961 resultados para Electromyographic signal acquisition


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has long been supposed that the interference observed in certain patterns of coordination is mediated, at least in part, by peripheral afference from the moving limbs. We manipulated the level of afferent input, arising from movement of the opposite limb, during the acquisition of a complex coordination task. Participants learned to generate flexion and extension movements of the right wrist, of 75degrees amplitude, that were a quarter cycle out of phase with a 1-Hz sinusoidal visual reference signal. On separate trials, the left wrist either was at rest, or was moved passively by a torque motor through 50degrees, 75degrees or 100degrees, in synchrony with the reference signal. Five acquisition sessions were conducted on successive days. A retention session was conducted I week later. Performance was initially superior when the opposite limb was moved passively than when it was static. The amplitude and frequency of active movement were lower in the static condition than in the driven conditions and the variation in the relative phase relation across trials was greater than in the driven conditions. In addition, the variability of amplitude, frequency and the relative phase relation during each trial was greater when the opposite limb was static than when driven. Similar effects were expressed in electromyograms. The most marked and consistent differences in the accuracy and consistency of performance (defined in terms of relative phase) were between the static condition and the condition in which the left wrist was moved through 50degrees. These outcomes were exhibited most prominently during initial exposure to the task. Increases in task performance during the acquisition period, as assessed by a number of kinematic variables, were generally well described by power functions. In addition, the recruitment of extensor carpi radialis (ECR), and the degree of co-contraction of flexor carpi radialis and ECR, decreased during acquisition. Our results indicate that, in an appropriate task context, afferent feedback from the opposite limb, even when out of phase with the focal movement, may have a positive influence upon the stability of coordination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a wireless EEG acquisition platform based on Open Multimedia Architecture Platform (OMAP) embedded system. A high-impedance active dry electrode was tested for improving the scalp- electrode interface. It was used the sigma-delta ADS1298 analog-to-digital converter, and developed a “kernelspace” character driver to manage the communications between the converter unit and the OMAP’s ARM core. The acquired EEG signal data is processed by a “userspace” application, which accesses the driver’s memory, saves the data to a SD-card and transmits them through a wireless TCP/IP-socket to a PC. The electrodes were tested through the alpha wave replacement phenomenon. The experimental results presented the expected alpha rhythm (8-13 Hz) reactiveness to the eyes opening task. The driver spends about 725 μs to acquire and store the data samples. The application takes about 244 μs to get the data from the driver and 1.4 ms to save it in the SD-card. A WiFi throughput of 12.8Mbps was measured which results in a transmission time of 5 ms for 512 kb of data. The embedded system consumes about 200 mAh when wireless off and 400 mAh when it is on. The system exhibits a reliable performance to record EEG signals and transmit them wirelessly. Besides the microcontroller-based architectures, the proposed platform demonstrates that powerful ARM processors running embedded operating systems can be programmed with real-time constrains at the kernel level in order to control hardware, while maintaining their parallel processing abilities in high level software applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Myocardial perfusion-gated-SPECT (MP-gated-SPECT) imaging often shows radiotracer uptake in abdominal organs. This accumulation interferes frequently with qualitative and quantitative assessment of the infero-septal region of myocardium. The objective of this study is to evaluate the effect of ingestion of different fat content on the reduction of extra-myocardial uptake and to improve MP-gated-SPECT image quality. In this study, 150 patients (65 ^ 18 years) who were referred for MP-gated-SPECT underwent a 1-day-protocol including imaging after stress (physical or pharmacological) and resting conditions. All patients gave written informed consent. Patients were subdivided into five groups: GI, GII, GIII, GIV and GV. In the first four groups, patients ate two chocolate bars with different fat content. Patients in GV – control group (CG) – had just water. Uptake indices (UI) of myocardium (M)/liver(L) and M/stomach–proximal bowel(S) revealed lower UI of M/S at