819 resultados para Beam search


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main focus of this essay is the first American round-the-world scientific voyage, the U. S Exploring Expedition, which took place between 1838 and 1841 and was lead by Lieutenant Charles Wilkes. Here, I discuss the purposes of this expedition in the context of the voyages of circumnavigation accomplished by the various European powers during the same period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The presence of coronary artery calcium (CAC) is an independent marker of increased risk of cardiovascular disease (CVD) events and mortality. However, the predictive value of thoracic aorta calcification (TAC), which can be additionally identified without further scanning during assessment of CAC, is unknown. Methods: We followed a cohort of 8401 asymptomatic individuals (mean age: 53 +/- 10 years, 69% men) undergoing cardiac risk factor evaluation and TAC and CAC testing with electron beam computed tomography. Multivariable Cox proportional hazards models were developed to predict all-cause mortality based on the presence of TAC. Results: During a median follow-up period of 5 years, 124 (1.5%) deaths were observed. Overall survival was 96.9% and 98.9% for those with and without detectable TAC, respectively (p < 0.0001). Compared to those with no TAC, the hazard ratio for mortality in the presence of TAC was 3.25 (95% CI: 2.28-4.65, p < 0.0001) in unadjusted analysis. After adjusting for age, gender, hypertension, dyslipidemia, diabetes mellitus, smoking and family history of premature coronary artery disease, and presence of CAC the relationship remained robust (HR 1.61, 95% CI: 1.10-2.27, p = 0.015). Likelihood ratio chi(2) statistics demonstrated that the addition of TAC contributed significantly in predicting mortality to traditional risk factors alone (chi(2) = 13.62, p = 0.002) as well as risk factors + CAC (chi(2) = 5.84, p = 0.02) models. Conclusion: In conclusion, the presence of TAC was associated with all-cause mortality in our study; this relationship was independent of conventional CVD risk factors as well as the presence of CAC. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic beryllium disease (CBD) is clinically similar to other granulomatous diseases such as sarcoidosis. It is often misdiagnosed if a thorough occupational history is not taken. When appropriate, a beryllium lymphocyte proliferation tests (BeLPT) need to be performed. We aimed to search for CBD among currently diagnosed pulmonary sarcoidosis patients and to identify the occupations and exposures in Ontario leading to CBD. Questionnaire items included work history and details of possible exposure to beryllium. Participants who provided a history of previous work with metals underwent BeLPTs and an ELISPOT on the basis of having a higher pretest probability of CBD. Among 121 sarcoid patients enrolled, 87 (72%) reported no known previous metal dust or fume exposure, while 34 (28%) had metal exposure, including 17 (14%) with beryllium exposure at work or home. However, none of these 34 who underwent testing had positive test results. Self-reported exposure to beryllium or metals was relatively common in these patients with clinical sarcoidosis, but CBD was not confirmed using blood assays in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feature selection is one of important and frequently used techniques in data preprocessing. It can improve the efficiency and the effectiveness of data mining by reducing the dimensions of feature space and removing the irrelevant and redundant information. Feature selection can be viewed as a global optimization problem of finding a minimum set of M relevant features that describes the dataset as well as the original N attributes. In this paper, we apply the adaptive partitioned random search strategy into our feature selection algorithm. Under this search strategy, the partition structure and evaluation function is proposed for feature selection problem. This algorithm ensures the global optimal solution in theory and avoids complete randomness in search direction. The good property of our algorithm is shown through the theoretical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have shown that autologous hematopoietic SCT (HSCT) can be used as an intensive immunosuppressive therapy to treat refractory patients and to prevent the progression of multiple sclerosis (MS). This is a prospective multicentric Brazilian MS trial comparing two conditioning regimens: BEAM/horse ATG and CY/rabbit ATG. Most (80.4%) of the 41 subjects in the study had the secondary progressive MS subtype and the mean age was 42 years. The baseline EDSS score in 58.5% of the subjects was 6.5 and 78% had a score of 6.0 or higher, respectively. The complication rate during the intra-transplantation period was 56% for all patients: 71.4% of the patients in the BEAM/hATG group and 40% in the CY/rATG group (P = 0.04). Three subjects (7.5%) died of cardiac toxicity, sepsis and alveolar hemorrhage, all of them in the BEAM/ATG group. EFS was 58.54% for a ll patients: 47% in the BEAM/hATG group and 70% in the CY/rATG group (P = 0.288). In conclusion, the CY/rATG regimen seems to be associated with similar outcome results, but presented less toxicity when compared with the BEAM/hATG regimen. Long-term follow-up would be required to fully assess the differences in therapeutic effectiveness between the two regimens. Bone Marrow Transplantation (2010) 45, 239-248; doi:10.1038/bmt.2009.127; published online 6 July 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formal Concept Analysis is an unsupervised machine learning technique that has successfully been applied to document organisation by considering documents as objects and keywords as attributes. The basic algorithms of Formal Concept Analysis then allow an intelligent information retrieval system to cluster documents according to keyword views. This paper investigates the scalability of this idea. In particular we present the results of applying spatial data structures to large datasets in formal concept analysis. Our experiments are motivated by the application of the Formal Concept Analysis idea of a virtual filesystem [11,17,15]. In particular the libferris [1] Semantic File System. This paper presents customizations to an RD-Tree Generalized Index Search Tree based index structure to better support the application of Formal Concept Analysis to large data sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in radiotherapy. (c) 2009 Elsevier Ltd. All rights reserved.