853 resultados para 24 hour measurement
Resumo:
When assessing food intake patterns in groups of individuals, a major problem is finding usual intake distribution. This study aimed at searching for a probability distribution to estimate the usual intake of nutrients using data from a cross-sectional investigation on nutrition students from a public university in São Paulo state, Brazil. Data on 119 women aged 19 to 30 years old were used. All women answered a questionnaire about their lifestyle, diet and demographics. Food intake was evaluated from a non-consecutive three-day 24-hour food record. Different probability distributions were tested for vitamins C and E, panthotenic acid, folate, zinc, copper and calcium where data normalization was not possible. Empirical comparisons were performed, and inadequacy prevalence was calculated by comparing with the NRC method. It was concluded that if a more realistic distribution for usual intake is found, results can be more accurate as compared to those achieved by other methods.
Resumo:
Eight premature infants ventilated for hyaline membrane disease and enrolled in the OSIRIS surfactant trial were studied. Lung mechanics, gas exchange [PaCO2, arterial/alveolar PO2 ratio (a/A ratio)], and ventilator settings were determined 20 minutes before and 20 minutes after the end of Exosurf instillation, and subsequently at 12-24 hour intervals. Respiratory system compliance (Crs) and resistance (Rrs) were measured by means of the single breath occlusion method. After surfactant instillation there were no significant immediate changes in PaCO2 (36 vs. 37 mmHg), a/A ratio (0.23 vs. 0.20), Crs (0.32 vs. 0.31 mL/cm H2O/kg), and Rrs (0.11 vs. 0.16 cmH2O/mL/s) (pooled data of 18 measurement pairs). During the clinical course, mean a/A ratio improved significantly each time from 0.17 (time 0) to 0.29 (time 12-13 hours), to 0.39 (time 24-36 hours) and to 0.60 (time 48-61 hours), although mean airway pressure was reduced substantially. Mean Crs increased significantly from 0.28 mL/cmH2O/kg (time 0) to 0.38 (time 12-13 hours), to 0.37 (time 24-38 hours), and to 0.52 (time 48-61 hours), whereas mean Rrs increased from 0.10 cm H2O/mL/s (time 0) to 0.11 (time 12-13 hours), to 0.13 (time 24-36 hours) and to (time 48-61 hours) with no overall significance. A highly significant correlation was found between Crs and a/A ratio (r = 0.698, P less than 0.001). We conclude that Exosurf does not induce immediate changes in oxygenation as does the instillation of (modified) natural surfactant preparations. However, after 12 and 24 hours of treatment oxygenation and Crs improve significantly.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
OBJECTIVES: (1) To assess spinal cord blood flow (SCBF) during surgical treatment of disk extrusion in dogs and (2) to investigate associations between SCBF, clinical signs, presurgical MRI images, and 24-hour surgical outcome. STUDY DESIGN: Cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n=12). METHODS: Diagnosis was based on clinical signs and MRI findings, and confirmed at surgery. Regional SCBF was measured intraoperatively by laser-Doppler flowmetry before, immediately after surgical spinal cord decompression, and after 15 minutes of lavaging the lesion. Care was taken to ensure a standardized surgical procedure to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found in all dogs (Wilcoxon's signed-rank test; P=.05) immediately after spinal cord decompression and after 15 minutes. Changes in SCBF were not associated with duration of clinical signs; initial or 24-hour neurologic status; or degree of spinal cord compression assessed by MRI. CONCLUSION: SCBF increases immediately after spinal cord decompression in dogs with disk herniation; however, increased SCBF was not associated with a diminished 24-hour neurologic status. CLINICAL RELEVANCE: An increase in SCBF does not appear to be either associated with the degree of spinal cord compression or of a magnitude sufficient to outweigh the benefit of surgical decompression by resulting in clinically relevant changes in 24-hour outcome.
