996 resultados para self-etching adhesive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the bond strength of two etch-and-rinse adhesive systems (two- and three-step) and a self-etching system to Coronal and root canal dentin.Materials and Methods: The root canals of 30 human incisors and canines were instrumented and prepared with burs. The posts used for luting were duplicated with dual resin cement (Duo-link) inside Aestheti Plus #2 molds. Thus, three groups were formed (n = 10) according to the adhesive system employed: All-Bond 2 (TE3) + resin cement post (rcp) + Duo-link (DI); One-Step Plus (TE2) + rcp + DI; Tyrian/One-Step Plus (SE) + rcp + DI. Afterwards, 8 transverse sections (1.5 mm) were cut from 4 mm above the CEJ up to 4 mm short of the root canal apex, comprising coronal and root canal dentin. The sections were submitted to push-out testing in a universal testing machine EMIC (1 mm/min). Bond strength data were analyzed with two-way repeated measures ANOVA and Tukey's test (p < 0.05).Results: The relationship between the adhesives was not the same in the different regions (p < 0.05). Comparison of the means achieved with the adhesives in each region (Tukey; p < 0.05) revealed that TE3 (mean standard deviation: 5.22 +/- 1.70) was higher than TE2 (2.60 +/- 1.74) and SE (1.68 +/- 1.85).Conclusion: Under the experimental conditions, better bonding to dentin was achieved using the three-step etch-and-rinse system, especially in the coronal region. Therefore, the traditional etch-and-rinse three-step adhesive system seems to be the best choice for teeth needing adhesive endodontic restorations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the 1-year clinical performance of three self-etching adhesives (Adper Prompt L-Pop, Clearfil S-3 Bond, iBond) in posterior composite restorations using one etch&rinse adhesive (One-Step Plus) as control. Methods: Upon approval by the Institutional Review Board, 121 restorations were inserted in 38 subjects. The adhesives were applied as per manufacturers' instructions. Preparations were restored with a nanofilled resin composite (Filtek Supreme) and evaluated at baseline, 6 months, and 1 year. Statistical analyses included the Chi-square distribution with the McNemar non-parametric test (P< 0.05). Results: At 1 year, 111 restorations in 35 subjects were evaluated using the USPHS modified criteria. No significant changes were observed for the etch&rinse adhesive One-Step Plus. At 1 year the number of Alfa ratings decreased significantly for Clearfil S-3 Bond and for iBond in the categories color match, marginal staining, and marginal adaptation. For Adper Prompt L-Pop, marginal adaptation at 1 year was significantly worse than at baseline. Postoperative sensitivity to air improved significantly for Adper Prompt L-Pop, Clearfil S-3 Bond, and iBond. When the evaluation criteria were paired at 1 year, iBond resulted in a significantly lower number of Alfa ratings than any of the other adhesives for color match, marginal staining, and marginal adaptation. One-Step Plus resulted in a greater number of Alfa ratings for marginal adaptation than either Adper Prompt L-Pop or Clearfil S-3 Bond. Marginal adaptation was significantly better for Clearfil S-3 Bond than for Adper Prompt L-Pop. The post-operative sensitivity measured at 1 year for Adper Prompt L-Pop was statistically better than that for One-Step Plus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the microleakage of four hydrophilic adhesive systems: one multiple-bottles (Scotchbond Multi-Purpose Plus); two one-bottle (Single Bond, Stae); and one self-etching (Etch & Prime 3.0). Materials and Methods: 120 bovine incisor teeth were divided into four groups (n = 30) and Class V cavities were prepared at the cemento-enamel junction. The cavities were restored with the adhesive systems and with Z100 composite. The teeth were thermocycled 1,000 times between 5 +/- 2 degreesC and 55 +/- 2 degreesC with a dwell time of 1 min, and then placed in a 2% methylene blue dye (pH 7.0) for 4 hrs, washed and sectioned vertically through the center of the restorations. The qualitative evaluation was made by three examiners who distributed pre-established scores (0-4) for each tooth using a stereomicroscope at