979 resultados para Computed Tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multidetector row computed tomography over the last decade is commonly used in veterinary medicine. This new technology has an increased spatial and temporal resolution, could evaluate wider scanning range in shorter scanning time, providing an advanced imaging modality. Computed tomography angiographic studies are commonly used in veterinary medicine in order to evaluate vascular structures of the abdomen and the thorax. Pulmonary pathology in feline patients is a very common condition and usually is further evaluating with computed tomography. Up to date few references of the normal computed tomographic aspects of the feline thorax are reported. In this study a computed tomographic pulmonary angiography (CTPA) protocol is reported in normal cats and is compared with the up to date anatomical references. A CTPA protocol using a 64 MDCT in our study achieved high resolution images of the pulmonary arteries, pulmonary veins and bronchial lumen till the level of minor segmental branches. Feline pulmonary bronchial parenchyma demonstrates an architecture of mixed type with a monopedial model observed in the most anatomical parts and the dichotomic aspect is seen at the accessory lobe. The arterial and venous architecture is similar to the bronchial. Statistical analysis demonstrates the linear correlation of tracheal diameter to the felines weight. Vascular variations were noticed. The pulmonary venous system enters into the left atrium through three ostia (left cranial ostia: consisted of the anastomosis of the cranial and caudal portion of the left cranial pulmonary vein; right ostia: consisted of the anastomosis of the right cranial and middle pulmonary vein; and the caudal ostia: consisted of the anastomosis of the right and left caudal pulmonary vein). In conclusion CTPA is applicable in feline patients and provides an excellent imaging of the pulmonary arterial, venous and bronchial system till the level of minor segmental branches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo studio ci siamo proposti di investigare i sistemi di modulazione automatica della dose sui sistemi TC Multislice (Automatic Exposure Control – AEC) da tre diversi produttori, aventi differenti indicatori di qualità delle immagini. Il presente lavoro è stato svolto presso il Servizio di Fisica Sanitaria dell’Azienda Ospedaliera Universitaria - Policlinico Sant’Orsola-Malpighi di Bologna e consiste in un’analisi quantitativa della dose impiegata durante esami di Tomografia Computerizzata Multi-Slice (TCMS) e delle rispettive immagini radiologiche. Le immagini sono state acquisite con : GE LightSpeed VCT 64 e GE LightSpeed 16 (AEC AutomA 3D longitudinale e angolare), Siemens Sensation 16 (AEC CARE Dose 4D combinato), Philips Brilliance 16 e iCT 64 (separati in AEC ZDOM longitudinale e AEC DDOM angolare). Le acquisizioni TCMS sono state effettuate a differenti kV e mA di riferimento, al fine di investigarne gli effetti sulla modulazione, impiegando algoritmi di ricostruzione standard presenti su ogni macchina. Due fantocci antropomorfi simulanti la zona del torace e dell’addome sono stati utilizzati per simulare un paziente standard posizionato come in un esame clinico di routine ; a questo proposito, sono stati impiegati protocolli elicoidali standard con e senza modulazione. Sono inoltre stati testati differenti valori di indice di qualità delle immagini. Il profilo dei mA lungo la lunghezza è stato ottenuto utilizzando ImageJ, un programma open source comunemente utilizzato per l’elaborazione di immagini; i mAs sono stati normalizzati ad un fattore che tiene conto delle differenti geometrie e delle filtrazioni dei diversi scanner tomografici analizzati nell’esperienza. Il rumore è stato valutato tramite la scelta di determinate ROI (Region Of Interest) localizzate in aree il più possibili uniformi disponibili lungo i fantocci. Abbiamo registrato che una variazione del Noise Index o dei mAs di riferimento a seconda della tipologia di macchina analizzata risulta in uno shift dei profili di dose; lo stesso si è verificato quando sono stati cambiato kV o mA nella scout di acquisizione. Sistemi AEC longitudinali e combinati hanno mostrato profili di mAs normalizzati simili tra loro, con valori elevati evidenziati nella zona delle spalle e zona pelvi; sono state osservate differenze del 30-40% tra i differenti scanner tomografici. Solo in un caso di macchina analizzata si è verificato un comportamento opposto rispetto alle altre due tipologie di macchina in esame. A dispetto della differente natura dei sistemi AEC, i risultati ottenuti dai protocolli combinati e longitudinali sono simili tra loro. Il rumore presente nelle immagini è aumentato ad un livello accettabile e la sua uniformità lungo la direzione di scan è migliorata.