466 resultados para Contração miocárdica
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas
Resumo:
Both skeletal and cardiac muscles daily burn tremendous amounts of ATP to meet the energy requirements for contraction. So, it is not surprising that the maintenance of mitochondrial morphology, number, distribution and functionality in striated muscle are important for muscle homeostasis. In these tissues mitochondria present the added dimension of two populations, the intermyofibrillar (IMF) and the subsarcolemmal (SS) mitochondria, being IMF the most abundant one. In the present thesis, the molecular mechanisms harboured in mitochondria of striated muscles were studied using animal models, to better comprehend the role of mitochondrial plasticity in several pathophysiological conditions such as aging, diabetes mellitus and bladder cancer. The comparative analysis of IMF and SS populations isolated from heart evidenced a higher respiratory chain activity of mitochondria interspersed in the contractile apparatus. The higher susceptible of SS respiratory chain complexes subunits to carbonylation, but not to nitration, seems to justify the lower respiratory chain activity observed in this mitochondrial population. Our results showed that in heart from aged mice there is an accumulation of dysfunctional mitochondria. The age-related decrease of oxidative phosphorylation activity seems to be justified, at least partially, by the increased proneness of mitochondrial proteins as OXPHOS subunits and MnSOD to oxidative modifications. Moreover, a sedentary lifestyle seems to worsen the functional consequences of aging in heart by increasing mitochondrial proteins susceptibility to nitration. In skeletal muscle from rats with type 1 diabetes mellitus induced by streptozotocin administration, we verified the accumulation of dysfunctional mitochondria due, at least in part, to the impairment of PQC system. Indeed, the decreased activity of AAA proteases was accompanied by the accumulation of oxidatively modified mitochondrial proteins with impact in respiratory chain activity. The diminishing of mitochondria activity also underlies cancer-induced muscle wasting. Indeed, using a rat model of chemically induced urothelial carcinoma we verified that the loss of gastrocnemius mass was related to mitochondrial dysfunction due to, at least partially, the down-regulation of PQC system involving the mitochondrial proteases paraplegin and Lon. PQC impairment resulted in the accumulation of oxidatively modified mitochondrial proteins. In overall, regardless the pathophysiological stimuli that promote mitochondrial alterations, there are similarities in the pattern of disease-related mitochondrial plasticity. The diminished capacity for ATP production in striated muscle seems to be due to increased oxidative damage of mitochondrial proteins, namely subunits of respiratory chain complexes, metabolic proteins and MnSOD. Our data highlighted, for the first time, the impact of mitochondrial PQC system impairment in the accumulation of oxidized proteins, exacerbating the dysfunction of this organelle in striated muscle in several pathophysiological conditions.
Resumo:
Este relatório de estágio tenta descrever todo o trabalho levado a cabo pela estagiária num escritório de advogados e baseia-se na tentativa de implementar ferramentas de gestão à fidelização de clientes existentes ou futuros. Constatando que em ciclo recessivo, ou de abrandamento de crescimento económico, existe contração da procura de serviços jurídicos por parte das famílias e por parte das empresas, torna-se essencial inverter a tendência recorrendo a aplicação de ferramentas de gestão para dinamizar a carteira de clientes. A existência de fortes condicionantes ao nível do código deontológico e de sigilo profissional impostos pelo próprio Estatuto da Ordem dos Advogados, inviabilizam os tradicionais meios de captação de clientes, assim como não favorece a captação de novos clientes. O setor da advocacia tem por característica ser um sector tradicionalmente fechado a profissionais da área da gestão e da economia, com a consequente impossibilidade de estes virem a ser sócios destas sociedades civis, o que leva a que sejam setores por vezes inadaptados a novas realidades de gestão para combater ciclo recessivos ou de diminuição da procura. A utilização de ferramentas de gestão como as de Gestão do Relacionamento -CRM, permitirá recolher uma vantagem interna, potenciando clientes atuais e clientes em arquivo “morto”. A gestão da carteira de clientes torna-se assim fundamental para minimizar os impactos dos ciclos económicos menos positivos.