x30 magnification. Results: In enamel margins little microleakage was observed and the Kruskal-Wallis analysis did not show differences. In dentin margins the KruskaI-Wallis and multiple comparison analyses were applied: microleakage was significantly greater with Stae (median 3) and Scotchbond MP Plus (median 4). Single Bond (median 1) and Etch & Prime 3.0 (median 2) showed the best results in dentin margins, and the statistical analysis did not demonstrate differences in microleakage among these groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of intrapulpal pressure and dentin depth on bond strengths of an etch-and-rinse and a self-etching bonding agent to dentin in vitro and in vivo. Twenty-four pairs of premolars were randomly divided into four groups (n = 6) according to the dentin bonding agent, Single Bond and Clearfil SE Bond, and intrapulpal pressure, null or positive. Each tooth of the pair was further designated to be treated in vivo or in vitro. The intrapulpal pressure was controlled in vivo by the delivery of local anesthetics containing or not a vasoconstrictor, while in vitro, it was achieved by keeping the teeth under hydrostatic pressure. Class I cavities were prepared and the dentin bonding agents were applied followed by incremental resin restoration. For the teeth treated in vitro, the same restorative procedures were performed after a 6 month-storage period. Beams with I mm 2 cross-sectional area were prepared and, microtensile tested. Clearfil SE Bond was not influenced by any of the variables of the study, while bond strengths produced in vitro were significatly higher for Single Bond. Overall, lower bond strengths were produced in deep dentin, which reached statistical significance when Single Bond was applied under physiological or simulated intrapulpal pressure. In conclusion, in vitro bonding may overestimate the immediate adhesive performance of more technique-sensitive dentin bonding systems. The impact of intrapulpal pressure on bond strength seems to be more adhesive dependent than dentin morphological characteristics related to depth. (C) 2007 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acid etching promotes microporosities on enamel surface, which provide a better bonding surface to adhesive materials. The purpose of this study was to comparatively analyze the microstructure of enamel surface after etching with 37% phosphoric acid or with two self-etching primers, Non-rinse conditioner (NRC) and Clearfil SE Bond (CSEB) using scanning electron microscopy. Thirty sound premolars were divided into 3 groups with ten teeth each: Group 1: the buccal surface was etched with 37% phosphoric acid for 15 seconds; Group 2: the buccal surface was etched with NRC for 20 seconds; Group 3: the buccal surface was etched with CSEB for 20 seconds. Teeth from Group 1 were rinsed with water; teeth from all groups were air-dried for 15 seconds. After that, all specimens were processed for scanning electron microscopy and analyzed in a Jeol 6100 SEM. The results showed deeper etching when the enamel surface was etched with 37% phosphoric acid, followed by NRC and CSEB. It is concluded that 37% phosphoric acid is still the best agent for a most effective enamel etching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the tensile bond strength of adhesive systems in abraded enamel and deep dentin of the occlusal surface of forty human molar teeth. Enamel surfaces as well as the rest of the teeth were coated with epoxy resin and regularized and polished with silicon carbide sandpapers. The 40 teeth were randomized into eight groups of five teeth per group. Four groups were assigned to have deep dentin as the dental substrate and the other four had abraded enamel as the substrate for the adhesives to be tested. The adhesives being tested were the total etching Single Bond: SB, the self-etching Clearfil SE bond: CSEB, self-etching One Up Bond F: OUBF and the self-etching Self-Etch Bond: SEB adhesives. The samples (teeth) were restored with composite resin and subjected to a traction assay. The results were statistically analyzed using the ANOVA and TUKEY tests. The total etching SB adhesive system had the greatest bonding strength of all the adhesives tested, on both dental