998 resultados para Análise por injeção em fluxo
Resumo:
Heparin is a pharmaceutical animal widely used in medicine due to its potent anticoagulant effect. Furthermore, it has the ability to inhibit the proliferation, invasion and adhesion of cancer cells to vascular endothelium. However, its clinical applicability can be compromised by side effects such as bleeding. Thus, the search for natural compounds with low bleeding risk and possible therapeutic applicability has been targeted by several research groups. From this perspective, this study aims to evaluate the hemorrhagic and anticoagulant activities and citotoxic effect for different tumor cell lines (HeLa, B16-F10, HepG2, HS-5,) and fibroblast cells (3T3) of the Heparin-like from the crab Chaceon fenneri (HEP-like). The HEP-like was purified after proteolysis, ion-exchange chromatography, fractionation with acetone and characterized by electrophoresis (agarose gel) and enzymatic degradation. Hep-like showed eletroforetic behavior similar to mammalian heparin, and high trisulfated /Nacetylated disaccharides ratio. In addition, HEP-like presented low in vitro anticoagulant activity using aPTT and a minor hemorrhagic effect when compared to mammalian heparin. Furthermore, the HEP-like showed significant cytotoxic effect (p<0.001) on HeLa, HepG2 and B16-F10 tumor cells with IC50 values of 1000 ug/mL, after incubation for 72 hours. To assess the influence of heparin-like on the cell cycle in HeLa cells, analysis was performed by flow cytometry. The results of this analysis showed that HEP-like influence on the cell cycle increasing S phase and decreasing phase G2. Thus, these properties of HEP-like make these compounds potential therapeutic agents
Resumo:
Dissertação de Mestrado, Oncobiologia, Departamento de Ciências Biomédicas e Medicina, Universidade do Algarve, 2016
Resumo:
Mestrado em Engenharia Agronómica - Instituto Superior de Agronomia - UL
Resumo:
The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.
Resumo:
Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.
Resumo:
Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.
Resumo:
Este trabalho apresenta uma análise da qualidade de energia realizado em um sistema real de distribuição de energia elétrica, a partir das diferentes classes de consumo atendida pela concessionária. O estudo foi realizado em duas etapas, sendo a primeira através de medições realizadas no secundário de transformadores da rede de distribuição que atende ao sistema da CEA (Companhia de Eletricidade do Amapá), previamente classificados por classe de atendimento sendo, classe comercial, residencial e mista. Através do estudo torna-se possível a identificação e a caracterização de fontes geradoras de harmônicos no sistema, possibilitando assim a análise do nível de injeção de harmônicos em sua rede de distribuição, bem como a avaliação dos impactos que essas fontes distribuídas de geração harmônica podem provocar na qualidade de energia fornecida pela concessionária. A etapa final do estudo apresenta o uso de um fluxo de carga harmônico trifásico, onde a partir do perfil harmônico obtido no estudo, é feita uma avaliação de forma global do sistema.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil de Engenharia Sanitária
Resumo:
Dissertação de mestrado em Engenharia Industrial
Resumo:
Pesquisa que analisa o fluxo da informação na prática clínica dos médicos residentes. Para tal, considera os preceitos da medicina baseada em evidências (MBE) e elege como lócus de pesquisa o Hospital Universitário da UFSC e como universo os médicos residentes atuantes nos seus ambulatórios. A relevância do desenvolvimento da pesquisa está amparada em alguns argumentos: reconhecimento da MBE na prática clínica como alternativa para dar suporte à decisão clínica, através da seleção das fontes de informação de maior evidência disponíveis na literatura médica; constatação que há lacuna na literatura nacional para estudos com médicos residentes, uma vez que a maioria das pesquisas enfoca a forma como médicos e professores da área de saúde usam os sistemas e serviços de informação; convicção que o uso de informação selecionada de forma criteriosa possibilitará uma prática clínica mais eficaz. A pesquisa identificou e analisou os processos envolvidos no fluxo informacional na prática clínica do médico, sob as perspectivas de seleção, acesso, recuperação e uso das fontes de informação. Apresenta um modelo de fluxo de informação ideal na perspectiva da MBE.
Resumo:
A flow system based on multicommutation and binary sampling process was developed to implement the sample zone trapping technique in order to increase the spectrophotometric analytical range and to improve sensitivity. The flow network was designed with active devices in order to provide facilities to determine sequentialy analyte with a wide concentration range, employing a single pumping channel to propel sample and reagents solutions. The procedure was employed to determine ortophosphate ions in water samples of river and waste. Profitable features such as an analytical throughput of 60 samples determination per hour, relative standard deviation (r.s.d.) of 2% (n = 6) for a typical sample with concentration of 2.78 mg/L were achieved. By applying the paired t-test no significant difference at 95% confidence level was observed between the results obtained with the proposed system and those of the usual flow injection system.
Resumo:
The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.