Resumo:
Tese de doutoramento, Geografia (Planeamento Regional e Urbano), Universidade de Lisboa, Instituto de Geografia e Ordenamento do Território, 2014
Resumo:
Dissertação de Doutoramento em Saúde Pública;Especialidade em Política, Gestão e Administração
Resumo:
Introdução: A síndrome dolorosa miofascial (SDM) é uma das causas mais comuns de dor com origem músculo-esquelética, devendo-se sobretudo à existência de pontos gatilho (PG) miofasciais. O PG no músculo trapézio superior (TS), sob a sua forma latente, tem repercussões no equilíbrio muscular do complexo articular do ombro. A intervenção sobre este PG, através da compressão isquémica poderá ter benefícios no próprio músculo e no controlo motor do complexo articular do ombro. Objetivos: Pretende-se estudar a influência da intervenção no PG latente do músculo TS no controlo motor do ombro, analisando as alterações ao nível do timing de ativação muscular, das sequências em que o músculos ativam e do nível de atividade muscular ao longo do movimento. Métodos: Foi realizado um estudo do tipo experimental, aleatório e controlado com uma amostra dividida em dois grupos, grupo experimental (n=15) e grupo controlo (n=14). No grupo experimental foi realizada a técnica de compressão isquémica no PG do TS e no grupo controlo um procedimento placebo. Antes e após a intervenção foi recolhida a atividade eletromiográfica dos músculos grande dentado (GD), infra-espinhoso (IE), deltóide médio (DM), trapézio superior (TS) e trapézio inferior (TI), assim como os dados cinemáticos, durante o movimento de elevação do ombro no plano da omoplata. Foi analisado o timing de ativação muscular, as sequências de ativação e o nível de ativação muscular ao longo do arco de movimento, através da magnitude normalizada à contração muscular voluntária máxima. Resultados: Foi observada uma maior pré ativação do músculo GD, no grupo experimental após a intervenção (p=0,025) relativamente ao primeiro momento de avaliação. É de notar que após a intervenção, no GE, todos os músculos passaram a ativar no período típico dos ajustes posturais antecipatórios, não tendo o mesmo sido observado no grupo de controlo. Após a técnica, 37% dos indivíduos do grupo experimental passaram a ativar o GD em primeiro lugar, quando apenas um sujeito o fazia antes da intervenção. Destaca-se também um predomínio de 32% nas últimas posições, após a técnica, dos músculos trapézio superior e inferior. No GC não se verifica nenhuma tendência após a intervenção. Foram ainda observadas diferenças estatisticamente significativas entre os grupos nos arcos de movimento onde foi atingido 20% da contração isométrica voluntária máxima (CMVI) nos músculos DM (p=0,002), na primeira avaliação, e IE (p=0,021), após a intervenção, com um atraso da ativação do IE para valores superiores a 20% da CMVI. Conclusão: A compressão isquémica reflete-se na antecipação da atividade do músculo GD e num atraso do aumento da magnitude da atividade do IE para valores moderados,
Resumo:
Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Doutor em História, especialidade em Arqueologia
Resumo:
RESUMO: Introdução - A utilização de células e das suas propriedades para o tratamento das doenças cardiovasculares, é uma promessa para o futuro e talvez a única forma de ultrapassar algumas das insuficiências das terapêuticas atuais. A via de entrega das células mais utilizada na investigação tem sido a intracoronária, ganhando a microcirculação especial relevância, por ser onde ocorre a primeira interação com o tecido nativo. As células estaminais mesenquimais (CEM) têm propriedades que as tornam particularmente aptas para a Terapia Celular, mas as suas dimensões, superiores ao diâmetro dos capilares, tem motivado controvérsia quanto à sua entrega intracoronária. A cardiologia de intervenção tem atualmente técnicas que permitem a avaliação em tempo real e in vivo do estado da microcirculação coronária. A determinação do índice da resistência da microcirculação (IRM) fornece informação sobre a circulação dos pequenos vasos, de forma independente da circulação coronária e do estado hemodinâmico, mas a aplicabilidade clínica deste conhecimento encontra-se ainda por definir. Objectivos Esclarecer o potencial do IRM no estudo dos efeitos do transplante