991 resultados para Atomic absorption
Resumo:
In the present work, the development of a method based on the coupling of flow analysis (FA), hydride generation (HG), and derivative molecular absorption spectrophotometry (D-EAM) in gas phase (GP), is described in order to determine total antimony in antileishmanial products. Second derivative order (D²224nm) of the absorption spectrum (190 - 300 nm) is utilized as measurement criterion. Each one of the parameters involved in the development of the proposed method was examined and optimized. The utilization of the EAM in GP as detection system in a continuous mode instead of atomic absorption spectrometry represents the great potential of the analytic proposal.
Resumo:
Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma optical emission spectrometry (ICP OES) are widely used in academic institutions and laboratories for quality control to analyze inorganic elements in samples. However, these techniques have been observed to underperform in sample nebulization processes. Most of the samples processed through nebulization system are discarded, producing large volumes of waste. This study reports the treatment and reuse of the waste produced from ICP OES technique in a laboratory of analytical research at the Universidade Federal do Ceará, Brazil. The treatment of the waste was performed by the precipitation of elements using (NH4)2CO3. Subsequently, the supernatant solution can be discarded in accordance with CONAMA 430/2011. The precipitate produced from the treatment of residues can be reused as a potential sample in undergraduate qualitative analytical chemistry lab classes, providing students the opportunity to test a real sample.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Cloud point extraction (CPE) was employed for separation and preconcentration prior to the determination of nickel by graphite furnace atomic absorption spectrometry (GFAAS), flame atomic absorption spectrometry (FAAS) or UV-Vis spectrophotometry. Di-2-pyridyl ketone salicyloylhydrazone (DPKSH) was used for the first time as a complexing agent in CPE. The nickel complex was extracted from the aqueous phase using the Triton X-114 surfactant. Under optimized conditions, limits of detection obtained with GFAAS, FAAS and UV-Vis spectrophotometry were 0.14, 0.76 and 1.5 mu g L-1, respectively. The extraction was quantitative and the enrichment factor was estimated to be 27. The method was applied to natural waters, hemodialysis concentrates, urine and honey samples. Accuracy was evaluated by analysis of the NIST 1643e Water standard reference material.
Resumo:
The presence of calcium, iron, and zinc bound to human milk secretory IgA (sIgA) was investigated. The sIgA components were first separated by two-dimensional polyacrylamide gel electrophoresis and then identified by electrospray ionization-tandem mass spectrometry (ESI MS MS). The metal ions were detected by flame atomic absorption spectrometry after acid mineralization of the spots. The results showed eight protein spots corresponding to the IgA heavy chain constant region. Another spot was identified as the transmembrane secretory component. Calcium was bound to both the transmembrane component and the heavy chain constant region, while zinc was bound to the heavy chain constant region and iron was not bound with the identified proteins. The association of a metal ion with a protein is important for a number of reasons, and therefore, the findings of the present study may lead to a better understanding of the mechanisms of action and of additional roles that sIgA and its components play in human milk.
Resumo:
Adsorptive stripping voltammetry carried out in a homogeneous ternary solvent composed of N,N-dimethylformamide, water and ethanol, with alpha-benzoinoxime (alphaBO) as the complexing agent for Mo(VI) and a 0.5 mol L-1 acetic acid - sodium acetate buffer as supporting electrolyte was successfully used for the determination of molybdenum in polyvitamin-polymineral tablets. Tablet samples were analyzed and the results were compared with those obtained both by graphite furnace atomic absorption and by recovery tests, with good correlations, indicating that this may be considered as an alternative procedure for routine determination of Mo(VI) in pharmaceutical samples.
Resumo:
The objective of this study is to investigate the efficiency of calcium carbonate bioprecipitation by Lysinibacillus sphaericus, Bacillus subtilis and Pseudomonas putida, obtained from the Coleção de Culturas do Instituto Nacional de Controle de Qualidade em Saúde (INCQS), as a first step in determining their potential to protect building materials against water uptake. Two culture media were studied: modified B4 containing calcium acetate and 295 with calcium chloride. Calcium consumption in the two media after incubation with and without the bacterial inoculum was determined by atomic absorption analysis. Modified B4 gave the best results and in this medium Pseudomonas putida INQCS 113 produced the highest calcium carbonate precipitation, followed by Lysinibacillus sphaericus INQCS 414; the lowest precipitation was produced by Bacillus subtilis INQCS 328. In this culture medium XRD analysis showed that Pseudomonas putida and Bacillus subtilis precipitated calcite and vaterite polymorphs while Lysinibacillus sphaericus produced only vaterite. The shape and size of the crystals were affected by culture medium, bacterial strain and culture conditions, static or shaken. In conclusion, of the three strains Pseudomonas putida INQCS 113 in modified B4 medium gave the best results precipitating 96% of the calcium, this strain thus has good potential for use on building materials.
