936 resultados para reliability measurement
Resumo:
The real-time monitoring of events in an industrial plant is vital, to monitor the actual conditions of operation of the machinery responsible for the manufacturing process. A predictive maintenance program includes condition monitoring of the rotating machinery, to anticipate possible conditions of failure. To increase the operational reliability it is thus necessary an efficient tool to analyze and monitor the equipments, in real-time, and enabling the detection of e.g. incipient faults in bearings. To fulfill these requirements some innovations have become frequent, namely the inclusion of vibration sensors or stator current sensors. These innovations enable the development of new design methodologies that take into account the ease of future modifications, upgrades, and replacement of the monitored machine, as well as expansion of the monitoring system. This paper presents the development, implementation and testing of an instrument for vibration monitoring, as a possible solution to embed in industrial environment. The digital control system is based on an FPGA, and its configuration with an open hardware design tool is described. Special focus is given to the area of fault detection in rolling bearings. © 2012 IEEE.
Resumo:
Includes bibliography
Resumo:
ABSTRACT Background: Patients with dementia may be unable to describe their symptoms, and caregivers frequently suffer emotional burden that can interfere with judgment of the patient's behavior. The Neuropsychiatric Inventory-Clinician rating scale (NPI-C) was therefore developed as a comprehensive and versatile instrument to assess and accurately measure neuropsychiatric symptoms (NPS) in dementia, thereby using information from caregiver and patient interviews, and any other relevant available data. The present study is a follow-up to the original, cross-national NPI-C validation, evaluating the reliability and concurrent validity of the NPI-C in quantifying psychopathological symptoms in dementia in a large Brazilian cohort. Methods: Two blinded raters evaluated 312 participants (156 patient-knowledgeable informant dyads) using the NPI-C for a total of 624 observations in five Brazilian centers. Inter-rater reliability was determined through intraclass correlation coefficients for the NPI-C domains and the traditional NPI. Convergent validity included correlations of specific domains of the NPI-C with the Brief Psychiatric Rating Scale (BPRS), the Cohen-Mansfield Agitation Index (CMAI), the Cornell Scale for Depression in Dementia (CSDD), and the Apathy Inventory (AI). Results: Inter-rater reliability was strong for all NPI-C domains. There were high correlations between NPI-C/delusions and BPRS, NPI-C/apathy-indifference with the AI, NPI-C/depression-dysphoria with the CSDD, NPI-C/agitation with the CMAI, and NPI-C/aggression with the CMAI. There was moderate correlation between the NPI-C/aberrant vocalizations and CMAI and the NPI-C/hallucinations with the BPRS. Conclusion: The NPI-C is a comprehensive tool that provides accurate measurement of NPS in dementia with high concurrent validity and inter-rater reliability in the Brazilian setting. In addition to universal assessment, the NPI-C can be completed by individual domains. © International Psychogeriatric Association 2013.
Resumo:
Many epidemiological studies and clinical trials have been performed concerning actinic keratoses. The most eligible endpoint in the majority of articles is counting of actinic keratoses before and after treatments, nevertheless some authors support that this is not a reliable form of evaluation. The aim of this study was to evaluate the actinic keratoses counting by various raters and suggest approaches to increase the reliability. Cross-sectional study: forty-three patients were evaluated by four raters (inter- and intra-rater assessment) on the face and forearms. The mean actinic keratoses counts on the face and forearms were 7.7 and 9.1. The overall agreement among the raters for the facial and forearm actinic keratoses was 0.74 and 0.77. The intra-rater assessment showed high rates of agreement for the face (ICC = 0.93) and forearms (ICC = 0.83). Higher agreement occurred when counting up to five lesions. Four raters led to increased measurement variability and loss of reliability. Higher rates of agreement may be achieved with small number of lesions, limitation and/or segmentation of body areas to reduce their number, in AK prevention designs, are strategies that may lead to a greater reliability of these measurements. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.
Resumo:
Nowadays, the zinc oxide surge arresters (ZnO) are widely used in power systems, however, a large number of silicon carbide surge arresters (SiC) are still in service in the utilities. On the other hand, it is not possible to replace all SiC surge arresters in a short time period, being necessary to review the maintenance program taking into account the surge arresters that are more degraded. In this context, a research project was established between the University of Sao Paulo and the electrical utility CTEEP, aiming the investigation of its SiC surge arresters. This work shows that the leakage current measurement, a diagnostic method for the ZnO surge arresters, can provide useful information related to the condition of the SiC surge arresters. Analysis of the amplitude and distortion of the leakage current, also considering thermovision measurements, resulted in better evaluation of the SiC surge arresters.