de CEM por via intracoronária. População e Métodos . Estudo pré-clínico com modelo animal (suíno) desenvolvido em 3 fases. Na Primeira Fase foram utilizados 8 animais saudáveis para estudar e validar a técnica de determinação de estudo da microcirculação. Efetuou-se a determinação do IRM com duas doses diferentes de papaverina para a indução da resposta hiperémica máxima (5 e 10 mg) e após a disfunção da microcirculação com injeção intracoronária de microesferas de embozene com 40 μm de diâmetro. Na Segunda Fase foram utilizados 18 animais saudáveis, randomizados em grupo controlo e grupo recetor de 30 x 106 CEM por via intracoronária. Foram avaliados de forma cega o IRM, a pressão aórtica, o fluxo coronário epicárdico e a ocorrência de alterações electrocardiográficas. Na Terceira Fase foram utilizados 18 animais, com enfarte agudo do miocárdio provocado (EAM), randomizados em grupo controlo, grupo recetor de CEM expandidas de forma convencional e grupo recetor de CEM expandidas com metodologia inovadora e de menores dimensões. Foi realizada uma exploração da dose/efeito com infusão faseada de 10 x 106, 15 x 106 e 20 x 106 CEM, com determinação do IRM, da pressão aórtica, do fluxo coronário epicárdico e da ocorrência de alterações eletrocardiográficas. Quatro semanas após a entrega das células foi novamente avaliado o IRM e foi efetuado o estudo anatomopatológico dos animais na procura de evidência de neoangiogénese e de regeneração miocárdica, ou de um efeito positivo da resposta reparadora após o enfarte. Resultados Nas 3 fases todos os animais mantiveram estabilidade hemodinâmica e eletrocardiográfica, com exceção da elevação de ST de V1-V3 verificada após a injeção das microesferas. Na Primeira Fase as duas doses de papaverina induziram uma resposta hiperémica eficaz, sem tradução com significado na determinação do IRM (variação da pressão distal de - 11,4 ± 5 e de - 10,6± 5 mmHg com as doses de 5 e 10 mg respetivamente (p=0,5). Com a injeção das microesferas o IRM teve uma elevação média de 310 ± 190 %, para um valor médio de 41,3 ± 16 U (p = 0,001). Na Segunda Fase não houve diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os dois grupos. O IRM de base foi semelhante e após a infusão intracoronária observou-se uma elevação expressiva do IRM nos animais que receberam células em comparação com o grupo controlo (8,8 U ± 1 vs. 14,2 U ± 1,8, P=0,02) e quanto ao seu valor de base (aumento de 112%, p=0,008). Na terceira Fase não houve novamente diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os três grupos. Houve uma elevação do IRM nos animais que receberam células a partir da 2ª dose (72% nas células convencionai e 108% nas células inovadoras) e que se manteve com a 3ª dose (100% nas células convencionais e 88% nas inovadoras) com significado estatístico em comparação com o grupo controlo (p=0,034 com a 2ªdose e p=0,024 com a 3ª dose). Quatro semanas após a entrega das CEM observou-se a descida do IRM nos dois grupos que receberam células, para valores sobreponíveis aos do grupo controlo e aos valores pós-EAM. Na avaliação anatomopatológica e histológica dos corações explantados não houve diferenças entre os três grupos. Conclusões O IRM permite distinguir alterações da microcirculação coronária motivadas pela entrega intracoronária de CEM, na ausência de alterações de outros parâmetros clínicos da circulação coronária utilizados em tempo real. As alterações do IRM são progressivas e passíveis de avaliar o efeito/dose, embora não tenha sido possível determinar diferenças com os dois tipos de CEM. No nosso modelo a injeção intracoronária não se associou a evidência de efeito benéfico na reparação ou regeneração miocárdica após o EAM.