Resumo:
The goal of this study was to investigate the effect of sodium intake on renal tissue oxygenation in humans. To this purpose, we measured renal hemodynamics, renal sodium handling, and renal oxygenation in normotensive (NT) and hypertensive (HT) subjects after 1 week of a high-sodium and 1 week of a low-sodium diet. Renal oxygenation was measured using blood oxygen level-dependent magnetic resonance. Tissue oxygenation was determined by the measurement of R2* maps on 4 coronal slices covering both kidneys. The mean R2* values in the medulla and cortex were calculated, with a low R2* indicating a high tissue oxygenation. Ten male NT (mean age: 26.5+/-7.4 years) and 8 matched HT subjects (mean age: 28.8+/-5.7 years) were studied. Cortical R2* was not different under the 2 conditions of salt intake. Medullary R2* was significantly lower under low sodium than high sodium in both NT and HT subjects (28.1+/-0.8 versus 31.3+/-0.6 s(-1); P<0.05 in NT; and 27.9+/-1.5 versus 30.3+/-0.8 s(-1); P<0.05, in HT), indicating higher medullary oxygenation under low-sodium conditions. In NT subjects, medullary oxygenation was positively correlated with proximal reabsorption of sodium and negatively with absolute distal sodium reabsorption, but not with renal plasma flow. In HT subjects, medullary oxygenation correlated with the 24-hour sodium excretion but not with proximal or with the distal handling of sodium. These data demonstrate that dietary sodium intake influences renal tissue oxygenation, low sodium intake leading to an increased renal medullary oxygenation both in normotensive and young hypertensive subjects.
Resumo:
This study of ambulance workers for the emergency medical services of the City of Houston studied the factors related to shiftwork tolerance and intolerance. The EMS personnel work a 24-hour shift with rotating days of the week. Workers are assigned to A, B, C, D shift, each of which rotate 24-hours on, 24-hours off, 24-hours on and 4 days off. One-hundred and seventy-six male EMTs, paramedics and chauffeurs from stations of varying levels of activity were surveyed. The sample group ranged in age from 20 to 45. The average tenure on the job was 8.2 years. Over 68% of the workers held a second job, the majority of which worked over 20 hours a week at the second position.^ The survey instrument was a 20-page questionnaire modeled after the Folkard Standardized Shiftwork Index. In addition to demographic data, the survey tool provided measurements of general job satisfaction, sleep quality, general health complaints, morningness/eveningness, cognitive and somatic anxiety, depression, and circadian types. The survey questionnaire included an EMS-specific scaler of stress.^ A conceptual model of Shiftwork Tolerance was presented to identify the key factors examined in the study. An extensive list of 265 variables was reduced to 36 key variables that related to: (1) shift schedule and demographic/lifestyle factors, (2) individual differences related to traits and characteristics, and (3) tolerance/intolerance effects. Using the general job satisfaction scaler as the key measurement of shift tolerance/intolerance, it was shown that a significant relationship existed between this dependent variable and stress, number of years working a 24-hour shift, sleep quality, languidness/vigorousness. The usual amount of sleep received during the shift, general health complaints and flexibility/rigidity (R$\sp2$ =.5073).^ The sample consisted of a majority of morningness-types or extreme-morningness types, few evening-types and no extreme-evening types, duplicating the findings of Motohashi's previous study of ambulance workers. The level of activity by station was not significant on any of the dependent variables examined. However, the shift worked had a relationship with sleep quality, despite the fact that all shifts work the same hours and participate in the same rotation schedule. ^
Resumo:
