrospective consecutive comparative review was undertaken. 131 eyes with ocular hypertension and medically controlled glaucoma underwent phacoemulsification alone (n = 78 group I) or combined with gonioscopic-guided implantation of one iStent (n = 31, group II) or two iStents (n = 22, group III). Patients were assessed at postoperative weeks 1, 3 and 6, and months 3 and 6. Pre- and post-operative measures included visual acuity, IOP and glaucoma medications. Results: Post-operatively at 6 months, mean IOP decreased from 16.3 mmHg to 14.2 mmHg in group I (p < 0.01), from 16.7 mmHg to 15.1 mmHg in group II (p < 0.16) and from 17.0 to 13.8 in group III (p = 0.05). Mean glaucoma medication decreased from 1.9 to 1.6 in group I (8 %, p = 0.12), from 2.5 to 0.8 in group II (27 %, p = 0.04), and from 2.1 to 1.0 in group III (45 %, p < 0.01). Conclusions: iStent implantation resulted in similar IOP reduction to phacoemulsification alone but achieved a significantly greater reduction in glaucoma medications. This may improve compliance and quality of life, and reduce health care costs in patients with early to moderate glaucoma.
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
OBJETIVOS: Descrever o uso do "shunt" intra-hepático portossistêmico (TIPS) e do "stent" venoso supra-hepático no manejo da síndrome de Budd-Chiari, enfocando suas indicações, aspectos técnicos e benefícios do procedimento. MATERIAIS E MÉTODOS: De janeiro de 1999 a março de 2002, nove casos de síndrome de Budd-Chiari foram encaminhados ao Serviço de Hemodinâmica do Hospital São Lucas, Porto Alegre, RS. A obstrução venosa supra-hepática foi constatada em todos os casos por meio de ultra-sonografia com Doppler em cores. A criação de TIPS foi realizada entre o sistema venoso supra-hepático ou a veia cava inferior e a veia porta, posicionando-se a endoprótese entre as duas abordagens. Doppler em cores pós-procedimento foi efetuado em todos os pacientes em períodos seriados. RESULTADOS: Três casos foram tratados inicialmente com inserção de "stent" venoso por apresentarem estenose preponderante em veias supra-hepáticas. Em dois desses casos ocorreu trombose do "stent", sendo necessária colocação de TIPS. Os demais seis casos foram tratados primariamente com TIPS. Dos oito "shunts" criados, trombose da endoprótese foi constatada em três casos, resolvidas com limpeza dos trombos e dilatação com balão em um caso e inserção de novas próteses nos demais. Embolização com molas de colaterais venosas ectasiadas foi efetuada em um paciente. CONCLUSÕES: A colocação de TIPS constitui-se numa estratégia terapêutica segura e efetiva na síndrome de Budd-Chiari, promovendo uma significativa melhora clínica e hemodinâmica dos pacientes, evitando procedimentos mais invasivos e podendo, em casos sem cirrose estabelecida, servir de tratamento definitivo da hipertensão portal.
Resumo:
This report describes a solution for a restenosis and for the fracture of a stent in the vertebral artery in a patient suffering from vertebrobasilar symptoms. Angiography demonstrates restenosis of a vertebral stent as well as its fracture and migration into the subclavian artery. This complication was managed percutaneously by passing a guide wire through the fractured stent. Pre-dilatation and kissing balloon techniques were applied in both the vertebral and subclavian arteries to modify the stent's dimensions and shape it into the form of a "ring." Postprocedural angiography demonstrated an excellent final result with the assistance of StentBoost visualization. Control angiography at six months also utilized StentBoost imaging and confirmed the patency of the bifurcation and that the stent was not displaced.