---------------------------- ABSTRACT: ABSTRACT Introduction The use of cells for the treatment of cardiovascular disease is a promise for the future and perhaps the only option to overcome some of the shortcomings of current therapies. The strategy for the delivery of cells most often used in current research has been the intracoronary route and due to this microcirculation gains special relevance, mainly because it is the first interaction site of transplanted cells with the native tissue. Mesenchymal stem cells (MSC) have properties that make them suitable for Cell Therapy, but its dimensions, larger than the diameter of capillaries, have prompted controversy about the safety of intracoronary delivery. The interventional cardiology currently has techniques that allow for real-time and in vivo assessment of coronary microcirculation state. The determination of the index of microcirculatory resistance index (IMR) provides information about small vessels, independently of the coronary circulation and hemodynamic status, but the clinical applicability of this knowledge is yet to be defined. Objectives To clarify the potential use of IMR in the study of the effects of MSC through intracoronary transplantation. Population and Methods Preclinical study with swine model developed in three phases. In Phase One 8 healthy animals were used to study and validate the IMR assessment in our animal model. IMR was assessed with two different doses of papaverine for inducing the maximal hyperaemic response (5 and 10 mg) and microcirculation dysfunction was achieved after intracoronary injection with embozene microspheres with 40 μm in diameter. In Phase Two we randomized 18 healthy animals divided between the control group and the one receiving 30 x 106 MSC through an intracoronary infusion. There we blindly evaluated IMR, the aortic pressure, the epicardial coronary flow and the occurrence of ECG changes. In Phase Three we used 18 animals with a provoked acute myocardial infarction (AMI), randomized into a control group, a MSC expanded conventionally receiver group and a MSC expanded with an innovative methodology receiver group. There was a stepwise infusion with doses of 10 x 106, 15 x 106 and 20 x 106 MSC with determination of IMR, the aortic pressure, the epicardial coronary flow and occurrence of electrocardiographic abnormalities. Four weeks after cell delivery we again measured the IMR and proceeded with the pathological study of animals in the search for evidence of neoangiogenesis and myocardial regeneration, or a positive effect in the reparative response following the infarction. Results All animals remained hemodynamically stable and with no electrocardiographic abnormalities, except for the ST elevation in V1-V3 observed after injection of the microspheres. In Phase One the two doses of papaverine achieved an hyperemic and effective response without significant differences in IMR (variation of the distal pressure -11.4 ± 5 and -10.6 ± 5 mmHg with the doses of 5 and 10 mg respectively (p = 0.5). With the injection of the microspheres the IMR had an average increase of 310 ± 190% for an average value of 41.3 ± 16 U (p = 0.001). In the second phase there were no significant differences in hemodynamic parameters, epicardial flow and electrocardiographic assessment between the two groups. The baseline IMR was similar and after intracoronary infusion there was a significant increase in animals receiving cells compared with the control group (8.8 ± U 1 vs. 14.2 ± 1.8, p = 0.02) and with their baseline (112% increase, p = 0.008). In the third phase again there were no significant differences in hemodynamic parameters, the epicardial flow and electrocardiographic evaluation between the three groups. There was a significant increase in IMR in animals that received cells from the 2nd dose (72% in conventional cells and 108% in the innovative cells) that remained with the 3rd dose (100% in conventional cells and 88% in the innovative) with statistical significance compared with the control group (p = 0.034 with 2nd dose, p = 0.024 with 3rd dose). Four weeks after delivery of the MSC we observed the fall of the IMR in the two groups that received cells with values overlapping those of the control group. In pathological and histological evaluation of removed hearts there were no differences among the three groups. Conclusions The IMR allows for the differentiation of changes in coronary microcirculation motivated by intracoronary delivery of MSC in the absence of modification in other clinical parameters. IMR changes are progressive and enable the evaluation of the effect / dose, though it has not been possible to determine differences in the two types of MSC. In our model, intracoronary injection of MSC was not associated with evidence of repair or myocardial regeneration after AMI.
