879 resultados para Antibody microarray
Resumo:
The present immuno-diagnostic method using soluble antigens from whole cell lysate antigen for trypanosomosis have certain inherent problems like lack of standardized and reproducible antigens, as well as ethical issues due to in vivo production, that could be alleviated by in vitro production. In the present study we have identified heat shock protein 70 (HSP70) from T. evansi proteome. The nucleotide sequence of T. evansi HSP70 was 2116 bp, which encodes 690 amino acid residues. The phylogenetic analysis of T. evansi HSP70 showed that T. evansi occurred within Trypanosoma clade and is most closely related to T. brucei brucei and T. brucei gambiense, whereas T. congolense HSP70 laid in separate clade. The two partial HSP70 sequences (HSP-1 from N-terminal region and HSP-2 from C-terminal region) were expressed and evaluated as diagnostic antigens using experimentally infected equine serum samples. Both recombinant proteins detected antibody in immunoblot using serum samples from experimental infected donkeys with T. evansi. Recombinant HSP-2 showed comparable antibody response to Whole cell lysate (WCL) antigen in immunoblot and ELISA. The initial results indicated that HSP70 has potential to detect the T. evansi infection and needs further validation on large set of equine serum samples.
Resumo:
Gene microarray technology is highly effective in screening for differential gene expression and has hence become a popular tool in the molecular investigation of cancer. When applied to tumours, molecular characteristics may be correlated with clinical features such as response to chemotherapy. Exploitation of the huge amount of data generated by microarrays is difficult, however, and constitutes a major challenge in the advancement of this methodology. Independent component analysis (ICA), a modern statistical method, allows us to better understand data in such complex and noisy measurement environments. The technique has the potential to significantly increase the quality of the resulting data and improve the biological validity of subsequent analysis. We performed microarray experiments on 31 postmenopausal endometrial biopsies, comprising 11 benign and 20 malignant samples. We compared ICA to the established methods of principal component analysis (PCA), Cyber-T, and SAM. We show that ICA generated patterns that clearly characterized the malignant samples studied, in contrast to PCA. Moreover, ICA improved the biological validity of the genes identified as differentially expressed in endometrial carcinoma, compared to those found by Cyber-T and SAM. In particular, several genes involved in lipid metabolism that are differentially expressed in endometrial carcinoma were only found using this method. This report highlights the potential of ICA in the analysis of microarray data.
Resumo:
13 p.
Resumo:
A parallel plate flow chamber was used to study the interaction force between human IgG (immobilized on a chip surface as ligand) and goat anti-human IgG (immobilized on microspheres surface as receptor). First, it was demonstrated that the binding force between the microspheres and the chip surface came from the bio-specific interaction between the antigen and the antibody. Secondly, it was obtained that the critical shear rate to detach microspheres from the chip surface increases with the ligand surface concentration. Finally, two models to estimate the antigen-antibody bond strength considering bonds' positions were proposed and analyzed.
Resumo:
It is to investigate molecule interactions between antigen and antibody with ellipsometric imaging technique and demonstrate some features and possibilities offered by applications of the technique. Molecule interaction is an important interest for molecule biologist and immunologist. They have used some established methods such as immufluorcence, radioimmunoassay and surface plasma resonance, etc, to study the molecule interaction. At the same time, experimentalists hope to use some updated technique with more direct visual results. Ellipsometric imaging is non-destructive and exhibits a high sensitivity to phase transitions with thin layers. It is capable of imaging local variations in the optical properties such as thickness due to the presence of different surface concentration of molecule or different deposited molecules. If a molecular mono-layer (such as antigen) with bio-activity were deposited on a surface to form a sensing surface and then incubated in a solution with other molecules (such as antibody), a variation of the layer thickness when the molecules on the sensing surface reacted with the others in the solution could be observed with ellipsometric imaging. Every point on the surface was measured at the same time with a high sensitivity to distinguish the variation between mono-layer and molecular complexes. Ellipsometric imaging is based on conventional ellipsometry with charge coupled device (CCD) as detector and images are caught with computer with image processing technique. It has advantages of high sensitivity to thickness variation (resolution in the order of angstrom), big field of view (in square centimeter), high sampling speed (a picture taken within one second), and high lateral resolution (in the order of micrometer). Here it has just shown one application in study of antigen-antibody interaction, and it is possible to observe molecule interaction process with an in-situ technique.
