991 resultados para Distributed fiber optic sensors
Resumo:
We propose a simple method for passive nonlinear optical pulse shaping that utilizes pulse prechirping and nonlinear propagation in a normally dispersive nonlinear fiber to generate various temporal waveforms of practical interest from conventional laser pulses.
Resumo:
This review offers new perspectives on the subject and highlights an area in need of further research. It includes an analysis of current scientific literature mainly covering the last decade and examines the trends in the development of electronic, acoustic and optical-fiber humidity sensors over this period. The major findings indicate that a new generation of sensor technology based on optical fibers is emerging. The current trends suggest that electronic humidity sensors could soon be replaced by sensors that are based on photonic structures. Recent scientific advances are expected to allow dedicated systems to avoid the relatively high price of interrogation modules that is currently a major disadvantage of fiber-based sensors.
Resumo:
The use of near infrared, high intensity femtosecond laser pulses for the inscription of long period fiber gratings in photonic crystal fiber is reported. The formation of grating structures in photonic crystal fiber is complicated by the fiber structure that allows wave-guidance but that impairs and scatters the femtosecond inscription beam. The effects of symmetric and asymmetric femtosecond laser inscriptions are compared and the polarization characteristics of long period gratings and their responses to external perturbations are reported.
Resumo:
We present a new class of multi-channel Fiber Bragg grating, which provides the characteristics of channelized dispersion but does so with only a single reflection band. Such gratings can provide pure phase control of optical pulses without introducing any deleterious insertion-loss-variation. © 2006 Optical Society of America.
Resumo:
We propose a novel approach to pulse shaping using a phase-modulated fiber Bragg gratings (FBGs) in transmission. This enables the simplification of the device fabrication while retaining the substantial advantages of FBGs in transmission. © 2013 OSA.
Resumo:
Long period gratings (LPGs) were written into a D-shaped optical fibre, which has an elliptical core with a W-shaped refractive index profile. The LPG's attenuation bands were found to be sensitive to the polarisation of the interrogating light with a spectral separation of about 15nm between the two orthogonal polarisation states. In addition, two spectrally overlapping attenuation bands corresponding to orthogonal polarisation states were observed; modelling successfully reproduced this spectral feature. The spectral sensitivity of both orthogonal states was experimentally measured with respect to temperature, surrounding refractive index, and directional bending. These LPG devices produced blue and red wavelength shifts of the stop-bands due to bending in different directions. The measured spectral sensitivities to curvatures, d?/dR , ranged from -3.56nm m to +6.51nm m. The results obtained with these LPGs suggest that this type of fibre may be useful as a shape/bend sensor. It was also demonstrated that the neighbouring bands could be used to discriminate between temperature and bending and that overlapping orthogonal polarisation attenuation bands can be used to minimise error associated with polarisation.
Resumo:
We demonstrated an Erbium-doped picosecond fiber laser mode locked by carbon nanotube in N-methyl-2-pryrrolidone solvent in an in-fiber micro-channel. © 2011 Optical Society of America.
Resumo:
In this paper, the level of dynamics, as described by the Assessment Dynamic Ratio (ADR), is measured directly through a field test on a bridge in the United Kingdom. The bridge was instrumented using fiber optic strain sensors and piezo-polymer weigh-in-motion sensors were installed in the pavement on the approach road. Field measurements of static and static-plus-dynamic strains were taken over 45 days. The results show that, while dynamic amplification is large for many loading events, these tend not to be the critical events. ADR, the allowance that should be made for dynamics in an assessment of safety, is small.
Resumo:
A finite element analysis and a parametric optimization of single-axis acoustic levitators are presented. The finite element method is used to simulate a levitator consisting of a Langevin ultrasonic transducer with a plane radiating surface and a plane reflector. The transducer electrical impedance, the transducer face displacement, and the acoustic radiation potential that acts on small spheres are determined by the finite element method. The numerical electrical impedance is compared with that acquired experimentally by an impedance analyzer, and the predicted displacement is compared with that obtained by a fiber-optic vibration sensor. The numerical acoustic radiation potential is verified experimentally by placing small spheres in the levitator. The same procedure is used to optimize a levitator consisting of a curved reflector and a concave-faced transducer. The numerical results show that the acoustic radiation force in the new levitator is enhanced 604 times compared with the levitator consisting of a plane transducer and a plane reflector. The optimized levitator is able to levitate 3, 2.5-mm diameter steel spheres with a power consumption of only 0.9 W.
