947 resultados para Diamond cutters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backgroud: The influence of diamond-like-carbon (DLC) films on bacterial leakage through the interface between abutments and dental implants of external hexagon (EH) and internal hexagon (IH) was evaluated. Film deposition was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition). Sets of implants and abutments (N=180, n=30) were divided according to the connection design and the treatment of the abutment base: (1) no treatment (control); (2) DLC film deposition, and (3) Ag-DLC film deposition. Under sterile conditions, 1 µL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed-up for five days. Turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper points and plated in Petri dishes. They were incubated for 24 h for bacterial viability assessment and colony-forming unit (CFU) counting. Bacterial leakage was analyzed by Chi-square and Fisher exact tests (α=5%). The percentage of bacterial leakage was 16.09% for EH implants and 80.71% for IH implants (P<0.0001). The bacterial load was higher inside these implants (P=0.000). The type of implant significantly influenced the results (P=0.000), whereas the films did not (P=0.487). We concluded that: (1) IH implants showed a higher frequency of bacterial leakage and (2) the DLC and Ag-DLC films did not significantly reduce the frequency of bacterial leakage and bacteria load inside the implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the currently strict environmental law in present days, researchers and industries are seeking to reduce the amount of cutting fluid used in machining. Minimum quantity lubrication is a potential alternative to reduce environmental impacts and overall process costs. This technique can substantially reduce cutting fluids in grinding, as well as provide better performance in relation to conventional cutting fluid application (abundant fluid flow). The present work aims to test the viability of minimum quantity lubrication (with and without water) in grinding of advanced ceramics, when compared to conventional method (abundant fluid flow). Measured output variables were grinding power, surface roughness, roundness errors and wheel wear, as well as scanning electron micrographs. The results show that minimum quantity lubrication with water (1:1) was superior to conventional lubrication-cooling in terms of surface quality, also reducing wheel wear, when compared to the other methods tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have explored the suitability and characteristics of interface tailoring as a tool for enhancing the adhesion of hydrogen-free diamond-like carbon (DLC) thin films to silicon substrates. DLC films were deposited on silicon with and without application of an initial high energy carbon ion bombardment phase that formed a broad Si-C interface of gradually changing Si:C composition. The interface depth profile was calculated using the TRIDYN simulation program, revealing a gradient of carbon concentration including a region with the stoichiometry of silicon carbide. DLC films on silicon, with and without interface tailoring, were characterized using Raman spectroscopy, scanning electron microscopy, atomic force microscopy and scratch tests. The Raman spectroscopy results indicated sp3-type carbon bonding content of up to 80%. Formation of a broadened Si:C interface as formed here significantly enhances the adhesion of DLC films to the underlying silicon substrate. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have explored the effects of atmospheric environment on Kelvin force microscopy (KFM) measurements of potential difference between different regions of test polycrystalline diamond surfaces. The diamond films were deposited by microwave plasma-assisted chemical vapor deposition, which naturally produces hydrogen terminations on the surface of the films formed. Selected regions were patterned by electron-beam lithography and chemical terminations of oxygen or fluorine were created by exposure to an oxygen or fluorine plasma source. For KFM imaging, the samples were mounted in a hood with a constant flow of helium gas. Successive images were taken over a 5-h period showing the effect of the environment on KFM imaging. We conclude that the helium flow removes water molecules adsorbed on the surface of the samples, resulting in differences in surface potential between adjacent regions. The degree of water removal is different for surfaces with different terminations. The results highlight the importance of taking into account the atmospheric environment when carrying out KFM analysis. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thiadiazolylurea derivative tebuthiuron (TBH) is commonly used as an herbicide even though it is highly toxic to humans. While various processes have been proposed for the removal of organic contaminants of this type from wastewater, electrochemical degradation has shown particular promise. The aim of the present study was to investigate the electrochemical degradation of TBH using anodes comprising boron-doped (5000 and 30000 ppm) diamond (BDD) films deposited onto Ti substrates operated at current densities in the range 10-200 mA cm(-2). Both anodes removed TBH following a similar pseudo first-order reaction kinetics with k(ap)p close to 3.2 x 10(-2) min(-1). The maximum mineralization efficiency obtained was 80%. High-pressure liquid chromatography with UV-VIS detection established that both anodes degraded TBH via similar intermediates. Ion chromatography revealed that increasing concentrations of nitrate ions (up to 0.9 ppm) were formed with increasing current density, while the formation of nitrite ions was observed with both anodes at current densities >= 150 mA cm(-2). The BDD film prepared at the lower doping level (5000 ppm) was more efficient in degrading TBH than its more highly doped counterpart. This unexpected finding may be explained in terms of the quantity of impurities incorporated into the diamond lattice during chemical vapor deposition. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe work in which gold nanoparticles were formed in diamond-like carbon (DLC), thereby generating a Au-DLC nanocomposite. A high-quality, hydrogen-free DLC thin film was formed by filtered vacuum arc plasma deposition, into which gold nanoparticles were introduced using two different methods. The first method was gold ion implantation into the DLC film at a number of decreasing ion energies, distributing the gold over a controllable depth range within the DLC. The second method was co-deposition of gold and carbon, using two separate vacuum arc plasma guns with suitably interleaved repetitive pulsing. Transmission electron microscope images show that the size of the gold nanoparticles obtained by ion implantation is 3-5 nm. For the Au-DLC composite obtained by co-deposition, there were two different nanoparticle sizes, most about 2 nm with some 6-7 nm. Raman spectroscopy indicates that the implanted sample contains a smaller fraction of sp(3) bonding for the DLC, demonstrating that some sp(3) bonds are destroyed by the gold implantation. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757029]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to show the dependence relationship between the crystallographic orientations upon brittle-to-ductile transition during diamond turning of monocrystalline silicon. Cutting tests were performed using a -5 degrees rake angle round nose diamond tool at different machining scales. At the micrometre level, the feedrate was kept constant at 2.5 micrometres per revolution (mu m/r), and the depth of cut was varied from 1 to 5 mu m. At the submicrometre level, the depth of cut was kept constant at 500 nm and the feedrate varied from 5 to 10 mu m/r. At the micrometre level, the uncut shoulder generated with an interrupted cutting test procedure provided a quantitative measurement of the ductile-to-brittle transition. Results show that the critical chip thickness in silicon for ductile material removal reaches a maximum of 285 nm in the [100] direction and a minimum of 115 nm in the [110] direction, when the depth of cut was 5 mu m. It was found that when a submicrometre depth of cut was applied, microcracks were revealed in the [110] direction, which is the softer direction in silicon. Micro Raman spectroscopy was used to estimate surface residual stress after machining. Compressive residual stress in the range 142 MPa and smooth damage free surface finish was probed in the [100] direction for a depth of cut of 5 mu m, whereas residual stresses in the range 350 MPa and brittle damage was probed in the [110] direction for a depth of cut of 500 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expansion of sugarcane monoculture in Brazil in the last decades has pointed out to the necessity