981 resultados para Concrete-Filled steel tubular columns
Resumo:
This paper presents the results from an experimental program and an analytical assessment of the influence of addition of fibers on mechanical properties of concrete. Models derived based on the regression analysis of 60 test data for various mechanical properties of steel fiber-reinforced concrete have been presented. The various strength properties studied are cube and cylinder compressive strength, split tensile strength, modulus of rupture and postcracking performance, modulus of elasticity, Poisson’s ratio, and strain corresponding to peak compressive stress. The variables considered are grade of concrete, namely, normal strength 35 MPa , moderately high strength 65 MPa , and high-strength concrete 85 MPa , and the volume fraction of the fiber Vf =0.0, 0.5, 1.0, and 1.5% . The strength of steel fiber-reinforced concrete predicted using the proposed models have been compared with the test data from the present study and with various other test data reported in the literature. The proposed model predicted the test data quite accurately. The study indicates that the fiber matrix interaction contributes significantly to enhancement of mechanical properties caused by the introduction of fibers, which is at variance with both existing models and formulations based on the law of mixtures
Resumo:
This paper presents an experimental research on the use of eddy current testing (ECT) and artificial neural networks (ANNs) in order to identify the gauge and position of steel bars immersed in concrete structures. The paper presents details of the ECT probe and concrete specimens constructed for the tests, and a study about the influence of the concrete on the values of measured voltages. After this, new measurements were done with a greater number of specimens, simulating a field condition and the results were used to generate training and validation vectors for multilayer perceptron ANNs. The results show a high percentage of correct identification with respect to both, the gauge of the bar and of the thickness of the concrete cover. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
This paper shows the results of an experimental investigation carried out on a connection element of glulam and concrete composite structures, through double-sided push-out shear tests. The connection system was composed of perforated steel plates glued with epoxy adhesive. Five specimens were made and tested under shear forces. This innovative connection system showed an average initial slip modulus equivalent to 339.4 kN/mm. In addition, the connection system was evaluated by means of numerical simulations and the software ANSYS was used for this purpose. The numerical simulations demonstrated good agreement with the experimental data, especially in the regime of elastic-linear behavior of materials. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This paper is part of an extensive work about the technological development, experimental analysis and numerical modeling of steel fibre reinforced concrete pipes. The first part ("Steel fibre reinforced concrete pipes. Part 1: technological analysis of the mechanical behavior") dealt with the technological development of the experimental campaign, the test procedure and the discussion of the structural behavior obtained for each of the dosages of fibre used. This second part deals with the aspects of numerical modeling. In this respect, a numerical model called MAP, which simulates the behavior of fibre reinforced concrete pipes with medium-low range diameters, is introduced. The bases of the numerical model are also mentioned. Subsequently, the experimental results are contrasted with those produced by the numerical model, obtaining excellent correlations. It was possible to conclude that the numerical model is a useful tool for the design of this type of pipes, which represents an important step forward to establish the structural fibres as reinforcement for concrete pipes. Finally, the design for the optimal amount of fibres for a pipe with a diameter of 400 mm is presented as an illustrating example with strategic interest.
Resumo:
It is well recognized that the technique of strengthening reinforced concrete (RC) using fiber-reinforced polymer (FRP) jackets is more effective for circular sections, but less effective for rectangular sections. Indeed the presence of angular corners does not permit a uniform confinement to be provided by the FRP jackets to the columns. While rounded corners can enhance the effectiveness of FRP confinement, it will be more efficient to modify the rectangular section into an elliptical section. In addition to the better confinement effectiveness, from an aesthetical point of view, the shape modification would be a surprise to the built environment. This paper presents an experimental study on the behavior of FRP-confined concrete columns with elliptical section. Thirty-two short columns, divided in eight batches, were tested under axial compression. Each batch presents four specimens with different elliptical sections, determined by the aspect ratio a/b, that is the ratio between the minor and mayor axis. By varying this value from 1.0 to 2.0 (1.0, 1.3., 1.7, 2.0), the section becomes more and more elliptical starting from a circular shape. In this way it is possible to study the trend of effectiveness of FRP confinement for different section geometries. It is also interesting to study how the confinement effectiveness may vary by changing the cylinder strength of concrete and the number of the layers of CFRP. For this reason, a cylinder strength of concrete of 25 and 45 MPa have been used for the present research work, and half of the specimens were wrapped by one layer of CFRP, while the remaining specimens were wrapped with two layers. A simple analysis of the results has been carried out for evaluating the experimental work described in the present document. Further studies and analysis on this work should help to achieve a new and more accurate stress-strain model for CFRP-confined concrete columns with an elliptical section.