Background. A review of the literature suggests that Hypertension (HTN) in older adults is associated with sympathetic stimulation that results in increasing blood pressure (BP) reactivity. If clinical assessment of BP captured sympathetic stimulation, it would be valuable for hypertension management. ^ Objectives. The study examined whether reactive change scores from a short BPR protocol, resting blood pressure (BP), or resting pulse pressure (PP) is a better predictor of 24 hour ambulatory BP and BP load in cardiac patients. ^ Method. The study used a single-group design, with both an experimental clinical component and an observational field component. Both components used repeated measurement methods. The study population consisted of 45 adult patients with a mean age of 64.6 ± 8.5 years who were diagnosed with cardiac disease and who were taking anti-hypertensive medication. Blood pressure reactivity was operationalized with a speech protocol. During the speech protocol, BP was measured with an automatic device (Dinamap 825XT) while subjects talked about their health and about their usual day. Twenty-four hour ambulatory BP measurement (Spacelabs 90207 monitor) followed the speech protocol. ^ Results. Resting SBP and resting PP were significant predictors of 24-hour SBP, and resting SBP was a significant predictor of SBP load. No predictors were significant of 24-hour DBP or DBP load. ^ Conclusions. Initial resting BP and PP may be used in clinical settings to assess hypertension management. Future studies are necessary to confirm the ability of resting BP to predict ABP and BP load in older, medicated hypertensives. ^
Resumo:
Background. Research investigating symptom management in patients with chronic obstructive pulmonary disease (COPD) largely has been undertaken assuming the homeostatic construct, without regard to potential roles of circadian rhythms. Temporal relations among dyspnea, fatigue, peak expiratory flow rate (PEFR) and objective measures of activity/rest have not been reported in COPD. ^ Objectives. The specific aims of this study were to (1) explore the 24-hour patterns of dyspnea, fatigue, and PEFR in subjects with COPD; (2) examine the relations among dyspnea, fatigue, and PEFR in COPD; and (3) examine the relations among objective measures of activity/rest and dyspnea, fatigue, and PEFR in COPD. ^ Methods. The repeated-measures design involved 10 subjects with COPD who self-assessed dyspnea and fatigue by 100 mm visual analog scales, and PEFR by peak flow meter in their home 5 times a day for 8 days. Activity/rest was measured by wrist actigraphy. Single and population mean cosinor analyses and correlations were computed for dyspnea, fatigue, and PEFR; correlations were done among these variables and activity/rest. ^ Results. Circadian rhythms were documented by single cosinor analysis in 40% of the subjects for dyspnea, 60% for fatigue, and 60% for PEFR. The population cosinor analysis of PEFR yielded a significant rhythm (p < .05). The 8-day 24-hour means of dyspnea and fatigue was moderately correlated (r = .48, p < .01). Dyspnea and PEFR, and fatigue and PEFR, were weakly correlated in a negative way (r = −.11, p < .05 and r = −.15, p < .01 respectively). Weak to moderate correlations (r = .12–.34, p < .05) were demonstrated between PEFR and mean activity level measured up to 4 hours before PEFR measurement. ^ Conclusions. The findings suggest that (1) the dyspnea and fatigue experienced by COPD patients are moderately related, (2) there is a weak to modest positive relation between PEFR and activity levels, and (3) temporal variation in lung function may not affect the dyspnea and fatigue experienced by patients with COPD. Further research, examining the relations among dyspnea, fatigue, PEFR, and activity/rest is needed. Replication of this study is suggested with a larger sample size. ^
Resumo:
Background. Ambulatory blood pressure (ABP) measurement is a means of monitoring cardiac function in a noninvasive way, but little is known about ABP in heart failure (HF) patients. Blood pressure (BP) declines during sleep as protection from consistent BP load, a phenomenon termed "dipping." The aims of this study were (1) to compare BP dipping and physical activity between two groups of HF patients with different functional statuses and (2) to determine whether the strength of the association between ambulatory BP and PA is different between these two different functional statuses of HF. ^ Methods. This observational study used repeated measures of ABP and PA over a 24-hour period to investigate the profiles of BP and PA in community-based individuals with HF. ABP was measured every 30 minutes by using a SpaceLabs 90207, and a Basic Motionlogger actigraph was used to measure PA minute by minute. Fifty-six participants completed both BP and physical activity for a 24-hour monitoring period. Functional status was based on New York Heart Association (NYHA) ratings. There were 27 patients with no limitation of PA (NYHA class I HF) and 29 with some limitation of PA but no discomfort at rest (NYHA class II or III HF). The sample consisted of 26 men and 30 women, aged 45 to 91 years (66.96 ± 12.35). ^ Results. Patients with NYHA class I HF had significantly