Resumo:
Several sample preparation strategies were employed for determination and fractionation of barium in Brazil nuts using measurements by graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma optical emission spectrometry with axial view (ICP OES). This food is widely consumed because of its nutritional value and good taste. The chemical analysis of Brazil nuts is not trivial due to their complex matrix. The fractionation of barium in Brazil nuts was studied owing to the toxicity of this element and the strong correlation between chemical form and absorption. Total concentrations of barium varied from 860 to 2084 mg kg-1. Sequential extractions were performed based on solubility in different media and also according to lipids, proteins and low molecular weight fractions (LMW). The greatest contents of barium were determined in the LMW and in the water insoluble fractions with concentrations in the range 778 to 1606 and 551 to 1520 mg kg-1, respectively. Based on these results it can be inferred that Ba is not absorbed when Brazil nuts are ingested. Considering both the contents of barium and sulfur in different fractions and stoichiometric calculations it was also possible to assume that barium occurs mainly in the BaSO4 form. The presence of this chemical form was also confirmed by thermogravimetric measurements.
Resumo:
OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.
Resumo:
This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.
Resumo:
This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.
Resumo:
As distribuidoras de combustíveis utilizam containers de aço inoxidável para o armazenamento de biocombustíveis, entretanto, na literatura, há poucos relatos sobre os aspectos corrosivos desse aço em biodiesel. O objetivo desse trabalho é estudar o comportamento corrosivo do aço inoxidável austenítico 304 na presença de biodiesel, não lavado e lavado com soluções aquosas de ácido cítrico, oxálico, acético e ascórbico 0,01 mol L-1e comparar com os resultados obtidos para o cobre (ASTM D130). Empregaram-se técnicas como: espectrometria de absorção atômica (EAA) e microscopia óptica (MO). Os resultados de EAA mostraram uma baixa taxa de corrosão para o aço inoxidável, os elementos de liga estudados foram Cr, Ni e Fe, a maior taxa observada foi para o cromo, 1,78 ppm/dia em biodiesel não lavado ou lavado. As MO do aço 304, quando comparados com as do cobre, comprovaram a baixa taxa de corrosão para o sistema aço 304/biodiesel, entretanto comprovaram que, tanto o aço 304, quanto o cobre, sofrem corrosão em amostras de biodiesel.
Resumo:
Lead poisoning has been reportedly linked to a high risk of learning disabilities, aggression and criminal offenses. To study the association between lead exposure and antisocial/delinquent behavior, a cross-sectional study was conducted with 173 Brazilian youths aged 14\201318 and their parents (n = 93), living in impoverished neighborhoods of Bauru-SP, with high criminality indices. Self-Reported Delinquency (SRD) and Child Behavior Checklist (CBCL) questionnaires were used to evaluate delinquent/antisocial behavior. Body lead burdens were evaluated in surface dental enamel acid microbiopsies. The dental enamel lead levels (DELL) were quantified by graphite furnace atomic absorption spectrometry (GFAAS) and phosphorus content was measured using inductively coupled plasma optical emission spectrometry (ICP-OES). Logistic regression was used to identify associations between DELL and each scale defined by CBCL and SRD scores. Odd ratios adjusted for familial and social covariates, considering a group of youths exposed to high lead levels (\2265 75 percentile), indicated that high DELL is associated with increased risk of exceeding the clinical score for somatic complaints, social problems, rule-breaking behavior and externalizing problems (CI 95 per cent). High DELL was not found to be associated with elevated SRD scores. In conclusion, our data support the hypothesis that high-level lead exposure can trigger antisocial behavior, which calls for public policies to prevent lead poisoning