963 resultados para CONCENTRATED LOADS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The aim of this in vitro study was to assess the effects of saliva substitutes (modified with respect to calcium, phosphates, and fluorides) in combination with a high-concentrated fluoride toothpaste on demineralised dentin.Methods: Before and after demineralisation of bovine dentin specimens (subsurface lesions; 37 degrees C, pH 5.0, 5 d), one-quarter of each specimen's surface was covered with nail varnish (control of sound/demineralised tissue). Subsequently, specimens were exposed to original Saliva natura (saturation with respect to octacalciumphosphate [S(OCP)]: 0.03; SN 0), or to three lab-produced Saliva natura modifications (S(OCP): 1, 2, and 3; SN 1-3) for 2 and 5 weeks (37 degrees C). An aqueous solution (S(OCP): 2.5) served as positive control (PC). Two times daily (2 min each), Duraphat toothpaste (5000 ppm F(-); Colgate)/saliva substitute slurry (ratio 1:3) was applied gently. Differences in mineral losses (Delta Delta Z) and lesion depths (Delta LD) between values before and after exposure were microradiographically evaluated.Results: After both treatment periods specimens immersed in SN 0 revealed significantly higher mineral losses (lower Delta Delta Z values) and lesion depths (lower Delta LD) compared to PC (p < 0.05; ANOVA). After 5 weeks, specimens stored in SN 1 and 2 showed significantly higher mineral losses compared to PC (p < 0.05), while those stored in SN 3 showed similar results (p > 0.05). No differences in mineral loss could be observed between SN 2 and 3 (p > 0.05).Conclusions: Under the conditions of this limited protocol, the combination of Saliva natura solutions slightly saturated with respect to OCP in combination with a high-concentrated fluoride toothpaste enabled remineralisation of dentin in vitro. Crown Copyright (c) 2009 Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Data on flow properties of Frozen Concentrated Orange Juice (FCOJ) produced from oranges cv. Pera-Rio (65.04 Brix, 8.8% w/w pulp content, 2.5% w/w pectin, 3.84% citric acid, 1.293 g cm(-3)) from -18 to 0 degrees C were fitted with appropriate predictive models. The power law model was found to be the most appropriate to fit the flow curves obtained for FCOJ between 46.56 and 65.04 degrees Brix. In higher concentrations, thixotropy was observed and showed more temperature dependence. A single equation combining Arrhenius and exponential relationships was applied to describe the temperature effect and shear rate on the quantity of breakdown of FCOJ.
Resumo:
The procedure for formaldehyde analysis recommended by the National Institute for Occupational Safety and Health (NIOSH) is the Chromotropic acid spectrophotometric method, which is the one that uses concentrated sulphuric acid. In the present study the oxidation step associated with the aforementioned method for formaldehyde determination was investigated. Experimental evidence has been obtained indicating that when concentrated H2SO4 (18 mol l(-1)) is used (as in the NIOSH procedure) that acid is the oxidizing agent. on the other hand, oxidation through dissolved oxygen takes place when concentrated H2SO4 is replaced by concentrated hydrochloric (12 mol l(-1)) and phosphoric (14.7 mol l(-1)) acids as well as by diluted H2SO4 (9.4 mol l(-1)). Based on investigations concerning the oxidation step, a modified procedure was devised, in which the use of the potentially hazardous and corrosive concentrated H2SO4 was eliminated and advantageously replaced by a less harmful mixture of HCl and H2O2. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Two concentrated solutions of NiBr2 have been examined by x-ray diffraction. The Fourier transformed scattering data indicate inner complex formation between Ni2 + and Br- ions. Average numbers of bonded bromide ions per nickel atom have been determined for each solution and the reliability of the complexation numbers as well as of the other structural parameters has been critically examined. © 1985 American Institute of Physics.
Resumo:
The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.
Resumo:
Inverted flying exercise with external loads of 25, 50, 75 and 100% of each individual maximum load in the pectoralis major and deltoideus anterior muscles was electromyographically analyzed in eleven male volunteers, using surface electrodes MEDI-TRACE-200 connected to a biological signals acquisition module coupled to a PC/AT computer. Electromyographic signals were processed and the effective values obtained were standardized through maximum voluntary isometric contraction. When the concentric phase of each muscle with the same load was statistically compared with the eccentric phase, it was observed that for all loads all the muscles presented significant electromyographic difference, and that the concentric phase was always higher. By analyzing the different loads for each muscle, it was noticed that in the concentric phase all the muscles presented significant electromyographic activity, being it higher with maximum load. When the effect of each load on different muscle in the concentric and eccentric phases was analyzed, the muscles presented a distinct activity profile.
Resumo:
This paper is the result of real-scale physical modeling study designed to simulate the load-deformation characteristics of railroad foundation systems that include the railroad ties, the ballast, and the sub-base layers of a railroad embankment. The study presents comparisons of the application of dynamic loads of 100kN on the rails, and the resulting deformations during a 500,000 cycle testing period for three rail support systems; wood, concrete and steel. The results show that the deformation curve has an exponential shape, with the larger portion of the deformation occurring during the first 50,000 load cycles followed by a tendency to stabilize between 100,000 to 500,000 cycles. These results indicate that the critical phase of deformations of a new railroad is within the first 50,000 cycles of loading, and after that, it slowly attenuates as it approaches a stable value. The paper also presents empirically derived formulations for the estimation of the deformations of the rail supports as a result of rail traffic.
Resumo:
Due to a shortage of textbooks with specific data on muscular activity concerning physical conditioning and sports, we analysed electromyographically the muscles pectoralis major and deltoideus anterior, bilaterally, in inclined flying exercises, during the concentric and eccentric phases, with external loads of 25, 50, 75 and 100% of the maximum load. The electromyographic analysis was performed in eleven male volunteers with MEDITRACE-200 surface electrodes connected to a six-channel biologic signal acquisition module coupled to a PC/AT computer. The electromyographic signals were processed and the obtained effective values were normalized through maximum voluntary isometric contraction. Statistically, the results showed that all the muscles studied presented significant differences between the concentric and the eccentric phases, with higher electromyographic activity during the concentric phase. By analysing the different loads for each muscle in both phases, significant electromyographic activity was observed for all muscles. When the effect of each load on each muscle during the concentric phase was analysed, it was noticed that the muscles on the left were more active than those on the right side, while in the eccentric phase the muscles had different behavior.