rest in all groups. Both stress and rest studies using different food intake indicate that patients who ate chocolate with different fat content showed better UI of M/L than the CG. The UI of M/L and M/S of groups obtained under physical stress are clearly superior to that of groups obtained under pharmacological stress. These differences are only significant in patients who ate high-fat chocolate or drank water. The analysis of all stress studies together (GI, GII, GIII and GIV) in comparison with CG shows higher mean ranks of UI of M/L for those who ate high-fat chocolate. After pharmacological stress, the mean ranks of UI of M/L were higher for patients who ate high- and low-fat chocolate. In conclusion, eating food with fat content after radiotracer injection increases, respectively, the UI of M/L after stress and rest in MP-gated-SPECT studies. It is, therefore, recommended that patients eat a chocolate bar after radiotracer injection and before image acquisition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-expanded echolocation calls were recorded from 29 species of Neotropical bats in lowland moist tropical forest in Trinidad, West Indies with three aims (I) to describe the echolocation calls of the members of a diverse Neotropical bat community, especially members of the family Phyllostomidae, whose calls are not well documented (2) to investigate whether multivariate analysis of calls allows species and foraging guilds to be identified and (3) to evaluate the use of bat detectors in surveying the phyllostomids of Neotropical forests. The calls of 12 species of the family Phyllostomidae are described here for the first time and a total of 29 species, belonging to five families (Emballonuridae, Mormoopidae, Phyllostomidae, Molossidae and Vespertilionidae) were recorded Quadratic discriminant function analysis (DFA) was used to obtain classification rates for each one of 11 individual species and for six guilds (based on diet, foraging mode and habitat) comprising 26 species Overall classification rates were low compared to similar studies conducted in the Palaeotropics We suggest that this may be due to a combination of ecological plasticity for certain species and a loose relationship between echolocation call shape, fine-grained resource partitioning and resource acquisition in phyllostomids

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Recombinant viruses based on the attenuated vaccinia virus strain NYVAC are promising HIV vaccine candidates as phase I/II clinical trials have shown good safety and immunogenicity profiles. However, this NYVAC strain is non-replicating in most human cell lines and encodes viral inhibitors of the immune system. Methods: With the aim to increase the immune potency of the current NYVAC-C vector (expressing the codon optimized clade C HIV-1 genes encoding gp120 and Gag-Pol-Nef polyprotein), we have generated and characterized three NYVAC-C-based vectors by, 1) deletion of the viral type I IFN inhibitor gene (NYVAC-CdeltaB19R), 2) restoration of virus replication competence in human cells by re-inserting K1L and C7L host range genes (NYVAC-C-KC) and, 3) combination of both strategies (NYVACC- KC-deltaB19R). Results: Insertion of the KC fragment restored the replication competence of the viruses in human cells (HeLa cells and primary dermal fibroblasts and keratinocytes), increased the expression of HIV antigens by more than 3-fold compared to the non-replicating homologs, inhibited apoptosis induced by the parental NYVAC-C and retained attenuation in a newborn mouse model. In adult mice, replication-competent viruses showed a limited capacity to replicate in tissues surrounding the inoculation site (ovaries and lymph nodes). After infection of keratinocytes, PBMCs and dendritic cells these viruses induced differential modulation in specific host cell signal transduction pathways, triggering genes important in immune modulation. Conclusion: We have developed improved NYVAC-C-based vectors with enhanced HIV-1 antigen expression, with the ability to replicate in cultured human cells and partially in some tissues, with an induced expression of cellular genes relevant to immune system activation, and which trigger IFN-dependent and independent signalling pathways, while maintaining a safety phenotype. These new vectors are promising new HIV vaccine candidates. These studies were performed within the Poxvirus Tcell Vaccine Discovery Consortium (PTVDC) which is part of the CAVD program.