Many industrial solids processes require the production of disperse particles. In industries such as food, personal care, and pharmaceuticals, particle formation is widely used to produce solid products or to separate substances in intermediate process steps. The most important characteristics known to impact the effectiveness of a solid product are purity, size, internal structure, and morphology. These characteristics are essential to maintain optimal operation of subsequent process steps and for obtaining the desired high quality product. This thesis aims to aid in the advancement of particle production technology by (1) investigating the use of a vibrating orifice aerosol generator (VOAG) for collecting data to predict particle attributes including morphology, size, and internal structure as a function of processing parameters such as solvent, solution concentration, air flow rate, and initial droplet size, as well as to (2) determine the extent to which uniform droplet evaporation can be a tool to achieve novel particle morphologies, controlled sizes, or internal structures (crystallinity and crystal form). Experimental results for succinic acid, L-serine, and L-glutamic acid suggest that particles of controlled characteristics can indeed be produced by this method. Analysis by scanning electron microscopy (SEM), nanoindentation, and X-ray diffraction (XRD) shows that various sizes, internal structures, and morphologies can be obtained using the VOAG. Furthermore, unique morphologies and unexpected internal structures were able to be achieved for succinic acid, providing an added benefit to particle formation by this method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prevalence of Ventilated Improved Pit (VIP) latrines in Ghana suggests that the design must have a high user acceptance. The two key factors attributed to user acceptance of a VIP latrine over an alternative latrine design, such as the basic pit latrine, are its ability to remove foul odors and maintain low fly populations; both of which are a direct result of an adequate ventilation flow rate. Adequate ventilation for odorless conditions in a VIP latrine has been defined by the United Nations Development Program (UNDP) and the World Bank, as an air flow rate equivalent to 6 air changes per hour (6 ACH) of the superstructure’s air volume. Additionally, the UNDP determined that the three primary factors that affect ventilation are: 1) wind passing over the mouth of the vent pipe, 2) wind passing into the superstructure, and 3) solar radiation on to the vent pipe. Previous studies also indicate that vent pipes with larger diameters increase flow rates, and the application of carbonaceous materials to the pit sludge reduces odor and insect prevalence. Furthermore, proper design and construction is critical for the correct functioning of VIP latrines. Under-designing could cause problems with odor and insect control; over-designing would increase costs unnecessarily, thereby making it potentially unaffordable for benefactors to independently construct, repair or replace a VIP latrine. The present study evaluated the design of VIP latrines used by rural communities in the Upper West Region of Ghana with the focus of assessing adequate ventilation for odor removal and insect control. Thirty VIP latrines from six communities in the Upper West Region of Ghana were sampled. Each VIP latrine’s ventilation flow rate and micro-environment was measured using a hot-wire anemometer probe and portable weather station for a minimum of four hours. To capture any temporal or seasonal variations in ventilation, ten of the latrines were sampled monthly over the course of three months for a minimum of 12 hours. A latrine usage survey and a cost analysis were also conducted to further assess the VIP latrine as an appropriated technology for sustainable development in the Upper West Region. It was found that the average air flow rate over the entire sample set was 11.3 m3/hr. The minimum and maximum air flow rates were 0.0 m3/hr and 48.0 m3/hr respectively. Only 1 of the 30 VIP latrines (3%) was found to have an air flow rate greater than the UNDP-defined odorless condition of 6 ACH. Furthermore, 19 VIP latrines (63%) were found to have an average air flow rate of less than half the flow rate required to achieve 6 ACH. The dominant factors affecting ventilation flow rate were wind passing over the mouth of the vent pipe and air buoyancy forces, which were the effect of differences in temperature between the substructure and the ambient environment. Of 76 usable VIP latrines found in one community, 68.4% were in actual use. The cost of a VIP latrine was found to be equivalent to approximately 12% of the mean annual household income for Upper West Region inhabitants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El gran desarrollo industrial y demográfico de las últimas décadas ha dado lugar a un consumo crecientemente