Resumo:
La asfixia perinatal es una condición grave que afecta un porcentaje importante de neonatos. Su diagnostico puede dificultarse requiriendo la aplicación de pruebas altamente confiables. La investigación de novedosas formas para su diagnostico es una prioridad por las implicaciones que tiene para el neonato. El presente trabajo evalúa la capacidad diagnostica de TPN 1 y CPK MB en la detección temprana del compromiso miocárdico por asfixia en neonatos que ingresaron a la unidad de cuidado intensivo con sospecha de compromiso asfíctico durante el trabajo de parto o el parto Metodología: Se realizo un estudio de pruebas diagnosticas en 68 neonatos asfixiados, nacidos en la Clínica Materno Infantil SaludCoop que cumplieron con criterios de asfixia al nacer; Se compararon los niveles de CPK-MB y Troponina 1 tomados a las 24 horas del nacimiento, con los parámetros de evaluación de compromiso miocárdico clínicos y ecocardiográficos. Resultados: La sensibilidad de la CPK-MB y la Troponina 1 para el diagnóstico de disfunción miocárdica fue 83,3% con una especificidad de 91,9%, permitiendo inferir la potencial utilidad de su aplicación en escenarios donde la ecocardiografía fetal no es accequible. Discusión: Es posible incluir muestras bioquímicas marcadoras de disfunción miocárdica en el protocolo de manejo de neonatos con sospecha de asfixia que ingresan a la unidad de cuidado intensivo. El espectro de alteraciones observadas en un neonato asfixiado hacen que la valoración de la lesión cardiaca como órgano blanco tenga importantes repercusiones en la precisión del diagnostico, la aproximación al manejo y el establecimiento del pronóstico. Palabras Clave: Disfunción cardíaca, troponina 1, CPK MB, neonatos, asfixia perinatal, ecocardiografía neonatal, disfunción cardiaca, mortalidad
Resumo:
Introducción: La enfermedad coronaria es la principal causa de muerte en Colombia y el mundo en personas mayores de 45 años (1, 2). Con la variación en los perfiles epidemiológicos se espera que aumente su prevalencia y costo, disminuyendo la mortalidad. En el estudio diagnóstico de enfermedad coronaria, se realizan múltiples pruebas paraclínicas, dentro de estas, el ecocardiograma es muy utilizado y sus recomendaciones de uso se basan en estudios de hace más de 10 años (3). Metodología: Se realizó un estudio de prueba diagnóstica para determinar las características operativas del ecocardiograma transtorácico para el diagnóstico de enfermedad coronaria frente al cateterismo cardiaco en pacientes con dolor torácico. Resultados: Se analizaron 290 pacientes con una edad promedio de 67 años y 68% hombres; el 74.1% tenía hipertensión arterial y el 24.5% de diabetes mellitus. En el 61% de los pacientes se evidenció enfermedad coronaria por angiografía. La sensibilidad del ecocardiograma transtorácico para enfermedad coronaria fue del 70%, especificidad del 55%, valor predictivo negativo del 54% y valor predictivo positivo del 71%; con una efectividad del 65% y una capacidad predictora del 60.6% (p=0.02). Discusión: La anatomía coronaria fue similar a la descrita previamente, siendo las lesiones multivaso presente en un 41% y la lesión de un vaso fue del 22% (4, 5). Teniendo en cuenta la sensibilidad del 70% y especificidad del 55%, la facilidad de acceso, características no invasivas y el bajo costo; nos permiten recomendar utilizarlo como guía diagnóstica en el contexto del dolor torácico en el servicio de urgencias.