Resumo:
The demand for more pixels is beginning to be met as manufacturers increase the native resolution of projector chips. Tiling several projectors still offers a solution to augment the pixel capacity of a display. However, problems of color and illumination uniformity across projectors need to be addressed as well as the computer software required to drive such devices. We present the results obtained on a desktop-size tiled projector array of three D-ILA projectors sharing a common illumination source. A short throw lens (0.8:1) on each projector yields a 21-in. diagonal for each image tile; the composite image on a 3×1 array is 3840×1024 pixels with a resolution of about 80 dpi. The system preserves desktop resolution, is compact, and can fit in a normal room or laboratory. The projectors are mounted on precision six-axis positioners, which allow pixel level alignment. A fiber optic beamsplitting system and a single set of red, green, and blue dichroic filters are the key to color and illumination uniformity. The D-ILA chips inside each projector can be adjusted separately to set or change characteristics such as contrast, brightness, or gamma curves. The projectors were then matched carefully: photometric variations were corrected, leading to a seamless image. Photometric measurements were performed to characterize the display and are reported here. This system is driven by a small PC cluster fitted with graphics cards and running Linux. It can be scaled to accommodate an array of 2×3 or 3×3 projectors, thus increasing the number of pixels of the final image. Finally, we present current uses of the display in fields such as astrophysics and archaeology (remote sensing).
Resumo:
The microwave and thermal cure processes for the epoxy-amine systems (epoxy resin diglycidyl ether of bisphenol A, DGEBA) with 4,4'-diaminodiphenyl sulphone (DDS) and 4,4'-diaminodiphenyl methane (DDM) have been investigated for 1:1 stoichiometries by using fiber-optic FT-NIR spectroscopy. The DGEBA used was in the form of Ciba-Geigy GY260 resin. The DDM system was studied at a single cure temperature of 373 K and a single stoichiometry of 20.94 wt% and the DDS system was studied at a stoichiometry of 24.9 wt% and a range of temperatures between 393 and 443 K. The best values of the kinetic rate parameters for the consumption of amines have been determined by a least squares curve fit to a model for epoxy/amine cure. The activation energies for the polymerization of the DGEBA/DDS system were determined for both cure processes and found to be 66 and 69 kJ mol(-1) for the microwave and thermal cure processes, respectively. No evidence was found for any specific effect of the microwave radiation on the rate parameters, and the systems were both found to be characterized by a negative substitution effect. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
The operation of generalized Marx-type solid-state bipolar modulators is discussed and compared with simplified Marx-derived circuits, to evaluate their capability to deal with various load conditions. A comparative analysis on the number of switches per cell, fiber optic trigger count, losses, and switch hold-off voltages has been made. A circuit topology is obtained as a compromise in terms of operating performance, trigger simplicity, and switching losses. A five-stage laboratory prototype of this circuit has been assembled using 1200 V insulated gate bipolar transistors (IGBTs) and diodes, operating with 1000 V dc input voltage and 1 kHz frequency, giving 5 kV bipolar pulses, with 2.5 mu s pulse width and 5 mu s relaxation time into resistive, capacitive, and inductive loads.