insostenible de energía y materias primas, que influye negativamente en el ambiente por la gran cantidad de contaminantes generados. Entre las emisiones tienen gran importancia los compuestos orgánicos volátiles (COV), y entre ellos los compuestos halogenados como el tricloroetileno, debido a su elevada toxicidad y resistencia a la degradación. Las tecnologías generalmente empleadas para la degradación de estos compuestos presentan inconvenientes derivados de la generación de productos tóxicos intermedios o su elevado coste. Dentro de los procesos avanzados de oxidación (Advanced Oxidation Processes AOP), la fotocatálisis resulta una técnica atractiva e innovadora de interés creciente en su aplicación para la eliminación de multitud de compuestos orgánicos e inorgánicos, y se ha revelado como una tecnología efectiva en la eliminación de compuestos orgánicos volátiles clorados como el tricloroetileno. Además, al poder aprovechar la luz solar como fuente de radiación UV permite una reducción significativa de costes energéticos y de operación. Los semiconductores más adecuados para su empleo como fotocatalizadores con aprovechamiento de la luz solar son aquellos que tienen una banda de energía comparable a la de los fotones de luz visible o, en su defecto, de luz ultravioleta A (Eg < 3,5 eV), siendo el más empleado el dióxido de titanio (TiO2). El objetivo principal de este trabajo es el estudio de polímeros orgánicos comerciales como soporte para el TiO2 en fotocatálisis heterogénea y su ensayo para la eliminación de tricloroetileno en aire. Para ello, se han evaluado sus propiedades ópticas y su resistencia a la fotodegradación, y se ha optimizado la fijación del fotocatalizador para conseguir un recubrimiento homogéneo, duradero y con elevada actividad fotocatalítica en diversas condiciones de operación. Los materiales plásticos ensayados fueron el polietileno (PE), copolímero de etil vinil acetato con distintos aditivos (EVA, EVA-H y EVA-SH), polipropileno (PP), polimetil (metacrilato) fabricado en colada y extrusión (PMMA-C y PMMA-E), policarbonato compacto y celular (PC-C y PC-Ce), polivinilo rígido y flexible (PVC-R y PVC-F), poliestireno (PS) y poliésteres (PET y PETG). En base a sus propiedades ópticas se seleccionaron el PP, PS, PMMA-C, EVA-SH y PVC-R, los cuales mostraron un valor de transmitancia superior al 80% en el entorno de la región estudiada (λ=365nm). Para la síntesis del fotocatalizador se empleó la tecnología sol-gel y la impregnación multicapa de los polímeros seleccionados por el método de dip-coating con secado intermedio a temperaturas moderadas. Con el fin de evaluar el envejecimiento de los polímeros bajo la radiación UV, y el efecto sobre éste del recubrimiento fotoactivo, se realizó un estudio en una cámara de exposición a la luz solar durante 150 días, evaluándose la resistencia química y la resistencia mecánica. Los resultados de espectroscopía infrarroja y del test de tracción tras el envejecimiento revelaron una mayor resistencia del PMMA y una degradación mayor en el PS, PVC-R y EVA SH, con una apreciable pérdida del recubrimiento en todos los polímeros. Los fotocatalizadores preparados sobre soportes sin tratamiento y con tres capas de óxido de titanio mostraron mejores resultados de actividad con PMMA-C, PET y PS, con buenos resultados de mineralización. Para conseguir una mayor y mejor fijación de la película al soporte se realizaron tratamientos químicos abrasivos con H2SO4 y NaOH y tratamientos de funcionalización superficial por tecnología de plasma a presión atmosférica (APP) y a baja presión (LPP). Con los tratamientos de plasma se consiguió una excelente mojabilidad de los soportes, que dio lugar a una distribución uniforme y más abundante del fotocatalizador, mientras que con los tratamientos químicos no se obtuvo una mejora significativa. Asimismo, se prepararon fotocatalizadores con una capa previa de dióxido de silicio con la intervención de surfactantes (PDDA-SiO2-3TiO2 y SiO2FC-3TiO2), consiguiéndose buenas propiedades de la película en todos los casos. Los mejores resultados de actividad con tratamiento LPP y tres capas de TiO2 se lograron con PMMA-C (91% de conversión a 30 ppm de TCE y caudal 200 ml·min-1) mejorando significativamente también la actividad fotocatalítica en PVC-R y PS. Sin embargo, el material más activo de todos los ensayados fue el PMMA-C con el recubrimiento SiO2FC-3TiO2, logrando el mejor grado de mineralización, del 45%, y una velocidad de 1,89 x 10-6 mol· m-2 · s-1, que dio lugar a la eliminación del 100 % del tricloroetileno en las condiciones anteriormente descritas. A modo comparativo se realizaron ensayos de actividad con otro contaminante orgánico tipo, el formaldehído, cuya degradación fotocatalítica fue también excelente (100% de conversión y 80% de mineralización con 24 ppm de HCHO en un caudal de aire seco de 200 ml·min-1). Los buenos resultados de actividad obtenidos confirman las enormes