Resumo:
Experimental study on the long-term deformations of the fibre reinforced concrete. Steel and macro-synthetic fibers were used to evaluate the shrinkage, creep, mid-span deflection, cracking and rupture analysis of three different types of samples. At the end the main topics of ACI guidelines were analyzed in order to perform an overview of design.
Resumo:
Ultra-high performance fiber reinforced concrete (UHPFRC) has arisen from the implementation of a variety of concrete engineering and materials science concepts developed over the last century. This material offers superior strength, serviceability, and durability over its conventional counterparts. One of the most important differences for UHPFRC over other concrete materials is its ability to resist fracture through the use of randomly dispersed discontinuous fibers and improvements to the fiber-matrix bond. Of particular interest is the materials ability to achieve higher loads after first crack, as well as its high fracture toughness. In this research, a study of the fracture behavior of UHPFRC with steel fibers was conducted to look at the effect of several parameters related to the fracture behavior and to develop a fracture model based on a non-linear curve fit of the data. To determine this, a series of three-point bending tests were performed on various single edge notched prisms (SENPs). Compression tests were also performed for quality assurance. Testing was conducted on specimens of different cross-sections, span/depth (S/D) ratios, curing regimes, ages, and fiber contents. By comparing the results from prisms of different sizes this study examines the weakening mechanism due to the size effect. Furthermore, by employing the concept of fracture energy it was possible to obtain a comparison of the fracture toughness and ductility. The model was determined based on a fit to P-w fracture curves, which was cross referenced for comparability to the results. Once obtained the model was then compared to the models proposed by the AFGC in the 2003 and to the ACI 544 model for conventional fiber reinforced concretes.
Resumo:
En este trabajo se presentan los diagramas tensióndeformación de un nuevo acero inoxidable con bajo contenido en níquel, un inoxidable convencional AISI 304 y un acero al carbono de uso común en estructuras de hormigón armado. Dicha ductilidad se ha estudiado determinando la tensión máxima (fmax), la tensión en el límite elástico (fy) y la deformación bajo carga máxima (εmax). Los tres materiales se han evaluado utilizando criterios aceptados internacionalmente, como son el índice p (capacidad de rotación plástica), el índice A* (área plástica de endurecimiento) y el índice de tenacidad Id (energía total absorbida en el punto de alargamiento bajo carga máxima), los resultados obtenidos se han comparado con los aceros convencionales de armaduras 500SD, 500N y 500H (EC-2).
Resumo:
The use of reinforcing stainless steels (SS) in concrete have proved to be one of the most effective methods to guarantee the passivity of reinforced concrete structures exposed to chloride contaminated environment. The present research studies the corrosion behaviour of a new duplex SS reinforcements with low nickel content (LND) (more economicaly compatible) is compared with the conventional austenitic AISI 304 SS and duplex AISI 2304 SS. Corrosion behaviour of ribbed SS reinforcements was studied in mortars with chloride content (0, 0.4, 2 and 4% Cl ⎯ ) using linear polarization resistance and potentiostatic pulses technique, Ecorr and Rp values were monitored over the exposure time. The obtained icorr data for the new duplex stainless steel LND no afforded passivity breakdown after one year exposure
Resumo:
In the present work a seismic retrofitting technique is proposed for masonry infilled reinforced concrete frames based on the replacement of infill panels by K-bracing with vertical shear link. The performance of this technique is evaluated through experimental tests. A simplified numerical model for structural damage evaluation is also formulated according to the notions and principles of continuum damage mechanics. The proposed model is calibrated with the experimental results. The experimental results have shown an excellent energy dissipation capacity with the proposed technique. Likewise, the numerical predictions with the proposed model are in good agreement with experimental results.
