895 resultados para Drop Tests
Resumo:
Objective: To compare head relocation accuracy in traumatic ( whiplash), insidious onset neck pain patients and asymptomatic subjects when targeting a natural head posture (NHP) and complex predetermined positions. Design: A case-control study. Setting: University-based musculoskeletal research clinic. Participants: Sixty-three volunteers divided into three groups of similar gender and age: Group 1 (n=21) an asymptomatic group; group 2 (n=20) insidious onset neck pain; group 3 (n=22) a history of whiplash injury. Intervention: Five randomly ordered tests designed to detect relocation accuracy of the head. Outcome measures: A 3-Space Fastrak system measured the mean absolute relocation error of three trials of each relocation test. Results: A significant difference was found between groups in one of the tests targeting the NHP (p=0.001). Post-hoc pairwise comparisons revealed a significant difference (pless than or equal to0.05) between the asymptomatic group and each symptomatic group. The difference between the symptomatic groups just failed to reach significance (p=0.07). None of the other four tests revealed significant differences. Conclusion: The test of targeting the NHP indicates that relocation inaccuracy exists in patients with neck pain with a trend to suggest that the deficit may be greater in whiplash patients. Tests employing unfamiliar postures or more complex movement were not successful in differentiating subject groups.
Resumo:
Objective To develop and validate specific, sensitive and rapid diagnostic tests using RT-PCR for the detection of Ross River virus (RRV), Kunjin virus (KV) and Murray Valley encephalitis virus (MVEV) infections in horses. Methods Primer sets based on nucleotide sequence encoding the envelope glycoprotein E2 of RRV and on the nonstructural protein 5 (NS5) of KV and MVEV were designed and used in single round PCRs to test for the respective viruses in infected cell cultures and, in the case of RRV, in samples of horse blood and synovial fluid. Results The primer pairs designed for each of the three viruses amplified a product of expected size from prototype viruses that were grown in cell culture. The identity of each of the products was confirmed by nucleotide sequencing indicating that in the context used the RT-PCRs were specific. RRV was detected in serums from 8 horses for which there were clinical signs consistent with RRV infection such that an acute-phase serum sample was taken and submitted for RRV serology testing. The RRV RT-PCR was analytically sensitive in that it was estimated to detect as little as 50 TCID50 of RRV per mL of serum and was specific in that the primer pairs did not amplify other products from the 8 serum samples. The RRV primers also detected virus in three independent mosquito pools known to contain RRV by virus isolation in cell culture. Samples from horses suspected to be infected with KV and MVEV were not available. Conclusion Despite much anecdotal and serological evidence for infection of horses with RRV actual infection and associated clinical disease are infrequently confirmed. The availability of a specific and analytically sensitive RT-PCR for the detection of RRV provides additional opportunities to confirm the presence of this virus in clinical samples. The RTPCR primers for the diagnosis of KV and MVEV infections were shown to be specific for cell culture grown viruses but the further validation of these tests requires the availability of appropriate clinical samples from infected horses.
Resumo:
Wireless medical systems are comprised of four stages, namely the medical device, the data transport, the data collection and the data evaluation stages. Whereas the performance of the first stage is highly regulated, the others are not. This paper concentrates on the data transport stage and argues that it is necessary to establish standardized tests to be used by medical device manufacturers to provide comparable results concerning the communication performance of the wireless networks used to transport medical data. Besides, it suggests test parameters and procedures to be used to produce comparable communication performance results.
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
Multiple-Choice items are used in many different kinds of tests in several areas of knowledge. They can be considered an interesting tool to the self-assessing or as an alternative or complementary instrument to the traditional methods for assessing knowledge. The objectivity and accuracy of the multiple-choice tests is an important reason to think about. They are especially useful when the number of students to evaluate is too large. Moodle (Modular Object-Oriented Dynamic Learning Environment) is an Open Source course management system centered around learners' needs and designed to support collaborative approaches to teaching and learning. Moodle offers to the users a rich interface, context-specific help buttons, and a wide variety of tools such as discussion forums, wikis, chat, surveys, quizzes, glossaries, journals, grade books and more, that allow them to learn and collaborate in a truly interactive space. Come together the interactivity of the Moodle platform and the objectivity of this kind of tests one can easily build manifold random tests. The proposal of this paper is to relate our journey in the construction of these tests and share our experience in the use of the Moodle platform to create, take advantage and improve the multiple-choices tests in the Mathematic area.