of considering the question of sugarcane cutters occupational health. In this work we present a cross-sectional study aiming to examine the occupational posture of a group of sugarcane cutters, which work in a cane field located in the region of Pontal do Paranapanema-SP, Brazil. The study was made using the Ergonomic Analysis of Work - EAW methodology and the postural analysis method by Win-OWAS. Through the obtained records of postures, it was observed that during a workday the sugarcane cutters remain standing erect on two legs or in one leg 66% of the time and that their trunk remain tilted and in rotation, according to 63% of the positions categorized. It was also observed that the sugarcane cutter trunk performs repetitive and boundless movements during his routine of work, which can expose this individual to additional wear of their musculoskeletal functions. The activities in which the individual engages have favorable or adverse influence on his posture. The repetitive movements involved in specialized occupations are equivalent to repeated exercises, thus may be responsible for the excessive development of certain muscle groups. The study suggests that the postures adopted by sugarcane cutters can overload their musculoskeletal system and predispose the cutters to work-related musculoskeletal diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diamant ist das härteste Mineral – und dazu ein Edelstein -, das unter höchstem Druck und hohen Temperaturen in tiefen kontinentalen Regionen der Erde kristallisiert. Die Mineraleinschlüsse in Diamanten werden durch die physikalische Stabilität und chemische Beständigkeit der umgebenden – eigentlich metastabilen -Diamant-Phase geschützt. Aufgrund der koexistierenden Phasenkombination ermöglichen sie, die Mineral-Entwicklung zu studieren, während deren der Einschlüssen und die Diamanten kristallisierten. rnDie Phasenkombinationen von Diamant und Chrom-Pyrop, Chrom-Diopsid, Chromit, Olivin, Graphit und Enstatit nebeneinander (teilweise in Berührungsexistenz) mit Chrom-Pyrop Einschlüssen wurden von neunundzwanzig Diamant-Proben von sechs Standorten in Südafrika (Premier, Koffiefontein, De Beers Pool, Finsch, Venetia und Koingnaas Minen) und Udachnaya (Sibirien/Russland) identifiziert und charakterisiert. Die Mineraleinschlüsse weisen z.T. kubo-oktaedrische Form auf, die unabhängig von ihren eigenen Kristallsystemen ausgebildet werden können. Das bedeutet, dass sie syngenetische Einschlüsse sind, die durch die sehr hohe Formenergie des umgebenden Diamanten morphologisch unter Zwang stehen. Aus zweidiemnsionalen Messungen der ersten Ordnung von charakteristischen Raman-Banden lassen sich relative Restdrucke in Diamanten zwischen Diamant und Einschlussmineral gewinnen; sie haben charakteristische Werte von ca. 0,4 bis 0,9 GPa um Chrom-Pyrop-Einschlüsse, 0,6 bis 2,0 GPa um Chrom-Diopsid-Einschlüsse, 0,3 bis 1,2 GPa um Olivin-Einschlüsse, 0,2 bis 1,0 GPa um Chromit-Einschlüsse, beziehungsweise 0,5 GPa um Graphit Einschlüsse.rnDie kristallstrukturellen Beziehung von Diamanten und ihren monomineralischen Einschlüssen wurden mit Hilfe der Quantifizierung der Winkelkorrelationen zwischen der [111] Richtung von Diamanten und spezifisch ausgewählten Richtungen ihrer mineralischen Einschlüsse untersucht. Die Winkelkorrelationen zwischen Diamant [111] und Chrom-Pyrop [111] oder Chromit [111] zeigen die kleinsten Verzerrungen von 2,2 bis zu 3,4. Die Chrom-Diopsid- und Olivin-Einschlüsse zeigen die Missorientierungswerte mit Diamant [111] bis zu 10,2 und 12,9 von Chrom-Diopsid [010] beziehungsweise Olivin [100].rnDie chemische Zusammensetzung von neun herausgearbeiteten (orientiertes Anschleifen) Einschlüssen (drei Chrom-Pyrop-Einschlüsse von Koffiefontein-, Finsch- und Venetia-Mine (zwei von drei koexistieren nebeneinander mit Enstatit), ein Chromit von Udachnaya (Sibirien/Russland), drei Chrom-Diopside von Koffiefontein, Koingnaas und Udachnaya (Sibirien/Russland) und zwei Olivin Einschlüsse von De Beers Pool und Koingnaas) wurden mit Hilfe EPMA und LA-ICP-MS analysiert. Auf der Grundlage der chemischen Zusammensetzung können die Mineraleinschlüsse in Diamanten in dieser Arbeit der peridotitischen Suite zugeordnet werden.rnDie Geothermobarometrie-Untersuchungen waren aufgrund der berührenden Koexistenz von Chrom-Pyrop- und Enstatit in einzelnen Diamanten möglich. Durchschnittliche Temperaturen und Drücke der Bildung sind mit ca. 1087 (± 15) C, 5,2 (± 0,1) GPa für Diamant DHK6.2 von der Koffiefontein Mine beziehungsweise ca. 1041 (± 5) C, 5,0 (± 0,1) GPa für Diamant DHF10.2 von der Finsch Mine zu interpretieren.