greater dipping percent than those with NYHA class II/III HF after controlling their left ventricular ejection fraction (LVEF). In a mixed model analysis (PROC MIXED, SAS Institute, v 9.1), PA was significantly related to ambulatory systolic and diastolic BP and mean arterial pressure. The strength of the association between PA and ABP readings was not significantly different for the two groups of patients. ^ Conclusions. These preliminary findings demonstrate differences between NYHA class I and class II/III of HF in BP dipping status and ABP but not PA. Longitudinal research is recommended to improve understanding of the influence of disease progression on changes in 24-hour physical activity and BP profiles of this patient population. ^ Key Words. Ambulatory Blood Pressure; Blood Pressure Dipping; Heart Failure; Physical Activity. ^
Resumo:
Introduction: Assessment of expertise in regional anesthesia techniques is traditionally based upon quota fulfillment of procedures during training. Validation of practitioner proficiency in performing procedures in surgical specialties has moved from simple measurement of technical skills to evaluation of global patient outcomes. Complete absence of pain as a result of nerve blockade is the most important clinical endpoint but patient, technical and procedural factors influence results. The purpose of this study was to measure the postoperative pain scores and associated analgesic medication requirements for patients administered sciatic nerve blockade by nurse anesthetists and determine patient or procedural factors that influenced this outcome. Methods: Either nerve stimulator or ultrasound guided sciatic nerve blockade was administered by nurse anesthetists under the supervision of regional anesthesia faculty. Patient demographic data that was collected included gender, body mass index, surgical procedure, and pre-existing chronic pain with associated opioid use. Patient self-reported pain scores and opioid analgesic dosages in the preoperative, intraoperative, immediate postoperative and 24 hour post procedure intervals were recorded. Results: 22 nurse anesthetists administered sciatic nerve blockade to 48 patients during a 36 month interval. Transition from a nerve stimulator to ultrasound guided sciatic nerve block technique resulted in lower mean pain scores. Patients reporting chronic opioid use were observed to have elevated perioperative opioid analgesic requirements and pain scores compared to opioid naïve patients. Conclusion: Effective analgesia is a prime measure for assessing expertise in regional anesthesia and continuous evaluation of this outcome in everyday practice is proposed.
Resumo:
It is unclear whether a random plasma cortisol measurement and the corticotropin (ACTH) test adequately reflect glucocorticoid secretory capacity in critical illness. This study aimed to determine whether these tests provide information representative of the 24 hour period. Plasma cortisol was measured hourly for 24 hours in 21 critically ill septic patients followed by a corticotropin test with 1 μ g dose administered intravenously. Serum and urine were analysed for ACTH and free cortisol respectively. Marked hourly variability in plasma cortisol was evident (coefficient of variation 8-30%) with no demonstrable circadian rhythm. The individual mean plasma cortisol concentrations ranged from 286 59 nmol/l to 796 &PLUSMN; 83 nmol/l. The 24 hour mean plasma cortisol was strongly correlated with both random plasma cortisol (r(2) 0.9, P< 0.0001) and the cortisol response to corticotropin (r(2) 0.72, P< 0.001). Only nine percent of patients increased their plasma cortisol by 250 nmol/l after corticotropin (euadrenal response). However, 35% of non-responders had spontaneous hourly rises > 250 nmol/l thus highlighting the limitations of a single point corticotropin test. Urinary free cortisol was elevated (865&PLUSMN; 937 nmol) in both corticotropin responders and non-responders suggesting elevated plasma free cortisol. No significant relationship was demonstrable between plasma cortisol and ACTH. We conclude that although random cortisol measurements and the low dose corticotropin tests reliably reflect the 24 hour mean cortisol in critical illness, they do not take into account the pulsatile nature of cortisol secretion. Consequently, there is the potential for erroneous conclusions about adrenal function based on a single measurement. We suggest that caution be exercised when drawing conclusions on the adequacy of adrenal function based on a single random plasma cortisol or the corticotropin test.