Resumo:
The purpose of this paper is to analyse if Multiple-Choice Tests may be considered an interesting alternative for assessing knowledge, particularly in the Mathematics area, as opposed to the traditional methods, such as open questions exams. In this sense we illustrate some opinions of the researchers in this area. Often the perception of the people about the construction of this kind of exams is that they are easy to create. But it is not true! Construct well written tests it’s a hard work and needs writing ability from the teachers. Our proposal is analyse the construction difficulties of multiple - choice tests as well some advantages and limitations of this type of tests. We also show the frequent critics and worries, since the beginning of this objective format usage. Finally in this context some examples of Multiple-Choice Items in the Mathematics area are given, and we illustrate as how we can take advantage and improve this kind of tests.
Resumo:
We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg−1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.
Resumo:
Mestrado em Engenharia Química. Ramo de Optimização Energética na Indústria Química
Resumo:
A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
Resumo:
The treatment efficiency of laboratory wastewaters was evaluated and ecotoxicity tests with Chlorella vulgaris were performed on them to assess the safety of their environmental discharge. For chemical oxygen demand wastewaters, chromium (VI), mercury (II) and silver were efficiently removedby chemical treatments.Areduction of ecotoxicitywas achieved; nevertheless, an EC50 (effective concentration that causes a 50% inhibition in the algae growth) of 1.5% (v/v) indicated still high level of ecotoxicity. For chloride determination wastewaters, an efficient reduction of chromium and silver was achieved after treatment. Regarding the reduction of ecotoxicity observed, EC50 increased from 0.059% to 0.5%, only a 0.02% concentration in the aquatic environment would guarantee no effects. Wastewaters containing phenanthroline/iron (II) complex were treated by chemical oxidation. Treatmentwas satisfactory concerning chemical parameters, although an increase in ecotoxicitywas observed (EC50 reduced from 0.31% to 0.21%). The wastes from the kinetic study of persulphate and iodide reaction were treated with sodium bisulphite until colour was removed. Although they did not reveal significant ecotoxicity, only over 1% of the untreated waste produced observable effects over algae. Therefore, ecotoxicity tests could be considered a useful tool not only in laboratory effluents treatment, as shown, but also in hazardous wastewaters management.
Resumo:
In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si: H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.
Resumo:
This paper presents a layered Smart Grid architecture enhancing security and reliability, having the ability to act in order to maintain and correct infrastructure components without affecting the client service. The architecture presented is based in the core of well design software engineering, standing upon standards developed over the years. The layered Smart Grid offers a base tool to ease new standards and energy policies implementation. The ZigBee technology implementation test methodology for the Smart Grid is presented, and provides field tests using ZigBee technology to control the new Smart Grid architecture approach. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Between 2000/01 and 2006/07, the approval rate of a Thermodynamics course in a Mechanical Engineer graduation was 25%. However, a careful analysis of the results showed that 41% of the students chosen not to attend or dropped out, missing the final examination. Thus, a continuous assessment methodology was developed, whose purpose was to reduce drop out, motivating students to attend this course, believing that what was observed was due, not to the incapacity to pass, but to the anticipation of the inevitability of failure by the students. If, on one hand, motivation is defined as a broad construct pertaining to the conditions and processes that account for the arousal, direction, magnitude, and maintenance of effort, on the other hand, assessment is one of the most powerful tools to change the will that students have to learn, motivating them to learn in a quicker and permanent way. Some of the practices that were implemented, included: promoting learning goal orientation rather than performance goal orientation; cultivating intrinsic interest in the subject and put less emphasis on grades but make grading criteria explicit; emphasizing teaching approaches that encourage collaboration among students and cater for a range of teaching styles; explaining the reasons for, and the implications of, tests; providing feedback to students about their performance in a form that is non-egoinvolving and non-judgemental and helping students to interpret it; broadening the range of information used in assessing the attainment of individual students. The continuous assessment methodology developed was applied in 2007/08 and 2008/09, having found an increase in the approval from 25% to 55% (30%), accompanied by a decrease of the drop out from 41% to 23,5% (17,5%). Flunking with a numerical grade lowered from 34,4% to 22,0% (12,4%). The perception by the students of the continuous assessment relevance was evaluated with a questionnaire. 70% of the students that failed the course respond that, nevertheless, didn’t repent having done the continuous assessment.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.