916 resultados para Cannula, Ventricular assist device, Rotary blood pump, Heart failure
Resumo:
Rapport de stage présenté à la Faculté des sciences infirmières en vue de l'obtention du grade de Maître ès sciences (M.Sc.) en sciences infirmières option expertise-conseil en soins infirmiers
Resumo:
Rapport de stage présenté à la Faculté des sciences infirmières en vue de l'obtention du grade de Maître ès sciences (M.Sc.) en sciences infirmières option expertise-conseil en soins infirmiers
Resumo:
Objetivos: La mediastinitis se presenta hasta en el 4% de los pacientes sometidos a revascularización miocárdica, con un mortalidad hospitalaria reportada del 14 al 47%, generando aumento en los costos de atención, deterioro de la calidad de vida y la sobrevida a largo plazo del enfermo; su etiología es multifactorial. El objetivo de este estudio fue determinar cuáles antecedentes clínicos del paciente y factores relacionados con el procedimiento quirúrgico se asocian con la aparición mediastinitis. Métodos: Diseño de casos y controles anidado en una cohorte histórica de pacientes sometidos a revascularización miocárdica en el periodo de enero de 2005 a julio de 2011. Los pacientes con mediastinitis se compararon con un grupo control sin mediastinitis tomados del mismo grupo de riesgo en una relación 1:4, y pareados por fecha de cirugía. El diagnóstico de mediastinitis se hizo con criterios clínicos, de laboratorio y hallazgos quirúrgicos. Resultados: Se identificaron 30 casos en ese periodo. Los factores asociados a la aparición del evento fueron: Diabetes Mellitus OR 2,3 (1.1- 4,9), uso de circulación extracorpórea OR 2,4 (1,1 -5.5), tiempo de perfusión OR 1,1 (1,1 – 1.3) y pacientes mayores de 70 años OR 1.1 (1,2-1-4). Conclusiones: La mediastinitis sigue siendo una complicación de baja prevalencia con consecuencias devastadoras. El impacto clínico y económico de esta complicación debe obligar a los grupos quirúrgicos a crear estrategias de prevención con base en el conocimiento de los factores de riesgo de su población.
Resumo:
P>Many hemoglobin-derived peptides are present in mouse brain, and several of these have bioactive properties including the hemopressins, a related series of peptides that bind to cannabinoid CB1 receptors. Although hemoglobin is a major component of red blood cells, it is also present in neurons and glia. To examine whether the hemoglobin-derived peptides in brain are similar to those present in blood and heart, we used a peptidomics approach involving mass spectrometry. Many hemoglobin-derived peptides are found only in brain and not in blood, whereas all hemoglobin-derived peptides found in heart were also seen in blood. Thus, it is likely that the majority of the hemoglobin-derived peptides detected in brain are produced from brain hemoglobin and not erythrocytes. We also examined if the hemopressins and other major hemoglobin-derived peptides were regulated in the Cpefat/fat mouse; previously these mice were reported to have elevated levels of several hemoglobin-derived peptides. Many, but not all of the hemoglobin-derived peptides were elevated in several brain regions of the Cpefat/fat mouse. Taken together, these findings suggest that the post-translational processing of alpha and beta hemoglobin into the hemopressins, as well as other peptides, is up-regulated in some but not all Cpefat/fat mouse brain regions.
Resumo:
We report a case of a female patient that was referred to our service with progressive weakness and dyspnea. Three years ago, she had been submitted to hysterectomy and salpingo-oforectomy followed by adjuvant radiotherapy due to uterine cervix neuroendocrine tumor. Two-dimensional echocardiography showed a dense sessile mass in the right ventricle causing right and left ventricular filling restriction. Despite chemotherapy the patient died and necropsy confirmed metastases from neuroendocrine tumor to the right ventricle. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.
Resumo:
Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision.
Resumo:
Seromas occurring around a vascular graft are a rare complication. We report a life-threatening plasma leakage that occurred through the polytetrafluoroethylene vascular prosthesis of an Impella right ventricular assist device (Impella RD [Impella Cardiosystems GmbH, Aachen, Germany]) implanted in a 62-year-old patient with acute right ventricular failure after cardiac transplantation. The leakage became progressively massive. Weaning the patient from the right ventricular assist device was not possible. The prosthesis was thus wrapped within a pericardial patch to contain the leakage. Three days later the patient could be successfully weaned and the pump was removed. The clinical evolution was favorable.
Resumo:
Background Whole-body water immersion leads to a significant shift of blood from the periphery into the intra-thoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically in-duced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. The aim of this study is to assess the hemodynamic response to water immer-sion, gymnastics and swimming in patients with heart failure (CHF). Methods We examined 10 patients with compensated CHF (62.9 +/- 6.3 years, EF 31.5 +/- 4.1%, peak VO2 19.4 +/- 2.8 ml/kg/min.), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 +/- 5.6 years, EF 63.9 +/- 5.5%, peak VO2 28.0 +/- 6.3 ml/kg/min.) and 10 healthy subjects (32.8 +/- 7.2 years, peak VO2 45.6 +/- 6.0 ml/kg/min.). Hemodynamic response to thermo-neutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Results Water immersion up to the chest increased cardiac index by 19% in healthy subjects, by 21% in CAD patients and 16% in CHF patients. While some CHF patients showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, 77% in CAD patients and 53% in CHF patients). Oxygen uptake during swim-ming was 9.7 +/- 3.3 ml/kg/min. in CHF patients, 12.4 +/- 3.5 ml/kg/min. in CAD patients and 13.9 +/- 4.0 ml/kg/min. in healthy subjects. Conclusions Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak VO2 of at least 15 ml/kg/min. during a symptom-limited exercise stress test tolerate water immersion and swimming in thermo-neutral water well. Although cardiac in-dex and oxygen uptake are lower compared with CAD patients with preserved left ventricular function and healthy controls, these patients are able to increase cardiac index adequately during water immersion and swimming.