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A traditional photonic-force microscope (PFM) results in huge sets of data, which requires tedious numerical analysis. In this paper, we propose instead an analog signal processor to attain real-time capabilities while retaining the richness of the traditional PFM data. Our system is devoted to intracellular measurements and is fully interactive through the use of a haptic joystick. Using our specialized analog hardware along with a dedicated algorithm, we can extract the full 3D stiffness matrix of the optical trap in real time, including the off-diagonal cross-terms. Our system is also capable of simultaneously recording data for subsequent offline analysis. This allows us to check that a good correlation exists between the classical analysis of stiffness and our real-time measurements. We monitor the PFM beads using an optical microscope. The force-feedback mechanism of the haptic joystick helps us in interactively guiding the bead inside living cells and collecting information from its (possibly anisotropic) environment. The instantaneous stiffness measurements are also displayed in real time on a graphical user interface. The whole system has been built and is operational; here we present early results that confirm the consistency of the real-time measurements with offline computations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stimulated echoes are widely used for imaging functional tissue parameters such as diffusion coefficient, perfusion, and flow rates. They are potentially interesting for the assessment of various cardiac functions. However, severe limitations of the stimulated echo acquisition mode occur, which are related to the special dynamic properties of the beating heart and flowing blood. To the well-known signal decay due to longitudinal relaxation and through-plane motion between the preparation and the read-out period of the stimulated echoes, additional signal loss is often observed. As the prepared magnetization is fixed with respect to the tissue, this signal loss is caused by the tissue deformation during the cardiac cycle, which leads to a modification of the modulation frequency of the magnetization. These effects are theoretically derived and corroborated by phantom and in vivo experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the problem of frame-level symboltiming acquisition for UWB signals is addressed. The main goalis the derivation of a frame-level timing estimator which does notrequire any prior knowledge of neither the transmitted symbolsnor the received template waveform. The independence withrespect to the received waveform is of special interest in UWBcommunication systems, where a fast and accurate estimation ofthe end-to-end channel response is a challenging and computationallydemanding task. The proposed estimator is derived under theunconditional maximum likelihood criterion, and because of thelow power of UWB signals, the low-SNR assumption is adopted. Asa result, an optimal frame-level timing estimator is derived whichoutperforms existing acquisition methods in low-SNR scenarios.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective of this research was to examine the relationship between surface electromyographic (SEMG) spike activity and force. The secondary objective was to determine to what extent subcutaneous tissue impacts the high frequency component of the signal, as well as, examining the relationship between measures of SEMG spike shape and their traditional time and frequency analogues. A total of96 participants (46 males and 50 females) ranging in age (18-35 years), generated three 5-second isometric step contractions at each force level of 40, 60, 80, and 100 percent of maximal voluntary contraction (MVC). The presentation of the contractions was balanced across subjects. The right arm of the subject was positioned in the sagittal plane, with the shoulder and elbow flexed to 90 degrees. The elbow rested on a support in a neutral position (mid pronation/mid supination) and placed within a wrist cuff, fastened below the styloid process. The wrist cuff was attached to a load cell (JR3 Inc., Woodland, CA) recording the force produced. Biceps brachii activity was monitored with a pair of Ag/AgCI recording electrodes (Grass F-E9, Astro-Med Inc., West Warwick, RI) placed in a bipolar configuration, with an interelectrode distance (lED) of 2cm distal to the motor point. Data analysis was performed on a I second window of data in the middle of the 5-second contraction. The results indicated that all spike shape measures exhibited significant (p < 0.01) differences as force increase~ from 40 to 100% MVC. The spike shape measures suggest that increased motor unit (MU) recruitment was responsible for increasing force up to 80% MVC. The results suggested that further increases in force relied on MU III synchronization. The results also revealed that the subcutaneous tissue (skin fold thickness) had no relationship (r = 0.02; P > 0.05) with the mean number of peaks per spike (MNPPS), which was the high frequency component of the signal. Mean spike amplitude (MSA) and mean spike frequency (MSF) were highly correlated with their traditional measures root mean square (RMS) and mean power frequency (MPF), respectively (r = 0.99; r = 0.97; P < 0.01).