posibilidades que ofrecen los polímeros transparentes en el UV-A como soportes del dióxido de titanio para la eliminación fotocatalítica de contaminantes en aire. ABSTRACT The great industrial and demographic development of recent decades has led to an unsustainable increase of energy and raw materials consumption that negatively affects the environment due to the large amount of waste and pollutants generated. Between emissions generated organic compounds (VOCs), specially the halogenated ones such as trichloroethylene, are particularly important due to its high toxicity and resistance to degradation. The technologies generally used for the degradation of these compounds have serious inconveniences due to the generation of toxic intermediates turn creating the problem of disposal besides the high cost. Among the advanced oxidation processes (AOP), photocatalysis is an attractive and innovative technique with growing interest in its application for the removal of many organic and inorganic compounds, and has emerged as an effective technology in eliminating chlorinated organic compounds such as trichloroethylene. In addition, as it allows the use of sunlight as a source of UV radiation there is a significant reduction of energy costs and operation. Semiconductors suitable to be used as photocatalyst activated by sunlight are those having an energy band comparable to that of the visible or UV-A light (Eg <3,5 eV), being titanium dioxide (TiO2), the most widely used. The main objective of this study is the test of commercial organic polymers as supports for TiO2 to be applied in heterogeneous photocatalysis and its assay for removing trichloroethylene in air. To accomplish that, its optical properties and resistance to photooxidation have been evaluated, and different operating conditions have been tested in order to optimize the fixation of the photocatalyst to obtain a homogeneous coating, with durable and high photocatalytic activity. The plastic materials tested were: polyethylene (PE), ethyl vinyl acetace copolymers with different additives (EVA, EVA-H and EVA -SH), polypropylene (PP), poly methyl (methacrylate) manufactured by sheet moulding and extrusion (PMMA-C and PMMA-E), compact and cellular polycarbonates (PC-C PC-Ce), rigid and flexible polyvinyl chloride (PVC-R and PVC-F), polystyrene (PS) and polyesters (PET and PETG). On the basis of their optical properties PP, PS, PMMA-C, EVA-SH and PVC-R were selected, as they showed a transmittance value greater than 80% in the range of the studied region (λ = 365nm). For the synthesis of the photocatalyst sol-gel technology was employed with multilayers impregnation of the polymers selected by dip-coating, with intermediate TiO2 drying at moderate temperatures. To evaluate the polymers aging due to UV radiation, and the effect of photoactive coating thereon, a study in an sunlight exposure chamber for 150 days was performed, evaluating the chemical resistance and the mechanical strength. The results of infrared spectroscopy and tensile stress test after aging showed the PMMA is the most resistant sample, but a greater degradation in PS, PVC-R and EVA SH, with a visible loss of the coating in all the polymers tested. The photocatalysts prepared on the untreated substrates with three layers of TiO2 showed better activity results when PMMA-C, PET and PS where used. To achieve greater and better fixation of the film to the support, chemical abrasive treatments, with H2SO4 and NaOH, as well as surface functionalization treatments with atmospheric pressure plasma (APP) and low pressure plasma (LPP) technologies were performed. The plasma treatment showed the best results, with an excellent wettability of the substrates that lead to a better and uniform distribution of the photocatalyst compared to the chemical treatments tested, in which no significant improvement was obtained. Also photocatalysts were prepared with the a silicon dioxide previous layer with the help of surfactants (SiO2- 3TiO2 PDDA-and-3TiO2 SiO2FC), obtaining good properties of the film in all cases. The best activity results for LPP-treated samples with three layers of TiO2 were achieved with PMMA-C (91% conversion, in conditions of 30 ppm of TCE and 200 ml·min-1 air flow rate), with a significant improvement of the photocatalytic activity in PVC-R and PS samples too. However, among all the materials assayed, PMMA-C with SiO2FC-3TiO2 coating was the most active one, achieving the highest mineralization grade (45%) and a reaction rate of 1,89 x 10-6 mol· m-2 · s-1, with total trichloroethylene elimination in the same conditions. As a comparative assay, an activity test was also performed with another typical organic contaminant, formaldehyde, also with good results (100% conversion with 24 ppm of HCHO and 200 ml·min-1 gas flow rate). The good activity results obtained in this study confirm the great potential of organic polymers which are transparent in the UV-A as