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, elemental research towards the implantation of a diamond-based molecular quantum computer is presented. The approach followed requires linear alignment of endohedral fullerenes on the diamond C(100) surface in the vicinity of subsurface NV-centers. From this, four fundamental experimental challenges arise: 1) The well-controlled deposition of endohedral fullerenes on a diamond surface. 2) The creation of NV-centers in diamond close to the surface. 3) Preparation and characterization of atomically-flat diamondsurfaces. 4) Assembly of linear chains of endohedral fullerenes. First steps to overcome all these challenges were taken in the framework of this thesis. Therefore, a so-called “pulse injection” technique was implemented and tested in a UHV chamber that was custom-designed for this and further tasks. Pulse injection in principle allows for the deposition of molecules from solution onto a substrate and can therefore be used to deposit molecular species that are not stable to sublimation under UHV conditions, such as the endohedral fullerenes needed for a quantum register. Regarding the targeted creation of NV-centers, FIB experiments were carried out in cooperation with the group of Prof. Schmidt-Kaler (AG Quantum, Physics Department, Johannes Gutenberg-Universität Mainz). As an entry into this challenging task, argon cations were implanted into (111) surface-oriented CaF2 crystals. The resulting implantation spots on the surface were imaged and characterized using AFM. In this context, general relations between the impact of the ions on the surface and their valency or kinetic energy, respectively, could be established. The main part of this thesis, however, is constituted by NCAFM studies on both, bare and hydrogen-terminated diamond C(100) surfaces. In cooperation with the group of Prof. Dujardin (Molecular Nanoscience Group, ISMO, Université de Paris XI), clean and atomically-flat diamond surfaces were prepared by exposure of the substrate to a microwave hydrogen plasma. Subsequently, both surface modifications were imaged in high resolution with NC-AFM. In the process, both hydrogen atoms in the unit cell of the hydrogenated surface were resolved individually, which was not achieved in previous STM studies of this surface. The NC-AFM images also reveal, for the first time, atomic-resolution contrast on the clean, insulating diamond surface and provide real-space experimental evidence for a (2×1) surface reconstruction. With regard to the quantum computing concept, high-resolution NC-AFM imaging was also used to study the adsorption and self-assembly potential of two different kinds of fullerenes (C60 and C60F48) on aforementioned diamond surfaces. In case of the hydrogenated surface, particular attention was paid to the influence of charge transfer doping on the fullerene-substrate interaction and the morphology emerging from self-assembly. Finally, self-assembled C60 islands on the hydrogen-terminated diamond surface were subject to active manipulation by an NC-AFM tip. Two different kinds of tip-induced island growth modes have been induced and were presented. In conclusion, the results obtained provide fundamental informations mandatory for the realization of a molecular quantum computer. In the process it was shown that NC-AFM is, under proper circumstances, a very capable tool for imaging diamond surfaces with highest resolution, surpassing even what has been achieved with STM up to now. Particular attention was paid to the influence of transfer doping on the morphology of fullerenes on the hydrogenated diamond surface, revealing new possibilities for tailoring the self-assembly of molecules that have a high electron affinity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

: Because the acinar cells of the exocrine pancreas in patients with Shwachman-Diamond syndrome (SDS) are severely depleted, we hypothesized that a similar deficiency may be present in acinar cells of the parotid gland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To show the effect of standard magnetic resonance imaging (MRI) in patients with suspected appendicitis on negative laparotomy and perforation rate. Moreover, the economic impact on hospital resources was evaluated.