916 resultados para peripheral venous catheters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Implanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques. METHODS AND MATERIALS: Through a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new "mechanical adhesiolysis" maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication. RESULTS: Eighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted. CONCLUSION: These IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to assess experimentally the usefulness of some procedures employed in man to prevent venous thrombosis following phlebography, thrombosis was induced in rats using sodium diatrizoate in a temporarily isolated segment of a jugular vein. The prevention of thrombosis was attempted by washing out the vein with physiologic saline or saline plus heparin or by injecting saline plus heparin in the opposite jugular vein. Thrombosis occurred in all animals in the control group and in the group treated with saline alone. Both treatment schemes with heparin significantly reduced the incidence of thrombosis, the wash out with heparin being more effective than systemic heparin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective - To investigate the effects of inhalation and total IV anesthesia on pituitary-adrenal activity in ponies. Animals - 9 healthy ponies: 5 geldings and 4 mares. Procedure - Catheters were placed in the cavernous sinus below the pituitary gland and in the subarachnoid space via the lumbosacral space. After 72 hours, administration of acepromazine was followed by induction of anesthesia with thiopentone and maintenance with halothane (halothane protocol), or for the IV protocol, anesthesia induction with detomidine and ketamine was followed by maintenance with IV infusion of a detomidine-ketamine-guaifenesin combination. Arterial blood pressure and gas tensions were measured throughout anesthesia. Peptide and catecholamine concentrations were measured in pituitary effluent, peripheral plasma, and CSF. Peripheral plasma cortisol, glucose, and lactate concentrations also were measured. Results - Intravenous anesthesia caused less cardiorespiratory depression than did halothane. ACTH, metenkephalin, arginine vasopressin, and norepinephrine pituitary effluent and peripheral plasma concentrations were higher during halothane anesthesia, with little change during intravenous anesthesia. Pituitary effluent plasma β-endorphin and peripheral plasma cortisol concentrations increased during halothane anesthesia only. Dynorphin concentrations did not change in either group. Hyperglycemia developed during intravenous anesthesia only Minimal changes occurred in CSF hormonal concentrations during anesthesia. Conclusion - The pituitary gland has a major role in maintaining circulating peptides during anesthesia. Compared with halothane, IV anesthesia appeared to suppress pituitary secretion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The risk for venous thromboembolism (VTE) in medical patients is high, but risk assessment is rarely performed because there is not yet a good method to identify candidates for prophylaxis. Purpose: To perform a systematic review about VTE risk factors (RFs) in hospitalized medical patients and generate recommendations (RECs) for prophylaxis that can be implemented into practice. Data sources: A multidisciplinary group of experts from 12 Brazilian Medical Societies searched MEDLINE, Cochrane, and LILACS. Study selection: Two experts independently classified the evidence for each RF by its scientific quality in a standardized manner. A risk-assessment algorithm was created based on the results of the review. Data synthesis: Several VTE RFs have enough evidence to support RECs for prophylaxis in hospitalized medical patients (eg, increasing age, heart failure, and stroke). Other factors are considered adjuncts of risk (eg, varices, obesity, and infections). According to the algorithm, hospitalized medical patients ≥40 years-old with decreased mobility, and ≥1 RFs should receive chemoprophylaxis with heparin, provided they don't have contraindications. High prophylactic doses of unfractionated heparin or low-molecular-weight-heparin must be administered and maintained for 6-14 days. Conclusions: A multidisciplinary group generated evidence-based RECs and an easy-to-use algorithm to facilitate VTE prophylaxis in medical patients. © 2007 Rocha et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Semiquantitative (Maki) and quantitative (Brun- Buisson) culture techniques were employed in the diagnosis of catheter-related bloodstream infections (CRBSI) in patients who have a short-term central venous catheter (inserted for 30 days). The diagnosis of CRBSI was based on the results of semiquantitative and quantitative culture of material from the removed catheters. Catheter tips (118) from 100 patients were evaluated by both methods. Semiquantitative analysis revealed 34 catheters (28.8%) colonized by ≥15 colonyforming units (cfu), while quantitative cultures (34 catheters, 28.8%) showed the growth of ≥103 cfu/mL. Bacteremia was confirmed in four patients by isolating microorganisms of identical species from both catheters and blood samples. Using the semiquantitative culture technique on short-term central venous catheter tips, we have shown that with a cut-off level of ≥15 cfu, the technique had 100.0% sensitivity, specificity of 68.4%, 25.0% positive predictive value (PPV) and 100.0% negative predictive value (NPV), efficiency of 71.4% and a prevalence of 9.5%. The quantitative method, with a cut-off limit of ≥103 cfu/mL, gave identical values: the sensitivity was 100.0%, specificity 68.4%, positive predictive value (PPV) 25.0%, negative predictive value (NPV) 100.0%, efficiency 71.4% and prevalence 9.5%. We concluded that the semiquantitative and quantitative