Resumo:
In this study, the effect of anti-corrosion inhibitor addition to epoxy coating, on the disbanding rate was evaluated. First to determination of mechanism, the bare steel substrates were immersed in the 3.5% NaCl solution and the solution containing 1 mM anti corrosion. The Electrochemical Impedance Spectroscopy was performed after 5 and 24 hour. The results indicated a lower corrosion rate in the presence of inhibitor. During the time, charge transfer resistance, was decreased for the substrates immersed in NaCl solution, and increased for the substrates immersed in NaCl solution containing 1 mM anti corrosion. This result can be related to more stability of corrosion products in presence of anti-corrosion and film formation. The coated substrates, with four different concentration of anticorrosion in coating, were protected under -1.2 voltage in the 3.5% NaCl solution. After 12 and 24 hour, the EIS test and disbanding area measurement, were evaluate. The lower disbanding rate, more charge transfer resistance and less double layer capacitance for the coating containing 0.75w% inhibitor, were observed. The result of Pull-off test after 1 day immersion in 3.5% NaCl solution, showed more wet adhesion for the coating containing 0.75w% inhibitor. The images of FE-SEM electron microscope and surface analyses EDX on the coated substrate after disbanding and the bare substrate immersed in 3.5w% NaCl containing 1 mM inhibitor, were proved the formation of stabilized film.
Resumo:
Oscillometric blood pressure (BP) monitors are currently used to diagnose hypertension both in home and clinical settings. These monitors take BP measurements once every 15 minutes over a 24 hour period and provide a reliable and accurate system that is minimally invasive. Although intermittent cuff measurements have proven to be a good indicator of BP, a continuous BP monitor is highly desirable for the diagnosis of hypertension and other cardiac diseases. However, no such devices currently exist. A novel algorithm has been developed based on the Pulse Transit Time (PTT) method, which would allow non-invasive and continuous BP measurement. PTT is defined as the time it takes the BP wave to propagate from the heart to a specified point on the body. After an initial BP measurement, PTT algorithms can track BP over short periods of time, known as calibration intervals. After this time has elapsed, a new BP measurement is required to recalibrate the algorithm. Using the PhysioNet database as a basis, the new algorithm was developed and tested using 15 patients, each tested 3 times over a period of 30 minutes. The predicted BP of the algorithm was compared to the arterial BP of each patient. It has been established that this new algorithm is capable of tracking BP over 12 minutes without the need for recalibration, using the BHS standard, a 100% improvement over what has been previously identified. The algorithm was incorporated into a new system based on its requirements and was tested using three volunteers. The results mirrored those previously observed, providing accurate BP measurements when a 12 minute calibration interval was used. This new system provides a significant improvement to the existing method allowing BP to be monitored continuously and non-invasively, on a beat-to-beat basis over 24 hours, adding major clinical and diagnostic value.