substrates (20.1 MegaPascals (MPa) on abraded enamel and 19.4 MPa on deep dentin). Of the self-etching dental adhesives tested, CSEB had the greatest bonding strength on both substrates (14.6 MPa on abraded enamel and 15.4 MPa on deep dentin). Both OUBF (11.0 MPa for enamel, 13.1 MPa for dentin) and SEB (10.2 MPa for enamel, 12.6 MPa for dentin) showed comparable bonding strengths without any significant differences for either substrate Thus, the total etching SB adhesive system had better bonding strength than the other self-etching adhesives used, regardless of the dental substrate to which the adhesives had been bonded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the arrival of self-etch adhesives systems, there has been a rise in interest among clinicians, making it imperative for health professionals to have knowledge of the properties, characteristics, the association as well as the dental structures of these materials, in order to select them and use them correctly. The self-etch adhesive systems show good values of bond strength, microleakage and performance, and have therefore become an option in direct adhesive restorations. In the regard, this case study aims to describe the technique involving the use of selfetch adhesives system for direct restoration of anterior teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the effects of surface treatment, surface hydration (SH) and application method (AM) on the tensile bond strength of the Silorane Adhesive System (SAS) to dentine. Methods: Ninety bovine teeth were used. For the control group (n = 10), each dentine surface was treated according to the manufacturer's instructions of the SAS. The remaining teeth were randomly distributed into two groups (n = 40), according to the type of dentine surface treatment (ST) - 37% phosphoric acid or Er:YAG Laser prior to the application of the SAS. Each group was further divided into 2 subgroups (n = 20), according to the SH status: dry (D) or wet (W). Each subgroup was further divided into 2 subgroups (n = 10), according to the application method [AM: Active (AC) mode or Passive (PA) mode]. A coat of resin composite (Filtek P90) was applied on the surface. Artificial ageing was performed with a thermo-mechanical cycling machine. The specimens were sectioned into 1 mm × 1 mm × 10 mm sticks and stressed to failure using a universal testing machine. The remaining teeth in each group were used for Scanning Electron Microscopy to examine the fractured area. Data were subjected to a three-way ANOVA, Tukey's test and Dunnet's test (α = 0.05). Results: The ANOVA showed significant differences for SH and AM, but not for ST. For SH, the results of Tukey's test were (in MPa): D-14.9(±3.8)a, W-17.1(±4.3)b; and for AM: PA-14. 9(±4.2)a, AC-17.1(±3.9) b. Conclusions: Acid etching, when combined with a moist dentine surface and the use of primer agitation, improves the bond strength of the SAS to dentine. Clinical Significance: According to the results of the present in vitro study, modification of the application protocols for the silorane-based adhesive system may improve its clinical performance. © 2012 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the transdentinal cytotoxicity of experimental adhesive systems (EASs) with different hydrophilicity and dentin saturation solutions on odontoblast-like cells. One hundred 0.4-mm-thick dentin discs were mounted in in vitro pulp chambers and assigned to 10 groups. MDPC-23 cells were seeded onto the pulpal side of the discs, incubated for 48 h. The EASs with increasing hydrophilicity (R1, R2, R3 and R4) were applied to the occlusal side after etching and saturation of etched dentin with water or ethanol. R0 (no adhesive) served as controls. R1 is a non-solvated hydrophobic blend, R2 is similar to a simplified etch-and-rinse adhesive system and R3 and R4 are similar to self-etching adhesives. After 24 h, cell metabolism was evaluated by MTT assay (n = 8 discs) and cell morphology was examined by SEM (n = 2 discs). Type of cell death was identified by flow cytometry and the degree of monomer conversion (%DC) was determined by infrared spectroscopy (FTIR) after 10 s or 20 s of photoactivation. Data were analyzed by the Kruskal-Wallis and Mann-Whitney tests (α = 