supports for titanium dioxide for photocatalytic removal of air organic pollutants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For nearly 100 years, the flotation plant metallurgist has often wondered what is happening 'beneath the froth'. To assist in unravelling this mystery, new technology has been developed as part of the Australian Mineral Industries Research Association (AMIRA) P9 project, to measure gas dispersion characteristics (such as gas hold-up, superficial gas velocity and bubble size) in industrial flotation cells. These measurements have been conducted in a large number of cells of different types and sizes by researchers from the Julius Kruttschnitt Mineral Research Centre (JKMRC) and JKTech. A large database has been developed and the contents of this database are described in this paper. Typical cell characterization measurements show a wide spread in values, even in the same cell types and sizes performing similar duties. In conventional flotation cells, the typical gas hold-up values range from 3% to 20%, bubble sizes range between I and 2 mm, and superficial gas velocity ranges from 1 to 2.5 cm/s. The ranges of cell characterization measurements given in this paper will enable plant personnel to compare their operation to other similar types of operations from around Australia and the rest of the world, giving opportunities for further improvement to flotation plant operations. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actually, Brazil is one of the larger fruit producer worldwide, with most of its production being consumed in nature way or either as juice or pulp. It is important to highlig ht in the fruit productive chain there are a lot lose due mainly to climate reasons, as well as storage, transportation, season, market, etc. It is known that in the pulp and fruit processing industy a yield of 50% (in mass) is usually obtained, with the other part discarded as waste. However, since most this waste has a high nutrient content it can be used to generate added - value products. In this case, drying plays an important role as an alternative process in order to improve these wastes generated by the fruit industry. However, despite the advantage of using this technique in order to improve such wastes, issues as a higher power demand as well as the thermal efficiency limitation should be addressed. Therefore, the control of the main variables in t his drying process is quite important in order to obtain operational conditions to produce a final product with the target specification as well as with a lower power cost. M athematical models can be applied to this process as a tool in order to optimize t he best conditions. The main aim of this work was to evaluate the drying behaviour of a guava industrial pulp waste using a batch system with a convective - tray dryer both experimentally and using mathematical modeling. In the experimental study , the dryin g carried out using a group of trays as well as the power consume were assayed as response to the effects of operational conditions (temperature, drying air flow rate and solid mass). Obtained results allowed observing the most significant variables in the process. On the other hand, the phenomenological mathematical model was validated and allowed to follow the moisture profile as well as the temperature in the solid and gas phases in every tray. Simulation results showed the most favorable procedure to o btain the minimum processing time as well as the lower power demand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper presents an investigation to the thermodynamics of the air flow in the air chamber for the oscillating water column wave energy converters, in which the oscillating water surface in the water column pressurizes or de-pressurises the air in the chamber. To study the thermodynamics and the compressibility of the air in the chamber, a method is developed in this research: the power take-off is replaced with an accepted semi-empirical relationship between the air flow rate and the oscillating water column chamber pressure, and the thermodynamic process is simplified as an isentropic process. This facilitates the use of a direct expression for the work done on the power take-off by the flowing air and the generation of a single differential equation that defines the thermodynamic process occurring inside the air chamber. Solving the differential equation, the chamber pressure can be obtained if the interior water surface motion is known or the chamber volume (thus the interior water surface motion) if the chamber pressure is known. As a result, the effects of the air compressibility can be studied. Examples given in the paper have shown the compressibility, and its effects on the power losses for large oscillating water column devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Injection stretch blow moulding is a well-established method of forming thin-walled containers