Resumo:
The development of biopharmaceutical manufacturing processes presents critical constraints, with the major constraint being that living cells synthesize these molecules, presenting inherent behavior variability due to their high sensitivity to small fluctuations in the cultivation environment. To speed up the development process and to control this critical manufacturing step, it is relevant to develop high-throughput and in situ monitoring techniques, respectively. Here, high-throughput mid-infrared (MIR) spectral analysis of dehydrated cell pellets and in situ near-infrared (NIR) spectral analysis of the whole culture broth were compared to monitor plasmid production in recombinant Escherichia coil cultures. Good partial least squares (PLS) regression models were built, either based on MIR or NIR spectral data, yielding high coefficients of determination (R-2) and low predictive errors (root mean square error, or RMSE) to estimate host cell growth, plasmid production, carbon source consumption (glucose and glycerol), and by-product acetate production and consumption. The predictive errors for biomass, plasmid, glucose, glycerol, and acetate based on MIR data were 0.7 g/L, 9 mg/L, 0.3 g/L, 0.4 g/L, and 0.4 g/L, respectively, whereas for NIR data the predictive errors obtained were 0.4 g/L, 8 mg/L, 0.3 g/L, 0.2 g/L, and 0.4 g/L, respectively. The models obtained are robust as they are valid for cultivations conducted with different media compositions and with different cultivation strategies (batch and fed-batch). Besides being conducted in situ with a sterilized fiber optic probe, NIR spectroscopy allows building PLS models for estimating plasmid, glucose, and acetate that are as accurate as those obtained from the high-throughput MIR setup, and better models for estimating biomass and glycerol, yielding a decrease in 57 and 50% of the RMSE, respectively, compared to the MIR setup. However, MIR spectroscopy could be a valid alternative in the case of optimization protocols, due to possible space constraints or high costs associated with the use of multi-fiber optic probes for multi-bioreactors. In this case, MIR could be conducted in a high-throughput manner, analyzing hundreds of culture samples in a rapid and automatic mode.
Resumo:
BACKGROUNDWhile the pharmaceutical industry keeps an eye on plasmid DNA production for new generation gene therapies, real-time monitoring techniques for plasmid bioproduction are as yet unavailable. This work shows the possibility of in situ monitoring of plasmid production in Escherichia coli cultures using a near infrared (NIR) fiber optic probe. RESULTSPartial least squares (PLS) regression models based on the NIR spectra were developed for predicting bioprocess critical variables such as the concentrations of biomass, plasmid, carbon sources (glucose and glycerol) and acetate. In order to achieve robust models able to predict the performance of plasmid production processes, independently of the composition of the cultivation medium, cultivation strategy (batch versus fed-batch) and E. coli strain used, three strategies were adopted, using: (i) E. coliDH5 cultures conducted under different media compositions and culture strategies (batch and fed-batch); (ii) engineered E. coli strains, MG1655endArecApgi and MG1655endArecA, grown on the same medium and culture strategy; (iii) diverse E. coli strains, over batch and fed-batch cultivations and using different media compositions. PLS models showed high accuracy for predicting all variables in the three groups of cultures. CONCLUSIONNIR spectroscopy combined with PLS modeling provides a fast, inexpensive and contamination-free technique to accurately monitoring plasmid bioprocesses in real time, independently of the medium composition, cultivation strategy and the E. coli strain used.
Resumo:
Ao longo dos últimos anos, vários esforços e estudos foram feitos com o objetivo de colocar a fibra ótica no mercado, como um sistema preferencial de monitorização das mais diversas obras de Engenharia. Os sensores baseados na tecnologia em fibra ótica apresentam vantagens reconhecidas pelos mais diversos especialistas, sendo atualmente reconhecida como uma das soluções mais eficazes. Na engenharia Civil, a monitorização das grandes obras tem ganho uma importância crescente. Neste contexto, a monitorização de convergências em túneis visa o controlo da respectiva integridade estrutural ao longo da construção e a exploração da obra. Atualmente a solução de monitorização estrutural de túneis utilizada pela FiberSensing é uma solução desenhada em conjunto com a EPOS e o Cegeo (IST), baseada em sensores de Bragg em Fibra Ótica: o SysTunnel. O objetivo do estudo de uma solução alternativa encontra-se no facto do SysTunnel apresentar algumas debilidades no algoritmo de cálculo, sendo para o seu cálculo necessário a introdução de um parâmetro relacionado com o solo envolvente do túnel, facto que introduz incertezas no cálculo das convergências. O presente relatório tem como finalidade documentar o estágio curricular realizado na FiberSensing, entre 01/02/2014 a 31/07/2014. Este estágio teve como objetivo o desenvolvimento de uma solução alternativa de monitorização estrutural baseada na tecnologia das redes de Bragg para a monitorização das convergências em túneis.