Resumo:
As part of the IRIS_2012 international benchmark, simulations were conducted to analyse impacts on reinforced concrete slabs by both rigid and deformable missiles. The analytical results were compared with physical tests conducted by the Technical Research Center VTT of Finland. In the impact discussed here, a rigid missile perforates the concrete slab. The missile is a thick steel tube filled with concrete with a total mass of 47.4 kg and strikes the target at 136 m/s. The target is a 250 mm thick, reinforced concrete slab that spans 2 m by 2 m and is held in a rigid supporting frame. Characterisation tests were provided for calibration of the parameters of the concrete models selected by the participants. Having reproduced those tests, the authors developed models for the slab and the missile. A damaged plasticity model was used for the concrete and the rebars were explicitly represented. The results obtained were very satisfactory in respect of the damage patterns caused in the concrete and the reinforcement; also, the calculated and measured values of the energy spent by the missile in perforating the slab differed by only 4%.
Resumo:
In this work, cracking of concrete due to steel reinforcement corrosion is experimentally and numerically studied. The tests combined accelerated corrosion—to generate the cracks—with impregnation under vacuum with resin containing fluorescein—to enhance their visibility under ultraviolet light. In parallel, a model—called expansive joint element—was developed to simulate the expansion of the oxide and finite elements with an embedded adaptable cohesive crack were used to describe concrete cracking. The results show that a good agreement exists between the experimental and numerical crack patterns, which constitutes promising progress towards a comprehensive understanding of corrosion-induced cracking in reinforced concrete.
Resumo:
Corrosion can affect the bond between reinforcing bars and concrete and hence the transfer of longitudinal stresses. Although a number of experimental studies on bond failure have been conducted in recent years, the findings have diverged rather widely, due primarily to differing test conditions. The present paper reports on an experimental programme consisting of eccentric pull-out tests run on corroded steel bars in specimens subjected to accelerated or natural corrosion. An axisymmetric bi-dimensional FE model with finite deformations initially developed to study bond mechanics with sound steel bars, has been enhanced to consider bond effects in corroded steel bars. The model simulation is compared to some of the experimental results for corroded and sound bars and the findings are analysed.
Resumo:
The study brings new insights on the hydrogen assisted stress corrosion on damage tolerance of a high-strength duplex stainless steel wire which concerns its potential use as active reinforcement for concrete prestressing. The adopted procedure was to experimentally state the effect of hydrogen on the damage tolerance of cylindrical smooth and precracked wire specimens exposed to stress corrosion cracking using the aggressive medium of the standard test developed by FIP (International Prestressing Federation). Stress corrosion testing, mechanical fracture tests and scanning electron microscopy analysis allowed the damage assessment, and explain the synergy between mechanical loading and environment action on the failure sequence of the wire. In presence of previous damage, hydrogen affects the wire behavior in a qualitative sense, consistently to the fracture anisotropy attributable to cold drawing, but it does not produce quantitative changes since the steel fully preserves its damage tolerance.
Resumo:
A significant amount of research has been conducted on FRP-confined circular columns, but much less is known about rectangular/square columns in which the effectiveness of confinement is much reduced. This paper presents the results of experimental investigations on low strength square concrete columns confined with FRP. Axial compression tests were performed on ten intermediate size columns. The tests results indicate that FRP composites can significantly improve the bearing capacity and ductility of square section reinforced concrete columns with rounded corners. The strength enhancement ratio is greater the lower the concrete strength and also increases with the stiffness of the jacket. The confined concrete behaviour was predicted according to the more accepted theoretical models and compared with experimental results. There are two key parameters which critically influence the fitting of the models: the strain efficiency factor and the effect of confinement in non-circular sections.