911 resultados para ECHOCARDIOGRAPHIC MEASUREMENTS
Resumo:
Arterial stiffness is an independent marker of cardiovascular events. Pulse wave velocity (PWV) is a validated method to detect arterial stiffness that can be influenced by several factors including age and blood pressure. However, it is not clear whether PWV could be influenced by circadian variations. In the present study, the authors measured blood pressure and carotid-femoral PWV measurements in 15 young healthy volunteers in 4 distinct periods: 8 am, noon, 4 pm, and 8 pm. No significant variations of systolic (P=.92), mean (P=.77), and diastolic (P=.66) blood pressure among 8 am (113 +/- 15, 84 +/- 8, 69 +/- 6 mm Hg), noon (114 +/- 13, 83 +/- 8, 68 +/- 6 mm Hg), 4 pm (114 +/- 13, 85 +/- 8, 70 +/- 7 mm Hg), and 8 pm (113 +/- 7, 83 +/- 10, 68 +/- 7 mm Hg), respectively, were observed. Similarly, carotid-femoral PWV did not change among the periods (8 am: 7.6 +/- 1.4 m/s, noon: 7.4 +/- 1.1 m/s, 4 pm: 7.6 +/- 1.0 m/s, 8 pm, 7.6 +/- 1.3 m/s; P=.85). Considering all measurements, mean blood pressure significantly correlated with PWV (r=.31; P=.016). In young healthy volunteers, there is no significant circadian variation of carotid-femoral PWV. These findings support the concept that it does not appear mandatory to perform PWV measurements at exactly the same period of the day. J Clin Hypertens (Greenwich). 2011;13:19-22. (c) 2010 Wiley Periodicals, Inc.
Resumo:
Objective. To determine if knee alignment measures differ between African Americans and Caucasians without radiographic knee osteoarthritis (rOA). Methods. A single knee was randomly selected from 175 participants in the Johnston County Osteoarthritis Project without rOA in either knee. Anatomic axis, condylar, tibia] plateau, and condylar plateau angles were measured by I radiologist; means were compared and adjusted for age and body mass index (BMI). Results. There were no significant differences in knee alignment measurements between Caucasians and African Americans among men or women. Conclusion. Observed differences in knee rOA occurrence between African Americans and Caucasians are not explained by differences in static knee alignment. (First Release July 15 2009; J Rheumatol 2009;36:1987-90; doi: 10.3899/jrheum.081294)
Resumo:
The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.
Resumo:
Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Background: Although the influence of respiration on ventricular filling, as evaluated by Doppler technique, and the evaluation of diastolic velocities of mitral valve annulus (MVA), as measured by Doppler tissue imaging (DTI), can provide valuable information for the study of left ventricular (LV) diastolic function, the concomitant effects of aging, tidal volume (TV), and respiratory rate (RR) on these velocities have not been quantitatively investigated. Methods: We evaluated 12 normal male volunteers (Group I) aged 20-26 years (mean: 22.8) and 8 normal subjects aged 41 to 54 years old (mean: 45.9) (Group II). Using DTI we measured peak early (E-a) and late (A(a)) velocities of longitudinal axis expansion at lateral and medial MVA. Doppler mitral and tricuspid flow velocities were measured: peak early (E) and late (A) inflow velocity, early (E-i) and late (A(i)) flow integral, and deceleration time of peak early mitral flow velocity (DT). Respiratory cycles were simultaneously recorded at RR of 9, 12, 15, and 18 cycles/min and TV of 600 and 900 mL during respiration (RESP). Results and conclusions: (1) E, A, and A(i) in MV had negligible change during respiration, but E-i was significantly reduced during inspiration; (2) DT reduced slightly with inspiration, but the change was significant only with TV of 900 mL; (3) an important increase of E in right ventricular flow was observed during inspiration; (4) variations of RR and TV did not significantly influence right and left ventricular inflow in normal subjects, in the conditions of this investigation; (5) a significant increase of E-a at medial MVA was documented during inspiration only in young subjects; (6) a significant decrease of A(a) at medial MVA was observed during inspiration in both groups of volunteers; (7) RR and TV did not influence MVA velocities in young and adult subjects; (8) a consistent reduction in E-a and a significant increase in A(a) were observed with increasing age; (9) these changes were more conspicuous and consistent than those documented in ventricular filling when young and middle-age men are compared, suggesting that the DTI is more sensitive to detect changes in diastolic function; and (10) in addition, these data suggest that, for evaluation of diastolic function, in clinical context, it is not necessary to control rigorously RR or TV.
Resumo:
Thus far, little has been written concerning echocarchographic identification of the oblique of the left atrium, or Marshall`s vein. There is much discussion, nonetheless, on the potential significance of the vein, or its ligamentous remnant, as an arrhythmic substrate. We describe here four patients in whom transthoracic echocardiography revealed a venous structure protruding within the cavity of the left atrium. We discuss the possibility that these structures represent Marshall`s vein, albeit probably as part of a persistent left superior caval vein.