Resumo:
Introducción Los sistemas de puntuación para predicción se han desarrollado para medir la severidad de la enfermedad y el pronóstico de los pacientes en la unidad de cuidados intensivos. Estas medidas son útiles para la toma de decisiones clínicas, la estandarización de la investigación, y la comparación de la calidad de la atención al paciente crítico. Materiales y métodos Estudio de tipo observacional analítico de cohorte en el que reviso las historias clínicas de 283 pacientes oncológicos admitidos a la unidad de cuidados intensivos (UCI) durante enero de 2014 a enero de 2016 y a quienes se les estimo la probabilidad de mortalidad con los puntajes pronósticos APACHE IV y MPM II, se realizó regresión logística con las variables predictoras con las que se derivaron cada uno de los modelos es sus estudios originales y se determinó la calibración, la discriminación y se calcularon los criterios de información Akaike AIC y Bayesiano BIC. Resultados En la evaluación de desempeño de los puntajes pronósticos APACHE IV mostro mayor capacidad de predicción (AUC = 0,95) en comparación con MPM II (AUC = 0,78), los dos modelos mostraron calibración adecuada con estadístico de Hosmer y Lemeshow para APACHE IV (p = 0,39) y para MPM II (p = 0,99). El ∆ BIC es de 2,9 que muestra evidencia positiva en contra de APACHE IV. Se reporta el estadístico AIC siendo menor para APACHE IV lo que indica que es el modelo con mejor ajuste a los datos. Conclusiones APACHE IV tiene un buen desempeño en la predicción de mortalidad de pacientes críticamente enfermos, incluyendo pacientes oncológicos. Por lo tanto se trata de una herramienta útil para el clínico en su labor diaria, al permitirle distinguir los pacientes con alta probabilidad de mortalidad.
Resumo:
While there is growing use of online counselling, little is known about its interactional organisation and how it compares to telephone counselling. This is despite past research suggesting that both counsellors and clients report the impact of the different modalities on the presentation and management of the counselling interaction. This paper compares the interactional affordances of telephone and online web counselling in opening sequences on Kids Help Line, a 24-hour Australian counselling service for children and young people up to the age of 25. We examine two ways that counsellors show active listening through response tokens and formulations. The analysis describes how counsellors’ use of minimal response tokens facilitate the clients’ problem presentation and are used in the management of turn taking and sequence organisation. For example, counsellors use the response token Mm hm to show that they understand that the client’s unit of talk to is not yet complete, and to affirm or invite the client to continue speaking. Formulations in phone and web counselling are another way that counsellors display active listening to re-present stretches of the clients’ preceding talk. In phone and web counselling, however, the respective modalities can complicate matters of turn transition and sequence organisation. By examining actual phone and online counselling sessions, this paper offers empirical demonstrations of the interactional affordances of phone and online counselling, and shows how the institutional practice of active listening is accomplished across different counselling modalities
Resumo:
Background Takeaway consumption has been increasing and may contribute to socioeconomic inequalities in overweight/obesity and chronic disease. This study examined socioeconomic differences in takeaway consumption patterns, and their contributions to dietary intake inequalities. Method Cross-sectional dietary intake data from adults aged between 25 and 64 years from the Australian National Nutrition Survey (n= 7319, 61% response rate). Twenty-four hour dietary recalls ascertained intakes of takeaway food, nutrients and fruit and vegetables. Education was used as socioeconomic indicator. Data were analysed using logistic regression and general linear models. Results Thirty-two percent (n = 2327) consumed takeaway foods in the 24 hour period. Lower-educated participants were less likely than their higher-educated counterparts to have consumed total takeaway foods (OR 0.64; 95% CI 0.52, 0.80). Of those consuming takeaway foods, the lowest-educated group was more likely to have consumed “less healthy” takeaway choices (OR 2.55; 95% CI 1.73, 3.77), and less likely to have consumed “healthy” choices (OR 0.52; 95% CI 0.36, 0.75). Takeaway foods made a greater contribution to energy, total fat, saturated fat, and fibre intakes among lower than higher-educated groups. Lower likelihood of fruit and vegetable intakes were observed among “less healthy” takeaway consumers, whereas a greater likelihood of their consumption was found among “healthy” takeaway consumers. Conclusions Total and the types of takeaway foods consumed may contribute to socioeconomic inequalities in intakes of energy, total and saturated fats. However, takeaway consumption is unlikely to be a factor contributing to the lower fruit and vegetable intakes among socioeconomically-disadvantaged groups.