culture methods, evaluated in parallel, for the first time in Brazil, have similar sensitivity and specificity. Keywords: central venous catheter; semi-quantitative culture; quantitative culture; catheter-related bacteremia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We described recently that systemic hypoxia provokes vasoconstriction in heart failure (HF) patients. We hypothesized that either the exaggerated muscle sympathetic nerve activity and/or endothelial dysfunction mediate the blunted vasodilatation during hypoxia in HF patients. Twenty-seven HF patients and 23 age-matched controls were studied. Muscle sympathetic nerve activity was assessed by microneurography and forearm blood flow (FBF) by venous occlusion plethysmography. Peripheral chemoreflex control was evaluated through the inhaling of a hypoxic gas mixture (10% O-2 and 90% N-2). Basal muscle sympathetic nerve activity was greater and basal FBF was lower in HF patients versus controls. During hypoxia, muscle sympathetic nerve activity responses were greater in HF patients, and forearm vasodilatation in HF was blunted versus controls. Phentolamine increased FBF responses in both groups, but the increase was lower in HF patients. Phentolamine and N-G-monomethyl-L-arginine infusion did not change FBF responses in HF but markedly blunted the vasodilatation in controls. FBF responses to hypoxia in the presence of vitamin C were unchanged and remained lower in HF patients versus controls. In conclusion, muscle vasoconstriction in response to hypoxia in HF patients is attributed to exaggerated reflex sympathetic nerve activation and blunted endothelial function (NO activity). We were unable to identify a role for oxidative stress in these studies. (Hypertension. 2012; 60: 669-676.) . Online Data Supplement

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Walking with high-heeled shoes is a common cause of venous complaints such as pain, fatigue, and heavy-feeling legs. The aim of the study was to clarify the influence of high-heeled shoes on the venous return and test the hypothesis that women wearing different styles of high-heeled shoes present an impaired venous return when compared with their values when they are barefoot. Methods: Thirty asymptomatic women (mean age, 26.4 years) wearing appropriately sized shoes were evaluated by air plethysmography (APG), a test that measures changes in air volume on a cuff placed on the calf, while they performed orthostatic flexion and extension foot movements and altered standing up and lying down. The test was repeated in four situations: barefoot (0 cm), medium heels (3.5 cm), stiletto high heels (7 cm), and platform high heels (7 cm). The APG values of venous filling index (VFI), ejection fraction (EF), and residual volume fraction (RVF) were divided into four groups according to heel height and compared by repeated-measures analysis of variance. Results: RVF was increased in the groups wearing high heels (stiletto and platform) compared with the barefoot group (P < .05). RVF was increased in the medium-heel group (3.5 cm) compared with the barefoot group (P < .05), and despite the lack of statistical significance, the medium-heel group showed lower values of RVF compared with the two high-heel groups. The EF parameter followed the opposite tendency, showing higher values for the barefoot group compared with the other three groups (P < .05). Values for VFI were similar in the three situations evaluated. Conclusions: High heels reduce muscle pump function, as demonstrated by reduced EF and increased RVF values. The continuous use of high heels tends to provoke venous hypertension in the lower limbs and may represent a causal factor of venous disease symptoms. (J Vasc Surg 2012;56:1039-44.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Dual antiplatelet therapy with clopidogrel plus acetylsalicylic acid (ASA) is superior to ASA alone in patients with acute coronary syndromes and in those undergoing percutaneous coronary intervention. We sought to determine whether clopidogrel plus ASA conferred benefit on limb outcomes over ASA alone in patients undergoing below-knee bypass grafting. METHODS: Patients undergoing unilateral, below-knee bypass graft for atherosclerotic peripheral arterial disease (PAD) were enrolled 2 to 4 days after surgery and were randomly assigned to clopidogrel 75 mg/day plus ASA 75 to 100 mg/day or placebo plus ASA 75 to 100 mg/day for 6 to 24 months. The primary efficacy endpoint was a composite of index-graft occlusion or revascularization, above-ankle amputation of the affected limb, or death. The primary safety endpoint was severe bleeding (Global Utilization of Streptokinase and Tissue plasminogen activator for Occluded coronary arteries [GUSTO] classification). RESULTS: In the overall population, the primary endpoint occurred in 149 of 425 patients in the clopidogrel group vs 151 of 426 patients in the placebo (plus ASA) group (hazard ratio [HR], 0.98; 95% confidence interval [CI], 0.78-1.23). In a prespecified subgroup analysis, the primary endpoint was significantly reduced by clopidogrel in prosthetic graft patients (HR, 0.65; 95% CI, 0.45-0.95; P = .025) but not in venous graft patients (HR, 1.25; 95% CI, 0.94-1.67, not significant [NS]). A significant statistical interaction between treatment effect and graft type was observed (P(interaction) = .008). Although total bleeds were more frequent with clopidogrel, there was no significant difference between the rates of severe bleeding in the clopidogrel and placebo (plus ASA) groups (2.1% vs 1.2%). CONCLUSION: The combination of clopidogrel plus ASA did not improve limb or systemic outcomes in the overall population of PAD patients requiring below-knee bypass grafting. Subgroup analysis suggests that clopidogrel plus ASA confers benefit in patients receiving prosthetic