0.05). Dentin saturation with ethanol resulted in higher necrotic cell death ratios for R2, R3 and R4 compared with water saturation, although R2 and R3 induced higher SDH production. Photoactivation for 20 s significantly improved the %DC of all EASs compared with 10 s. A significant positive correlation was observed between the degree of hydrophilicity and %DC. In conclusion, except for R1, dentin saturation with ethanol increased the cytotoxicity of EASs, as expressed by the induction of necrotic cell death. © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O uso de primers autocondicionantes e de bráquetes com compósito pré-incorporado tem sido apresentado como uma alternativa para a redução de passos clínicos. O propósito deste estudo foi avaliar o efeito de um primer autocondicionante (Transbond Plus Self-Etching Primer - SEP) na resistência ao cisalhamento de bráquetes com compósito pré-incorporado colados in vivo. A amostra consistiu de 92 dentes obtidos de 23 pacientes com indicação prévia de extração de 4 pré-molares. Os dentes foram divididos em 4 grupos, sendo os bráquetes colados pelo mesmo operador, alternando os quadrantes em cada paciente: Grupo 1 (controle) - Ácido fosfórico à 37% + primer (Transbond XT Primer) + compósito (Transbond XT Adhesive Paste) + bráquete convencional; Grupo 2 - Ácido fosfórico à 37% + primer + bráquete com compósito pré-incorporado; Grupo 3 SEP + compósito + bráquete convencional; Grupo 4 - SEP + bráquete com compósito pré-incorporado. Após 30 dias os pré-molares foram extraídos, sendo submetidos ao teste de resistência ao cisalhamento através da uma Máquina de Ensaios Universal, com velocidade de 0,5mm/min. Os dados obtidos pelos grupos foram analisados com 2-way ANOVA (p<0,05). As forças médias e desvios padrão obtidos foram os seguintes: Grupo 1 = 11,35 (2,36) MPa; Grupo 2 = 9,77 (2,49) MPa; Grupo 3 = 10,89 (2,60) MPa; e Grupo 4 = 10,16 (2,75) MPa. Não foi observada diferença significativa entre o uso do SEP e o de condicionador e primer tradicionais (p = 0,948). De qualquer modo, diferenças significativas na força de adesão foram observadas quando utilizados bráquetes com compósito pré-incorporado (p = 0,032). Pode ser concluído que a combinação do primer autocondicionante com o bráquete com compósito pré-incorporado apresentou valores de força de adesão adequados, sendo promissora para uso clínico.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O uso de primers autocondicionantes tem sido proposto como uma alternativa para a redução de passos clínicos. O objetivo deste estudo clínico aleatório e controlado foi avaliar a performance de um sistema autocondicionante (Transbond Plus Self-Etching Primer, 3M Unitek - SEP) comparado a um sistema multipasso convencional (Transbond XT, 3M Unitek - TBXT) de colagem ortodôntica, durante um período de 12 meses. Vinte e oito pacientes participaram deste estudo, sendo estes alocados aos grupos SEP ou TBXT de forma aleatória, através de randomização em bloco. Um total de 548 bráquetes metálicos (Micro-Arch, prescrição Alexander, GAC International, Bohemia, NY) foram colados com uso da pasta adesiva Transbond XT (3M Unitek), sendo todos os produtos manuseados de acordo com as recomendações dos fabricantes. Foram totalizados 276 bráquetes no grupo controle e 272 no segundo. Curvas de sobrevivência Kaplan-Meier e o teste log-rank (p<0,05) foram utilizados para comparar o percentual de falhas adesivas para as duas técnicas. Ao final do período foram verificadas trinta e duas falhas adesivas (bráquetes descolados), sendo 19 (6,98%) falhas quando utilizado o primer autocondicionante (SEP) e 13 (4,71%) quando usado o primer convencional (TBXT). Não houve diferença significante entre a sobrevivência dos bráquetes entre os dois grupos avaliados (log-rank test, p=0,311). Quando a influência de gênero do paciente, arco dentário e tipo dentário (anterior ou posterior) foram analisados, somente o tipo dentário foi achado significante. Bráquetes de dentes posteriores apresentaram uma maior probabilidade de falha adesiva que os colados em dentes anteriores (p=0,013) Os autores concluem que o primer autocondicionante pode ser utilizado para colagem direta de bráquetes ortodônticos sem que sua sobrevivência clínica seja afetada.