and has been extensively researched for numerous years. This paper is concerned with validating the finite element analysis of the free-stretch-blow process in an effort to progress the development of injection stretch blow moulding of poly(ethylene terephthalate). Extensive data was obtained experimentally over a wide process window accounting for material temperature and air flow rate, while capturing cavity pressure, stretch-rod reaction force and preform surface strain. This data was then used to assess the accuracy of the correlating FE simulation constructed using ABAQUS/Explicit solver and an appropriate viscoelastic material subroutine. Results reveal that the simulation is able to give good quantitative correlation for conditions where the deformation was predominantly equal biaxial whilst qualitative correlation was achievable when the mode of deformation was predominantly sequential biaxial. Overall the simulation was able to pick up the general trends of how the pressure, reaction force, strain rate and strain vary with the variation in preform temperature and air flow rate. The knowledge gained from these analyses provides insight into the mechanisms of bottle formation, subsequently improving the blow moulding simulation and allowing for reduction in future development costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Double-pass counter flow v-grove collector is considered one of the most efficient solar air-collectors. In this design of the collector, the inlet air initially flows at the top part of the collector and changes direction once it reaches the end of the collector and flows below the collector to the outlet. A mathematical model is developed for this type of collector and simulation is carried out using MATLAB programme. The simulation results were verified with three distinguished research results and it was found that the simulation has the ability to predict the performance of the air collector accurately as proven by the comparison of experimental data with simulation. The difference between the predicted and experimental results is, at maximum, approximately 7% which is within the acceptable limit considering some uncertainties in the input parameter values to allow comparison. A parametric study was performed and it was found that solar radiation, inlet air temperature, flow rate and length has a significant effect on the efficiency of the air collector. Additionally, the results are compared with single flow V-groove collector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Double-pass counter flow v-grove collector is considered one of the most efficient solar air-collectors. In this design of the collector, the inlet air initially flows at the top part of the collector and changes direction once it reaches the end of the collector and flows below the collector to the outlet. A mathematical model is developed for this type of collector and simulation is carried out using MATLAB programme. The simulation results were verified with three distinguished research results and it was found that the simulation has the ability to predict the performance of the air collector accurately as proven by the comparison of experimental data with simulation. The difference between the predicted and experimental results is, at maximum, approximately 7% which is within the acceptable limit considering some uncertainties in the input parameter values to allow comparison. A parametric study was performed and it was found that solar radiation, inlet air temperature, flow rate and length have a significant effect on the efficiency of the air collector. Additionally, the results are compared with single flow V-groove collector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The transition from a steady to an unsteady flow induced by an adiabatic fin on the sidewall of a differentially heated air-filled cavity is numerically investigated. Numerical simulations have been performed over the range of Rayleigh numbers from Ra = 105–109. The temporal development and spatial structures of natural convection flows in the cavity with a fin are described. It has been demonstrated that the fin may induce the transition to an unsteady flow and the critical Rayleigh number for the occurrence of the transition is between 3.72 × 106 and 3.73 × 106. Furthermore, the peak frequencies of the oscillations triggered by different mechanisms are obtained through spectral analysis. It has been found that the flow rate through the cavity with a fin is larger than that without a fin under the unsteady flow, indicating that the fin may improve the unsteady flow in the cavity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents the results of a study on the association between measured air pollutants and the respiratory health of resident women and children in Lao PDR, one of the least developed countries in Southeast Asia. The study, commissioned by the World Health