Resumo:
OBJETIVOS: Describir y comparar los cambios dinámicos de la geometría del anillo mitral durante todo el ciclo cardiaco en pacientes con insuficiencia mitral isquémica y pacientes con válvula mitral normal. MATERIALES Y MÉTODOS: Los estudios ecocardiográficos analizados fueron 37, 23 con insuficiencia mitral isquémica y 14 con válvula mitral normal. La reconstrucción del anillo se realizó en la estación de trabajo Xcelera (Philips Medial Systems) mediante la herramienta de análisis mitral (MVQ), en 5 momentos del ciclo cardiaco: Comienzo de Sístole, Mitad de Sístole, Final de Sístole, Mitad de Diástole y Final de Diástole. RESULTADOS: El anillo del grupo control, fue más dinámico, con sus menores dimensiones al final de la diástole, presentando incremento progresivo durante la sístole. Los cambios en el perímetro y el área, fueron significativos entre el comienzo y mitad de la sístole (p:0.087 y p: 0.055). En el grupo con insuficiencia mitral isquémica, el anillo fue más estático. Todas las dimensiones en este grupo, fueron mayores en los cinco momentos del ciclo cardiaco. (p < 0.1). El anillo también fue más plano, con un índice morfológico anular menor al del grupo control (p:0.087). DISCUSIÓN Y CONCLUSIONES: En pacientes sin insuficiencia mitral, el anillo es una estructura dinámica. Durante la sístole, las menores dimensiones se produjeron al comienzo de este periodo y la conformación en silla de montar se mantuvo, protegiendo contra la insuficiencia mitral. El anillo del grupo con insuficiencia mitral fue más estático y plano, perdiendo los mecanismos protectores.
Resumo:
Objetivo: Caracterizar a los pacientes que recibieron ventilación mecánica en las unidades de cuidado intensivo (UCI) de la Fundación Santa Fe de Bogotá entre los años 2009 y 2013. Metodología: Se analizó una cohorte retrospectiva de los pacientes en UCI que requirieron soporte ventilatorio mecánico al ingreso a la unidad independientemente de la causa. Resultados: La media de edad de los pacientes fue 63,83 años; el diagnóstico más frecuente de ingreso fue revascularización miocárdica, seguido por neumonía y recambio valvular aórtico; en el 43% de los casos la causa de la falla fue el estado postoperatorio. Los modos ventilatorios más frecuentemente utilizados fueron SIMV (27,5%) y ventilación asistida controlada (26,12%). El 50% de los pacientes fueron ventilados con PEEP < 6 cmH2O. La mortalidad bruta fue del 15%. 22% de los pacientes tuvieron estancia prolongada en UCI. Se aplicó protocolo de retiro de ventilación mecánica en el 77% de los pacientes. La duración de la ventilación mecánica es mayor a medida que aumenta la edad del paciente entre los 60 y los 80 años. La mortalidad es cercana al 50% alrededor de los 50 años y mayor a 80% después de los 80 años. El soporte ventilatorio por cinco o más días aumentó la mortalidad a 80% o más. Discusión y Conclusiones: Estos resultados son comparables a los encontrados en estudios previos. Este estudio puede ser considerado como el primer paso para generar un registro adecuado de la ventilación de la mecánica de las unidades de cuidado intensivo del país.
Resumo:
Introducción: Las enfermedades cardiovasculares son la causa de muerte más frecuente en el mundo desarrollado, la mayoría de éstas se relacionan con alteraciones de las arterias coronarias, sin embargo un subgrupo de pacientes presentan como causa de isquemia cardiaca alteraciones estructurales. Material y métodos: Estudio Descriptivo. Se utilizó la base de datos recolectada en un servicio de hemodinamia de Bogotá durante dos años. Se aplicaron criterios de inclusión y exclusión y se determinaron cuatro grupos etáreos, a todos los pacientes se les practicó cateterismo cardiaco diagnóstico. Las variables analizadas fueron: diagnóstico de referencia, antecedentes y resultados del cateterismo incluyendo presencia de anomalías estructurales como las valvulopatias, el origen anómalo de las coronarias y los puentes miocárdicos. Para el análisis descriptivo se utilizó reporte de prevalencias y para el análisis de asociaciones se utilizaron tablas de contingencia y el estadístico de prueba Chi cuadrado, no se realizó análisis multivariado debido a que no se encontraron asociaciones estadísticamente significativas. Resultados: La edad promedio de los pacientes fue de 62 años (DS= 10,5), la representación del género masculino fue del 61,7%, la prevalencia de angina estable fue del 61,6%, los 3 antecedentes más prevalentes fueron: hipertensión arterial (41,4%), la hiperlipidemia (19,1%) y la Diabetes Mellitus (17,7%). La prevalencia de las alteraciones estructurales en la población de estudio de manera general fue del 12,9%, y su distribución por tipo fue: 1,4% para puentes miocárdicos, 0,7% para origen anómalo de las arterias coronarias y 10,8% de enfermedad valvular. Conclusiones: Se encontró una asociación entre los antecedentes médicos y la presencia de valvulopatias cardiacas. Se evidenció que el género no tiene relación con la presencia de alteraciones cardíacas a pesar de la mayor participación de hombres en la población de estudio. Las limitantes de este estudio se relacionaron con el tamaño de muestra, debido a la baja prevalencia de las anomalías estructurales medidas.