Resumo:
Background: Poor outcomes of invasive candidiasis (IC) are associated with the difficulty in establishing the microbiological diagnosis at an early stage. New scores and laboratory tests have been developed in order to make an early therapeutic intervention in an attempt to reduce the high mortality associated with invasive fungal infections. Candida albicans IFA IgG has been recently commercialized for germ tube antibody detection (CAGTA). This test provides a rapid and simple diagnosis of IC (84.4% sensitivity and 94.7% specificity). The aim of this study is to identify the patients who could be benefited by the use of CAGTA test in critical care setting. Methods: A prospective, cohort, observational multicentre study was carried out in six medical/surgical Intensive care units (ICU) of tertiary-care Spanish hospitals. Candida albicans Germ Tube Antibody test was performed twice a week if predetermined risk factors were present, and serologically demonstrated candidiasis was considered if the testing serum dilution was >= 1: 160 in at least one sample and no other microbiological evidence of invasive candidiasis was found. Results: Fifty-three critically ill non-neutropenic patients (37.7% post surgery) were included. Twenty-two patients (41.5%) had CAGTA-positive results, none of them with positive blood culture for Candida. Neither corrected colonization index nor antifungal treatment had influence on CAGTA results. This finding could corroborate that the CAGTA may be an important biomarker to distinguish between colonization and infection in these patients. The presence of acute renal failure at the beginning of the study was more frequent in CAGTA-negative patients. Previous surgery was statistically more frequent in CAGTA-positive patients. Conclusions: This study identified previous surgery as the principal clinical factor associated with CAGTA-positive results and emphasises the utility of this promising technique, which was not influenced by high Candida colonization or antifungal treatment. Our results suggest that detection of CAGTA may be important for the diagnosis of invasive candidiasis in surgical patients admitted in ICU.
Phage M13Ko7 Detection With Biosensor Based On Imaging Ellipsometry And Afm Microscopic Confirmation
Resumo:
A rapid detection and identification of pathogens is important for minimizing transfer and spread of disease. A label-free and multiplex biosensor based on imaging ellipsometry (BIE) had been developed for the detection of phage M13KO7. The surface of silicon wafer is modified with aldehyde, and proteins can be patterned homogeneously and simultaneously on the surface of silicon wafer in an array format by a microfluidic system. Avidin is immobilized on the surface for biotin-anti-M13 immobilization by means of interaction between avidin and biotin, which will serve as ligand against phage M13KO7. Phages M13KO7 are specifically captured by the ligand when phage M13KO7 solution passes over the surface, resulting in a significant increase of mass surface concentration of the anti-M13 binding phage M13KO7 layer, which could be detected by imaging ellipsometry with a sensitivity of 10(9) pfu/ml. Moreover, atomic force microscopy is also used to confirm the fact that phage M13KO7 has been directly captured by ligands on the surface. It indicates that BIE is competent for direct detection of phage M13KO7 and has potential in the field of virus detection. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
One of existing strategies to engineer active antibody is to link VH and VL domains via a linker peptide. How the composition, length, and conformation of the linker affect antibody activity, however, remains poorly understood. In this study, a dual approach that coordinates molecule modeling, biological measurements, and affinity evaluation was developed to quantify the binding activity of a novel stable miniaturized anti-CD20 antibody or singlechain fragment variable (scFv) with a linker peptide. Upon computer-guided homology modeling, distance geometry analysis, and molecular superimposition and optimization, three new linker peptides PT1, PT2, and PT3 with respective 7, 10, and 15 residues were proposed and three engineered antibodies were then constructed by linking the cloned VH and VL domains and fusing to a derivative of human IgG1. The binding stability and activity of scFv-Fc chimera to CD20 antigen was quantified using a micropipette adhesion frequency assay and a Scatchard analysis. Our data indicated that the binding affinity was similar for the chimera with PT2 or PT3 and ~24-fold higher than that for the chimera with PT1, supporting theoretical predictions in molecular modeling. These results further the understanding in the impact of linker peptide on antibody structure and activity.
Resumo:
Alternative scaffolds are non-antibody proteins that can be engineered to bind new targets. They have found useful niches in the therapeutic space due to their smaller size and the ease with which they can be engineered to be bispecific. We sought a new scaffold that could be used for therapeutic ends and chose the C2 discoidin domain of factor VIII, which is well studied and of human origin. Using yeast surface display, we engineered the C2 domain to bind to αvβ3 integrin with a 16 nM affinity while retaining its thermal stability and monomeric nature. We obtained a crystal structure of the engineered domain at 2.1 Å resolution. We have christened this discoidin domain alternative scaffold the “discobody.”
Resumo:
More than thirty years after the discovery that Human Immunodeficiency Virus (HIV) was the causative agent of Acquired Immunodeficiency Syndrome (AIDS), the disease remains pandemic as long as no effective universal vaccine is found. Over 34 million individuals in the world are infected with the virus, and the vast majority of them have no access to the antiretroviral therapies that have largely reduced HIV to a chronic disease in the developed world. The first chapter of this thesis introduces the history of the virus. The key to the infectious mechanism of the virus lies in its envelope glycoprotein (Env), a trimeric spike on the viral surface that utilizes host T cell receptors for entry. Though HIV-1 Env is immunogenic, most infected patients do not mount an effective neutralizing antibody response against it. Broadly-neutralizing anti-Env antibodies (bNAbs) present in the serum of a minority of infected individuals are usually sufficient to prevent the progression to full blown AIDS. Thus, the molecular details of these bNAbs as well as the antibody-antigen interface are of prime interest for structural studies, as insight gained would contribute to the design of a more effective immunogen and potential vaccine candidate. The second chapter of this thesis describes the low-resolution crystal structure of one such antibody, 2G12 dimer, which targets a high mannose epitope on the surface of Env. Patients infected with HIV-2, a related virus with ~35% sequence identity in the Env region, can generally mount a robust antibody response sufficient for viral control for reasons still unknown. The final two chapters of this thesis focus on the first reported structural studies of HIV-2 Env, the molecular details of which may inform HIV-1 therapy and immunogen design.