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In der Erdöl– und Gasindustrie sind bildgebende Verfahren und Simulationen auf der Porenskala im Begriff Routineanwendungen zu werden. Ihr weiteres Potential lässt sich im Umweltbereich anwenden, wie z.B. für den Transport und Verbleib von Schadstoffen im Untergrund, die Speicherung von Kohlendioxid und dem natürlichen Abbau von Schadstoffen in Böden. Mit der Röntgen-Computertomografie (XCT) steht ein zerstörungsfreies 3D bildgebendes Verfahren zur Verfügung, das auch häufig für die Untersuchung der internen Struktur geologischer Proben herangezogen wird. Das erste Ziel dieser Dissertation war die Implementierung einer Bildverarbeitungstechnik, die die Strahlenaufhärtung der Röntgen-Computertomografie beseitigt und den Segmentierungsprozess dessen Daten vereinfacht. Das zweite Ziel dieser Arbeit untersuchte die kombinierten Effekte von Porenraumcharakteristika, Porentortuosität, sowie die Strömungssimulation und Transportmodellierung in Porenräumen mit der Gitter-Boltzmann-Methode. In einer zylindrischen geologischen Probe war die Position jeder Phase auf Grundlage der Beobachtung durch das Vorhandensein der Strahlenaufhärtung in den rekonstruierten Bildern, das eine radiale Funktion vom Probenrand zum Zentrum darstellt, extrahierbar und die unterschiedlichen Phasen ließen sich automatisch segmentieren. Weiterhin wurden Strahlungsaufhärtungeffekte von beliebig geformten Objekten durch einen Oberflächenanpassungsalgorithmus korrigiert. Die Methode der „least square support vector machine” (LSSVM) ist durch einen modularen Aufbau charakterisiert und ist sehr gut für die Erkennung und Klassifizierung von Mustern geeignet. Aus diesem Grund wurde die Methode der LSSVM als pixelbasierte Klassifikationsmethode implementiert. Dieser Algorithmus ist in der Lage komplexe geologische Proben korrekt zu klassifizieren, benötigt für den Fall aber längere Rechenzeiten, so dass mehrdimensionale Trainingsdatensätze verwendet werden müssen. Die Dynamik von den unmischbaren Phasen Luft und Wasser wird durch eine Kombination von Porenmorphologie und Gitter Boltzmann Methode für Drainage und Imbibition Prozessen in 3D Datensätzen von Böden, die durch synchrotron-basierte XCT gewonnen wurden, untersucht. Obwohl die Porenmorphologie eine einfache Methode ist Kugeln in den verfügbaren Porenraum einzupassen, kann sie dennoch die komplexe kapillare Hysterese als eine Funktion der Wassersättigung erklären. Eine Hysterese ist für den Kapillardruck und die hydraulische Leitfähigkeit beobachtet worden, welche durch die hauptsächlich verbundenen Porennetzwerke und der verfügbaren Porenraumgrößenverteilung verursacht sind. Die hydraulische Konduktivität ist eine Funktion des Wassersättigungslevels und wird mit einer makroskopischen Berechnung empirischer Modelle verglichen. Die Daten stimmen vor allem für hohe Wassersättigungen gut überein. Um die Gegenwart von Krankheitserregern im Grundwasser und Abwässern vorhersagen zu können, wurde in einem Bodenaggregat der Einfluss von Korngröße, Porengeometrie und Fluidflussgeschwindigkeit z.B. mit dem Mikroorganismus Escherichia coli studiert. Die asymmetrischen und langschweifigen Durchbruchskurven, besonders bei höheren Wassersättigungen, wurden durch dispersiven Transport aufgrund des verbundenen Porennetzwerks und durch die Heterogenität des Strömungsfeldes verursacht. Es wurde beobachtet, dass die biokolloidale Verweilzeit eine Funktion des Druckgradienten als auch der Kolloidgröße ist. Unsere Modellierungsergebnisse stimmen sehr gut mit den bereits veröffentlichten Daten überein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro di tesi è stato svolto presso il servizio di Fisica Sanitaria del Policlinico Sant'Orsola-Malpighi di Bologna. Lo studio si è concentrato sul confronto tra le tecniche di ricostruzione standard (Filtered Back Projection, FBP) e quelle iterative in Tomografia Computerizzata. Il lavoro è stato diviso in due parti: nella prima è stata analizzata la qualità delle immagini acquisite con una CT multislice (iCT 128, sistema Philips) utilizzando sia l'algoritmo FBP sia quello iterativo (nel nostro caso iDose4). Per valutare la qualità delle immagini sono stati analizzati i seguenti parametri: il Noise Power Spectrum (NPS), la Modulation Transfer Function (MTF) e il rapporto contrasto-rumore (CNR). Le prime due grandezze sono state studiate effettuando misure su un fantoccio fornito dalla ditta costruttrice, che simulava la parte body e la parte head, con due cilindri di 32 e 20 cm rispettivamente. Le misure confermano la riduzione del rumore ma in maniera differente per i diversi filtri di convoluzione utilizzati. Lo studio dell'MTF invece ha rivelato che l'utilizzo delle tecniche standard e iterative non cambia la risoluzione spaziale; infatti gli andamenti ottenuti sono perfettamente identici (a parte le differenze intrinseche nei filtri di convoluzione), a differenza di quanto dichiarato dalla ditta. Per l'analisi del CNR sono stati utilizzati due fantocci; il primo, chiamato Catphan 600 è il fantoccio utilizzato per caratterizzare i sistemi CT. Il secondo, chiamato Cirs 061 ha al suo interno degli inserti che simulano la presenza di lesioni con densità tipiche del distretto addominale. Lo studio effettuato ha evidenziato che, per entrambi i fantocci, il rapporto contrasto-rumore aumenta se si utilizza la tecnica di ricostruzione iterativa. La seconda parte del lavoro di tesi è stata quella di effettuare una valutazione della riduzione della dose prendendo in considerazione diversi protocolli utilizzati nella pratica clinica, si sono analizzati un alto numero di esami e si sono calcolati i valori medi di CTDI e DLP su un campione di esame con FBP e con iDose4. I risultati mostrano che i valori ricavati con l'utilizzo dell'algoritmo