Resumo:
The use of patient-orientated questionnaires is of utmost importance in assessing the outcome of spine surgery. Standardisation, using a common set of outcome measures, is essential to aid comparisons across studies/in registries. The Core Outcome Measures Index (COMI) is a short, multidimensional outcome instrument validated for patients with spinal disorders. This study aimed to produce a Brazilian-Portuguese version of the COMI. A cross-cultural adaptation of the COMI into Brazilian-Portuguese was carried out using established guidelines. 104 outpatients with chronic LBP (> 3 months) were recruited from a Public Health Spine Medical Care Centre. They completed a questionnaire booklet containing the newly translated COMI, and other validated symptom-specific questionnaires: Oswestry Disability Index (ODI) and Roland Morris disability scale (RM), and a pain visual analogue scale. All patients completed a second questionnaire within 7-10 days to assess reproducibility. The COMI summary score displayed minimal floor and ceiling effects. On re-test, the responses for each individual domain of the COMI were within 1 category in 98% patients for the domain 'function', 96% for 'symptom-specific well-being', 97% for 'general quality of life', 99% for 'social disability' and 100% for 'work disability'. The intraclass correlation coefficients (ICC2,1) for COMI pain and COMI summary scores were 0.91-0.96, which compared favourably with the corresponding values for the RM (ICC, 0.99) and ODI (ICC, 0.98). The standard error of measurement for the COMI was 0.6, giving a "minimum detectable change" (MDC95%) of approximately 1.7 points i.e., the minimum change to be considered "real change" beyond measurement error. The COMI scores correlated as hypothesised (Rho, 0.4-0.8) with the other symptom-specific questionnaires. The reproducibility of the Brazilian-Portuguese version of the COMI was comparable to that of other language versions. The COMI scores correlated in the expected manner with existing but longer symptom-specific questionnaires suggesting good convergent validity for the COMI. The Brazilian-Portuguese COMI represents a valuable tool for Brazilian study-centres in future multicentre clinical studies and surgical registries.
Resumo:
Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.
Resumo:
Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Resumo:
INTRODUCTION: Schizophrenia is a chronic mental disorder associated with impairment in social functioning. The most widely used scale to measure social functioning is the GAF (Global Assessment of Functioning), but it has the disadvantage of measuring at the same time symptoms and functioning, as described in its anchors. OBJECTIVES:Translation and cultural adaptation of the PSP, proposing a final version in Portuguese for use in Brazil. METHODS: We performed five steps: 1) translation; 2) back translation; 3) formal assessment of semantic equivalence; 4) debriefing; 5) analysis by experts. Interrater reliability (Intraclass correlation, ICC) between two raters was also measured. RESULTS: The final version was applied by two independent investigators in 18 adults with schizophrenia (DSM-IV-TR). The interrater reliability (ICC) was 0.812 (p < 0.001). CONCLUSION: The translation and adaptation of the PSP had an adequate level of semantic equivalence between the Portuguese version and the original English version. There were no difficulties related to understanding the content expressed in the translated texts and terms. Its application was easy and it showed a good interrater reliability. The PSP is a valid instrument for the measurement of personal and social functioning in schizophrenia.
Resumo:
The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.
Resumo:
After the development of power electronics converters, the number of transformers subjected to non-sinusoidal stresses (including DC) has increased in applications such as HVDC links and traction (electric train power cars). The effects of non-sinusoidal voltages on transformer insulation have been investigated by many researchers, but still now, there are some issues that must be understood. Some of those issues are tackled in this Thesis, studying PD phenomena behavior in Kraft paper, pressboard and mineral oil at different voltage conditions like AC, DC, AC+DC, notched AC and square waveforms. From the point of view of converter transformers, it was found that the combined effect of AC and DC voltages produces higher stresses in the pressboard that those that are present under pure DC voltages. The electrical conductivity of the dielectric systems in DC and AC+DC conditions has demonstrated to be a critical parameter, so, its measurement and analysis was also taken into account during all the experiments. Regarding notched voltages, the RMS reduction caused by notches (depending on firing and overlap angles) seems to increase the PDIV. However, the experimental results show that once PD activity has incepted, the notches increase PD repetition rate and magnitude, producing a higher degradation rate of paper. On the other hand, the reduction of mineral oil stocks, their relatively low flash point as well as environmental issues, are factors that are pushing towards the use of esters as transformer insulating fluids. This PhD Thesis also covers the study of two different esters with the scope to validate their use in traction transformers. Mineral oil was used as benchmark. The complete set of dielectric tests performed in the three fluids, show that esters behave better than mineral oil in practically all the investigated conditions, so, their application in traction transformers is possible and encouraged.
Resumo:
This thesis presents a possible method to calculate sea level variation using geodetic-quality Global Navigate Satellite System (GNSS) receivers. Three antennas are used: two small antennas and a choke ring one, analyzing only Global Positioning System signals. The main goal of the thesis is to test a modified configuration for antenna set up. In particular, measurements obtained tilting one antenna to face the horizon are compared to measurements obtained from antennas looking upward. The location of the experiment is a coastal environment nearby the Onsala Space Observatory in Sweden. Sea level variations are obtained using periodogram analysis of the SNR signal and compared to synthetic gauge generated from two independent tide gauges. The choke ring antenna provides poor result, with an RMS around 6 cm and a correlation coefficients of 0.89. The smaller antennas provide correlation coefficients around 0.93. The antenna pointing upward present an RMS of 4.3 cm and the one pointing the horizon an RMS of 6.7 cm. Notable variation in the statistical parameters is found when modifying the length of the interval analyzed. In particular, doubts are risen on the reliability of certain scattered data. No relation is found between the accuracy of the method and weather conditions. Possible methods to enhance the available data are investigated, and correlation coefficient above 0.97 can be obtained with small antennas when sacrificing data points. Hence, the results provide evidence of the suitability of SNR signal analysis for sea level variation in coastal environment even in the case of adverse weather conditions. In particular, tilted configurations provides comparable result with upward looking geodetic antennas. A SNR signal simulator is also tested to investigate its performance and usability. Various configuration are analyzed in combination with the periodogram procedure used to calculate the height of reflectors. Consistency between the data calculated and those received is found, and the overall accuracy of the height calculation program is found to be around 5 mm for input height below 5 m. The procedure is thus found to be suitable to analyze the data provided by the GNSS antennas at Onsala.
Resumo:
Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.