798 resultados para rib hump measurement
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: Severe glottic/subglottic stenosis (complex laryngotracheal stenosis) is a rare but challenging complication of endotracheal intubation. Laryngotracheal reconstruction with cartilage graft and an intralaryngeal stent is a procedure described for complex laryngotracheal stenosis management in children; however, for adults, few options remain. Our aim was to analyze the results of laryngotracheal reconstruction as a treatment for complex laryngotracheal stenosis in adults, considering postoperative and long-term outcome. Methods: Laryngotracheal reconstruction (laryngeal split with anterior and posterior interposition of a rib cartilage graft) has been used in our institution to manage glottic/subglottic stenosis restricted to the larynx; laryngotracheal reconstruction associated with cricotracheal resection has been used to treat glottic/subglottic/upper tracheal stenosis (extending beyond the second tracheal ring). A retrospective study was conducted, including all patients with complex laryngotracheal stenosis treated surgically in our institution from January of 2002 until December of 2005. Results: Twenty patients (10 male and 10 female patients; average age, 36.13 years; age range, 18-54 years) were included. There were no deaths, and the postoperative complications were as follows: dysphonia, 25%; subcutaneous emphysema, 10%; tracheocutaneous fistula, 20%; wound infection, 15%; and bleeding, 5.0%. Eighty percent of the patients were completely decannulated after a mean of 23.4 months of follow-up (range, 4 -55 months). Conclusions: Laryngeal split with anterior and posterior cartilage graft interposition as an isolated procedure or associated with a cricotracheal resection is a feasible and low-morbidity alternative for complex laryngotracheal stenosis treatment.
Resumo:
An asymptomatic 48-year-old woman presented to our hospital with a tumor of the rib incidentally diagnosed on a chest roentgenogram. The patient was investigated and underwent tumor resection of the chest wall. The pathologic study revealed that it was cavernous hemangioma. This tumor of the bone is a distinctly uncommon benign vascular tumor, generally occurring in the spine or skull. Hemangiomas involving the rib are even more rare, with only 22 cases described in the literature. However, we suggest that this tumor of the rib should be considered in the differential diagnosis, principally in asymptomatic patients. (Ann Thorac Surg 2011;91:595-6) (C) 2011 by The Society of Thoracic Surgeons
Resumo:
Background: Shrimp is a frequent cause of food allergy. Tropomyosin is the major allergen in shrimp, and it shares homology to tropomyosins from other crustaceans, dust mites, cockroach, and parasites. Objective: The aim of this study was to determine the value of detection of IgE to shrimp tropomyosin in the diagnosis of shrimp allergy. Methods: We have studied 35 patients with asthma, rhinitis, or both who were sensitized to Dermatophagoides pteronyssinus. All subjects underwent skin prick testing in addition to double-blind, placebo-controlled food challenges (DBPCFC); oral open challenges; or both with shrimp. Measurements of IgE to shrimp and shrimp tropomyosin were carried out by means of CAP and chimeric ELISA, respectively. Results: Oral challenges confirmed the diagnosis of shrimp allergy in 7 patients. IgE measurement to shrimp tropomyosin was positive in 71.4% of the patients with shrimp allergy. Of the 28 patients without shrimp allergy, only 7.1% (2/28) had IgE to shrimp tropomyosin compared with 25% (7/28) who had IgE to shrimp and 35.7% (10/28) who had positive skin prick test responses to shrimp. Sensitivity was similar for all 3 methods (71.4%); in contrast, specificity of IgE to shrimp tropomyosin (92.8%) was greater than that of IgE to shrimp (75%) and skin prick testing (64.2%). With regard to diagnostic efficiency, measurement of IgE to shrimp tropomyosin was superior to measurement of IgE to shrimp and skin prick testing (88.5%, 74.2%, and 65.7%, respectively). Conclusion: Use of measurements of IgE to shrimp tropomyosin provided added value to the diagnosis of shrimp allergy. (J Allergy Clin Immunol 2010;125:872-8.)
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.