iterativo sono al di sotto dei valori DLR nazionali di riferimento e di quelli che non usano i sistemi iterativi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In addition to the increasingly significant role of multislice computed tomography in forensic pathology, the performance of whole-body computed tomography angiography provides outstanding results. In this case, we were able to detect multiple injuries of the parenchymal organs in the upper abdomen as well as lesions of the brain parenchyma and vasculature of the neck. The radiologic findings showed complete concordance with the autopsy and even supplemented the autopsy findings in areas that are difficult to access via a manual dissection (such as the vasculature of the neck). This case shows how minimally invasive computed tomography angiography can serve as an invaluable adjunct to the classic autopsy procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To report our initial experience with dual-energy computed-tomography (CT) cholangiography in potential donors for living-related liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements. MATERIAL AND METHODS: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses. RESULTS: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible. CONCLUSIONS: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyze the dimensions and anatomic characteristics of the nasopalatine canal and the corresponding buccal bone plate of the alveolar process, using limited cone-beam computed tomography (CBCT) imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although postmortem imaging has gained prominence in the field of forensic medicine, evaluation of the postmortem lung remains problematic. Specifically, differentiation of normal postmortem changes and pathological pulmonary changes is challenging and at times impossible. In this study, five corpses were ventilated using a mechanical ventilator with a pressure of 40 mbar (40.8 cm H(2)O). The ventilation was performed via an endotracheal tube, a larynx mask or a continuous positive airway pressure mask. Postmortem computed tomographic images of the lungs before and with a ventilation of 40 mbar (40.8 cm H(2)O) were evaluated and the lung volumes were measured with segmentation software. Postmortem ventilation led to a clearly visible decrease of both the density in the dependant parts of the lungs and ground glass attenuation, whereas consolidated areas remained unchanged. Furthermore, a mean increase in the lung volume of 2.10 l was seen. Pathological changes such as septal thickening or pulmonary nodules in the lung parenchyma became more detectable with postmortem ventilation. Intracorporal postmortem mechanical ventilation of the lungs appears to be an effective method for enhancing detection of small pathologies of the lung parenchyma as well as for discriminating between consolidation, ground glass attenuation and position-dependent density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood aspiration is a significant forensic finding. In this study, we examined the value of postmortem computed tomography (CT) imaging in evaluating findings of blood aspiration. We selected 37 cases with autopsy evidence of blood in the lungs and/or in the airways previously submitted to total-body CT scanning. The CT-images were retrospectively analyzed. In one case with pulmonary blood aspiration, biopsy specimens were obtained under CT guide for histological examination. In six cases, CT detected pulmonary abnormalities suggestive of blood aspiration, not mentioned in the autopsy reports. CT reconstructions provided additional data about the distribution and extent of aspiration. In one needle-biopsied case, the pulmonary specimens showed blood in the alveoli. We suggest the use of CT imaging as a tool complementary to traditional techniques in cases of blood aspiration to avoid misdiagnosis, to guide the investigation of lung tissue, and to allow for more evidence-based inferences on the cause of death.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As an Alpine country, Switzerland has not only a thriving mountaineering tourist industry, but also many mountaineering casualties. At the request of the state attorney, most of the victims undergo only an external inspection without autopsy. One of the main tasks of the forensic pathologist under these circumstances is the correct identification of the deceased for a fast release to their kin. Nevertheless, detailed knowledge of the injuries sustained may lead to improved safety measures, such as better protective equipment. In this study, we examined the feasibility of using cross-sectional imaging with postmortem multi-slice computed tomography (MSCT) to detect lesions of the skeletal structures and internal organs. For this purpose, we used whole-body MSCT to examine 10 corpses that suffered fatal falls from great height while climbing in the Swiss part of the European Alps from the years 2007 to 2009. We conclude that postmortem CT imaging is a valuable tool for dental identification and is superior to plain X-rays as a viable compromise between a solely external legal inspection and an autopsy because it delivers otherwise irretrievable additional internal findings non-invasively. This fact is of great importance in cases where an autopsy is refused.