grafts without significantly increasing major bleeding risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major concern with the use of continuous peripheral nerve block is the difficulty encountered in placing the catheters close enough to the nerves to accomplish effective analgesia. The aim of this study was to investigate if a self-coiling catheter would remain close to the sciatic nerve once introduced through needles placed under ultrasound guidance and if contrast dye injected through the pigtail catheter made direct contact to the nerves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fibroblast-like cells isolated from peripheral blood of human, canine, guinea pig, and rat have been demonstrated to possess the capacity to differentiate into several mesenchymal lineages. The aim of this work was to investigate the possibility of isolating pluripotent precursor cells from equine peripheral blood and compare them with equine bone marrow-derived mesenchymal stem cells. Human mesenchymal stem cells (MSCs) were used as a control for cell multipotency assessment. Venous blood (n = 33) and bone marrow (n = 5) were obtained from adult horses. Mononuclear cells were obtained by Ficoll gradient centrifugation and cultured in monolayer, and adherent fibroblast-like cells were tested for their differentiation potential. Chondrogenic differentiation was performed in serum-free medium in pellet cultures as a three-dimensional model, whereas osteogenic and adipogenic differentiation were induced in monolayer culture. Evidence for differentiation was made via biochemical, histological, and reverse transcription-polymerase chain reaction evaluations. Fibroblast-like cells were observed on day 10 in 12 out of 33 samples and were allowed to proliferate until confluence. Equine peripheral blood-derived cells had osteogenic and adipogenic differentiation capacities comparable to cells derived from bone marrow. Both cell types showed a limited capacity to produce lipid droplets compared to human MSCs. This result may be due to the assay conditions, which are established for human MSCs from bone marrow and may not be optimal for equine progenitor cells. Bone marrow-derived equine and human MSCs could be induced to develop cartilage, whereas equine peripheral blood progenitors did not show any capacity to produce cartilage at the histological level. In conclusion, equine peripheral blood-derived fibroblast-like cells can differentiate into distinct mesenchymal lineages but have less multipotency than bone marrow-derived MSCs under the conditions used in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessment of regional blood flow changes is difficult in the clinical setting. We tested whether conventional pulmonary artery catheters (PACs) can be used to measure regional venous blood flows by inverse thermodilution (ITD). Inverse thermodilution was tested in vitro and in vivo using perivascular ultrasound Doppler (USD) flow probes as a reference. In anesthetized pigs, PACs were inserted in jugular, hepatic, renal, and femoral veins, and their measurements were compared with simultaneous USD flow measurements from carotid, hepatic, renal, and femoral arteries and from portal vein. Fluid boluses were injected through the PAC's distal port, and temperature changes were recorded from the proximally located thermistor. Injectates of 2 and 5 mL at 22 degrees C and 4 degrees C were used. Flows were altered by using a roller pump (in vitro), and infusion of dobutamine and induction of cardiac tamponade, respectively. In vitro: At blood flows between 400 mL . min-1 and 700 mL . min-1 (n = 50), ITD and USD correlated well (r = 0.86, P < 0.0001), with bias and limits of agreement of 3 +/- 101 mL . min-1. In vivo: 514 pairs of measurements had to be excluded from analysis for technical reasons, and 976 were analyzed. Best correlations were r = 0.87 (P < 0.0001) for renal flow and r = 0.46 (P < 0.0001) for hepatic flow. No significant correlation was found for cerebral and femoral flows. Inverse thermodilution using conventional PAC compared moderately well with USD for renal but not for other flows despite good in vitro correlation in various conditions. In addition, this method has significant technical limitations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Endothelial progenitor cells (EPC) are involved in many healing processes in cardiovascular diseases and can be found in spontaneously resolving venous thrombi. The purpose of the present study was to investigate whether the therapeutic administration of EPC might enhance the resolution of venous thrombi. For this purpose, venous thrombosis was induced in the infrarenal inferior vena cava (IVC) in 28 athymic nude rats. Culture expanded EPC derived from human peripheral blood mononuclear cells were injected intravenously two and four days after thrombus induction. Recanalisation of the IVC and thrombus organisation were assessed by laser Doppler measurements of the blood flow and immunohistochemical detection of endothelialised luminal structures in the thrombus. EPC transplantation resulted in significantly enhanced thrombus neovascularisation (capillary density: 186.6 +/- 26.7/HPF vs. 78 +/- 12.3/HPF, p<0.01; area covered by capillaries: 8.9 +/- 1.7 microm(2) vs. 2.5 +/- 1.3 microm(2), p<0.01) and was accompanied by a substantial increase in intra-thrombus blood flow (perfusion ratio: 0.7 +/- 0.07 vs. 0.3 +/- 0.08, p<0.02). These results were paralleled by augmented macrophage recruitment into resolving thrombi in the animals treated with EPC (39.4 +/- 4.7/HPF vs. 11.6 +/- 1.9/HPF, p<0.01). Our data suggest that EPC transplantation might be of clinical value to facilitate venous thrombus resolution in cases where current therapeutic options have limited success.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.