Organisation, included PM10, CO and NO2 measurements made inside 181 dwellings in nine districts within two provinces in Lao PDR over a 5- month period (12/05–04/06), and respiratory health information (via questionnaires and peak expiratory flow rate (PEFR) measurements) for all residents in the same dwellings. Adjusted odds ratios were calculated separately for each health outcome using binary logistic regression. There was a strong and consistent positive association between NO2 and CO for almost all questionnaire-based health outcomes for both women and children. Women in dwellings with higher measured NO2 had more than triple of the odds of almost all of the health outcomes, and higher concentrations of NO2 and CO were significantly associated with lower PEFR. This study supports a growing literature confirming the role of indoor air pollution in the burden of respiratory disease in developing countries. The results will directly support changes in health and housing policy in Lao PDR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atmospheric-pressure plasma jets are commonly used in many fields from medicine to nanotechnology, yet the issue of scaling the discharges up to larger areas without compromising the plasma uniformity remains a major challenge. In this paper, we demonstrate a homogenous cold air plasmaglow with a large cross-section generated by a direct current power supply. There is no risk of glow-to-arc transitions, and the plasmaglow appears uniform regardless of the gap between the nozzle and the surface being processed. Detailed studies show that both the position of the quartz tube and the gas flow rate can be used to control the plasma properties. Further investigation indicates that the residual charges trapped on the inner surface of the quartz tube may be responsible for the generation of the air plasma plume with a large cross-section. The spatially resolved optical emission spectroscopy reveals that the air plasma plume is uniform as it propagates out of the nozzle. The remarkable improvement of the plasma uniformity is used to improve the bio-compatibility of a glass coverslip over a reasonably large area. This improvement is demonstrated by a much more uniform and effective attachment and proliferation of human embryonic kidney 293 (HEK 293) cells on the plasma-treated surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of various discharge parameters and ambient gas on the length of He atmospheric plasma jet plumes expanding into the open air are studied. It is found that the voltage and width of the discharge-sustaining pulses exert significantly stronger effects on the plume length than the pulse frequency, gas flow rate, and nozzle diameter. This result is explained through detailed analysis of the I-V characteristics of the primary and secondary discharges which reveals the major role of the integrated total charges of the primary discharge in the plasma dynamics. The length of the jet plume can be significantly increased by guiding the propagating plume into a glass tube attached to the nozzle. This increase is attributed to elimination of the diffusion of surrounding air into the plasma plume, an absence which facilitates the propagation of the ionization front. These results are important for establishing a good level of understanding of the expansion dynamics and for enabling a high degree of control of atmospheric pressure plasmas in biomedical, materials synthesis and processing, environmental and other existing and emerging industrial applications. © 2009 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A nonlinear control design approach is presented in this paper for a challenging application problem of ensuring robust performance of an air-breathing engine operating at supersonic speed. The primary objective of control design is to ensure that the engine produces the required thrust that tracks the commanded thrust as closely as possible by appropriate regulation of the fuel flow rate. However, since the engine operates in the supersonic range, an important secondary objective is to ensure an optimal location of the shock in the intake for maximum pressure recovery with a sufficient margin. This is manipulated by varying the throat area of the nozzle. The nonlinear dynamic inversion technique has been successfully used to achieve both of the above objectives. In this problem, since the process is faster than the actuators, independent control designs have also been carried out for the actuators as well to assure the satisfactory performance of the system. Moreover, an extended Kalman Filter based state estimation design has been carried out both to filter out the process and sensor noises as well as to make the control design operate based on output feedback. Promising simulation results indicate that the proposed control design approach is quite successful in obtaining robust performance of the air-breathing system.