Resumo:
Introducción: La disminución de flujo en los vasos coronarios sin presencia de oclusión, es conocido como fenómeno de no reflujo, se observa después de la reperfusión, su presentación oscila entre el 5% y el 50% dependiendo de la población y de los criterios diagnósticos, dicho suceso es de mal pronóstico, aumenta el riesgo de morir en los primeros 30 días posterior a la angioplastia (RR 2,1 p 0,038), y se relaciona con falla cardiaca y arritmias, por eso al identificar los factores a los cuales se asocia, se podrán implementar terapias preventivas. Metodología: Estudio de casos y controles pareado por médico que valoró el evento, para garantizar que no existieron variaciones inter observador, con una razón 1:4 (18:72), realizado para identificar factores asociados a la presencia de no reflujo en pacientes llevados a angioplastia, entre noviembre de 2010 y mayo de 2014, en la Clínica San Rafael de Bogotá, D.C. Resultados: La frecuencia del no reflujo fue del 2.89%. El Infarto Agudo de Miocardio con elevación del ST (IAMCEST) fue la única variable que mostró una asociación estadísticamente significativa con este suceso, valor de p 0,002, OR 8,7, IC 95% (2,0 – 36,7). Discusión: El fenómeno de no reflujo en esta población se comportó de manera similar a lo descrito en la literatura, siendo el IAMCEST un factor fuertemente asociado.
Resumo:
Se realizó un estudio transversal, se incluyeron 3 residentes no cardiólogos y se les dio formación básica en ecocardiografía (horas teóricas 22, horas prácticas 65), con recomendaciones de la Sociedad Americana de Ecocardiografia y aportes del aprendizaje basado en problemas, con el desarrollo de competencia técnicas y diagnósticas necesarias, se realizó el análisis de concordancia entre residentes y ecocardiografistas expertos, se recolectaron 122 pacientes hospitalizados que cumplieran con los criterios de inclusión y exclusión, se les realizo un ecocardiograma convencional por el experto y una valoración ecocardiográfica por el residente, se evaluó la ventana acústica, contractilidad, función del ventrículo izquierdo y derrame pericárdico. La hipótesis planteada fue obtener una concordancia moderada. Resultados: Se analizó la concordancia entre observadores para la contractilidad miocárdica (Kappa: 0,57 p=0,000), función sistólica del ventrículo izquierdo (Kappa 0,54 p=0.000) siendo esta moderada por estar entre 0,40 – 0,60 y con una alta significancia estadística, para la calidad de la ventana acústica (Kappa: 0,22 p= 0.000) y presencia de derrame pericárdico (Kappa: 0,26 p= 0.000) se encontró una escasa concordancia ubicándose entre 0,20 – 0,40. Se estableció una sensibilidad de 90%, especificidad de 67%, un valor predictivo positivo de 80% y un valor predictivo negativo de 85% para el diagnóstico de disfunción sistólica del ventrículo izquierdo realizado por los residentes.